Operating instructions II / 2004

Similar documents
luxcontrol lighting control system basicdim basicdim ILD 16DPI 69f Compact control module with ambient light sensor and motion sensor

Short operating instructions

Data sheet. Function description. Benefits

luxcontrol lighting control system DALI sensors basicdim RCL DBC Control module for combination with ambient light sensor, switch and presence sensor

EBDSM-PRM Product Guide

luxcontrol lighting control system DSI sensors smartdim SM lp Control module for combination with ambient light sensor, switch or presence sensor

luxcontrol DALI MSensor 5DPI 14 Product Manual

Switch actuator. Movement detector Move/monitoring 1305/1.0, Art. No , ,

MOTION DETECTOR WITH CONSTANT LIGHT CONTROL DM KNT 003

Light Management Systems for Indoor Use MULTISENSORS

OT FIT 15/ /500 LT2 LP

EBDSPIR-AT-DD. RF ceiling PIR presence detector DALI / DSI dimming. Product Guide. Overview. Features

The universal input/output device is a DIN rail mounted device. It is connected to the EIB via a bus connecting terminal.

Radio motion detector comfort 1.1 m/2.2 m quicklink Order number

Radio bus system Radio-universal dimming actuator, 1-gang. 1 Safety instructions. 2 Device components. Order-No. : Operating instructions

1 Safety instructions. 2 Device components. Radio bus system. Radio socket outlet adapter for dimming Order No. : Operating instructions

ABB i-bus EIB Light controller LR/S and light sensor LF/U 1.1

KNX manual 1-channel flush-mounted switch actuator SU 1

Rev ABB i-bus KNX 6151/11 U-500. Power and productivity for a better world TM

Product Manual. ABB i-bus EIB / KNX. Universal Interface US/U Intelligent Installation Systems

FL ballasts Electronic dimming. PCA T8 ECO lp Y, 3x18 W and 4x18 W ECO T8

Human Centric Lighting System

FL ballasts Electronic dimming. PCA T5 ECO lp Y, 3x14/24 W and 4x14/24 W ECO T5

LCC1653, LCC1656, LRI1653 Datasheet ActiLume DALI System

Fixture Built-in Sensor Daylight Harvest Version

Product and Applications Description

Electrical devices may only be mounted and connected by electrically skilled persons.

PCA ECO lp Y, W T8 fluorescent lamps

Data sheet. Constant current LED control gear 26 W, 350 / 500 / 700 ma, DALI, 1 10 V Intelligent temperature protection SELV output.

RoHS. Electronic ballasts for dimming to 1 % Linear lamps T5, 16 mm high efficiency, high output

RF Wireless Version On/off Control

Product Specification

FL ballasts Electronic dimming. PCA T8 ECO lp Y II, W ECO T8

Technical data: Instabus EIB supply Voltage: YY 6 x 0.6 mm; red: bus (+) / black: bus (-)

EBDHS-MB-AT-DD. RF ceiling PIR presence detector DALI / DSI dimming. Product Guide. Overview. Features

EC5401B. B-Tronic EasyControl. Assembly and Operating Instructions. Wall/hand-held transmitter, 1-channel, bidirectional

Universal Radio Cord Dimmer Order No.: Function

1: White buttons Used by the user on a daily basis. 2: Grey buttons Used only upon first startup.

OPTOTRONIC Intelligent

BossDim RS. User manual - UK

Installer manual inputs/outputs interface for led KNX

animeo KNX/EIB 4 AC Motor Controller WM/DRM V AC

Width (W): 44 mm. bus connecting and branching terminal External supply --- Inputs: Number: up to 2 (depending on parameterization: channel 1 to 2)

Technical data lumina MS4/RC

instabus EIB product documentation

L DN 2810 FL DE 3925 L DN 2810 FL PIR DE 3925 L DN 5630 FL DE 3925 L DN 5630 FL PIR DE 3925 L DN 9850 FL DE 3925 L DN 9850 FL PIR DE 3925

ActiLume G2 Indus Sensor H513

FL ballasts Electronic dimming. PCA T5 EXCITE lp Y, 3 and 4x14/24 W EXCITE T5

Instruction manual. art Installation manual

IMPORTANT SAFEGUARDS READ AND FOLLOW ALL SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE

ABB i-bus KNX DALI Light Controller DLR/S M Product Manual

ActiLume 1-10V. OEM application guide

SeeTool - Solutions for KNX

FSP-211 DIGITAL HIGH/LOW PIR FIXTURE INTEGRATED SENSOR

SIMPLUX Standalone Wireless Lighting Control System Setup guide Light is OSRAM

Electrical devices may only be mounted and connected by electrically skilled persons.

