Fully Automatic X-ray meter kvp, dose, rate, HVL and time Extremely easy to use. Unfors ThinX RAD for Radiographic Quality Control

Similar documents
Unfors EDD-30 Radiation Protection in Fluoroscopy

RaySafe Xi. Specifications

RaySafe X2. Effortless measurements of X-ray

RaySafe Xi. User Manual

APPLICATION NOTE. RTI Electronics AB, Sweden Revision A, July kvp and time measurements with the Barracuda or Piranha on a typical dental unit

ELECTRONIC CONTROL CONCEPTS 160 Partition Street Saugerties, NY or local phone

DISC QC/QA Program for Digital Imaging Systems using the DR Radchex Plus Meter

Nuclear Associates &

Exposure Indices and Target Values in Radiography: What Are They and How Can You Use Them?

USER MANUAL. RaySafe X2. RaySafe X2 Solo

Less effort. More insight.

Dosepix Detector as kvp-meter in Radiology and Mammography: First steps

Estimation of signal transfer property for wireless digital detector in different measurement schemes

Precision Performance Power

ODYSSEY HF SERIES. ULTRA High Frequency X-Ray Technology. Precision... Performance... Power. Innovations in Digital Imaging.

GE AMX 4+ Portable X-Ray

I. PERFORMANCE OF X-RAY PRODUCTION COMPONENTS FLUOROSCOPIC ACCEPTANCE TESTING: TEST PROCEDURES & PERFORMANCE CRITERIA

Half value layer and AEC receptor dose compliance survey in Estonia

Overview of Safety Code 35

Disclosures. Outline 7/31/2017. Current Implementation Status of IEC Standard : Exposure Index (EI) for Digital Radiography

SERVICE & QUALITY CONTROL KITS

Piranha & QABrowser. Reference Manual - English - Version 4.3A. RTI article number:

Nuclear Associates

Inovision Model 451P Pressurized µr Ion Chamber Survey Meter

MILADY. Product Data. Page 1 of 8

Digital Radiography System

Cassette DR Solution. FDR D-EVO G43i. Square shaped cassette enabling enhanced operability and multipurpose use ISS. Wireless

TNT X-Ray Test Tools

Corsix R 32 Accu PRODUCT DATA

Learning Objectives: What s my motivation? (unknown screen actor) Workshop Overview

Portable Digital X-ray

Assessment of Beam Alignment, Collimation and Half Value Layer of Some Selected X-Ray Machines in Plateau State, Nigeria

OPERATOR'S MANUAL JUNE 2017

make it easy, with Ray

1.0 INTRODUCTION WARNINGS 2 DUTY CYCLE 2 STORAGE PHYSICAL DESCRIPTION 3 HIGH VOLTAGE PULSER/TUBEHEAD 3 BASE 3 BATTERY PACK 3

Specifications. 744 Users Manual

Digital Radiography : Flat Panel

History of digital imaging

AeroDR X60. Motorized X-ray System

STEREOTACTIC BREAST BIOPSY EQUIPMENT SURVEYS

Nuclear Associates

QC in Diagnostic Radiology. Main steps for a QC survey in Diagnostic Radiology

ESTABLISHING A QUALITY ASSURANCE ROUTINE FOR DIGITAL IMAGING

Quality Design Because you pay more and more attention to the look and effectiveness of your practice

X-ray Tube and Generator Basic principles and construction

Distributed by. Ecotron Anyview Series. The Intelligent C-Arm System

Indeks: WMXXCMM60 Advanced Industrial Multimeter

TNT DoseMate Dosimeter Detector

TABLE OF CONTENTS PAGE

Predicted image quality of a CMOS APS X-ray detector across a range of mammographic beam qualities

Digital Panoramic X- Ray unit. Product Data

RADIOGRAPHIC EXPOSURE

Agilent N8480 Series Thermocouple Power Sensors. Technical Overview

Measurement solutions for single-mode fibers

GE Inspection Technologies. The ISOVOLT Titan E X-ray Generator

FMT18 FLOOR MOUNTED SYSTEM

GE Sensing & Inspection Technologies. The ISOVOLT Titan E X-ray Generator

Aspire HD. Program Manual. 2nd Edition - October 2012

Keysight Technologies Essential Capabilities of EMI Receivers. Application Note

New Detectors for X-Ray Metal Thickness Measuring

CALYS 50. Field multifunction calibrator for basic use

Practical Medical Physics Session: TG-151 Dose Monitoring. August 5, 2013 Katie Hulme, M.S.

