Choosing an Oscilloscope with the Right Bandwidth for your Application

Similar documents
Evaluating Oscilloscope Bandwidths for your Application

When is it Time to Transition to a Higher Bandwidth Oscilloscope?

Characterizing High-Speed Oscilloscope Distortion A comparison of Agilent and Tektronix high-speed, real-time oscilloscopes

A Time-Saving Method for Analyzing Signal Integrity in DDR Memory Buses

Using an MSO to Debug a PIC18-Based Mixed-Signal Design

Flexible Signal Conditioning with the Help of the Agilent 81134A Pulse Pattern Generator

Picking the Optimal Oscilloscope for Serial Data Signal Integrity Validation and Debug

Waveform Ghost Busters Capturing and Analyzing Random and Infrequent Signal Anomalies

Evaluating Oscilloscope Sample Rates vs. Sampling Fidelity

Agilent N8480 Series Thermocouple Power Sensors. Technical Overview

Agilent U2000 Series USB Power Sensors. Data Sheet

N2790A 100 MHz, N2791A 25 MHz and N2891A 70 MHz High-voltage Differential Probes

Agilent U1881A and U1882A Power Measurement Application for Agilent InfiniiVision and Infiniium Oscilloscopes

Keysight Technologies Minimum Required Sample Rate for a 1-GHz Bandwidth Oscilloscope

6 Tips for Successful Logic Analyzer Probing

Educator s Oscilloscope Training Kit for the InfiniiVision 2000 & 3000 X-Series

Multipurpose Lab Station by Agilent Technologies

AC : EVALUATING OSCILLOSCOPE SAMPLE RATES VS. SAM- PLING FIDELITY

UWB Antenna Measurements with the 20 GHz E5071C ENA Network Analyzer

Agilent 81150A Pulse Function Arbitrary Noise Generator Applications

Agilent Highly Accurate Amplifier ACLR and ACPR Testing with the Agilent N5182A MXG Vector Signal Generator. Application Note

Jitter Analysis Techniques Using an Agilent Infiniium Oscilloscope

Agilent E8267C PSG Vector Signal Generator

MEMS On-wafer Evaluation in Mass Production Testing At the Earliest Stage is the Key to Lowering Costs

MIL-STD 1553 Triggering and Hardwarebased Decode (Option 553) for Agilent s InfiniiVision Series Oscilloscopes

Agilent AN Balanced Circuit Measurement with an Impedance Analyzer/LCR Meter/Network Analyzer Application Note

Agilent Spectrum Visualizer (ASV) Software. Data Sheet

Agilent AN Balanced Circuit Measurement with an Impedance Analyzer/LCR Meter/Network Analyzer Application Note

Educator s Oscilloscope Training Kit for Agilent InfiniiVision X-Series Oscilloscopes

Agilent NFA Noise Figure Analyzer

Two-Way Radio Testing with Agilent U8903A Audio Analyzer

Advanced Test Equipment Rentals ATEC (2832)

Keysight Technologies Evaluating Oscilloscope Sample Rates vs. Sampling Fidelity. Application Note

Agilent E8247/E8257C PSG CW and Analog Signal Generators

Process Control Calibration Made Easy with Agilent U1401A

VSA80000A Ultra-Wideband Vector Signal Analyzer

Agilent Technologies 3000 Series Oscilloscopes

Agilent 83440B/C/D High-Speed Lightwave Converters

Agilent E9300 Power Sensors E-Series Technical Overview

Agilent Maximizing Measurement Speed Using P-Series Power Meters

Agilent N8973A, N8974A, N8975A NFA Series Noise Figure Analyzers. Data Sheet

Agilent E6651A Mobile WiMAX Test Set

Agilent Correlation between TDR oscilloscope and VNA generated time domain waveform

Techniques to Achieve Oscilloscope Bandwidths of Greater Than 16 GHz

Agilent MXG Signal Generators

Discovering New Techniques of Creating, Editing, and Transferring Arbitrary Waveforms

Time-Domain Response of Agilent InfiniiMax Probes and Series Infiniium Oscilloscopes

7 Hints That Every Engineer Should Know When Making Power Measurements with Oscilloscopes.

Product Note E5100A-2

PCI Express Receiver Design Validation Test with the Agilent 81134A Pulse Pattern Generator/ 81250A ParBERT. Product Note