RF ceiling microwave presence detector DALI / DSI

RAIL MOUNTED NETWORK METER TYPE N27D USER S MANUAL

Operating instructions Flat-Type Wall-Mounted Radio Control

LLC1681, LRI1655 Datasheet ActiLume Wireless 1-10V system

Wireless wall transmitter, 1-gang with inscription space, Wireless wall transmitter, 3-gang with inscription space

1 Safety instructions. 2 Device components. 3 Function. Radio bus system. Radio socket-outlet adapter for switching Order No. :

EBDHS-AT-DD. RF ceiling PIR presence detector DALI / DSI dimming. Product Guide. Overview. Features

ABB i-bus KNX DALI-Light Controller DLR/A Product Manual

NOVA series Ceiling lights with tuneable white Colour temperature 2700 to 6500 K. Detailed operating instructions

OTi DALI 80/ / CH OTi DALI 50/ / CH

QL50 Luminescence Sensor

B-Tronic EasyControl EC5401B

Product Catalog 2013 Made in EU

ZITARES CCD FX-20 25W SELV (isolated), adjustable functions and current, 1-channel, dimmable

PHASED OUT. Digital dimmable ballasts for fluorescent lamps EXCEL series. PCA TCL EXCEL one4all lp Y, 55 W Compact and T5c fluorescent lamps

design by Antonio Citterio with Toan Nguyen

The room thermostat application module with 2-fold switch sensor is placed on a flush-mounted bus coupler.

Single-colour Dimming: Hand-held Transmitter 2801E Data Sheet

ZITARES CCD 2 nd Generation SELV constant current control gear, 1-channel, dimm- and adjustable

animeo KNX 4 DC 2 A Motor Controller WM 24 V DC Installation manual

TD - Power Supply LP DALI&Switch Dim Mono PRE (CV) MM-IP20 User Manual

luxcontrol lighting control system Sensors smartswitch 5DP 14f Automatic switching based on presence and light level

IRIS \ IRIS-I QUICK SET-UP GUIDE STEP 1 INSTALL

3000W multi Pir light controller

Applications. HBT02 Transceiver Node. Features. Note: This datasheet is intended for information related to the hardware only.

already there. LUMILUX T8 Subheadline

Philips Ledalite Phone: Fax: Web: Programming Guide Version 2.0

ZITARES ICD SELV constant current control gear, 2-channel, dimm- and programmable

High/Low Bay Passive Infrared Occupancy Sensor

Binary Inputs. Ref.-No. KNX universal binary input, 8-gang. ETS-product family: Series embodiment (SE-) device (2 units) Ref.-No.

ABB i-bus KNX Weather Sensor, SM WES/A 3.1, 2CDG120046R0011

Dialight Daylight Harvesting Sensor User Guide

Heat pipe technology to cool LEDs. Powerful light, precisely where you need it.

Shutter Actuator with Manual Operation, 4-fold, 230 V AC, MDRC JA/S M, GH Q R0111. ABB i-bus EIB / KNX

Automatic-switch (1,10m): Standard attachment Order No.: Automatic-switch (2,20m): Standard attachment Order No.:

FL ballasts Electronic dimming. PCA T8 EXCEL one4all lp Y II, W EXCEL T8

UMG 96L / UMG 96. UMG 96L / UMG 96 Universal measurement device. Threshold value monitoring. Pulse outputs. Networks TN-, TT-Networks

KNX ENO 620/622 (32-channel AP)

ZITARES ICD SELV constant current control gear, 2-channel, dimm- and programmable

Radio Touch Order no.: 2880 xx. Operation and installation instructions. 1 Safety instructions. 2 Structure of the device (Figure 1) Radio Touch

ZoneLite setup remote handset. Daylight Linking & Daylight Dependency control

E N SHT-1 SHT-1/2 SHT-3 SHT-3/2

Electrical devices may only be mounted and connected by electrically skilled persons.

