arxiv: v1 [physics.optics] 2 Nov 2012

Similar documents
Color electroholography by three colored reference lights simultaneously incident upon one hologram panel

ELECTRONIC HOLOGRAPHY

Study of self-interference incoherent digital holography for the application of retinal imaging

Three-dimensional quantitative phase measurement by Commonpath Digital Holographic Microscopy

DIGITAL HOLOGRAPHY USING A PHOTOGRAPHIC CAMERA

arxiv: v1 [physics.optics] 10 Jul 2014

Afocal Digital Holographic Microscopy and its Advantages

In-line digital holographic interferometry

Pixel size and pitch measurements of liquid crystal spatial light modulator by optical diffraction

INTRODUCTION TO MODERN DIGITAL HOLOGRAPHY

Parallel Digital Holography Three-Dimensional Image Measurement Technique for Moving Cells

Particles Depth Detection using In-Line Digital Holography Configuration

Confocal Imaging Through Scattering Media with a Volume Holographic Filter

Synthetic aperture single-exposure on-axis digital holography

FRAUNHOFER AND FRESNEL DIFFRACTION IN ONE DIMENSION

Minimized speckle noise in lens-less holographic projection by pixel separation

Be aware that there is no universal notation for the various quantities.

1 Laboratory 7: Fourier Optics

Focus detection in digital holography by cross-sectional images of propagating waves

Following the path of light: recovering and manipulating the information about an object

4-2 Image Storage Techniques using Photorefractive

Spatial information transmission beyond a system s diffraction limit using optical spectral encoding of spatial frequency

Optical sectioning using a digital Fresnel incoherent-holography-based confocal imaging system

Research Trends in Spatial Imaging 3D Video

Design of a digital holographic interferometer for the. ZaP Flow Z-Pinch

Chapter 4: Fourier Optics

Compensation of hologram distortion by controlling defocus component in reference beam wavefront for angle multiplexed holograms

SUPPLEMENTARY INFORMATION

Semiconductor wafer defect detection using digital holography

Speckle-free digital holographic recording of a diffusely reflecting object

Fourier Transformation Hologram Experiment using Liquid Crystal Display. Kenji MISUMI, Yoshikiyo KASHII, Mikio MIMURA (Received September 30, 1999)

Holographic RAM for optical fiber communications

Holography. Casey Soileau Physics 173 Professor David Kleinfeld UCSD Spring 2011 June 9 th, 2011

Scanning X-ray microscopy with a single photon counting 2D detector

A novel tunable diode laser using volume holographic gratings

Holography as a tool for advanced learning of optics and photonics

A high-resolution fringe printer for studying synthetic holograms

HOLOGRAPHY EXPERIMENT 25. Equipment List:-

Superresolution imaging method using phaseshifting digital lensless Fourier holography

Wavelength Stabilization of HPDL Array Fast-Axis Collimation Optic with integrated VHG

Stereoscopic Hologram

Circular Dichroism Microscopy Free from Commingling Linear Dichroism via Discretely Modulated Circular Polarization

High resolution digital transmission microscopy : a Fourier holography approach

Option G 4:Diffraction

Optical Information Processing. Adolf W. Lohmann. Edited by Stefan Sinzinger. Ch>

Physics 3340 Spring Fourier Optics

Optical transfer function shaping and depth of focus by using a phase only filter

Phase imaging digital holography for biological microscopy

Exp No.(8) Fourier optics Optical filtering

Applying of refractive beam shapers of circular symmetry to generate non-circular shapes of homogenized laser beams

Digital confocal microscope

Testing Aspherics Using Two-Wavelength Holography

A liquid crystal spatial light phase modulator and its applications

Resolution improvement by single-exposure superresolved interferometric microscopy with a monochrome sensor

Lensfree on-chip microscopy over a wide fieldof-view using pixel super-resolution

Experimental demonstration of polarization-assisted transverse and axial optical superresolution

This document is downloaded from DR-NTU, Nanyang Technological University Library, Singapore.