8 Hints for Better Spectrum Analysis. Application Note

How to capture, save, and reproduce arbitrary load current waveforms

Agilent Introduction to the Fixture Simulator Function of the ENA Series RF Network Analyzers: Network De-embedding/Embedding and Balanced Measurement

Creating Arbitrary Waveforms in the U2300A Series and U2500A Series Data Acquisition Devices

Agilent InfiniiMax III probing system


5 Common Mistakes to Avoid When Buying a Low-cost Oscilloscope

Solutions for Solar Cell and Module Testing

Agilent N4000A, N4001A, N4002A SNS Series Noise Sources 10 MHz to 26.5 GHz

Agilent Digital Modulation Lab Station

Agilent N9310A RF Signal Generator

Agilent U9397A/C FET Solid State Switches (SPDT)

Make Better RMS Measurements with Your DMM. Application Note 1392

Agilent 8648A/B/C/D Signal Generators

Agilent Technologies 3000 Series Oscilloscopes

Agilent CSA Spectrum Analyzer

Agilent MXG Signal Generators

Agilent N1911A/N1912A P-Series Power Meters and N1921A/N1922A Wideband Power Sensors. Data sheet

Agilent 34405A Multimeter 5.5 Digit Dual Display, Benchtop DMM More Capabilities at a Value Price

Agilent E4438C ESG Vector Signal Generator Differential I/Q outputs. Product Note

Evaluating Oscilloscopes for Low-Power Measurements

Agilent 86030A 50 GHz Lightwave Component Analyzer Product Overview

Oscilloscope Fundamentals. For Electrical Engineering and Physics Undergraduate Students

Agilent 4294A Precision Impedance Analyzer, 40 Hz to 110 MHz. Configuration Guide

1How much bandwidth do you need?

Educator s Oscilloscope Training Kit for the InfiniiVision 2000 & 3000 X-Series

Agilent 87222C/D/E Coaxial Transfer Switches dc to 26.5, 40, 50 GHz

Agilent 83711B and 83712B Synthesized CW Generators

Agilent 87405B. Preamplifier 10 MHz to 4 GHz. Technical Overview. Features. Benchtop/General Purpose Use

Agilent PSA Series Spectrum Analyzers Self-Guided Demonstration for Phase Noise Measurements

How to Select Your Next Oscilloscope: 12 Tips on What to Consider Before you Buy

U1881A and U1882A Power Measurement Application for InfiniiVision and Infiniium Oscilloscopes

Agilent 87075C Multiport Test Set

Agilent PSA Series Spectrum Analyzers Noise Figure Measurements Personality

Phase Noise Measurement Personality for the Agilent ESA-E Series Spectrum Analyzers

Bandwidth Alone Measurement Accuracy

Meet the new E4438C ESG vector signal generator...

Agilent 71400C Lightwave Signal Analyzer Product Overview. Calibrated measurements of high-speed modulation, RIN, and laser linewidth

Keysight Technologies Oscilloscope Probe Loading Experiment

If I Could... Imagine Perfect Vision

Agilent 8360B Series Synthesized Swept Signal Generators 8360L Series Synthesized Swept CW Generators

Educator s Oscilloscope Training Kit for Agilent InfiniiVision X-Series Oscilloscopes

Agilent Combining Network and Spectrum Analysis and IBASIC to Improve Device Characterization and Test Time

Agilent E4438C/E8267D Option 422 Scenario Generator for GPS

Agilent E7400A Series EMC Analyzers

InfiniiMax III probing system

Agilent dc Electronic Loads Models N3300A-N3307A

Advanced Measurement Techniques for RF Amplifiers Using Unique Functions of the Agilent E5071C ENA. Application Note

Agilent 8703B Lightwave Component Analyzer Technical Specifications. 50 MHz to GHz modulation bandwidth

Agilent Technologies 3000 Series Oscilloscopes

Transcription:

Choosing an Oscilloscope with the Right Bandwidth for your Application Application Note 1588 Table of Contents Introduction.......................1 Defining Oscilloscope Bandwidth.....2 Required Bandwidth for Digital Applications......................4 Digital Clock Measurement Comparisons......................6 Required Bandwidth for Analog Applications......................8 Summary.........................9 Related Agilent Literature.......... 10 Glossary......................... 11 Introduction Bandwidth is the specification that most engineers consider first when they select an oscilloscope. In this application note we will provide you some helpful hints on how to select an oscilloscope with the appropriate bandwidth for both your digital and analog applications. But first, let s define oscilloscope bandwidth.