Visibility of Detail

OPERATIONS MANUAL DP-110 IN-DUCT DIGITAL PSYCHROMETER TABLE OF CONTENTS

Fluke199XRAY. Users Manual. Medical ScopeMeter

1.0 INTRODUCTION WARNINGS PHYSICAL DESCRIPTION CONTROL MODULE DESCRIPTION OF OPERATION OPERATING INSTRUCTIONS 7

CIRCLEX 0.3/0.8P324&0.6/1.2P324DK-85

Fig.2: Scanner VistaScan for image plates

PATIENT EFFECTIVE DOSES IN DIAGNOSTIC RADIOLOGY, NA

Invisible sophistication. Visible simplicity. CS Welcome to the simplicity of compact panoramic imaging

CALYS Transportable documenting multifunction calibrator with high accuracy 0.01%

CMOS X-RAY DETECTORS. for Industrial Non-Destructive Testing COMMITTED TO PEOPLE. DRIVEN BY INNOVATION.

OPERATOR'S MANUAL MARCH Golden Engineering...-- Portable X-ray Technology

Determination of the tube voltage from clinic mammographic system using two types of detectors

Introduction of a Single Chip TLD System for Patient Dosimetry

TRIAD TnT X-Ray Field Service/Calibration/QA Kit Model 10500AMT

Dawson DSM150. Digital Light Meter User s Manual

ADAE portable X ray machine Operation manual

Exposure Level Tester ELT-400

RADspeed Pro DIGITAL RADIOGRAPHIC SYSTEM. IBD-RADProAeroDR

35080M kvp Divider. Operators Manual

Veraview IC5 HD High definition, digital imaging excellence. Thinking ahead. Focused on life.

Agilent U1881A and U1882A Power Measurement Application for Agilent InfiniiVision and Infiniium Oscilloscopes

Development of new dosimeter for measuring dose distribution in CT

Veterinary Science Preparatory Training for the Veterinary Assistant. Floron C. Faries, Jr., DVM, MS

Nuclear Associates

EMC / FIELD STRENGTH Test receivers. Fast and straightforward: diagnostic and precompliance measurements with the R&S ESRP

Acceptance Testing of a Digital Breast Tomosynthesis Unit

Essential Capabilities of EMI Receivers. Application Note

Fire CR Calibration Guide

CALYS 100. Field precision documenting multifunction calibrator

IT FR R TDI CCD Image Sensor

USER MANUAL. UV AB Light Meter. Model UV505. Additional User Manual Translations available at

CALYS 75. Field documenting multifunction calibrator

Ask EuroSafe Imaging Tips & Tricks. Paediatric Imaging Working Group. Dose Management in Digital Radiography

Key words: fluoroscopy, dose-area-product, kerma-area-product, calibration of KAP meters, patient exposure

SPECIFICATION. Kilovoltage X-ray calibration system for protection and diagnostic level dosimetry. Prepared by

X-ray Tube and Generator Basic principles and construction

COMPUTED RADIOGRAPHY CHAPTER 4 EFFECTIVE USE OF CR

P R E S E N T E D B Y. K A M A R U L A M I N A B D U L L A H Dip. MED. IMG., BSc. MED. IMG. (UiTM)

Transcription:

Fully Automatic X-ray meter kvp, dose, rate, HVL and time Extremely easy to use Unfors ThinX RAD for Radiographic Quality Control

Unfors ThinX RAD No keys! No menus! Just position and expose!