LK Wireless Room Control Cq

Transcription:

Operating instructions II / 2004 Light and presence sensor TOUCH DIM LS/PD LI OSRAM GmbH Costumer-Service-Center (CSC) Steinerne Furt 62 86167 Augsburg, Germany www.osram.com www.osram.de Tel. : (+49) 1803 / 677-200 (charges apply) Fax.: (+49) 1803 / 677-202

General Contents General Installation Operation Appendix Application and function...2 Design and dimensions...3 Wiring diagram...3 Installation hints...4 General functions...5 Controlling brightness at the workplace...5 Troubleshooting...7 Technical data...8 Application and function The TOUCH DIM LS/PD LI sensor was developed to regulate and control the brightness at workplaces. The sensor measures the brightness and detects the presence of persons. The lighting conditions at the workplace are maintained at a user-adjustable set point by providing artificial light according to the amount of available daylight. If there is more than sufficient daylight, the connected luminaries are switched off. The TOUCH DIM sensor can be installed in luminaires (e.g. floor-standing luminaires), or by use of a flush device box with adequate cover also into the ceiling. Good workplace lighting makes the working environment more comfortable. Energy savings of up to 70% can be made compared with conventional workplace lighting. Safety and installation information The unit should be installed and tested only by a qualified electrician. Power to the units must be switched off before any work is undertaken. The relevant safety and accident prevention regulations must be observed. The TOUCH DIM sensor is used exclusively for controlling electronic control gear type QUICKTRONIC INTELLIGENT LI (QTi LI...DIM) or HALOTRONIC INTELLIGENT LI (HTi LI..DIM). No further control units may be operated on the control line. Other applications are not permitted. They may destroy the TOUCH DIM LS/PD LI and other equipment. The maximal number of ECG and the maximal overall cable length between push button, sensor and ECG has to be respected (see Technical data). If the control cable is wired with external voltage, the unit may be destroyed. The TOUCH DIM Sensor may only be supplied with AC operating voltage. This is particularly important to remember if UPS systems are used. page 2 OSRAM - operating instructions TOUCH DIM LS/PD LI

Installation Design and dimensions Wiring diagram L N PE Push button (manual control) L N S TOUCH DIM Sensor signal wire length max. 10m ECG QTi LI ECG QTi LI ECG QTi LI 1 2 3 4 1 2 3 4 1 2 3 4 Lamp Lamp Lamp max. 4 QTi ECG or HTi transform ers Push button and sensor have to be connected to the same mains phase! ECG QTi LI 1 2 3 4 Lamp OSRAM - operating instructions TOUCH DIM LS/PD LI page 3

Installation Installation hints The sensor is connected to a 3 wire cable which is admitted for mains voltage. Parallel connection of several sensors is not allowed. The sensor is typically installed in luminaires, ceiling installation is possible by use of a flush device box and an adequate cover. A sensor has a detection angle of approx. 80...100. If it is installed at a height of 3 m, it can mo nitor an area with a maximum diameter of 5-7 m. When installing the sensor, please note the following: The entire workplace must lie within the monitoring cone of the sensor. Avoid placing the sensor where it is directly exposed to light from other sources as this will lead to incorrect measurements. The sensor should be installed centrally in the sphere of action, so that all controlled lumnaires contribute with the same proportion to the measured brightness. The sensor must not be exposed to drafts (e.g. near air vents). A draft could be misinterpreted as the presence of a person in the room. Example: Office with 4 controlled luminaires: window controlled luminaire controlled luminaire possible place of installation window controlled luminaire controlled luminaire optimal place of installation Touch DIM Sensor 2m window min. 40 1m Height above window sill 0m 1m min. distance to window 2m 0m Diagram: minimal distance to windows page 4 OSRAM - operating instructions TOUCH DIM LS/PD LI

Operation General functions Switching the luminaire on/off 1. Briefly press the switch once. The luminaire is switched on or off each time the switch is operated. Changing the brightness With the luminaire switched off: 1. Press the switch. Keep pressing the switch until the required brightness is reached. With the luminaire switched on: 1. Press the switch. Keep pressing the switch until the required brightness is reached. The luminaire goes on at minimum brightness. The longer the switch is pressed, the brighter the luminaire gets. When the switch is released the luminaire will remain at the brightness it has reached. The brightness will change. When the switch is released the luminaire will remain at the brightness it has reached. Switching between more and less brightness: 2. Release the switch then press it again. Keep pressing the switch until the required brightness is reached. Every time the switch is held down the unit toggles between more light and less light. Note: Changing the brightness deactivates brightness control. When the unit is switched on again brightness control is reactivated, if a set point value was is stored. Controlling brightness at the workplace Switching the luminaire on and off automatically If the motion detector does not detect movement for 15 minutes, the lighting control unit will reduce the brightness level to the minimum value and then switch off the luminaire. As soon as motion is detected the luminaire will be switched on again, provided that artificial light is needed. If natural daylight is more than max. range of operation, the lighting control unit will switch off the luminaire. To avoid unnecessary and disturbing switching of the lamps, the light is switched off with a delay of approx. 15 minutes. If the brightness at the workplace gets less and persons are present, the lighting control unit will switch on the luminaire again and control the brightness. Adjustment / Storage of the set point for brightness control 1. Change the brightness to the required level by holding down the switch. 2. Once the set point is reached, make a double click (switch pressed twice briefly within short time) within 30 s. The brightness will change. When the switch is released the luminaire will remain at the brightness it has reached. The brightness you have just set will be stored as the new set point. The luminaire will flash twice to confirm that this value has been stored. OSRAM - operating instructions TOUCH DIM LS/PD LI page 5

