SINPAC Switches: Brief Operating Description. Mounting Options

Similar documents
SWF DV/DT Solutions Sinewave Filters. N52 W13670 NORTHPARK DR. MENOMONEE FALLS, WI P. (262) F. (262)

A cost effective, compact and reliable PWM drive for 1/4 through 1 HP DC applications

Spring Return DuraDrive Proportional Actuator

Ametek, Inc. Rotron Technical Products Division. 100 East Erie St., Suite 200 Kent, Ohio User's Guide. Number Revision F

Low Pass Harmonic Filters

High Frequency/Precision Drives by Design

MODEL 421 Over/Under Motor Load Monitor

S11 Adjustable Speed Drive Engineering Specification

Softstarters. Specification guide. Type PST. Low Voltage Products & Systems

SHORT FORM. Product Catalog. (800) time-mark.com

E3 Adjustable Speed Drive Engineering Specification

INSTALLATION INSTRUCTIONS FOR THE MODEL 777 ELECTRONIC OVERLOAD RELAY

Ratchet Relay. Ordering Information. Unique Ratchet Mechanism Assures Positive Alternate Transfer/Switching Operation. G4Q-jjjj

VF-nC1 Adjustable Speed Drive Engineering Specification

ELECTRONIC CONTROL OF A.C. MOTORS

SPECIFICATION, CONTROLS AND ACCESSORIES

VFD - D700 Series Specifications. The latest low-cost variable speed control solution for centrifugal pumps.

AU INSTALLATION INSTRUCTIONS. Revision B1 Rapid City, SD, USA, 02/2010 II_201A-AU_B1

Catalog 200 Contactors up to 115 A Motor Starters up to 55 kw 03/2009

CEU Certification Test Drive Road Show: TRM040-DrivesRoadShow-CEU

Dry-Type Transformers

PWM CONTROL CONNECTION (OPTION) BLU (COMMON) PWM IN (BLK) NOT USED TACHOUT (WHT) DC VOLTAGE (RED) 4X R..38 (9.7)

SixPac Series of SCR AC Controller and DC Converters

DPM - Mesta Electronics, Inc. Low Voltage Active Harmonic Filters

Non-Spring Return DuraDrive Modulating Actuator

ECET Industrial Motor Control. Variable Frequency Drives. Electronic Motor Drives

3.6. Control Relays and Timers D A M D 2. Contents. Product Overview. Catalog Number Selection. Solid-State Relays

SPECIFICATION, CONTROLS AND ACCESSORIES

Single Phase Soft Starters

Top wiring permanent magnet latching For non-motor loads, lighting, heating NEMA sizes to 300 A 2-, 3-, and 4-pole configurations

3 Circuit Theory. 3.2 Balanced Gain Stage (BGS) Input to the amplifier is balanced. The shield is isolated

FUJI Inverter. Standard Specifications

Motor Control V12-T13-2 V12-T13-72 V12-T13-76 V12-T13-87

Brown University Revised 2/1/2006 Facilities Design & Construction Requirements SECTION 16461C - DRY TYPE TRANSFORMERS

3. Contact Form A: SPST-NO

FEATURES OPTIONAL FEATURES

KNOW MORE ABOUT THE TRANSFORMERS. Glossary Transformers

IPS INTELLIGENT PUMP STARTER. Integrated Tru-power electronic motor and pump protection

Variable Transformers Product Design & Engineering Data

Rev.8.8 SSRMAN-1P SERIES USERS MANUAL SSR INTELLIGENT PHASE ANGLE CONTROL MODULE COPYRIGHT 2015 NUWAVE TECHNOLOGIES, INC.

For Immediate Delivery call KMParts.com at (866)

G6C. Miniature High Capacity Relays with SPST-NO 10A and SPST-NO + SPST-NC 8A. Model Number Legend. Application Examples.

