Operating Instructions TIC 251/252. Profibus DP-Gateway PG 0009 BE/E (0903)

Similar documents
Operating Instructions

Operating Instructions

Operating Instructions DPG 101. Vacuum Measurement And Control Gauge PG0006KJL_F (0508)

Operating Instructions PROFITEST H+E TECH. Diagnostics Unit for Electric Charging Stations (Type 2 Connector Socket and Plug) /3.

Radio receiver FS20 EAM

Wind Transmitter compact xx

Wind Transmitter - with frequency output xx.xxx

Standard Rocking Platform WT15 Code No , Manual August 2004

Precipitation Monitor ,

INSTRUCTION MANUAL. IBRit - rf1 - usb PC - Station for wireless Data transmission. M e s s t e c h n i k. Messtechnik GmbH & Co.

OPERATING INSTRUCTIONS MPT 200. Digital Pirani/Cold Cathode gauge. Translation of the original instructions PG 0025 BEN/C (1604)

Precipition Sensor with analogue Intensity Output ,

Operating Manual * * Differential pressure transmitter. Table of Contents. 1 Safety guidelines. 1.1 General Information

Wind Transmitter - compact

Standard Power Pack P25T Order-No Manual May 2009

Operating Instructions for Pressure Sensor with Ceramic Sensor Element. Model: SEN-9601

RMO500 M I C R O O H M M E T E R

RAD-IN/OUT-8D. Digital extension modules for the bidirectional wireless system. INTERFACE Data sheet _en_05. 1 Description

Wind Transmitter - with analogue output xxx

SIMATIC ET 200SP. Digital input module DI 8xNAMUR (6ES7131-6TF00-0CA0) Manual. Answers for industry.

Installation guide 873 SmartRadar Control Unit & Antenna Unit

PU202 Level converter & encoder signal generator without potential separation

Operating Instructions K-POWERgrip EWL Always on the safe site.

Out 1 sin / cos 1Vpp. sin / cos 1Vpp. Out 3. sin / cos 1Vpp. Out 4 sin / cos 1Vpp. Interface type SV211 SinCos signal splitter with 4 SinCos outputs

TETRIS 1000 High Impedance Active Probe. Instruction Manual

BL20 Redundant power supply BL20-BR-24VDC-RED

Wind Direction Transmitter First Class analogue output x0.1xx

Wind Direction Transmitter - compact - with Poti Output xx.712

Radio System Strobe Wizard Plus Freemask

Original operating instructions Fail-safe inductive sensor GG507S / / 2013

SIMATIC Vision Sensor SIMATIC VS130-2 and VS 130-2vcr

Magnetic Inductive Flow Sensor induq

SUNNY BEAM REPEATER Transmission Range Increase for Sunny Beam

Accessories Solar Datatechnology Wireless-Set485-01/-Set485-02

Original operating instructions Fail-safe inductive sensor GM705S

Original operating instructions Fail-safe inductive sensor GM504S / / 2010

USER S MANUAL POWER SUPPLY - ISOLATOR - SIGNAL CONVERTER ZSP 41 POWER SUPPLY - ISOLATOR - SIGNAL CONVERTER SIGNAL MULTIPLIER ZSP 41/2

2-/4-Channel flush-mounted transmitter FS20 S4U

Original operating instructions Fail-safe inductive sensor GG507S

Original instructions INCA-1 Tina Emergency stop for enclosure installation INCA-1S Tina Safety stop for enclosure installation

Operator Manual. Transmitters Series KAT-... Analog transmitters in 2-wire technique

Cable Identifying Generator LCI TX / LCI TX-440

WARNING Improper operation may result in serious personal injury CAUTION

For detailed specifications and ordering info go to

OPERATION MANUAL ELECTRONIC FREQUENCY CONVERTER HFO-E

TURBO.DRIVE S. Operating Instructions GA /4.02. Frequency Converter for Turbomolecular Pumps. Part No Vxxxx

Wind Direction Transmitter - compact - GMR, analogue output xxx xxx

IQ SENSOR NET MIQ/MC(-A)-RS

Instruction manual for STA 1 sectional door operator

Wind Transmitter First Class Advanced Classified according to IEC ( )

Top spin Nr /

Amplifier Series BASIC. Installation & Operations Manual

DB 12 B. Double Sheet Testing Unit. Phone: Fax: Web: -

OPERATION MANUAL ELECTRONIC FREQUENCY CONVERTER HFO E

Installation guide 877 FDI Field Display & Interface

TETRIS User's Guide. High Impedance Active Probe DO177-1

DB 112 B. Double Sheet Testing Unit TECHNICAL DESCRIPTION. en / We reserve the right to. make technical changes