Defining Oscilloscope Bandwidth All oscilloscopes exhibit a low-pass frequency response that rolls-off at higher frequencies, as shown in Figure 1. Most scopes with bandwidth specifications of 1 GHz and below typically have what is called a Gaussian response, which exhibits a slow roll-off characteristic beginning at approximately one-third the -3dB frequency. Oscilloscopes with bandwidth specifications greater than 1 GHz typically have a maximally flat frequency response, as shown in Figure 2. This type of response usually exhibits a flatter in-band response with a sharper roll-off characteristic near the -3 db frequency. There are advantages and disadvantages to each of these types of oscilloscope frequency responses. Oscilloscopes with a maximally-flat response attenuate in-band signals less than scopes with Gaussian response, meaning that scopes with maximally-flat responses are able to make more accurate measurements on in-band signals. But a scope with Gaussian response attenuates out-ofband signals less than a scope with maximally-flat response, meaning that scopes with Gaussian responses typically have a faster rise time than scopes with a maximally-flat response, given the same bandwidth specification. But sometimes it is advantageous to attenuate out-of-band signals to a higher degree in order to help eliminate higher-frequency components that can contribute to aliasing in order to satisfy Nyquist criteria (f MAX < f S ). For a deeper understanding of Nyquist s sampling theory, refer to Agilent Application Note 1587, Evaluating Oscilloscope Sample Rates vs. Sampling Fidelity. Figure 1: Oscilloscope Gaussian frequency response Figure 2: Oscilloscope maximally-flat frequency response 2

Defining Oscilloscope Bandwidth (continue) Whether your scope has a Gaussian response, maximally-flat response, or somewhere in between, the lowest frequency at which the input signal is attenuated by 3 db is considered the scope s bandwidth. Oscilloscope bandwidth and frequency response can be tested with a swept frequency using a sine wave signal generator. Signal attenuation at the -3 db frequency translates into approximately -30% amplitude error. So you can t expect to make accurate measurements on signals that have significant frequencies near your scope s bandwidth. Closely related to an oscilloscope s bandwidth specification is its rise time specification. Scopes with a Gaussian-type response will have an approximate rise time of 0.35/f BW based on a 10% to 90% criterion. Scopes with maximally-flat response typically have rise time specifications in the range of 0.4/f BW, depending on the sharpness of the frequency roll-off characteristic. But you need to remember that a scope s rise time is not the fastest edge speed that the oscilloscope can accurately measure. It is the fastest edge speed the scope can possibly produce if the input signal has a theoretical infinitely fast rise time (0 ps). Although this theoretical specification is impossible to test since pulse generators don t have infinitely fast edges from a practical perspective, you can test your oscilloscope s rise time by inputting a pulse that has edge speeds that are 3 to 5 times faster than the scope s rise time specification. 3