VARIABLE FREQUENCY DRIVE SPECIFICATION

Power systems Protection course

Type Sealing Poles Contacts Rated voltage Model 5PST-NO, SPST-NC 24 VDC *1

Open Type Without Enclosure

PCB Relay. Ordering Information. SPST-NO Type Breaks 10-A Loads; SPST-NO + SPST-NC Type Breaks 8-A Load

4. Classification E: High capacity. 3. Terminal Form Blank: Tab terminals (#250 terminals) Tab terminals #250 SPST-NO

Phoenix DX Clean Power (18 Pulse) AC Drive

INSTALLATION INSTRUCTIONS FOR SYMCOM S MODEL 77C-LR-KW/HP ELECTRONIC OVERLOAD RELAY

Learning Module 20: Adjustable Frequency Drives. 101 Basic Series

BE1-32R, BE1-32 O/U DIRECTIONAL POWER RELAY

BE SURE POWER IS DISCONNECTED PRIOR TO INSALLATION! FOLLOW NATIONAL, STATE, AND LOCAL CODES! READ THESE INSTRUCTIONS ENTIRELY BEFORE INSTALLATION!

INSTALLATION INSTRUCTION Supersedes: N1.8Y (399) N1.8Y (699)

Product Data Sheet 3254 J/2H3P

ECET 211 Electrical Machines and Controls

PRODUCT / TEST MANUAL 2V162K4 VOLTAGE REGULATOR RELAY

Frequently Asked Questions (FAQs) MV1000 Drive

ELECTRIC DRIVE LAB Laboratory Manual

CI-tronic Soft start motor controller

Power PCB Relay. To Order: Select the part number and add the desired coil voltage rating (e.g., G6B-1114-US-DC6).

HG RELAYS 20 AMP POWER RELAY FEATURES SPECIFICATIONS

Installation Guide. A Regal Brand. EvergreenCM ManPROOF _Fnl.indd 1

AF91 Adjustable Frequency Drives Series B

A Subsidiary of Regal-Beloit Corporation. AC Inverter Terminology

EVERGREEN EM INSTALLATION GUIDE

Technical Information General Purpose Relays

The GS1 Digital Keypad LED Display Function Keys Displaying the Status of the GS1 AC Drive Programming the GS1 AC Drive...

Conventional Paper-II-2011 Part-1A

CHAPTER KEYPAD OPERATION AND QUICKSTART. In This Chapter... The GS2 Digital Keypad GS2 Quickstart...3 6

Technical Instructions Document No EA GQD October 25, OpenAir GQD Series

An American Control Electronics Brand PCM4 SERIES USER MANUAL PCM4.

PCB Relay SPST-NO G6CU-1117P-US G6CU-1114P-US G6CU-1117C-US G6CU-1114C-US SPST-NO + SPST- G6CU-2117P-US G6CU-2114P-US G6CU-2117C-US G6CU-2114C-US

INSTRUCTIONS YASKAWA. Upon receipt of the product and prior to initial operation, read these instructions thoroughly, and retain for future reference.

High switching capacity 1a/1c 30A power relays

Power-Sure 700. Technical Data TD158001EN. Contents

G5NB. A Miniature Relay with 1-pole 3A/5A Switching Capability and 10 kv Impulse Withstand Voltage. Application Examples. Model Number Legend

D1238B12B9AP-00 D1238B24B9AS-00 D1238B24B9AP-00 D1238B48B9AS-00 D1238B48B9AP-00 D1238B12B8AP-00 D1238B24B8AS-00 D1238B48B8AS-00 D1238B48B8AP-00

CPC1972 AC Power Switch

AND8056/D. Control Solution using Logic, Analog Switches, and Discrete Semiconductor Devices for Reversing a One-Phase Motor APPLICATION NOTE

Type PD, Leak-Free Motor Run and Power Supply Capacitors

HPVFP High Performance Full Function Vector Frequency Inverter

INSTRUCTION MANUAL SERIES TRANSMITTER

MASTERFLEX L/S ECONOMY 200 RPM DRIVE 115 VOLT MASTERFLEX L/S ECONOMY 200 RPM DRIVE 230 VOLT

DISCUSSION OF FUNDAMENTALS

Product Data Sheet 8452/2HHP. The engineer's choice

T6+ Analog I/O Section. Installation booklet for part numbers: 5/4-80A-115 5/4-90A-115 5/4-80A /4-90A-1224

Product Data Sheet 3252J/2H3PU

MAHARASHTRA STATE BOARD OF TECHNICAL EDUCATION

Ambient Conditions Storage Conditions Installation Minimum Clearances and Air Flow...2 3