Characterization of microlenses by digital holographic microscopy

Resolution Enhancement in Phase Microscopy: a Review

Analysis of retinal images for retinal projection type super multiview 3D head-mounted display

Sensitive measurement of partial coherence using a pinhole array

APPLICATION OF A POINT-DIFFRACTION INTERFEROMETER TO UNSTEADY SHOCK WAVE PHENOMENA

Measurement of the Modulation Transfer Function (MTF) of a camera lens. Laboratoire d Enseignement Expérimental (LEnsE)

Supplementary Figure 1. Effect of the spacer thickness on the resonance properties of the gold and silver metasurface layers.

MASSACHUSETTS INSTITUTE OF TECHNOLOGY. 2.71/2.710 Optics Spring 14 Practice Problems Posted May 11, 2014

Holography. Introduction

Optical design of a high resolution vision lens

Two-step-only phase-shifting interferometry with optimized detector bandwidth for microscopy of live cells

PHY 431 Homework Set #5 Due Nov. 20 at the start of class

Optical Coherence: Recreation of the Experiment of Thompson and Wolf

LEOK-3 Optics Experiment kit

Diffraction lens in imaging spectrometer

Coded aperture correlation holography a new type of incoherent digital holograms

Design Description Document

The diffraction of light

BEAM SHAPING OPTICS TO IMPROVE HOLOGRAPHIC AND INTERFEROMETRIC NANOMANUFACTURING TECHNIQUES Paper N405 ABSTRACT

1 Introduction. Research Article

High-brightness and high-efficiency fiber-coupled module for fiber laser pump with advanced laser diode

A 3D Profile Parallel Detecting System Based on Differential Confocal Microscopy. Y.H. Wang, X.F. Yu and Y.T. Fei

Signal and Noise scaling factors in digital holography

LOS 1 LASER OPTICS SET

Exam 4. Name: Class: Date: Multiple Choice Identify the choice that best completes the statement or answers the question.

Introduction to Optofluidics. 1-5 June Use of spatial light modulators (SLM) for beam shaping and optical tweezers

Physics 3340 Spring 2005

Simple interferometric fringe stabilization by CCD-based feedback control

EE119 Introduction to Optical Engineering Spring 2002 Final Exam. Name:

Multi-spectral acoustical imaging

Metrology and Sensing

Wavefront sensing by an aperiodic diffractive microlens array

Shaping light in microscopy:

Dynamic beam shaping with programmable diffractive optics

Radial Polarization Converter With LC Driver USER MANUAL

DIGITAL holographic techniques to capture, process and

Optics and Lasers. Matt Young. Including Fibers and Optical Waveguides

Opto-VLSI-based reconfigurable photonic RF filter

Space bandwidth conditions for efficient phase-shifting digital holographic microscopy

MASSACHUSETTS INSTITUTE OF TECHNOLOGY Department of Electrical Engineering and Computer Science

PROCEEDINGS OF SPIE. Measurement of the modulation transfer function (MTF) of a camera lens

Development of a new multi-wavelength confocal surface profilometer for in-situ automatic optical inspection (AOI)

Evaluation of infrared collimators for testing thermal imaging systems

Transcription:

arxiv:1211.0336v1 [physics.optics] 2 Nov 2012 Atsushi Shiraki 1, Yusuke Taniguchi 2, Tomoyoshi Shimobaba 2, Nobuyuki Masuda 2,Tomoyoshi Ito 2 1 Deparment of Information and Computer Engineering, Kisarazu National College of Technology, 2-11-1, Kiyomidaihigashi, Kisarazu-shi, Chiba 292-0041, Japan 2 Graduate School of Engineering, Chiba University, 1-33, Yayoi-cho, Inage-ku, Chiba-shi, Chiba 263-8522, Japan E-mail: shiraki@j.kisarazu.ac.jp Abstract. This study developed handheld and low-cost digital holographic microscopy(dhm) by adopting an in-line type hologram, a webcam, a high power RGB light emitting diode (LED), and a pinhole. It cost less than 20,000 yen (approximately 250 US dollars at 80 yen/dollar), and was approximately 120 mm 80 mm 55 mm in size. In addition, by adjusting the recording-distance of a hologram, the lateral resolution power at the most suitable distance was 17.5 µm. Furthermore, this DHM was developed for use in open source libraries, and is therefore low-cost and can be easily developed by anyone. In this research, it is the feature to cut down cost and size and to improve the lateral resolution power further rather than existing reports. This DHM will be a useful application in fieldwork, education, and so forth. Keywords DHM, handheld, low-cost, web camera, high power RGB LED

