Instruction manual TAG 2550-C Tester + Analyser and software: PT9 Report Creator Manual for initiation and maintenance No.

Similar documents
UNCONTROLLED WHEN PRINTED

This manual should be read in its entirety prior to operation of the TS200 Test Set Page 2 of 9

SUNNY BEAM REPEATER Transmission Range Increase for Sunny Beam

DIGITAL DUAL DISPLAY AC/DC CLAMP METER MODEL-860A OPERATION MANUAL

Photometer Maintenance Guide

User Manual. High Efficiency Locator Beacon

Operating Instructions PROFITEST H+E TECH. Diagnostics Unit for Electric Charging Stations (Type 2 Connector Socket and Plug) /3.

User s Manual. Ground Resistance Clamp On Tester MODEL

SPM-50 RF Spectrum Power Meter PC Software User Manual

200Amp AC Clamp Meter + NCV Model MA250

M2M i-link POINT-TO-MULTIPOINT INSTALLATION INSTRUCTIONS

Digital Function Generator

Heiland electronic GmbH TD / TD1 / TD2. B&W-Densitometers. USERS MANUAL Version 5

PC Gamepad OPERATION MANUAL GC

Read and be familiar with this manual before operating or servicing this device. To ensure operator, technician, and patient safety, use only as

MS2109A AC/DC Clamp Meter. User Manual. Contents

SL300 Snow Depth Sensor USL300 SNOW DEPTH SENSOR. Revision User Manual

Wilcom MODEL T136BSBZW CIRCUIT TEST SET. Operating Instructions

True RMS AC / DC Power Clamp Meter Model

Wilcom MODEL T136BGMZW CIRCUIT TEST SET. Operating Instructions

User Guide. Digital AC/DC Clamp Meter Model 38394

Dawson DDM190. Digital Multimeter User s Manual

User s Guide. Digital AC/DC Clamp Meter Model 38394

CM605. User Manual AC/DC LOW CURRENT CLAMP-ON METER ENGLISH

Multifunction AC/DC Voltage Tester

MANUAL. Electrostatic Field Meter EFM 235 / 255. System Prof. Dr.-Ing. Hans Kleinwächter

OVA-50 Optical Variable Attenuator User s Manual

HAWK5000 Operators Manual

Beaming Optical Length Tester (BOLT)

WRIST GAMMA INDICATOR РМ1208M OPERATING MANUAL

UR200SI / UR200WE ENGLISH

Detectores de metales y otros materiales digitales GMS120 bosch manual ingles

Issue No: MG025 Date: 05 June McMurdo SmartFind R5 GMDSS Radio IMO MSC. 1/Circ Update procedure

User Guide. AC/DC Mini Clamp Meter. Model Introduction. Large 3 3/4 digit LCD display with 40 segment bargraph

User s Guide. 400A AC/DC Clamp Meter. Model MA220

Heiland electronic GmbH TRD 2. B&W-Densitometer. User manual Version 6.4

High power radio transmission module MR03 type

Radio Control Installation and Operating Instructions System 4

User's Guide. 800 Amp AC/DC True RMS Clamp Meter. Model EX Washington Street Melrose, MA Phone Toll Free

Accessories Solar Datatechnology Wireless-Set485-01/-Set485-02

Dawson DDM181. Pocket-Size Autorange Digital Meter User s Manual

ACA LEAKAGE TESTER OPERATION MANUAL. auto range, true rms. Model : DL-9954

TESTRANSFO2 User s Guide

User s Guide. Model MA A AC Mini Clamp-on Meter

User s Manual. MiniTec TM Series. Model MN26 (Model MN26T includes temperature probe) Mini Autoranging MultiMeter

TRMS LEAKAGE CURRENT CLAMP-ON METER 565

Instruction also available on

BeeLine TX User s Guide V1.1c 4/25/2005

CD770 DIGITAL MULTIMETER INSTRUCTION MANUAL

INSTRUCTION MANUAL. IBRit - rf1 - usb PC - Station for wireless Data transmission. M e s s t e c h n i k. Messtechnik GmbH & Co.