Required Bandwidth for Digital Applications As a rule of thumb, your scope s bandwidth should be at least five times higher than the fastest digital clock rate in your system under test. If your scope meets this criterion, it will capture up to the fifth harmonic with minimum signal attenuation. This component of the signal is very important in determining the overall shape of your digital signals. But if you need to make accurate measurements on highspeed edges, this simple formula does not take into account the actual highest-frequency components embedded in fast rising and falling edges. Rule of thumb f BW 5 x f clk A more accurate method to determine required oscilloscope bandwidth is to ascertain the maximum frequency present in your digital signals, which is not the maximum clock rate. The maximum frequency will be based on the fastest edge speeds in your designs. So the first thing you need to do is determine the rise and fall times of your fastest signals. You can usually obtain this information from published specifications for devices used in your designs. Step 1: Determine fastest edge speeds You can then use a simple formula to compute the maximum practical frequency component. Dr. Howard W. Johnson has written a book on this topic, High-speed Digital Design A Handbook of Black Magic. 1 He refers to this frequency component as the knee frequency (f knee ). All fast edges have an infinite spectrum of frequency components. However, there is an inflection (or knee ) in the frequency spectrum of fast edges where frequency components higher than f knee are insignificant in determining the shape of the signal. Step 2: Calculate f knee f knee = 0.5 / RT (10% - 90%) f knee = 0.4 / RT (20% - 80%) For signals with rise time characteristics based on 10% to 90% thresholds, f knee is equal to 0.5 divided by the rise time of the signal. For signals with rise time characteristics based on 20% to 80% thresholds, which is very common in many of today s device specifications, f knee is equal to 0.4 divided by the rise time of the signal. Now don t confuse these rise times with a scope s specified rise time. We are talking about actual signal edge speeds. The third step is to determine the oscilloscope bandwidth required to measure this signal, based on your desired degree of accuracy when measuring rise times and fall times. Table 1 shows multiplying factors for various degrees of accuracy for scopes with a Gaussian or a maximally-flat frequency response. Remember, most scopes with bandwidth specifications of 1 GHz and below typically have a Gaussiantype response, and most scopes with bandwidths greater than 1 GHz typically have a maximally-flat type response. Step 3: Calculate scope bandwidth Required Gaussian Maximally-flat accuracy response response 20% f BW = 1.0 x f knee f BW = 1.0 x f knee 10% f BW = 1.3 x f knee f BW = 1.2 x f knee 3% f BW = 1.9 x f knee f BW = 1.4 x f knee Table 1: Multiplying factors to calculate required scope bandwidth based on desired accuracy and type of scope frequency response 4

Required Bandwidth for Digital Applications (continued) Let s now walk through this simple example: Determine the minimum required bandwidth of an oscilloscope with an approximate Gaussian frequency response to measure a 500-ps rise time (10-90%) If the signal has an approximate rise/ fall time of 500 ps (based on a 10% to 90% criteria), then the maximum practical frequency component (f knee ) in the signal would be approximately 1 GHz. f knee = (0.5/500ps) = 1 GHz If you are able tolerate up to 20% timing errors when making parametric rise time and fall time measurements on your signals, then you could use a 1 GHz bandwidth oscilloscope for your digital measurement applications. But if you need timing accuracy in the range of 3%, then a scope with 2-GHz bandwidth would be the better choice. 20% timing accuracy: Scope BW = 1.0 x 1 GHz = 1.0 GHz 3% timing accuracy: Scope BW = 1.9 x 1 GHz =1.9 Let s now make some measurements on a digital clock signal with characteristics similar to this example, using various bandwidth scopes... 5

Digital Clock Measurement Comparisons Figure 3 shows the waveform results when measuring a 100-MHz digital clock signal with 500 ps edge speeds (10% to 90%) using an Agilent MSO6014A 100-MHz bandwidth oscilloscope. As you can see, this scope primarily just passes through the 100-MHz fundamental of this clock signal, thus representing our clock signal as an approximate sine wave. A 100-MHz scope may be a good solution for many 8-bit, MCU-based designs with clock rates in the 10-MHz to 20- MHz range, but 100-MHz bandwidth is clearly insufficient for this 100-MHz clock signal. Using an Agilent MSO7054A 500-MHz bandwidth oscilloscope, Figure 4 shows that this scope is able to capture up to the fifth harmonic, which was our first rule of thumb recommendation. But when we measure the rise time, we see that the scope measures approximately 750 ps. In this case, the scope is not making a very accurate measurement on the rise time of this signal. The scope is actually measuring something closer to its own rise time (700 ps), not the input signal s rise time, which is closer to 500 ps. We need a higher-bandwidth scope for this digital measurement application if timing measurements are important. Figure 3: 100-MHz clock captured on the Agilent MSO6014A 100-MHz bandwidth scope Figure 4: 100-MHz clock captured on the Agilent MSO7054A 500-MHz bandwidth scope 6

Digital Clock Measurement Comparisons (continued) With an Agilent 1-GHz MSO7104A bandwidth scope, we have a much more accurate picture of this signal, as shown in Figure 5. When we select a rise time measurement on this scope, we measure approximately 550 ps. This measurement is providing us with approximately 10% measurement accuracy and may be a very acceptable measurement solution especially if capital funding is an issue. However, even this measurement using a 1-GHz bandwidth scope might be considered borderline. If we want to make edgespeed measurements with greater than 3% accuracy on this signal with 500ps edge speeds, we really need to use a scope with 2 GHz bandwidth or higher, as we determined in the walk-through example earlier. With a 2 GHz bandwidth scope, now we are seeing an accurate representation of this clock signal along with a very accurate rise time measurement of approximately 495 ps, as shown in Figure 6. Figure 5: 100-MHz clock captured on the Agilent MSO7104A 1-GHz bandwidth scope One thing nice about the Infiniium Series high-bandwidth oscilloscopes is that their bandwidth is upgradeable. So if 2 GHz bandwidth is sufficient for today, you can initially purchase the entry level 2 GHz scope and then upgrade all the way up to 13 GHz in the future, if you need additional bandwidth. Figure 6: 100-MHz clock captured on the Agilent DSO80204B 2-GHz bandwidth scope 7