Handheld and low-cost digital holographic microscopy 2 1. Introduction Microscope technology is used in various fields due to its: (1) High resolution, (2) Extensive field of view, and (3) Three-dimensional observation. An optical microscope can improve the resolution power using a lens with high magnification. However, the field of view becomes narrow. It is theoretically difficult to solve this problem with an optical microscope. Digital holographic microscopy (DHM) attempts to solve this problem using a principle different to that of the optical microscope[1, 2]. DHM introduces holographic technology into microscope technology, giving both a high resolution power and extensive field of view, for example Ref.[3]. Furthermore, DHM enables observation of an object three-dimensionally. Although the optical system of DHM is large and expensive, low-cost DHM systems have been reported [4, 5]. Both studies used a digital camera for consumers as the recording device of a hologram. In Ref.[4], the optical system was constructed with a digital camera made by Canon, a laser diode, and some lenses. The cost was approximately $1,000, and it realized a lateral resolution power of 2.8 µm. The system was about 35 cm in size in the optical axis direction. Ref.[4] is the first paper to suggest using a digital camera for consumers to make low-cost DHM. However, the system was not conducive to handheld size, and the cost was slightly higher. In addition, real-time reconstruction was difficult because the system used a digital camera for consumers[6]. Inourstudy, wesucceeded inreducing thecostandthesize ofdhm.thecost isless than 20,000 yen(approximately 240 US dollars at 83 yen/dollar), and it is approximately 120 mm 80 mm 55 mm in size. In addition, by adjusting the recording distance of a hologram, the lateral resolution power at the most suitable distance is 17.5 µm. Therefore, this DHM is useful in fieldwork, education, and so forth. In addition, we can obtain a reconstruction image in real-time by using a web camera and graphics processing unit (GPU) acceleration[6]. This paper is structured as follows. Section 2, describes the recording and reconstruction method of a hologram. Section 3 and 4 explain the hardware configuration and the software used. Section 5 evaluates this system. The final section discusses the study results and proposes further studies. 2. Recording and reconstruction method This study aims to achieve price reduction and downsizing of DHM. Therefore, we adopted the in-line type DHM as the recording setup of holograms, which does not need optical parts, such as lenses[7, 8]. The conceptual figure of the in-line type DHM is shown in Figure 1. Thus, there is no need to divide the object light and reference light unlike in Mach-Zehnder type DHM, which reduces the cost of lenses. Next, we explain the reconstruction technique. In DHM, computer simulation performs reconstruction from a hologram. Here, in order to pursue real-time reconstruction, it is necessary to change the formula of optical propagation into a form

Handheld and low-cost digital holographic microscopy 3 Figure 1. Conceptual figure of in-line type DHM. that is easy to control by computer. The angular spectrum method, Fresnel diffraction, Fraunhofer diffraction, and so forth are approximation techniques. These are properly used according to conditions, such as propagation distance. In order to realize the downsizing of DHM, which is one of the purposes of this study, it is necessary to shorten the distance between the object and the hologram side (charge coupled device (CCD) camera). Therefore, we adopted the angular spectrum method, which is effective when the distance of the object and the hologram side is short. The angular spectrum method is shown below. [ ] A(f x,f y ) = F a(ξ, η), = a(ξ,η)exp{ 2πi(ξf x +ηf y )}dξdη. (1) U(f x,f y ) = A(f x,f y )exp( 2πif z d). (2) ] u(x,y) = F [U(f 1 x,f y ), = U(f x,f y )exp{2πi(xf x +yf y )}df x df y. (3) Here, the operators F[ ] and F 1 [ ] indicate Fourier and inverse Fourier transforms, and the subscripts x, y, and z indicate the horizontal, vertical, and depth components. (ξ, η) and (x, y) are the coordinates of the hologram side and the observation side, respectively. d is the distance between the hologram side and the observation side, and λ is the wavelength of the light. f x, f y and f z are the spatial frequency components of each axis, and f z is shown as follows. 1 f z = λ 2 f2 x fy. 2 (4) If we calculate using the angular spectrum method, Discrete Fourier Transform (DFT) is calculated on a large scale and at high-speed by Fast Fourier Transform (FFT). Therefore, it is possible to perform recording of a hologram and reconstruction by computer simulation, and if we use a GPU, the reconstruction is obtained in real-time.