Manual Hand-held Gaussmeter BGM101

AAA Balanced / Unbalanced Line Audio Interface Amplifiers. User Manual. I.R.T. Communications Pty Ltd

MICROSCANNER TM D-Series

TECHNICAL MANUAL ULTRASONIC TEST SET MODEL 42A12D JUNE 15, 1998 REV 00 SEACOM DIVISION

CL900. True RMS 1000V 2000A 60MΩ ENGLISH. INSTRUCTION MANUAL 2000A Digital Clamp Meter. Measurement Technology

Opus 21 s80 Integrated Amplifier Owner's Manual

MD9300 Metal Detector OWNER S MANUAL

G7K. Latching Relay. Compact Mechanical Lock Latching Relays with Manual Buttons. Model Number Structure. Ordering Information

Operating Instructions CAMILLE BAUER METRAWATT METRAOHM /9.97. Low impedance resistance meas. instrument

GAMMA 12 DIGITAL MULTIMETER

UT232. Operating Manual. Digital Power Clamp Meter

Model UT233 OPERATING MANUAL

7006 Loop Mate 1 Loop / Voltage / Current Simulator

Pipe Laser Model No Instruction Manual

HZJF-9007 Fully Functional Partial Discharge Inspector USER MANUAL. Huazheng Electric Manufacturing(Baoding) Co.,Ltd

Nuclear Associates

DIGITAL DUAL DISPLAY AC/DC CLAMP METER MODEL- KM 2782 / 2782-T

DCM730. Digital Clamp Meter User s Manual

DDM350 Pen-Type Digital Multimeter User s Manual

TR Digital Earth Resistance Tester

PyroMiniUSB Series Operators Guide

Junction Box JB6101- (000) Installation and Operation. Manual DV Issue 1 June 2012

GAMMA 10 DIGITAL MULTIMETER

D10 Demonstration Board

Radio System Strobe Wizard Plus Freemask

Analog Signal DIN Fiber Link System

INSTRUCTION MANUAL UTL260

Not for Reproduction

Model UT511 OPERATING MANUAL

Instruction Manual TS

léìë=on ëpm=fåíéöê~íéç=^ãéäáñáéê lïåéêdë=j~åì~ä êéëçäìíáçå

MS8250A/B OPERATION MANUAL MS8250A. Hz% FUNC REL RANGE REL HOLD OFF 10A. Hz% A NCV. Hz% COM. A ma 10A FUSED 600V CAT IV.

400Amp True RMS AC Clamp Meter + NCV

Hand Crimp Tool Operating Instruction Sheet and Specifications Part No Eng. No. RHT 2749-CC (Replaces )

All Purpose Hardware

Safety Information (Attach ed at the upper cover of t his product) Safety Warning (Attached on the output fiber isolato r & collimator) Figure 1 Laser

OPTITEMP TT 20 Technical Datasheet

FMX 003. Gebruikershandleiding NL Pagina 3. Bedienungsanleitung D Seite 12. User s Manual UK Page 21. Notice d uilisation F Page 30

Professional UHF Rechargeable Wireless Microphone System POWER ON/OFF BATTERY CHARGE. Green Light (Full) Better Music Builder DOWN VOLUME

UVA/B Light Meter. Instruction Manual. UVA/B Light Meter Copyright 2009 by Sper Scientific ALL RIGHTS RESERVED. Printed in the USA

Excellent Integrated System Limited

EM420A/420B DIGITAL MULTIMETER OWNERS MANUAL Read this owners manual thoroughly before use

TABLE OF CONTENTS WARRANTY

Bedienungsanleitung Instruction Manual. testo 815 Sound Level Meter

Model: &

ProfiScale MULTI Multimeter

Item ref: UK MTTR01 TRUE RMS DIGITAL MULTITESTER WITH USB INTERFACE. User Manual

User Manual. All rights reserved. Specifications are subject to change without notice.

Precipitation Monitor ,

Model: Pro95 TRUE RMS MILLIAMP CLAMP METER

Transcription:

Instruction manual TAG 2550-C Tester + Analyser and software: PT9 Report Creator Manual for initiation and maintenance No.: 350-18216-A2e Novega Produktionssysteme GmbH Gewerbepark 2 87477 Sulzberg (See) Germany Fon: (+49) 8376-92990-0 Fax: (+49) 8376-92990-20 E-Mail: service@novega.de www.novega-sea.com

THIS MANUAL IS TO BE READ TO ITS FULL EXTENT PRELIMINARY TO ANY INITIATION OR OPERATION, ANY TESTING OR MAINTENANCE OF THE TAG 2550-C. Annotation of the number of this manual: 350 18216 A2e Revision key- exemplar- document- language number sequence number Annotation of the part- and serial number system of TAG 2550-C: 350 18216 00 XXXX key- exemplar modification partnumber index sequence number Type plate: Figure 1: Type plate Manual TAG 2550-C 2 of 12

