UB 001 relay - 1 level load shedding

Similar documents
UB 200 relay - Voltage monitoring

UBC 200 relay - Voltage monitoring

UTC relay - Voltage monitoring & off delay

TELAU 400 relay - Delay-on pull-in or

407 relay - Latching, safety critical, 40 contacts Datasheet

TTBCR 200 relay - Delay-on drop-out,

BM 400 relay - Mixed load, 4 contacts

AG 400 relay - Gold plated, 4 contacts

TBSBAO 400 relay - Delay-on pull-in,

MSV200 - Hall effect transducer

MSA Hall effect transducer

MSA500 - Hall effect transducer

RC-19A relay - Current monitoring

V88 socket - Spring clamp terminal,

KCS-U200 relay - Latching, 2 pole

C relay - Safety critical, 9 contacts

CK relay - safety critical, 9 contacts

BD relay - Industrial latching power

CM relay - 7 contacts + 2 gold contacts

MTDV4-U200 relay - Voltage monitoring,

TDB4-U200 relay - Timer, delay-on, 4 pole

D4-U200 relay module - 4-pole

MTDV4 relay - Voltage monitoring,

Mors Smitt Industrial Technology. High performance plug-in relays

D-U200 Instantaneous relay Part of D-platform

D-B Power relay, high DC breaking capacity Part of D-platform

D Instantaneous relay Part of D-platform

Manual Signal calibration box (SCB)

Mors Smitt Industrial Technology. Industrial current & voltage sensors. Hall effect current & voltage sensors

Mors Smitt Industrial Technology

Mors Smitt Industrial Technology

Portable relay tester PRT-MS1 User manual

Mors Smitt Group - Serving Safety

Mors Smitt Railway Technology. Railway relays

PRODUCT DESCRIPTION PAG ES. E110 Series 1PDT, 10 AMP RELAY 2-6. E310 Series 3PDT, 10 AMP RELAY E210 / E215 Series 2PDT, 10/15 AMP RELAY 13-19

Ordering Information. Latching Relay MMK. Available Models. Models Conforming to Auxiliary Power Relay Specifications

OKT OKR Series APPLICATIONS. Shipbuilding

Contactors. Series C137, C163, C164, C165 Single pole contactors for battery voltages Catalogue B60.en

C20.en. Power contactors for AC and DC CT1115 and CT1130. Connect - Contact - Control

Polarized, latching hermetically sealed relay Contact arrangement. 3 PDT Coil supply

INSTRUCTION MANUAL (ATEX / IECEx)

SERIES KC RELAY NONLATCH 3PDT, 25 AMP

C20.en. Power contactors for AC and DC CT1115 and CT1130. Connect - Contact - Control

MI-10kV. Technical specifications Operating instructions. Supplier:

1 POLE - 1 to 2A (For Signal Switching)

Electrical Specifications

OMRON MK-I / -S RELAY

Connect - Contact - Control. DC Contactors 600V / 750V / 1000V. F 215e

Relays & Sockets RU Series Universal Relays. With Latching or Momentary Lever. Standard (without lever) Key features:

DPDT MY2N-D2 MY2IN-D2 --- (DC only) 4PDT MY4N-D2 MY4IN-D PDT (bifurcated) MY4ZN-D2 MY4ZIN-D2 --- With built-in CR

2 Pole CO, 8 A Plug-in 2 CO (DPDT) 1 CO (SPDT) 8/15 16/25* 250/ /400 2,000 4, /0.5/ /0.5/ (5/5) 300 (10/5)

Nieaf-Smitt Maritime. Analogue panel indicators

Ratchet Relay. Ordering Information. Unique Ratchet Mechanism Assures Positive Alternate Transfer/Switching Operation. G4Q-jjjj

General-purpose Relay

Model UT20B: OPERATING MANUAL Table of Contents (1)

DPDT+DPST-NO MM4KP-JD MM4XKP-JD

Ordering Information. Ratchet Relay G4Q. Model Number Legend

Type Contact form Plug-in/solder Plug-in/solder PCB terminals Upper-mounting terminals terminals with plug-in/solder

Electrical Specifications

Model Number Structure

3.4. Control Relays and Timers. Contents Description D5RR/D5RF Series... D7PR/D7PF Series. General Purpose Plug-In Relays

Electrical Specifications

RETROFITTING. Motor Protection Relay. Two mountings are available, Flush Rear Connection (EDPAR) or Projecting Rear Connection (SDPAR).