Model Number Structure

GE Ventilated Dry-Type Transformers. Secondary Substation Transformers - 5 and 15kV Class

Speed Control Of Transformer Cooler Control By Using PWM

1. Institute of Electrical and Electronic Engineers (IEEE) a. Standard , IEEE Guide for Harmonic Content and Control.

Classification Contact form Enclosure rating Terminal shapes Model Minimum packing unit Standard. SPST-NO (1a) Fully sealed PCB terminal

L E C T U R E R, E L E C T R I C A L A N D M I C R O E L E C T R O N I C E N G I N E E R I N G

SLU SERIES Universal Phase Monitor/Relay SLU-100-ASA and SLU-100-ASD

BE1-81O/U DIGITAL FREQUENCY RELAY FEATURES

NEO TELE-TRONIX PVT. LTD. 6/7 Bijoygarh, Kolkata , Tel : ; Fax :

ATV212HU22M3X variable speed drive ATV kW - 3hp - 240V - 3ph - wo EMC - IP21

Transcription:

SINPAC Switches: Brief Operating Description For over 75 years, single-phase motors have utilized a mechanical centrifugal switch to switch the start circuit. Inherent characteristics of a mechanical device have made these switches prone to various problems, including tolerances, tolerance buildups, mechanical fatigue, vibration and a host of others that can lead to switch failures and/or performance inconsistency. Our challenge was to design a reliable solid-state switch to replace the mechanical switch and actuator mechanism, and duplicate the function of connecting and disconnecting the start circuit at particular speeds with the additional benefits of a solid-state device. After considerable research, we decided a successful electronic motor starting switch could be created by sensing the voltages present in the main and start windings. Until the rotor of a single-phase motor begins to rotate, there is no coupling between its start winding and main winding. When the rotor begins to turn, the main winding induces flux in the rotor, which then induces a voltage in the start winding. The voltage induced in the start winding is directly proportional to motor speed. Mounting Options In Stearns SINPAC Electronic Switches, the voltage across a motor s main winding and the voltage across its start winding are sampled and fed to a comparator. The logic circuitry is designed so that the electronic switch interrupts the start circuit current after the motor has accelerated to the speed at which cut out voltage is developed, generally 75 to 0% of synchronous motor speed. The logic circuitry then shuts down the switch s power stage, which consists of a triac or inverse parallel SCR s. This function is referred to as cut out. When the start circuit is disconnected, the main winding field then drives the motor s rotor to its running speed. If the motor encounters an overload, and the motor speed falls to approximately 50% of its synchronous speed, the SINPAC Switch automatically reconnects the motor s start circuit. This function is referred to as cut in. Cut in detection circuitry constantly monitors start winding voltage. When the motor s speed falls to the cut in point, the detection circuit causes the control logic to energize the SINPAC Switch s power output stage. The motor then goes through its normal startup procedure, with the start circuit being switched out at a motor speed approximately 75 to 0% of synchronous speed. SINPAC Switches are potted and completely sealed, making it impervious to dust, dirt and moisture. The unique speed sensing circuit provides a universal design which allows a few switches to work on most standard motor designs regardless of manufacturer. Acceptance by Motor Manufacturers US and foreign motor manufacturers have tested and retested the SINPAC Switch for reliability and quality. Today, many of these manufacturers have begun installing SINPAC Switches on their standard motor lines with more companies ready to make the changeover. UL Recognition Most SINPAC Switches have already been recognized under the Component Program of Underwriters Laboratories, Inc. (E-71). In addition, all switches have internal surge protection which is tested according to ANSI/IEEE C621 1991 Category A3. CSA Certification LR-64.