Index 1. Introduction... 4 2. Scope of delivery... 4 3. Symbols and Abbreviations... 4 4. Description TAG 2550-C... 5 4.1. General... 5 4.2. Specification of the TAG 2550-C... 6 5. Test-/ Analyse procedure... 7 5.1 Configuration... 7 5.2 Functional test and readout... 7 5.3 Installation of Data transmission from the TAG 2550-C... 8 5.4 Data transfer... 8 5.5 Software PT9 Report Creator... 9 6. Maintenance... 10 6.1. General... 10 6.2. Battery replacement... 10 6.3. Battery disposal... 10 6.4.Cleaning of TAG 2550-C... 10 7. Warranty... 11 8. Reshipment... 11 8.1. TAG 2550-C return - defective... 11 8.2. TAG 2550-C return -no defect... 11 8.3. Return TAG2550-C out of warranty... 11 8.4. Annual functional test... 11 8.5. Battery replacment... 11 8.6. Packaging oft he return... 12 8.7. Documents to attach... 12 8.8. Return Authorisation Number... 12 Manual TAG 2550-C 3 of 12

1. Introduction This manual consists in the description as well as the operation - and maintenance directive of the TAG 2550 testing kit. 2. Scope of delivery CD Tester + Analyser (350-18216) Earphone (350-17930) Activation clamp (350-18308) Connection lead (350-18622) Figure 2: Scope of delivery 3. Symbols and Abbreviations PT9 Acoustic Beacon for VDR / S-VDR ULD Underwater Locating Device C Grad Celsius mm Millimeter s Second khz Kilo Hertz LED Light emitting Diode PC Personal Computer TAG Testing and analysing Unit CD compact disc Manual TAG 2550-C 4 of 12

4. Description TAG 2550-C 4.1. General The TAG 2550-C is a battery powered receiver for ultrasonic signals with a frequency of 25 to 50 khz. Protocol files of von PT9 ULD s can be read out and analised. The TAG receives ultrasonic signals via the integrated microphone. The received signals are played back optically via a yellow LED and acoustically by dint of an integrated loudspeaker, same as by an earphone. Parallel on this, data can be read out from the PT9. For data protection, the readout data can be transmitted to a PC by a connection lead. The TAG 2550-C is a sensible instrument which is to be protected from humidity and crushes! Advice: The TAG 2550-C cuts off automatically 5 minutes after the last operation, but the data of the lastly read out PT9 remain recorded on the TAG 2550-C. Control panel: Figure 3: Control panel On / Off Advice: The acoustic signal can be cut off by keeping the data transmission button (4 s) (beep off). On restarting the device or repeatedly keeping the data transmission button this function is reset and the signal is switched on again. (beep on). Data links: LED yellow Data transfer PC Readout off PT9 ULD Activation clamp Earphone USB Figure 4: Data links Microphone Manual TAG 2550-C 5 of 12

Display: Figure 5: Display 1 Advice: The display is updated every 5 sec. The value PT9Bat (voltage average value) is updated with every change. If the power supply of the TAG 2550-C falls below a voltage limit (8V), there is shown a second scale (Low Tester Battery). Display 1 Description Unit Definition Example Figure 5 Serial Number serial number number fixed value 12323 Production date of manufacture the electronics MM/JJJJ month /year fixed value 8/2009 Acoustic Signal receiving an ultrasonic signal ( =no signal; o.k. = signal received) variable o.k. PT9 Bat average voltage (value > 2,5V = ok) volt variable OK 3.2V 4.2. Specification of the TAG 2550-C Receiver frequency Power supply Operating voltage 25 khz to 50 khz Alkali-Battery 9V block PP3 9 Volt Operating temperature range 0 C to + 40 C Size 120mm x 76mm x 28mm (L x B x H) Weight 180 Gramm Manual TAG 2550-C 6 of 12

5. Test-/ Analyse procedure 5.1 Configuration Battery cover (three bore holes) Symbol (three bore holes) Figure 7: Configuration Figure 8: Positioning Figure 7 shows a possible configuration for the functional test and analysis of a PT9 ULD. Please pay attention to the correct position of the PT9 in the activation clamp. The battery cover is situated on the symbol s side, see figure 8. The two test prods of the activation clamp have to abut at the poles of the PT9. Advice: It is not necessary to connect a PC to the TAG 2550-C during the functional test and the analysis of the PT9. The data of the lastly readout PT9 stay recorded on the TAG 2550-C and can be read off or transmitted to a PC later. 5.2 Functional test and readout Switch on the TAG 2550-C by using the der On-/Off-button. Pressing the button readout PT9 causes the activation of the PT9 for 60 sec. The data of the PT9 are read out and the voltage is measured simultaneously. Functional test: Level the microphone of the TAG 2550-C at the PT9 with a distance of ca. 10 cm. The functional test is successful if the TAG 2550-C shows the received signal optically by the yellow LED and acoustically bat he integrated loudspeaker or by the earphone. Advice: On wrong position of the PT9 in the activation clamp, the display shows No Data, the PT9 will be activated for 60 sec though. After duration of 60 seconds please insert the PT9 as shown in fig. 8 and restart the procedure. Manual TAG 2550-C 7 of 12