Operation Switching off at the switch, switching on via motion detection If the luminaire is has been switched off at the switch, then it will not be switched on automatically via the motion detector until an interval of 60s without movement has elapsed. Every further detected movement within this time retriggers the interval. After this interval the next detected motion will switch on the luminaire, provided that artificial light is needed. Deactivation of the brightness control Brightness control can be completely deactivated: 1. If the luminaire is switched on, switch off the luminaire by briefly pressing the switch. 2. Make a double click (switch pressed twice briefly within short time). The set point is erased and brightness control is now disabled. To activate the brightness control again, store a new set point as described on the previous page. Deactivation of the motion detection / Holiday mode If desired the motion detection can be deactivated. The brightness must not be manually changed 30 seconds before this holiday mode is activated. 1. Make a double click (switch pressed twice briefly within short time) The luminaire is switched off. Motion detection is deactivated until the luminaire is switched on again at the switch. page 6 OSRAM - operating instructions TOUCH DIM LS/PD LI

Appendix Troubleshooting The luminaire is not working. Possible cause: There is no power. Check if the luminaire is connected to power. The lamps are faulty. Replace them. The luminaire was switched off at the switch. Switch the luminaire on. The sensor is overexposed to ambient light. Cover the sensor and observe how the luminaire behaves. The luminaire is not regulating its brightness to the set point. Possible cause: After setting the brightness you must press the switch twice within 30 seconds. If you press the switch later you will activate holiday mode. Bear this time in mind. Brightness control is not started until 5 seconds after the set point has been set. Within this time any other switch operations are ignored. Bear this time in mind. Brightness control was deactivated by changing the brightness level with the switch. Switch the luminaire off and on again. Brightness control is deactivated because set point was erased. Store a new set point. The luminaire is not switched on automatically by the motion detector. Possible cause: The luminaire was switched off less than 30 s ago at the switch. Please note: after the luminaire is switched off, motion detection is deactivated for 30s. The motion detector is not covering the workplace. Wave your hand in front of the sensor and observe how the luminaire behaves. If the luminaire reacts to the movement, realign the luminaire over the workplace. More than adequate natural daylight is available and no additional artificial light is needed. The holiday mode is active. For deactivation of the holiday mode please press the switch Holiday mode cannot be activated. Possible cause: The brightness level was changed at the switch less than 30 seconds ago. Wait at least 30 seconds after changing the brightness before activating holiday mode. The luminaire is not reacting as expected to switch operations. Possible cause: The switch is being pressed too long. Please note: Hold down the switch to change the brightness until the luminaire reaches the brightness level you want. For all other functions, just briefly press the switch. If you cannot remedy the problem, please contact the customer service department of your luminaire manufacturer. OSRAM - operating instructions TOUCH DIM LS/PD LI page 7

Appendix Technical data Designation: Operating voltage: Connections: Interface: overall length of signal connection: Power consumption: TOUCH DIM LS/PD LI, light and presence sensor 220 240V AC / 50 60Hz (no DC operation) L, N, S (signal) OSRAM specific, max. 4 QTi LI ECG or. 4 HTi transformers connectable Max. 10 m approx. 0,5 W Operating temperature: 0C...+ 50 C Adjustable light value: 10 300 lux measured at sensor resp. approx. 10-1200 lux at desk surface Presence Detection area: conical, approx. 80-100 aperture angle Pollution severity: 2 Dry, not conductive to IEC 664 CE requirement: EMC to EN 61547 Dimensions: 63 x 29 x 21mm (L x W x H) Protection class: Protection type: IP 20 II The CE symbol signifies compliance with the relevant EU Directives. page 8 OSRAM - operating instructions TOUCH DIM LS/PD LI