Control module CP-A CM

Similar documents
Control module CP-A CM

Three-phase monitoring relays

ABB NEW. Three-phase monitoring relays. CM-PVS.31 and CM-PVS.41 Data sheet. Features J. Approvals. Marks. Order data. Order data - Accessories

CM-MPS.11, CM-MPS-21, CM-MPS.31 and CM-MPS.41 Data sheet. UL 508, CAN/CSA C22.2 No.14 GL GOST CB scheme CCC

ABB NEW. Multifunctional three-phase monitoring relays. CM-MPS.23 and CM-MPS.43 Data sheet. Features J. Approvals. Marks.

Type CP-S, CP-C & CP-A Switch mode

Measuring and monitoring relays CM-SRS.1 Current monitoring relays, single-phase AC/DC

Electronic timer CT-SDS.22 Star-delta change-over with 2 n/o contacts Data sheet

ABB 1. Multifunctional three-phase monitoring relays. CM-MPS.11, CM-MPS-21, CM-MPS.31 and CM-MPS.41 Data sheet. Features. Approvals. Marks.

Pluggable interface relays CR-P Pcb relays

Electronic timer CT-SDD.22

Three-phase monitoring relay

Voltage monitoring relays CM-ESS.1 for single-phase AC/DC voltages

Electronic timer CT-TGD.22

ABB 1. Multifunctional three-phase monitoring relays. CM-MPN.52, CM-MPN.62 and CM-MPN.72 Data sheet. Features. Approvals. Marks.

Current monitoring relays CM-SRS.2 for single-phase AC/DC currents

Current monitoring relays CM-SRS.1 for single-phase AC/DC currents

Three-phase monitoring relay CM-PVE

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

Three-phase monitoring relays CM-PFE and CM-PFE.2

Voltage monitoring relay CM-EFS.2 For single-phase AC/DC voltages

Power supply CP-E 12/10.0 Primary switch mode power supply Data sheet

Current monitoring relays CM-SRS.1 For single-phase AC/DC currents

Electronic timer CT-ERS ON-delayed with 2 c/o contacts Data sheet

Electronic timer CT-AWS Impulse-OFF with 1 c/o contact Data sheet

Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection)

Current monitoring relays CM-SRS.2 For single-phase AC/DC currents

Power supply CP-E 24/0.75

Power supply CP-E 48/5.0 Primary switch mode power supply Data sheet

Power supply CP-E 24/20.0

Electronic timer CT-SDE Star-delta change-over with 1 n/c + 1 n/o contact

Electronic timer CT-TGD.12 Pulse generator with 1 c/o (SPDT) contact

Electronic timer CT-SDS.22

Electronic timer CT-SDE

Power supply CP-E 24/2.5

Three-phase monitoring relays CM-PVS CM-PVS.31, CM-PVS.41 and CM-PVS.81

Electronic timer CT-EBE Flasher starting with OFF, 1 c/o (SPDT) contact

Power supply CP-E 24/2.5

Three-phase monitoring relay CM-PFS

Three-phase monitoring relay CM-PBE

V2UM230V10 Art.Nr.: V2UM230V10P Art.Nr.: Control elements. Tripping delay. Function selector. Status indication 230 V AC/DC