Operating instructions Fail-safe delay timer AZS About this document. Content

Installation Instructions RF-identification system Read/write head ANT513

Wind Direction Transmitter - compact - TMR, analogue output x.xxx xxx

Operator's Manual PCU400. Perforation Cutter. Made in Germany

Melt pressure Transmitter GREENLINE Type DTAI with Temperature element

IONIVAC ITR 200 S, ITR 200 SL ITR 200 SP, ITR 200 SD. Operating Manual _002_C0. Dual Filament Bayard-Alpert Pirani Transmitter

Model 5100F. Advanced Test Equipment Rentals ATEC (2832) OWNER S MANUAL RF POWER AMPLIFIER

Installation guide 971 SmartRadar LTi

SCHMIDT Flow Sensor SS 25.60

OPERATION MANUAL. Input Block EX250-IE1 EX250-IE2 EX250-IE3

CT238A. AC/DC Current Probe. User Manual. For detailed specifications and ordering info go to

SIMATIC Ident RFID systems ANT 3 Compact Operating Instructions

MU110-16R(K) Digital output module 16 channel. User guide

MV110-8AS. Analog input module 8 channel. User guide

High power radio transmission module MR03 type

Installation Instructions RF-identification system Read/write head DTM434 DTM435 DTM436 DTM437

Thank you for purchasing S100 Profibus-DP Communication Module SAFETY PRECAUTIONS

Circuit Breaker Finder

VFSC9 ELECTRONIC SPEED CONTROLLER. Mounting and operating instructions

Installation Instructions RF identification system Read/write head ANT430 ANT431

Radio to radio repeater. airrepeater INSTRUCTIONS MANUAL M A

3B SCIENTIFIC PHYSICS

PZ292EN 9/28/2018. User Manual P PIREST ACTIVE SHIM

Safety instructions and installation

RSMFX-2R MULTIFUNCTIONAL

Instruction manual for STA 1 sectional door operator

Robot e.do. Safety requirements and technical specifications. Rel axes and 6 axes versions

Instruction Manual MSC710 MSC710-U MSC710-I

VIESMANN. Installation and service instructions VITOTROL 300 RF. for contractors. Vitotrol 300 RF

SPLIT.CONVERTER. User's Manual. Version 2.0

PM-311x Quick Start Ver PM-311x introduction 1.1. Caution & Warning 1.2. Product Warranty & Customer Support

Operating Instructions / Voltage Tester per IEC with Phase and Polarity Tester and Phase Sequence Indicator

INSTRUCTION MONO POWER AMPLIFIER CHALLENGER 250. We congratulate you with the purchase of this superb AUDIOVALVE HiFi component.

Operating manual GTL 241 GTL 251. Temperature probe. Please keep the manual for future use.

Baro Transmitter PTB x1.073

MU110-8R(K) Digital output module 8 channel. User guide

Operating Manual. GV210 Encoder distributor, cross switcher and splitter for incremental encoder signals. Product Features:

TPM + Lenze ECS. Quick Startup Guide D Revision: 02

Operating Instructions

2-WIRE UNIVERSAL TEMPERATURE TRANSMITTER

Signal converter for electromagnetic flowmeters

Knife grinding machine K3 H/K

FOLDING MACHINE PF-45A OPERATOR MANUAL 1. FUNCTION

Transcription:

Operating Instructions TIC 251/252 Profibus DP-Gateway PG 0009 BE/E (0903)

Contents Page 1. Safety Precautions... 3 2. Understanding The TIC 251/252... 4 2.1. For Your Orientation... 4 Delivery Consignment... 4 2.2. Product Description... 4 Connection Options... 4 Proper Use... 5 Improper Use... 5 3. Installation... 5 3.1. Preparations For Installation... 5 3.2. Interface To The Transmitter... 5 3.3. Profibus-DP-Connection... 6 3.4. Voltage Supply... 6 4. Operations... 7 4.1. Adjustment Of The Profibus Interface Addresses... 7 4.2. Illuminating Displays... 8 4.3. Data Transfer... 9 4.4. Activating DeGas (only at HPT 100 with TIC 252)... 10 4.5. Adjustment Of the Correction Factors (not at CPT 100 with TIC 251)... 10 4.6. Adjustment Of The Pressure... 10 4.7. Selecting Switching Ranges (only RPT/MPT/HPT 100)... 10 5. What To Do In The Case Of Breakdowns?... 11 6. Maintanance, Service... 11 7. Technical Data... 12 7.1. Data List... 12 7.2. Dimensions Diagram... 12 8. Supplementary Informationen... 13 Manufacturer s Declaration...Annex 1 2