Required Bandwidth for Analog Applications Years ago, most oscilloscope vendors recommended that your scope s bandwidth should be at least three times higher than the maximum signal frequency. Although this 3X multiplying factor would not apply to digital applications, it still applies to analog applications, such as modulated RF. To understand where this 3-to-1 multiplying factor comes from, let s look at an actual frequency response of a 1-GHz bandwidth scope. -1.7 db @ 1 GHz Figure 7 shows a swept response test (20 MHz to 2 GHz) on the Agilent MSO7104A 1-GHz bandwidth oscilloscope. As you can see, at exactly 1 GHz the input is attenuated by about 1.7 db, which is well within the -3 db limitation that defines this scope s bandwidth. However, to make accurate measurements on analog signals, you need to use the scope in the portion of the frequency band where it is still relatively flat with minimal attenuation. At approximately one-third the scope s 1 GHz bandwidth, this scope exhibits virtually no attenuation (0 db). However, not all scopes exhibit this type of response. The swept frequency response test shown in Figure 8 was performed on a 1.5-GHz bandwidth scope from another scope vendor. This is an example of a very non-flat frequency response. The characteristics of this response are neither Gaussian nor maximally-flat. It appears to be maximally bumpy and very peaked, which can result in severe waveform distortion on both analog and digital signals. Unfortunately, a scope s bandwidth specification, which is the 3 db attenuation frequency, says nothing about the attenuation or amplification at other frequencies. Even at Figure 7: Swept frequency response test on Agilent s MSO7104A 1-GHz bandwidth scope Figure 8: Swept frequency response test on a non-agilent 1.5-GHz bandwidth scope one-fifth this scope s bandwidth, signals are attenuated by approximately 1 db (10%) on this scope. -0 db @ 300 MHz -1.0 db @ 300 MHz -2.6 db @ 1 GHz So in this case, following the 3X rule of thumb would not be wise. When you are selecting a scope, it is a good idea to choose a reputable scope vendor and pay close attention to the relative flatness of the scope s frequency response. 8

Summary For digital applications, you should select a scope that has a bandwidth that is at least five times higher than the fastest clock rate in your design. But if you need to make accurate edge-speed measurements on your signals, you will need to determine the maximum practical frequency present in your signal. For analog applications, select a scope that has a bandwidth that is at least three times higher than the highest analog frequency of your designs. But this rule-of-thumb recommendation only applies to scopes that have a relatively flat response in their lower frequency band. This is something you won t need to worry about with Agilent oscilloscopes. And when you are considering a scope for today s applications, don t forget about tomorrow s applications. If your budget is flexible, buying a little extra margin today may save you money in the future. Agilent is the only scope vendor that offers bandwidth upgradeability in the Infiniium DSO90000A Series oscilloscopes, which comes in models that have bandwidths ranging from 2.5 GHz up to 13 GHz. 9

Related Agilent Literature Publication Description Agilent pub. number Agilent 7000 Series InfiniiVision Oscilloscopes Data sheet 5989-7736EN Agilent 8000 Series Infiniium Oscilloscopes Data sheet 5989-4271EN Agilent 90000 Series Infiniium Oscilloscopes Data sheet 5989-7919EN Agilent InfiniiVision Series Oscilloscope Probes and Accessories Data sheet 5989-8153EN Evaluating Oscilloscope Sample Rates vs. Sampling Fidelity Application note 5989-5732EN Advantages and Disadvantages of Using DSP Filtering on Application note 5989-1145EN Oscilloscope Waveforms Understanding Oscilloscope Frequency Response and Its Effect Application note 5988-8008EN on Rise-Time Accuracy Evaluating Oscilloscope Vertical Noise Characteristics Application note 5989-3020EN Evaluating Oscilloscopes for Best Signal Visibility Application note 5989-7885EN Debugging Embedded Mixed-Signal Designs Using Mixed Signal Oscilloscopes Application note 5989-3702EN Using an Agilent InfiniiVision Series MSO To Debug an Automotive CAN bus Application note 5989-5049EN To download these documents, insert the publication number in the URL: http://cp.literature.agilent.com/litweb/pdf/xxxx-xxxxen.pdf Product Web site For the most up-to-date and complete application and product information, please visit our product Web site at: www.agilent.com/find/scopes 10