Electronic timer CT-YDE Star-delta change-over with 1 c/o (SPDT) contact

Voltage monitoring relays CM-ESS.M For single-phase AC/DC voltages

Three-phase monitoring relays CM-PVS.81

Three-phase monitoring relays CM-PSS CM-PSS.31 and CM-PSS.41

VEO. V2PF480Y/277VS01 Art.Nr.: B TECHNICAL DATA

Three-phase monitoring relay

Power supply CP-T 24/20.0 Primary switch mode power supply

Power supply CP-T 24/10.0 Primary switch mode power supply

Power supply CP-D 24/1.3

Power supply CP-T 24/40.0 Primary switch mode power supply

Current monitoring relays CM-SRS.M1 For single-phase AC/DC currents

VEO. V2PF480Y/277VSY01 Art.Nr.: V2PF480Y/277VSY01P Art.Nr.: TECHNICAL DATA

Multifunctional three-phase monitoring relays CM-MPS CM-MPS.23 and CM-MPS.43

Electronic timer CT-AHS.22 OFF-delayed with 2 c/o (SPDT) contacts

Electronic timer CT-AHS.22 OFF-delayed with 2 c/o (SPDT) contacts

Multifunctional three-phase monitoring relays CM-MPS CM-MPS.23

Analog signal converters CC-E I/I

Multifunctional three-phase monitoring relays CM-MPN CM-MPN.52, CM-MPN.62 and CM-MPN.72

V2IM10AL10 Art.Nr.: V2IM10AL10P Art.Nr.: Control element. Tripping delay. Function selector. Status indication 24...

Electronic timer CT-AHE OFF-delayed with 1 c/o (SPDT) contact

Power supply CP-D 12/2.1

Power supply CP-T 48/20.0 Primary switch mode power supply

Power supply CP-T 48/5.0 Primary switch mode power supply

Electronic timer CT-AWE Impulse-OFF with auxiliary voltage, 1 c/o (SPDT) contact

Insulation monitoring relay CM-IWS.2 For unearthed AC systems up to U n = 400 V AC

Liquid level monitoring relay CM-ENS.2x

Electronic timer CT-WBS.22 Impulse generating and flashing with 2 c/o (SPDT) contacts

Coupling unit CM-IVN For expansion of the insulation monitoring relay CM-IWN.x measuring range up to U n = 690 V AC and 1000 V DC

Electronic timer CT-MFS.21

Electronic timer CT-MVS.12 Multifunctional with 1 c/o (SPDT) contact

Insulation monitoring relay CM-IWN.5 For unearthed AC, DC and mixed AC/DC systems up to U n = 400 V AC and 600 V DC

Thermistor motor protection relays

Insulation monitoring relay CM-IWS.1 For unearthed AC, DC and mixed AC/DC systems up to U n = 250 V AC and 300 V DC

Three-phase monitoring relays Product group picture

Electronic timer CT-MXS.22 Multifunctional with 2 c/o (SPDT) contacts

Moeller Electric Corporation

Electronic timer CT-MVS.23 Multifunctional with 2 c/o (SPDT) contacts

CP-T range Product group picture

Coupling unit CM-IVN For expansion of the insulation monitoring relay CM-IWN.x measuring range up to U n = 690 V AC and 1000 V DC

Power supply CP-D 24/4.2 Primary switch mode power supply

Electronic timer CT-MVS.23 Multifunctional with 2 c/o (SPDT) contacts

Three-phase monitoring relays Table of contents

Three-phase monitoring relays Product group picture

Insulation monitoring relays CM-IWN.4/5/6 For unearthed AC, DC and mixed AC/DC systems up to U n = 400 V AC and 600 V DC

Thermistor motor protection relays

Pluggable interface relays CR-U Universal relays

Electronic timer CT-MFS.21 Multifunctional with 2 c/o (SPDT) contacts

CP-T range Benefits and advantages

Insulation monitoring relay CM-IWN.1 For unearthed AC, DC and mixed AC/DC systems up to U n = 400 V AC and 600 V DC

Electronic timer CT-MFS.21 Multifunctional with 2 c/o (SPDT) contacts

CP-E range Benefits and advantages

EMD-FL-C-10. Current Monitoring Relay. Data Sheet. Functions. Structure 08/2004

Electronic timer CT-MBS.22 Multifunctional with 2 c/o (SPDT) contacts

Primary switch mode power supplies Product group picture

ABB ABB 59 2CDC110004C0205. Measuring and monitoring relays. CM and C5xx range. Content

Switching power supplies CP range, Linear power supplies CP-L range. Content

EN 50178, IEC

MINI-PS AC/24DC/1.3

Liquid level monitors and controls

Transcription:

Control module 2CDC 271 002 F0t05 Features Pluggable onto redundancy unit CP-A RU Adjustable threshold values (14-28 V) and relay outputs per input / channel Approvals Marks g 6 7 1 3 4 2 8 5 Order data Type Description Order code Output terminals Sense OUT : +, +, - Input terminals: channel 1: 12, 11, 14 channel 2: 22, 21, 24 Threshold value adjustment IN 1 <V for channel 1 Threshold value adjustment IN 2 <V for channel 2 OUT: green LED - output voltage > 3 V IN 1: green LED - threshold at channel 1 exceeded IN 2: green LED - threshold at channel 2 exceeded Schematic circuit diagram Control module 1SVR 427 075 R0000 Application The control module provides monitoring of the input signals of the redundancy unit CP-A RU. Operating mode The control module indicates the presence of both input voltages of the CP-A RU via LEDs and energized output relays. The threshold values for the output relays are adjustable separately per channel from 14 to 28 V. If, by a fault (e.g. failure of a power supply, blown fuse), the voltage in a channel drops below the adjusted threshold value, the corresponding output relay de-energizes. The green LEDs IN 1, IN 2 glow, if the corresponding voltage exceeds the adjusted threshold value. The green LED OUT glows, if the output voltage is higher than 3 V. 1

Control module Examples of application CP-A RU with for monitoring of two power supplies - In case of fault: Fault signal If both relays are de-energized, the voltages of both channels are below the adjusted threshold value (e.g. 20 V). This could mean, that both power supply units failed or are switched off, or that there is an overload on the secondary side. Momentary de-energization of the relays may be caused by inrush current of a connected load, during starting. If one of the two relays de-energizes, this can indicate that the primary power supply unit failed or is switched off, and the redundant power supply is now supplying power to the load. + - + - CP-A RU CP-S / CP-C Relay message channel 1 < 20 V + + - - Load Relay message channel 2 < 20 V CP-S / CP-C 2CDC 272 028 F0205 CP-A RU with for monitoring of one power supply - In case of fault: Transfer to an alternative power supply The following example of application shows transferring to an alternative power supply (in this example a battery) after a failure in the primary power supply unit. + - + - CP-A RU CP-S / CP-C Battery L1 N PE L N PE + + - - Load 2CDC 272 029 F0205 2

Control module Installation Mounting The module is plugged and fixed as shown in the accompanying picture onto the front side of the redundancy unit CP-A RU. Doing so, the pre-cut front foil of the redundancy unit is penetrated by the latching hooks and the plug contacts. The module must not be plugged in when the power is on. 2CDC 272 073 F0004 Demounting The module is removed as shown in the accompanying picture. The module must not be removed when the power is on. 2CDC 272 074 F0004 Electrical connection - Output side [SENSE OUT ++-] The terminals SENSE OUT + + - are situated on the + and - potential on the output side and can be used for signalling. Electrical connection - Input side [IN 1 (11-12/14) and IN 2 (21-22/24)] Message input 1 OK - Volt-free (dry/floating) change-over contact: 11-14 closed and 11-12 open, if the voltage in channel 1 (IN 1) of the CP-A RU exceeds the threshold value adjusted at IN 1 <V. 11-12 closed and 11-14 open, if the voltage in channel 1 (IN 1) of the CP-A RU drops below the threshold value adjusted at IN 1 <V. Message input 2 OK - Volt-free (dry/floating) change-over contact 21-24 closed and 21-22 open, if the voltage in channel 2 (IN 2) of the CP-A RU exceeds the threshold value adjusted at IN 2 <V. 21-22 closed and 21-24 open, if the voltage in channel 2 (IN 2) of the CP-A RU drops below the threshold value adjusted at IN 2 <V. Connecting diagram IN1 IN 2 Sense OUT + + - 11 12 21 22 14 24 12 11 14 22 21 24 2CDC 272 023 F0005 + + - SENSE OUT - on the + and - potential on the output side 11-12/14 Message input 1 (IN 1) OK - Volt-free (dry/floating) change-over contact 21-22/24 Message input 2 (IN 2) OK - Volt-free (dry/floating) change-over contact 3