Handheld and low-cost digital holographic microscopy 4 Figure 2. Composition of the handheld DHM system to create. 3. Hardware design In order to realize low-cost and downsizing of DHM, we build hardware as shown in Figure 2. We used a web camera, HD Pro Webcam C910 made by Logicool, as the CCD camera and removed the lens of the web camera for focusing an image on the CCD camera because the lens is not required for DHM application. The resolution for photography of this web camera is 1920 1080 pixels. Using a commercial web camera, the cost can be sharply reduced. The OSTCXBC1C1S, which is a high power RGBlight emitting Diode (LED) made by OptoSupply, is used as the light source. This LED features the ability to allow a 350 ma current to be passed through it. Another feature is having three wavelengths, 470 nm, 525 nm, and 625 nm. The light of this LED is used as the point light source passing through the pinhole. The diameter of the pinhole is 5µm (the product number of the pinhole made by KOYO is 2412). Although the pinhole is generally positioned on the focal side of an object lens, in our study, the perfect lensless optical system is used instead of an object lens for cost reduction. As a substitute, a pinhole is directly attached to the LED. Moreover, in order to adjust the distance of the light source, an object, and a CCD camera, variable length supports are used. The actual DHM system is shown in Figure 3. When recording a hologram, the actual DHM system of Figure 3 is housed in a shading case. 4. Software design Software for recording a hologram and the reconstruction from a hologram is required. OpenCV [9], which is the open source library by which Intel is developed and released, is used to record the hologram. Using OpenCV, control of a web camera and editing of a recorded hologram can be performed. Moreover, it is necessary to calculate the diffraction of light for reconstruction from a hologram. Therefore, the CWO++ library,

Handheld and low-cost digital holographic microscopy 5 (a) (b) Figure 3. Photograph of DHM system. (a) DHM system without a shading case. (b) Handheld DHM system. Table 1. Parts used and costs for the DHM system. parts costs[yen] CCD camera 7,092 high power RGB-LED 500 pinhole 9,800 shading case 1,400 total 18,792 which is an open source library for optical calculation, is used[10]. The CWO++ library is equipped with several commands used when optical calculation is performed. Therefore, calculation of the angle spectrum method adopted as this research can calculate on CPU or GPU by a simple description. Thus, use of the OpenCV and CWO++ library is cost free, enables simplification of programming and improvement in the calculation speed. 5. Performance 5.1. Cost and size The costs of the parts used are shown in Table 1. As shown in Table 1, it is constituted for less than 20,000 yen (approximately 250 US dollars at 80 yen/dollar). Moreover, the size of DHM is equal to the size of the shading case, and it is 120 mm 80 mm 55 mm.

