A New Profile Measurement Method for Thin Film Surface

Similar documents
Profile Measurement of Resist Surface Using Multi-Array-Probe System

Bringing Answers to the Surface

Surface Finish Measurement Methods and Instrumentation

Manufacturing Metrology Team

Measurement of Microscopic Three-dimensional Profiles with High Accuracy and Simple Operation

Development of a new multi-wavelength confocal surface profilometer for in-situ automatic optical inspection (AOI)

By: Louise Brown, PhD, Advanced Engineered Materials Group, National Physical Laboratory.

Comparison of resolution specifications for micro- and nanometer measurement techniques

1 Introduction. Research Article

Optotop. 3D Topography. Roughness (Ra opt, Rq opt, and Rz opt) Height Distribution. Porosity Distribution. Effective Contact Area

nanovea.com PROFILOMETERS 3D Non Contact Metrology

Figure for the aim4np Report

Supplementary Materials for

Optical Characterization and Defect Inspection for 3D Stacked IC Technology

Standard Operating Procedure of Atomic Force Microscope (Anasys afm+)

Open Access Structural Parameters Optimum Design of the New Type of Optical Aiming

CHAPTER 2 POLARIZATION SPLITTER- ROTATOR BASED ON A DOUBLE- ETCHED DIRECTIONAL COUPLER

Measurement of Surface Profile and Layer Cross-section with Wide Field of View and High Precision

Large Field of View, High Spatial Resolution, Surface Measurements

Confocal Imaging Through Scattering Media with a Volume Holographic Filter

SENSOR+TEST Conference SENSOR 2009 Proceedings II

Keywords: Bracing bracket connection, local deformation, selective pallet racks, shear stiffness, spine bracings.

Advanced 3D Optical Profiler using Grasshopper3 USB3 Vision camera

Nanonics Systems are the Only SPMs that Allow for On-line Integration with Standard MicroRaman Geometries

The End of Thresholds: Subwavelength Optical Linewidth Measurement Using the Flux-Area Technique

Capabilities of Flip Chip Defects Inspection Method by Using Laser Techniques

Fabrication of suspended micro-structures using diffsuser lithography on negative photoresist

Specifying and Measuring Nanometer Surface Properties. Alson E. Hatheway

Indentation Cantilevers

Development of innovative fringe locking strategies for vibration-resistant white light vertical scanning interferometry (VSI)

of surface microstructure

Part 5-1: Lithography

Investigation of the Near-field Distribution at Novel Nanometric Aperture Laser

Super High Vertical Resolution Non-Contact 3D Surface Profiler BW-S500/BW-D500 Series

SUPPLEMENTARY INFORMATION

Asphere and Freeform Measurement 101

Etch, Deposition, and Metrology Options for Cost-Effective Thin-Film Bulk Acoustic Resonator (FBAR) Production

Design of Vibration Sensor Based on Fiber Bragg Grating

Uncertainty in measurements of micro-patterned thin film thickness using Nanometrological AFM - Reliability of parameters for base straight line -

Investigate in magnetic micro and nano structures by Magnetic Force Microscopy (MFM)

A 3D Profile Parallel Detecting System Based on Differential Confocal Microscopy. Y.H. Wang, X.F. Yu and Y.T. Fei

High Resolution Backside Imaging and Thermography using a Numerical Aperture Increasing Lens

attosnom I: Topography and Force Images NANOSCOPY APPLICATION NOTE M06 RELATED PRODUCTS G

Integrated Focusing Photoresist Microlenses on AlGaAs Top-Emitting VCSELs

Fiber-optic Michelson Interferometer Sensor Fabricated by Femtosecond Lasers

Understanding Optical Specifications

Application Note #548 AcuityXR Technology Significantly Enhances Lateral Resolution of White-Light Optical Profilers

Open Access Application of Partial Discharge Online Monitoring Technology in ± 660kV Converter Transformer

Optical Microscopy and Imaging ( Part 2 )

Analysis of Focus Errors in Lithography using Phase-Shift Monitors

VISUAL PHYSICS ONLINE DEPTH STUDY: ELECTRON MICROSCOPES

University of Huddersfield Repository

--> Buy True-PDF --> Auto-delivered in 0~10 minutes. JY/T

A Study on Pore-forming Agent in the Resin Bond Diamond Wheel Used for Silicon Wafer Back-grinding

Ultra-thin Die Characterization for Stack-die Packaging

Open Access The Application of Digital Image Processing Method in Range Finding by Camera

Waveguiding in PMMA photonic crystals

POLYMER MICROSTRUCTURE WITH TILTED MICROPILLAR ARRAY AND METHOD OF FABRICATING THE SAME

Impact of the light coupling on the sensing properties of photonic crystal cavity modes Kumar Saurav* a,b, Nicolas Le Thomas a,b,

PROCEEDINGS OF SPIE. Measurement of low-order aberrations with an autostigmatic microscope

ANALYSIS OF SURFACE ROUGHNESS WITH VARIATION IN SHEAR AND RAKE ANGLE

Length section: New calibration and research services

Pulsed Laser Ablation of Polymers for Display Applications

Project Staff: Timothy A. Savas, Michael E. Walsh, Thomas B. O'Reilly, Dr. Mark L. Schattenburg, and Professor Henry I. Smith

Prepare Sample 3.1. Place Sample in Stage. Replace Probe (optional) Align Laser 3.2. Probe Approach 3.3. Optimize Feedback 3.4. Scan Sample 3.