1. Safety Precautions Read and follow all the instructions in this manual. Inform yourself regarding: - Hazards which can be caused by the unit, - Hazards which can arise in your system, Comply with all safety and accident prevention regulations. Check regularly that all safety requirements are being complied with. Take account of the ambient conditions when installing the TIC 251/252. The protection type is IP20. The unit is protected against the ingress of foreign bodies ø 12 mm. Because water protection is not provided the unit must be fitted into a suitable housing. Do not carry out any unauthorised conversions or modifications on the unit. Do not open the housing cover when the unit is connected to the mains nor during pumping operation. Take account of the prescribed voltage when connecting the cable to the various plugs. When returning the unit to us please note the shipping instructions. Pictogram Definitions WARNING Warning! Danger of personal injury. CAUTION Caution! Danger of damage to the unit or system. PLEASE NOTE Please Note. Important information on the product, its usage or part of the documentation which requires particular attention. 3

2. Understanding The TIC 251/252 2.1. To Your Orientation Abbreviations Used TIC = Gateway Operating instructions In The Text Here, you have to do something. Delivery Consignment The following positions are included on the TIC 251/252 delivery: TIC 251 respectively TIC 252 A plug connector for the voltage supply A CD with the GSD file. 2.2. Product Description The TIC 251 / TIC 252 is a gateway which enables the connection of vacuum transmitters to the Profibus DP. For this, each a TIC 251 / TIC 252 is necessary per transmitter. Gateway TIC 251 TIC 252 Transmitter, applicable PPT100, CPT100, RPT100 HPT100, MPT 100 2 TIC 251/252 3 4 1 Connection to Profibus-DP 2 Connection to voltage supply TIC 251/252 and transmitter 3 Connection to transmitter (rear side) 4 Illuminating displays 5 Address selector switches 6 Rubber stoppers for address selector switches 5 1 4 6 Connecting Options The TIC 251/252 is prepared for the following connections: Voltage supply Profibus-DP Transmitter 4

Proper Use The TIC 251 serves exclusively for the connection of a Vacuum Transmitter CPT 100, PPT 100 and RPT 100, the TIC 252 of the Vacuum Transmitter HPT 100 and MPT 100 to the Profibus DP. Improper Use Improper is: Uses not covered above, and, in particular, Connection to units which is not permitted in their operating instructions. Connection to units which contain touchable and voltage carrying parts. Improper use will cause any rights regarding liability and guarantees to be forfeited. 3. Installation 3.1. Preparations For Installation Unauthorised modifications or alterations to the unit are not allowed. WARNING Installation location: Protected against the weather. Temperature: +5 C - +40 C. Relative humidity: max. 80 %, at T 31 C Atmospheric pressure: 86 kpa - 106 kpa Installation height: max. 2000 m Pollution level: 2 To fit, plug the TIC 251/252 onto the transmitter and screw tight the two hexagonal bolts. Set the serial interface address of the transmitter to "RS232". Connect the Profibus DP in accordance with the regulations. The TIC 251/252 and the transmitter are supplied with voltage as soon as adequate voltage is made available (please refer to Section. 3.4.). 3.2. Serial Interface To The Transmitter Voltage supply for the transmitter and the communication is effected with the fitting of the TIC 251/252 via the D-Sub socket. 5

3.3. Profibus-DP-Connection 5 4 3 2 1 9 8 7 6 pin Function 1 Shield 2 not connected 3 RxD/TxD-P 4 CNTR-P 5 DGND 6 VP 7 not connected 8 RxD/TxD-N 9 not connected 3.4. Voltage Supply The plug for the supply of voltage on the transmitter should be arranged as follows: Top view to the plug a b c d +24V not connected not connected gnd 6