Control module Technical data Data at T a = 25 C, if noting else indicated Type Input circuit 11-12/14, 21-22/24 Rated input voltage U IN 24 V DC Input voltage range 13-30 V Power consumption at 24 V DC approx. 1 W Measuring circuit 11-12/14, 21-22/24 Monitoring function undervoltage monitoring Measuring voltage rated operating voltage Thresholds 14-28 V Accuracy, tolerance 10 % of full-scale value Hysteresis related to the threshold fix 3-5 % Maximum measuring cycle 6 ms Output circuit +, +, - Kind and number of contacts relays, 2 x 1 c/o contact Contact material AgNi Operating principle closed-circuit principle Rated voltage (IEC 60947-1, VDE 0110) 250 V Minimum switching voltage 24 V Maximum switching voltage 250 V Minimum switching current 10 ma Maximum switching current 1 A Rated current AC12 (resistive) 230 V 1 A (IEC 60947-5-1) AC15 (inductive) 230 V 1 A DC12 (resistive) 24 V 1 A DC13 (inductive) 24 V 1 A Maximum lifetime mechanical 30 x 10 6 switching cycles electrical 0.1 x 10 6 switching cycles Short-circuit capacity / n/c contact 2 A fast acting maximum fuse rating n/o contact 2 A fast acting Indication of operational states IN 1: green LED voltage at input 1 > than threshold 1 = no faults present IN 2: green LED voltage at input 2 > than threshold 2 = no faults present OUT: green LED U OUT > 3 V = no faults present General data Duty time 100 % Dimensions W x H x D (when mounted) 56.5 mm x 54 mm x 24 mm (2.22 inches x 2.13 inches x 0.94 inches) Weight 0.063 kg (0.14 lb) Degree of protection enclosure / terminals IP 20 / IP 20 Material of enclosure UL94V0 Protection class II Mounting, mounting position plugged onto redundancy unit Fastening snap-on mounting, without any tool 4

Control module Technical data (continued) Electrical conection Wire size fine-strand with wire end ferrule 0.2-2.5 mm 2 (22-14 AWG) fine-strand without wire end ferrule 0.2-2.5 mm 2 (22-14 AWG) rigid 0.2-4 mm 2 (22-12 AWG) Stripping lenght 7.5 mm (0.295 inches) Torque 0.4-0.6 Nm Environmental data Temperature range operation -25...+70 C storage -40...+85 C Humidity (IEC 60068-2-3) 93 % at 40 C, no condensation Climatic category (EN 60721) 3K3 Vibration (IEC 68-2-6) 1-57 Hz, amplitude 0.075 mm / 57-100 Hz, 5 g Shock (IEC 68-2-27) 30 g all directions Isolation data Rated insulation voltage 250 V (IEC 60947-1, EN 50178, VDE 0160) Rated impulse withstand voltage U imp between all circuits 2.5 kv (type test) (IEC 664, VDE 0110) Power-frequency withstand voltage test between all circuits 1.2 kv AC (routine test) Protective seperation (EN 50178) between input and output Pollution degree (EN 60950) 2 Overvoltage categorie (EN 60950) 2 Dimensions in mm 54 2.13 56,5 2.22 24 0.94 2CDC 272 006 F0b05 5

Subject to change without prior notice. All statements serve exclusively to describe the product and have not to be understood as assured characteristics with legal force. Publication No. 2CDC 114 037 D0201 (03/06) ABB STOTZ-KONTAKT GmbH Eppelheimer Straße 82 69123 Heidelberg, Germany Postfach 10 16 80 69006 Heidelberg, Germany Internet http://www.abb.com/lowvoltage Control Products Electronic Relays E-Mail epr-support@stotzkontakt.de You can find the address of your local sales organisation on the ABB home http://www.abb.com/contacts Low Voltage products