Unfors ThinX RAD An easy tool for fast results The all-new Unfors ThinX RAD has been optimized to meet the need for a basic multi-parameter instrument for simultaneous measurement of dose, dose rate, kvp, HVL, exposure time and pulses. All parameters are conveniently displayed in the large LCD. The main advantage of the Unfors ThinX RAD is that it provides a fully automatic user interface. Simply, there are no keys on the Unfors ThinX RAD. No set-up. No settings. No range selection. It s all automatic. Just position and expose. Utilizing Auto ON/OFF, the Unfors ThinX RAD turns itself on when radiation is detected! With an unequalled battery life of more than 1 year, there is literally no maintenance needed. In spite of its small size, it is packed with world-leading, state-of-the-art technology to make your measurements effortless. There is no need to worry about manual corrections for added filtration. The meter uses Unfors exclusive Active Compensation to apply corrections for variations in beam filtration to both kvp and dose measurements. The Unfors ThinX RAD, being small and easy to use, is a perfect choice for radiation measurements in radiographic applications.

Immediate and effortless measurements Unfors is renowned for improving productivity and providing pocket-sized easy-to-use meters based on solid state detectors. Now, the Unfors ThinX RAD provides even more accuracy by utilizing the Active Compensation feature. Active Compensation is a proprietary feature derived from the market leading Unfors Xi technology. Multiple sensors and advanced calculations automatically determine the beam quality, thereby eliminating the need for further corrections of measured kvp and dose values. This results in a higher degree of simplicity for the user since no further corrections are needed to achieve maximum accuracy. Solid state sensor technology from Unfors equals immediate and effortless measurements. How it works The Unfors ThinX RAD is very easy to use. Simply position the meter under the X-ray beam and make one exposure. The display clearly shows all measured values. Position Expose Read out

Specifications Unfors ThinX RAD General EMC tested according to EN 61000-6-1:2001 and EN 61000-6-3:2001 Exposure needed One Power off Automatic after 2.5 min of inactivity Reset Automatic Power source 1 battery CR 2450 Battery life 2 years of typical use Read out 128 x 64 pixel LCD Size (H x W x L) 13 x 45 x 108 mm, 0.5 x 1.8 x 4.3 in Weight < 70 g, 2.5 oz kvp 45 150 kvp Resolution 0.5 kvp Uncertainty 3% Dose Resolution Uncertainty 5% 20 µgy 999 mgy at >70 kv (2.3 mr 114 R) Minimum dose at 50 kv is 100 µgy (11.4 mr) 1 µgy (0.1 mr) Dose rate 0.1 mgy/s 100 mgy/s at >70 kv (0.7 R/min 685 R/min) Minimum dose rate at 50 kv is 0.5 mgy/s (3.4 R/min) Resolution 0.01 mgy/s (0.1 R/min) Uncertainty 5% HVL Resolution Uncertainty 1.0 10.0 mm AI 0.1 mm Al 10% or 0.2 mm Al Exposure time 10 ms 10 s Uncertainty 0.5% Resolution 1 ms Bandwidth 0.5 khz Pulses Uncertainty 3 999 pulses, max 375 ms dead time between pulses. 1 pulse If the X-ray generator waveform is pulsed the Unfors ThinX RAD will also automatically display pulses. Active Compensation 0.5 mm Cu 10 mm AI Filtration The Unfors ThinX RAD comes in three models: ThinX RAD Dose, rate, kvp, HVL, time, pulses ThinX RAD kvp kvp, time, pulses ThinX RAD Dose Dose, rate, HVL, time, pulses 45 100 125 150 kv

Unfors Instruments Unfors, established in 1994 in Billdal, Sweden, is a market leading manufacturer of measuring instruments for QA and service of diagnostic X-ray equipment. While the headquarter is in Sweden we serve our international customers from our subsidiaries in USA, Germany, Singapore, India and China. Thanks to our customers acceptance of the unique Unfors Concept, we are now the leading and fastest growing company in our industry. Based on our long history of designing small and easy-to-use meters we used the best of our advanced proprietary technologies, from instruments like the Unfors Xi and the Unfors Mult-O-Meter, to design the new Unfors ThinX. Unfors 5101083-A The Unfors Concept Accurate result 10s to learn Pocket sized www.unfors.com