4. Operation 4.1. Setting The Profibus Serial Interface Address The Profibus address is set up with the address selector switch using hexadecimal coding. For conversion of decimal to hexadecimal addresses please refer to the table below. Afterwards fit the rubber stoppers to the address selector switches so as to attain the type of protection stated. Profibus-DP address (hexadecimal): Conversion to decimal data, ➀: address msd, ➁: address lsd ➀➁ Adr. ➀➁ Adr. ➀➁ Adr. ➀➁ Adr. ➀➁ Adr. ➀➁ Adr. ➀➁ Adr. ➀➁ Adr. hex. dez. hex. dez. hex. dez. hex. dez. hex. dez. hex. dez. hex. dez. hex. dez. 00 0 10 16 20 32 30 48 40 64 50 80 60 96 70 112 01 1 11 17 21 33 31 49 41 65 51 81 61 97 71 113 02 2 12 18 22 34 32 50 42 66 52 82 62 98 72 114 03 3 13 19 23 35 33 51 43 67 53 83 63 99 73 115 04 4 14 20 24 36 34 52 44 68 54 84 64 100 74 116 05 5 15 21 25 37 35 53 45 69 55 85 65 101 75 117 06 6 16 22 26 38 36 54 46 70 56 86 66 102 76 118 07 7 17 23 27 39 37 55 47 71 57 87 67 103 77 119 08 8 18 24 28 40 38 56 48 72 58 88 68 104 78 120 09 9 19 25 29 41 39 57 49 73 59 89 69 105 79 121 0A 10 1A 26 2A 42 3A 58 4A 74 5A 90 6A 106 7A 122 0B 11 1B 27 2B 43 3B 59 4B 75 5B 91 6B 107 7B 123 0C 12 1C 28 2C 44 3C 60 4C 76 5C 92 6C 108 7C 124 0D 13 1D 29 2D 45 3D 61 4D 77 5D 93 6D 109 7D 125 0E 14 1E 30 2E 46 3E 62 4E 78 5E 94 6E 110 7E 125 0F 15 1F 31 2F 47 3F 63 4F 79 5F 95 6F 111 7F 125 7

4.2. Illuminating Displays LED "TIC 251/252" status Status Off Green illuminating Red flashing Red illuminating Red 1 x short, 1 x long flashing Definition Unit is not supplied with adequate voltage Communication with the transmitter running Communication with the transmitter is defective TIC 251/252 defective Unknown transmitter connected LED "Profibus-DP status" Status Off Green illuminating Green flashing Red illuminating Red flashing Red 1 x short, 1 x long flashing Definition Unit is not supplied with adequate voltage Unit is correctly parametered and configured Unit is not yet parametered and configured The set address is invalid No bus traffic detected Current parameter data are erroneous LED "data ex" Status Off Green illuminating Definition The unit is not in the "data exchange" mode The unit is in the "data exchange" mode 8

4.3. Data Transfer The TIC 251/252 delivers six bytes of input data and anticipates nine bytes of output data grouped as follows: Input data (Transmitter -> Profibus Master) byte 0 1 2 3 4 5 a b c d e f g h i j k l m bit 7 6 5 4 3 2 1 0 a-d: Actual pressure value in the format IEEE 754 e: Value range undershooting at actual pressure value (0=no, 1=yes) f: Value range exceeded at actual pressure value (0=no, 1=yes) g: Invalid command (0=no, 1=yes) h: Value range violation with a correction factor BA (only HPT 100, 0=no, 1=yes) i: Value range violation with a correction factor Pi (not on the CPT 100, 0=no, 1=yes) j: 0=required command not supported, 1=command is supported k: Value range violation in data field for the output data (n-q) (0=no, 1=yes) l: 0=DeGas mode inactive and filament switched on, 1=DeGas mode active or filament switched off (DeGas mode only for HPT 100, filament off only for HPT 100 and MPT 100) m: Confirmation of the command Output data (Profibus Master -> Transmitter) byte 0 1 2 3 4 5 6 7 8 n o p q r s t u v n-q: Data for pressure adjustment value in the format IEEE 754 r: Command: 0: no command 1: activate DeGas (only HPT 100) 2: adjust low pressure, data (n-q) contains actual pressure value 3: adjust high pressure, data (n-q) contains actual pressure value 4: aransmit the correction factors 5: Filament off (only for HPT 100/MPT 100) 6: Filament on (only for HPT 100/MPT 100) s-t: Correction factor Pi (not on the CPT 100, 1-800 corresponds with 0,01-8,00), s=high byte, t=low byte (Motorola format) u-v: Correction factor BA/KK (only HPT 100/MPT 100, 1-800 corresponds with 0,01-800), u=high byte, v=low byte (Motorola format) Diagnostic data byte 0 1 2 3 4 Länge+spec status type slot number specifier e d c b a bit 4 3 2 1 0 a: no transmitter connected b: Sensor defective c: e2prom defective d: wrong transmitter e: Version malfunction 9