Sinpac Design Features 1 3 2 6 7 5 4 Typical Applications Stearns SINPAC Switches are ideal for applications requiring reliable switching of the start circuit in singlephase motors. Mechanical switches are prone to various problems including mechanical fatigue, tolerances, tolerance build-ups and vibration which can lead to performance inconsistency. Electronic SINPAC Switches solve all those problems which reduce production downtime in hundreds of applications. Some of these applications are illustrated below: 1 Electrically Protected. Designed to filter out electrical noise, so there is no concern of random switch malfunction. 2 Reduced Installation Time. Easy accessible 1/4 inch terminals and mounting, reduce the amount of time required to install SINPAC Switches or to change out mechanical switches. 3 Restart Capability. When motor speed drops below 50% of synchronous speed, the start winding is brought back into the circuit to reinitiate starting torque. 4 Soldered Heat Sink. High cycling. 5 Transient Protection. Transient protection tested per ANSI/IEEE C621-1991 Category A3. 6 Universal Design. 50/60 Hz operation. Will work on 2, 4 or 6 pole motors of any manufacturer. Reduced inventory. 7 Compensation. No modifications or changes are required for line voltage variations. SINPAC Switches will operate in areas susceptible to brown-outs or low voltage due to long wiring runs. ADDITIONAL FEATURES Operating Temperature: -40 C to 65 C (-40 F to 149 F) [for operation between 65 C and 5 C (149 F and 15 F), consult factory.] Operating Voltage: Vac SINPAC Switch: - Vac. For dual voltage motor equipped with center-tapped main winding: - Vac or -265 Vac. 2 Vac SINPAC Switch: 1-5 Vac. Some additional applications include: Grain Dryers 50/60 Hz Water Equipment Paint Sprayers Power Tools Pressure Sprayers Commercial Dryers Vibrators Commercial Washing Machines Auger Drives Ice Makers Door Openers Gas Pumps Sump Pumps Floor Washers Diaphragm Pumps Bottle Washing Machines Hermetic Motors Floor Sanders Rotary Compressors Poultry Feeding Systems Refrigeration Compressors Fans, Blowers Grinding Machines Heat Pumps Milking Machines Jet Pumps Winches Food Processing Gate lifts Hoists Air compressors Door and partition systems Swimming pool pump motors Submersible pumps Vacuum pumps 1

SINPAC Switches: Selection Motor hp ratings are typical. For an accurate selection procedure, measure start winding current during a normal start or at locked rotor and select a SINPAC Switch with higher maximum current rating than that measured. 1. Be sure switch series matches motor type. 2. Be sure switch voltage rating matches (start) circuit voltage rating. 3. Selection can be based on actual measurement of start winding current ortwo times the motor nameplate FLA rating. 4. Switch current rating must match or exceed the motor start winding current requirements. Always select a SINPAC Switch with the next higher current rating for: a) High cycling applications. b) Long acceleration time. c) High ambients: Greater than 55 C. 5. To assure proper motor operation, the voltage across the start winding must reach the SINPAC Switch cut in reference voltage between 70% to 5% of motors synchronous speed. Caution: SINPAC Switches are line voltage compensated. Changes in the line voltage will not effect system operation unless an overload condition causes reduced running speed, along with reduced voltage across the start winding. 6. Higher current switches can be used in place of lower rated switches of the same series. SINPAC Electronic Switch Catalog Numbering System CV 5 Start Winding Voltage (Cut In PV) blank =, 2 = 2 Maximum Current Rating Series = Capacitor Start and Capacitor Start/Capacitor Run Motors, PV = Split Phase Only, CV - Capacitor Start Only, VR = Capacitor Start/Capacitor Run Only, = Capacitor Start Instant Reverse 2 Electronics 7 = SINPAC Switch 1 = PV Series - Split Phase Only 2 = CV Series - Capacitor Start Only 3 = Made-To-Order (MTO)* 4 = Series - Capacitor Start and Capacitor Start/Capacitor Run 5 = Series - Capacitor Start Only 6 = Timer - Fixed Timer Split Phase or Capacitor Start 7 = VR Series - Capacitor Start/ Capacitor Run Only 1 = Start Circuit Voltage 2 = 2 Start Circuit Voltage 0 = Standard A = Inductor Amps (max. current),, 35, 40, 50, 70, or 0 *NOTE: For part numbers beginning with 473 (these are OEM specials), the remaining digits of this numbering system do not apply. 472U01 1 = Standard, 2 = Standard, K = Kit V SINPAC Switch A = VCO, B = VCO, 0 = 5 VCO 0 = 400 ms Timing Interval, V Cut In D = VCO F = 400 ms Timing Interval, V Cut In J = 155 VCO Hybrid 6B K = 5 VCO Hybrid 6 L = VCO 15 VCI P = 00 ms Timing Interval, V Cut In R = VCO T = 600 ms Timing Interval, V Cut In V = 2 VCO W = 0 ms Timing Interval, V Cut In Y = 0 ms Timing Interval, V Cut In 2 V SINPAC Switch C = 260 VCO, 0 = 3 VCO, E = 4 VCO H = 400 ms Timing Interval, 60 V Cut In M = 340 VCO, S = 350 VCO T = 600 ms Timing Interval, 60 V Cut In U = UL Recognized, N = Not UL Package Style = Metal Can 2 x 1.3 x.1 = Metal Can 2.67 x 1.7 x.6 15 = Capacitor Case 1.22 dia. x 3.372 long = Metal Can 2.75 x 2.0 x 1.5 17 = Capacitor Case 2.572 dia. x 4.372 long 19 = Capacitor Case dia. x 3.372 long = Capacitor Case dia. x 2.760 long 21 = Board Only