Handheld and low-cost digital holographic microscopy 6 Figure 4. Hologram of element number 5 of group number 4 of the USAF test target. Figure 5. Reconstruction image of element number 5 of group number 4 of the USAF test target. 5.2. Measurement of the lateral resolution power In order to measure the lateral resolution power of the DHM system created in this study, the USAF1951 test pattern was used. In addition, a blue light with the shortest wavelength was used as the light source. To increase the lateral resolution power, we adjusted the positions of the CCD camera and the object using the variable length support. In this system, the lateral resolution power was highest when the distance from the light source to the object was 3 mm and the distance from the light source to the CCD camera was 13 mm. The hologram recorded in this condition is shown in Figure 4. Furthermore, the reconstruction image obtained from Figure 4 is shown in Figure 5. Figure 4 and Figure 5 show that those have resolved element number 5 of group number 4. As mentioned above, the lateral resolution power of this DHM is 17.5 µm. 6. Conclusion and discussion In this study, we reduced the cost of DHM to less than 20,000 yen (approximately 250 US dollars at 80 yen/dollar), and reduced the size to 120 mm 80 mm 55 mm. The lateral resolution power of this DHM was 17.5 µm. The downsizing of DHM is useful for fieldwork, and the reduction in the cost of DHM and use of an open

Handheld and low-cost digital holographic microscopy 7 source library are of great benefit in educational environments. Moreover, since the LED light source of RGB is used in this study, various wavelengths can be controlled. This is applicable to wavefront recovery using two-wave digital holography[2], two-wave Laplacian reconstruction[11], or two-wave Laplacian reconstruction[12]. In this study, since the angular spectrum method was used, a reconstruction image could be obtained in the same resolution as a hologram. The scaled angular spectrum method [13] that can calculate diffraction at different sampling rates on a hologram and reconstructed image is useful for this DHM system because it enables observation of a detailed reconstructed-image with a smaller sampling rate on the reconstructed image. Adding such a function of DHM and increasing convenience are future study considerations. References [1] U. Schnars and W. Juptner, Direct recording of holograms by a CCD target and numerical Reconstruction, Appl.Opt. 33, 179 181 (1994). [2] M. K. Kim, Principles and techniques of digital holographic microscopy, SPIE Rev. 1, 018005 (2010). [3] T. Shimobaba, N. Masuda, Y. Ichihashi and T. Ito, Real-time digital holographic microscopy observable in multi-view and multi-resolution, J. Opt. 12, 065402 (4pp) (2010). [4] http://www.me.jhu.edu/lefd/shc/lpholo/lphindex.htm [5] T. G. Dimiduk, E. A. Kosheleva, D. Kaz, R. McGorty, E. J. Gardel, and V. N. Manoharan, A Simple, Inexpensive Holographic Microscope, in Digital Holography and Three-Dimensional Imaging, OSA Technical Digest (CD) (Optical Society of America, 2010), paper JMA38. [6] T. Shimobaba, Y. Sato, M. Takenouchi, J. Miura and T. Ito, Real-Time Digital Holographic Microscopy using the Graphic Processing Unit, Opt. Express 16, 11776 11781 (2008). [7] L. Repetto, E. Piano, and C. Pontiggia, Lensless digital holographic microscope with lightemitting diode illumination, Opt. Lett. 29, 1132 1134 (2004). [8] J. Garcia-Sucerquia, W. Xu, S. K. Jericho, P. Klages, M. H. Jericho, and H. J. Kreuzer, Digital in-line holographic microscopy, Appl. Opt. 45, 836 850 (2006). [9] http://sourceforge.net/projects/opencvlibrary/ [10] T. Shimobaba, J. Weng, T. Sakurai, N. Okada, T. Nishitsuji, N. Takada, A. Shiraki, N. Masuda and T. Ito, Computational wave optics library for C++: CWO++ library, Comput. Phys. Commun. 183, 1124 1138 (2012). [11] J. P. Ryle, D. Li, and J. T. Sheridan, Dual wavelength digital holographic Laplacian reconstruction, Opt. Lett. 35, 3018 3020 (2010). [12] T. Shimobaba, N. Masuda and T. Ito, Numerical investigation of holographic wavefront retrieval using Laplacian reconstruction, Digital Holography and Three-Dimensional Imaging(DH) DH2012 JM3A.51(2012). [13] T. Shimobaba, N. Masuda and T. Ito, Angular spectrum method for different sampling rates on source and destination planes: Scaled angular spectrum method, Digital Holography and Three-Dimensional Imaging(DH) DH2012 DTu2C.3 (2012).