Glossary a low-pass frequency response that has a slow roll-off characteristic that begins at approximately 1/3 the -3 db frequency (bandwidth). Oscilloscopes with band- Gaussian frequency response width In-band Knee frequency Maximally-flat response specifications of 1 GHz and below typically exhibit an approximate Gaussian response. frequency components below the -3 db (bandwidth) frequency the maximum practical frequency (f knee ) that determines the shape of a digital pulse, which can be computed if the approximate input signal s rise time is known (usually obtained for device specification data books) a low-pass frequency response that is relatively flat below the -3 db frequency and then rolls off sharply near the -3 db frequency (bandwidth). Oscilloscopes with bandwidth specifications greater than 1 GHz typically exhibit a maximally flat response. Nyquist sampling theorem states that for a limited bandwidth (band-limited) signal with maximum frequency f MAX, the equally spaced sampling frequency f S must be greater than twice the maximum frequency f MAX, in order to have the signal be uniquely reconstructed without aliasing Oscilloscope bandwidth Oscilloscope rise time Out-of-band Swept frequency response the lowest frequency at which input signal sine waves are attenuated by 3 db (-30% amplitude error) the fastest edge an oscilloscope can produce if the input signal has an infinitely fast edge speed. For scopes with an approximate Gaussian frequency response, the scope rise time can be computed as 0.35/f BW. Scopes with a maximally-flat frequency response typically have a rise time in the range of 0.4/f BW. frequency components above the -3 db frequency (bandwidth) a test using a signal generator where an output sine wave s frequency is repetitively swept from a user-defined lower frequency to a user-defined upper frequency to test the frequency response of an instrument or device 11

www.agilent.com/find/emailupdates Get the latest information on the products and applications you select. www.agilent.com/find/quick Quickly choose and use your test equipment solutions with confidence. www.agilent.com/find/open Agilent Open simplifies the process of connecting and programming test systems to help engineers design, validate and manufacture electronic products. Agilent offers open connectivity for a broad range of system-ready instruments, open industry software, PC-standard I/O and global support, which are combined to more easily integrate test system development. Microsoft and Windows are U.S. registered trademarks of Microsoft Corporation. Pentium is a U.S. registered trademark of Intel Corporation. Remove all doubt Our repair and calibration services will get your equipment back to you, performing like new, when promised. You will get full value out of your Agilent equipment throughout its lifetime. Your equipment will be serviced by Agilent-trained technicians using the latest factory calibration procedures, automated repair diagnostics and genuine parts. You will always have the utmost confidence in your measurements. Agilent offers a wide range of additional expert test and measurement services for your equipment, including initial start-up assistance onsite education and training, as well as design, system integration, and project management. For more information on repair and calibration services, go to www.agilent.com For more information on Agilent Technologies products, applications or services, please contact your local Agilent office. The complete list is available at: www.agilent.com/find/contactus Phone or Fax United States: (tel) 800 829 4444 (fax) 800 829 4433 Canada: (tel) 877 894 4414 (fax) 800 746 4866 China: (tel) 800 810 0189 (fax) 800 820 2816 Europe: (tel) 31 20 547 2111 Japan: (tel) (81) 426 56 7832 (fax) (81) 426 56 7840 Korea: (tel) (080) 769 0800 (fax) (080) 769 0900 Latin America: (tel) (305) 269 7500 Taiwan: (tel) 0800 047 866 (fax) 0800 286 331 Other Asia Pacific Countries: (tel) (65) 6375 8100 (fax) (65) 6755 0042 Email: tm_ap@agilent.com Revised: 09/14/06 Product specifications and descriptions in this document subject to change without notice. Agilent Technologies, Inc. 2008 Printed in USA, March 10, 2008 5989-5733EN