4.4. Activating DeGas (only on the HPT 100) Write the command "0" in the field r (byte 4) of the output data (in the event it is not yet "0"). Write the command "1" in the field r (byte 4) of the output data. -> Whether DeGas is active is identifiable in the field Feld l (byte 4, bit 0) of the input data. 4.5. Setting The Correction Factors (not with the CPT 100) Write the command "0" in the field r (byte 4) of the output data (in the event it is not yet "0"). Enter the correction factor in the field s-t (for the PPT 100, RPT 100 and HPT 100) and u-v (only on the HPT 100). Write the command "4" in the field r (byte 4) of the output data. The command "4" appears in the field m (byte 5) of the input data. -> Field i (byte 4, bit 3) of the input data is 0: Value OK. -> Field i (byte 4, bit 3) of the input data is 1: Value is faulty. 4.6. Pressure Adjustment Write the command "0" in the field r (byte 4) of the output data (in the event it is not yet "0"). Write the pressure value in IEEE754 format in the fields n-q (bytes 0-3) of the output data. Please refer to the operating instructions for the transmitter for a comparison of pressure values. Write the command "2" for low pressure or "3" for high pressure in the field r (byte 4) of the output data. The command "2" or "3" appears in the field m (byte 5) of the input data. -> Field k (byte 4, bit 1) of the input data is 0: Value OK. -> Field k (byte 4, bit 1) of the input data is 1: Value faulty. 4.7. Selecting Switching Ranges (only RPT/MPT/HPT 100) The switching characteristics of the transmitter sensors can be specified by the Pofibus prm data in the GSD file (see operating instructions of the respective transmitter). 10

5. What To Do In The Case Of Breakdowns? Problem Possible Cause Elimination No communication Faulty voltage supply Check voltage supply possible via the Profibus or insufficient power Profibus cabling faulty Check cabling and terminal resistance on the plugs 6. Maintenance And Service The unit requires no maintenance. A damp cloth can be used to wipe away any dirt which has collected on the front panel. Ensure that the unit is first disconnected from the mains power supply. Do Make Use Of Our Service Facilities. In the event that repairs are necessary a number of options are available to you to ensure any system down time is kept to a minimum: Return the unit to the manufacturer for repairs; Replace with a new value unit. Local PFEIFFER representatives can provide full details. CAUTION Repairs on customer side are not allowed. PLEASE NOTE Units returned to us for repair or maintenance are covered by our general conditions of sale and supply. 11

7. Technical Data 7.1. Data list Description Value TIC 251/252 Connection voltage V DC 21-30 Default Profibus Address 1 Power (without Transmitter) W 3,5 Perm. ambient temp. C 5-40 Max. relative humidity 1) % 5-85 Atmospheric pressure kpa 86-106 Protection type IP 20 Weight kg 0,10 / 0,12 1) non condensing at 5-40 C 7.2. Dimensions Dimensions TIC 251 Dimensions TIC 252 35 52 85 12

8. Supplementary Informationen The TIC 251 / TIC 252 gateway allowes the connection of vacuum transmitters to the Profibus-DP. Depending on the configuration of your components further operating instructions are included in the delivery consignment (please see the table). If, despite every effort by us, information on your products is missing please get in touch with your local Pfeiffer representatives or call us on the hotline shown on the back cover page. All operating instructions are also available as PDF files. The following operating instructions are available for the Digiline program: Product Definition No. operating instructions CPT 100 Rough vacuum transmitter PG 0001 BN PPT 100 Medium vacuum transmitter PG 0002 BN RPT 100 Combination vacuum transmitter PG 0003 BN HPT 100 High vacuum transmitter PG 0004 BN MPT 100 Combi vacuum transmitter PG 0017 BN 1) Number is requestable via the Pfeiffer Vacuum service. 13

Konformitätserklärung Declaration of Conformity im Sinne folgender EU-Richtlinien: pursuant to the following EU directives: - Elektromagnetische Verträglichkeit/Electromagnetic Compatibility 89/336/EWG - Niederspannung/Low Voltage 2006/95/EWG Wir bestätigen Konformität mit der EU-Richtlinie über elektromagnetische Verträglichkeit 89/336/EWG und der EU-Niederspannungsrichtlinie 73/23/EWG. We hereby certify that the product specified below is in accordance with the provision of EU Electromagentic Compatibility Directive 89/336/EEC and EU Low Voltage Directive 2006/95/EEC. Produkt/Product: TIC 251,TIC 252 Profibus Gateway Angewendete Richtlinien, harmonisierte Normen und angewendete, nationale Normen: Guidelines, harmonised standards, national standards in which have been applied: EN 61010, EN 55011, EN 50081-1, EN 50082-2, IEC 801 1-4, VDE 0843-6, EN 50170 Unterschrift/Signature: Unterschriften: Pfeiffer Vacuum GmbH Berliner Str. 43 35614 Asslar Germany (M. Bender) Geschäftsführer Managing Director (Dr. M. Wiemer) Geschäftsführer Managing Director Konf.II/2007 14

15