5.3 Installation of Data transmission from the TAG 2550-C Step 1: Step 2: Step 3: Step 4: Install the software "PT9 Report Creator" from the attached CD. Connect the TAG 2550-C by dint of the connecting cable to the PC. Turn on the TAG 2550-C. Start the program PT9 Report Creator. Select the USB-Port in the program window PT9 Report Creator and then press the button connect (e.g. COM7). Figure 9: Description of the compound Advice: The serial number is programmed only from the production date 01/2013, for all other devices displayed a "0". The serial number must be added in the program window. 5.4 Data transfer The data, stored on the TAG 2550-C pressing the button Data transmission PC. are transmitted to the PC by Advice: If the TAG 2550-C cuts out, the connection is to be cut and restarted. Manual TAG 2550-C 8 of 12

5.5 Software PT9 Report Creator Press the button print (see figure 9) and the report can be printed. All fields of the PT9 Report Creator can be edited. In addition, under "Remarks" notes can be added to the tested ULD. Figure 10: protocol Manual TAG 2550-C 9 of 12

6. Maintenance This item contains instructions for the battery replacement of the TAG 2550-C and its cleaning, same as its storage and disposal. 6.1. General The TAG 2550-C battery replacement should be made in a maintenance room under clean conditions, to avoid impurities by dust, dirt or humidity in the interior of the TAG 2550-C. 6.2. Battery replacement Battery cover Screw Figure 17: Battery replacement For battery replacement, remove the screw and open the battery cover. Remove the used battery and insert a new one. Caution! While replacing the battery, attend to the correct polarity! At closing the TAG 2550-C, the clip has to lock in place under low pressure. The housing can now be screwed. Warning: AN INAPPROPRIATE INSTALLATION OF THE BATTERY MIGHT CAUSE A DAMAGE OF THE TAG 2550-C ELECTRONICS. 6.3. Battery disposal Dispose the battery in accordance with all local, state and federal regulations. Keep away from children. 6.4.Cleaning of TAG 2550-C Clean the TAG 2550-C with a soft, anti- static and dry cloth. Manual TAG 2550-C 10 of 12

7. Warranty The warranty period of the TAG 2550-C constitutes 2 years from the date of delivery by. Novega Produktionssysteme GmbH Gewerbepark 2 87477 Sulzberg (See) Germany Fon: (+49) 8376-92990-0 Fax: (+49) 8376-92990-20 E-Mail: service@novega.de 8. Reshipment 8.1. TAG 2550-C return - defective In case of failure, which is determined to be within the warranty terms, the TAG 2550-C will be repaired or replaced by Novega to the customer. 8.2. TAG 2550-C return -no defect If a TAG 2550-C is returned to Novega and it is found to be functional, the beacon will be returned to the customer, shipping collect. In addition, the customer will be informed, that an analysis fee applies. 8.3. Return TAG2550-C out of warranty If the TAG 2550-C is returned to Novega out of warranty, the customer will receive an estimate of costs. 8.4. Annual functional test The annual functional test is made by Novega. Please ship the TAG 2550-C inclusive original packaging and documentation. 8.5. Battery replacment The TAG 2550-C can be returned to Novega for battery replacement. (e.g. in case of the annual functional test). Please ship the TAG 2550- C inclusive packaging and the original documentation. Manual TAG 2550-C 11 of 12

8.6. Packaging oft he return Ascertain, that there is provided a proper protection packaging for the Underwater Locating Device, i.e. protection against unintentional breakage, scratches or abrasions. 8.7. Documents to attach Reason for return Serial number oft he TAG 2550-C Return Authorisation Number (vide 8.8.) Calibration Certificate 8.8. Return Authorisation Number Prior to shipping the TAG 2550-C to Novega, a Return Authorisation Number should be required at: Novega Produktionssysteme GmbH Gewerbepark 2 87477 Sulzberg (See) Germany Fon: (+49) 8376-92990-0 Fax: (+49) 8376-92990-20 E-Mail: service@novega.de www.novega-sea.com Manual TAG 2550-C 12 of 12