SINPAC Switches: Compensation Charts PV Series Induced voltage across the start winding is directly proportional to motor speed and line voltage. All SINPAC Switches use this voltage to switch the start winding out of the circuit. Your motor with a SINPAC Switch must generate a voltage that is % greater than the switch cut in voltage to assure cut out of the start winding. Refer to the chart below. 1 PV 0 40 50 60 60 CV, VR,, and Series Induced voltage across the start winding is directly proportional to motor speed and line voltage. All SINPAC Switches use this voltage to switch the start capacitor out of the circuit. Your motor with a SINPAC Switch must generate a voltage that is % greater than the switch cut out voltage to assure cut out of the start capacitor. Refer to charts below. CV and VR 1 5 CV and VR 1 140 150 0 170 1, 5 CV and VR 35 40 45 50 55 1 5 1 140 150 0 170 1 5 35 40 45 50 55 260 260 2CV, 2VR, and 2 240 2 260V 3V 240 2 260V, 3V 0 2CV, 2VR, 2 0 0 400 500 Start (Auxiliary) Winding Volts 0 2CV, 2VR, 2 60 70 0 Start (Auxiliary) Winding Volts SERIES 1 5 1 5 1 140 150 0 170 35 40 45 50 55 3

PV and 2PV Series for Vac, 2 Vac or /2 Vac Dual Voltage Split Phase Motors Basic Operation The PV Series SINPAC uses a pulse sampling technique to monitor RPM-sensitive information (induced voltage) across the motor start winding. After the initial timing period, solid-state logic will sample the induced voltage across the start winding and will repeat this sequence until the voltage across the start winding is above the cut-in reference value. The SINPAC logic circuit continues to monitor the RPMsensitive information (induced voltage) on the start winding. If the SINPAC logic detects that the motor RPM drops below a certain point, it automatically recloses the solid-state switch reconnecting the start winding. Both the initial timing period and cut-in reference value can be modified to meet specific applications. Typical Maximum Motor hp Typical Full Load Motor Nameplate Current Rating (amps) Volts /2 Volts /4 /4 /4 /4 Switch Rating and Permissible Maximum Start Winding Current (amps) Start Circuit Voltage 2 Catalog Number PV-- PV-- 2PV--60 PV-- PV-- Part Number 4-7---UF1 4-7---UF1 4-7---U01 4-7---U01 4-7-6--NH1 4-7---UF1 4-7---UF1 4-7---U01 4-7---U01 Timing Interval* (sec.) Cut In Voltage Typical 60 Package Style 3/4 3/4 / / 40 40 PV-40-4-7-40--U01 4-7-40--U01 *NOTE FOR PV SWITCH APPLICATIONS: Please contact the factory for available other timing intervals or cut in voltages. - Enclosure - Enclosure Wiring Diagram Catalog Number SINPAC Switch Rating Volt 50/60 Hz Motor Operation 2 Volt 50/60 Hz Motor Operation Dimensions are for estimating only. Drawings for customer reference are available upon request. PV- PV- PV-40 Gasket for - Enclosure Connect to Split Phase Motors 2PV- Connect to Split Phase Motors Not Applicable 4 M Motor main winding, ST Motor start winding