Introducing. CII FCA-150 Series Relay 50 Amps, 1PST/NO (DM) CII FCAC-150 Series Relay 50 Amps, 1PST/NO (DM) with 1PDT Auxiliary Contacts

Two-way Action Test Button (Models with Lockable Test Button) For Momentary Operation

YL SERIES RELAY LATCH DC COIL 4PDT, LOW LEVEL TO 5 AMP

All-or-nothing relay RH(M) 1000 in plug-in case and case for top-hat rail or wall mounting

AUXILIARY RELAYS FOR TRIPPING APPLICATIONS

AC / DC STROOMTANG MULTIMETER NI 30 AC / DC CLAMP MULTIMETER NI 30. Handleiding / Manual

PCB relay for DC voltage, polarized, monostable or bistable

MK-S (New Models) General-purpose Relays. New Super MK Relays. Models with Latching Lever Added to the Series. Features. Model Number Structure

General-purpose Relay

62 Series - Power relays 16 A. Features SERIES / / Printed circuit mount 16 A Power relay

SYNCHRONISM RELAY SYNCRO-96. (Code ) INSTRUCTION MANUAL ( M / 99A ) (c) CIRCUTOR S.A.

62.22 Copper side view

2 or 4 pole changeover contact Plug-in/Faston 187

HG RELAYS 20 AMP POWER RELAY FEATURES SPECIFICATIONS

MK-S (New Models) General-purpose Relays. New Super MK Relays. Models with Latching Lever Added to the Series. Features. Model Number Structure

G7K. Latching Relay. Compact Mechanical Lock Latching Relays with Manual Buttons. Model Number Structure. Ordering Information

COMPACT HIGH POWER RELAY

HMI Components. Series. Flush design Raised design PCB (with adaptor) Indicator Pushbutton Illuminated pushbutton

IGS IGS-M-EL-22(1) Contactors APPROVED. Iranian Gas Standards

CROMPTON INSTRUMENTS INTEGRA 1222 DIGITAL METERING SYSTEM

Standard model G2A-432A-US G2A-4321P-US. Arc barrier equipped model G2A-432AY-US ---

Relays & Sockets RY/RM RY/RM Series Miniature Relays. Part Number Selection

Table of Contents. Kilovac Time Delay Relays

Model UT10A: OPERATING MANUAL Table of Contents (1)

Instantaneous Overcurrent Relay

62 Series - Power relays 16 A. Features / /

Phase-sequence Phase-loss Relay

Item ref: UK MTM01 DIGITAL MULTITESTER. User Manual

Ordering Information. Power Relay G2A. Model Number Legend Highly Reliable, 4-pole Miniature Relay Ideal for Sequence Control

Proximity Sensor Terminology

SINEAX TV809, 1 channel Programmable Isolating Amplifier

POWER. NLP40 Series. Single, Dual and Triple Output. Data Sheet

PROXIMITY SENSOR TERMINOLOGY

HIGH VOLTAGE AND CURRENT CUT-OFF CAPACITY IN A COMPACT PACKAGE

HIGH VOLTAGE AND CURRENT CUT-OFF CAPACITY IN A COMPACT PACKAGE

HMI Components. Series. Raised design PCB (with adaptor) Machinery and Automation. Indicator Illuminated pushbutton

CX-Series. Circuit Breaker

Transcription:

- 1 level load shedding Datasheet Features Load shedding relay 1 voltage level 1 N/O solid state contact Plug-in design with secure locking feature for maximum ease of maintenance -40 C...+85 C operating temperature Benefits Description The voltage monitoring relay UB 001 opens auxiliary loads circuits when battery voltage becomes too low and puts them back in service when battery voltage recovers. A time delay of 20 seconds engages before opening a load circuit and a time delay of 2 seconds before putting back in service a load. The plug-in design offers secure locking feature for maximum ease of maintenance (no wires need to be disconnected or other hardware removed for relay inspection or replacement). The resistance to impact and vibration is conform to standards in force for Railway Transported Equipment. Positive mechanical keying of relay to socket is built into relay and socket during manufacture and terminal identifications are clearly marked on identification plate that is permanently attached to the relay. The UB 001 relay is pluggable in the following sockets: EA 102 B, EA 102 BF, EA 103 BF, EA 104 B, EA 104 BF, EA 105 BF, EA 112 BF. Proven reliable Long life cycle Easy to maintain and replace Low life cycle cost No maintenance Railway compliancy NF F 62-002 Rolling stock - Instantaneous relays contacts and sockets NF F 16-101/102 Fire behaviour - Railway rolling stock EN 50155 Railway application - Electronic equipment used on rolling stock IEC 61373 Railway application - shock and vibration tests Application The UB 001 relay is designed for voltage level sensing and used for example to monitor the battery load shedding. 1

Technical specifications Functional and connection diagrams Timing diagram Relay pin correspondence Level 1 Voltage drop Voltage increase Level 1 Relay pin correspondence 1 2 3 4 a R S K L a P T J M b O N H G b c d C B D A E F W V X U Y Z c d t1 t2 1 2 3 4 (rear view of relay shown) Example: DV keying Connection diagram Level 1 D2 +V D1 D4 +V Power supply -V 2

Technical specifications Input data Keying Unom (VDC) Uoperating (VDC) Level 1 (drop/increase) VDC TBD (1) 24 15 / 30 23 / 25 TBD (1) 36 25 / 48 TBD (1) TBD (1) 48 30 / 64 TBD (1) TBD (1) 72 46 / 96 65 / 70 TBD (1) 110 70 / 140 87 / 95 (1) to be defined Electrical characteristics Operating voltage 24 VDC...110 VDC Operating current < 10 ma Output configuration 1 N/O solid state contact Maximum load current 0.25 A Contact life 72 VDC, 0.25 A, L/R = 0 ma 10 6 operations 72 VDC, 0.25 A, L/R = 30 ms 10 6 operations Dielectric strength 1500 VAC, 1 min Time delay characteristics Time delay on voltage increase Time delay on volage drop 0...20 s (t1) to be defined 0...20 s (t2) to be defined Accuracy repeatability Voltage level tolerance + 1 V 3

Technical specifications Mechanical and environmental specifications Operating temperature -40 o C...+85 o C, IP50 (relay on socket) Vibrations 3 axis 2 g / 10...150 Hz Shocks 30 g / 11 ms Operating position Any attitude Environment NF F 20-600 Weight 150 g Material Polycarbonat (cover) / Polyester Melamine (base) Fire and smoke NF F 16-101/102 4

Technical specifications Dimensions (mm) Used with locking brackets Used with wire locking spring 5

Mounting possiblities / sockets EA 102 B EA 103 BF EA 104 B EA 112 BF Panel/flush mounting EA 102 B EA 102 BF EA 104 B EA 104 BF EA 112 BF Locking bracket (905843), rear connection, double Faston 5 mm Wire locking spring (926853), rear connection, single Faston 5 mm Locking bracket (905843), rear connection, single Faston 5 x 0.8 mm Wire locking spring (926853), rear connection, single Faston 5 x 0.8mm Wire locking spring (926853), rear connection, crimp contact Surface/wall mounting EA 103 BF* EA 105 BF* Wire locking spring (926853), front connection, M3 screw 6.5 mm ring terminals (2,5 mm 2 ) Wire locking spring (926853), front connection, single Faston 5 mm * Mounting possibility on 35 mm rail EN 50022 by adding suffix D to the part number (see socket datasheet) Note: Keying of relay to socket can be specified by adding the keying letters in the part number. See all details in the related socket datasheet. 6

Spare parts Spare parts - order part numbers (1) (1) (1) (1) LOCKING BRACKET 905846 (1) (1) SCREW FOR BRACKET METAL STRAP (2) METAL STRAP (4) C927210 P928060 (2) (3) P928061 WIRE LOCKING SPRING 431906654 ROUND PLASTIC PLUGS 414928005 HEX. PLASTIC KEYS 414905678 LOCK PINS ASSY 2 SCREWS 906364 212903020 (1) Parts only for socket (2) Parts for relay and socket (3) Parts only for relay 7

Instructions Installation Install socket and connect wiring correctly according identification to terminals. Plug relay into socket. Reverse installation into socket not possible due to mechanical blocking by snap-lock. Don t reverse polarity of coil connection. Relays can be mounted (tightly) next to each other and in any attitude. Warning! Never use silicon near by relays Operation Before operating always apply voltage to coil to check correct operation. Long term storage may corrode the silver on the relay pins. Just by plugging the relay into the socket, the female bifurcated receivers will automatically clean the corrosion on the pins and guarantee a good connection. Do not use the relay in places with flammable gas as the arc generated from switching could ignite gasses. Maintenance Correct operation of relay can easily be checked as transparent cover gives good visibility on the moving contacts. When the relay doesn t seem to operate correct, please check presence of coil voltage. Use a multimeter. If LED is used, coil presence should be indicated. If coil voltage is present, but the relay doesn t work, a short circuit of suppression diode is possible (The coil connection was reversed). If relay doesn t work after inspection, please replace relay unit by a similar model. Send defective relay back to manufacturer. Normal wear and tear excluded. 8

Ordering scheme Configuration: UB 001 72 XX F 1 1. Relay model 2. No. of 3. Nominal 4. Keying 5. Cover 6. Language contacts voltage type (test report) This example represents a UB 001 72 XX F 1. Description: UB 001 relay, Unom: 72 VDC, keying XX, relay cover for wire locking spring, test report in English 1. Relay model UB 2. Number of contacts 001 1 contact (level) 3 & 4. Nominal voltage and keying 24 XX 24 VDC 36 XX 36 VDC 48 XX 48 VDC 72 XX 72 VDC 110 XX 110 VDC XX = to be defined 5. Relay cover type Relay cover with lock pins F Relay cover for wire locking spring 6. Language on test report French 1 English 2 Spanish 9

DS-UB 001-V2.0 May 2013 Mors Smitt France SAS Tour Rosny 2, Avenue du Général de Gaulle, F - 93118 Rosny-sous-Bois Cedex, FRANCE T +33 (0)1 4812 1440, F +33 (0)1 4855 9001 E sales@msrelais.com Mors Smitt Asia Ltd. # 807, Billion Trade Centre, 31 Hung To Road Kwun Tong, Kowloon, HONG KONG SAR T +852 2343 5555, F +852 2343 6555 E info@morssmitt.hk Mors Smitt B.V. Vrieslantlaan 6, 3526 AA Utrecht, NETHERLANDS T +31 (0)30 288 1311, F +31 (0)30 289 8816 E sales@nieaf-smitt.nl Mors Smitt Technologies Inc. 420 Sackett Point Road North Haven, CT 06473, USA T +1 (203) 287 8858, F +1 (888) 287 8852 E mstechnologies@msrelais.com Mors Smitt UK Ltd. Doulton Road, Cradley Heath West Midlands, B64 5QB, UK T +44 (0)1384 567 755, F +44 (0)1384 567 710 E info@morssmitt.co.uk (c) Copyright 2013 All rights reserved. Nothing from this edition may be multiplied, or made public in any form or manner, either electronically, mechanically, by photocopying, recording, or in any manner, without prior written consent from Mors Smitt. This also applies to accompanying drawings and diagrams. Due to a policy of continuous development Mors Smitt reserves the right to alter the equipment specification and description outlined in this datasheet without prior notice and no part of this publication shall be deemed to be part of any contract for the equipment unless specifically referred to as an inclusion within such contract.