3-5μm F-P Tunable Filter Array based on MEMS technology

Proceeding The Alignment Method for Linear Scale Projection Lithography Based on CCD Image Analysis

Open Access AOA and TDOA-Based a Novel Three Dimensional Location Algorithm in Wireless Sensor Network

Effects of spherical aberrations on micro welding of glass using ultra short laser pulses

OPC Rectification of Random Space Patterns in 193nm Lithography

Nanovie. Scanning Tunnelling Microscope

Difrotec Product & Services. Ultra high accuracy interferometry & custom optical solutions

A scanning tunneling microscopy based potentiometry technique and its application to the local sensing of the spin Hall effect

New CD-SEM System for 100-nm Node Process

2. Pulsed Acoustic Microscopy and Picosecond Ultrasonics

Outline: Introduction: What is SPM, history STM AFM Image treatment Advanced SPM techniques Applications in semiconductor research and industry

Akiyama-Probe (A-Probe) guide

Computer Generated Holograms for Optical Testing

TOPOGRAPHY & ROUGHNESS TESTING OF SANDPAPER SURFACE

attocfm I for Surface Quality Inspection NANOSCOPY APPLICATION NOTE M01 RELATED PRODUCTS G

Open Access Design of Optical Fiber Fabry-Perot Sensors Based on Intensity and Phase with Parallel Processing

Test procedures Page: 1 of 5

Exhibit 2 Declaration of Dr. Chris Mack

Optical Issues in Photolithography

Conference Paper Cantilever Beam Metal-Contact MEMS Switch

Measurement of channel depth by using a general microscope based on depth of focus

A study of key optical profiler parameters for form error measurement

J. C. Wyant Fall, 2012 Optics Optical Testing and Testing Instrumentation

Standard Operating Procedure

CD-SEM for 65-nm Process Node

i- Line Photoresist Development: Replacement Evaluation of OiR

DOE Project: Resist Characterization

This writeup is adapted from Fall 2002, final project report for by Robert Winsor.

Open Access Parallel Resonant DC Link Inverter for Thermoacoustic Power Generation

Three-dimensional quantitative phase measurement by Commonpath Digital Holographic Microscopy

Department of Physics, Dalian University of Technology, Dalian

Sinusoidal wavelength-scanning common-path interferometer with a beam-scanning system for measurement of film thickness variations

3D Optical Motion Analysis of Micro Systems. Heinrich Steger, Polytec GmbH, Waldbronn

Surface Topography and Alignment Effects in UV-Modified Polyimide Films with Micron Size Patterns

MICROBUMP LITHOGRAPHY FOR 3D STACKING APPLICATIONS

Transcription:

Send Orders for Reprints to reprints@benthamscience.ae 480 The Open Automation and Control Systems Journal, 2014, 6, 480-487 A New Profile Measurement Method for Thin Film Surface Open Access ShuJie Liu 1,*, Yuan L. Zhang 1 and Hong C. Zhang 1,2 1 School of Mechanical Engineering Dalian University of Technology Dalian, China, 116024 2 Department of Industrial Engineering, Texas Tech University, Lubbock, USA, TX 79409 Abstract: In order to measure the surface profile of the thin films in wide area with high accuracy, the research on the new measurement method was conducted and many patents on measurement method and system were researched. Based on the physical properties of soft thin film, the method of using white interferometer and ball cantilevers for measuring the surface profile of thin film is proposed. Then, the multi-ball-cantilever AFM system using a multi-ball-cantilever is developed that had 8 cantilevers in 2 mm and each cantilever had the ball stylus with diameter of 10.9 µm. Using this system, the measurement experiments on the step and transparent material was conducted. The results on the step that the precision of the system s measuring error is less than 2% and the measuring standard deviation is less than 1 nm. The result on the step indicated that it is possible to measure the surface with high accuracy. The result on the transparent material showed the feasibility for measuring the thin film by this developed system. Keywords: Multi-ball cantilever, surface profile measurement, thin film, white light interferometer. 1. INTRODUCTION The development of the semiconductor industry is moving towards miniaturization and high integration. Semiconductor industry with high-performance and low-cost is the motivation of the development of information technology. Lithography plays an extremely important role in semiconductor integration process. The short-wavelength light irradiation method is usually used to improve the resolution, but the impact on the exposure is increasing because of the photoresist surface irregularity, which is due to the shallow depth of focus if the wavelength is reduced. In traditional lithography, the surface profile of photoresist film does not need to be measured, and only the exposure in a required range of accuracy needs to be controlled through correcting the measurement system calibration and the measurement systems focus. But as the semiconductor technology moving toward a more accurate direction, the photoresist surface irregularity has a significant impact on the exposure's accuracy even when the difference of surface unevenness is only several 10nm. Therefore, the surface profile measurement of the photoresist and the corresponding measurement methods are key issues to be studied in the semiconductor industry [1-3]. Now, surface profile measurement methods are mainly divided into two categories. One is non-contact measurement technique by use of light exposure. The other is contact measurement technique by contacting with the surface of the specimen. Non-contact measurement technique is to use the light irradiation to measure the surface of the specimen, without forces acting on it and this method belongs to the non-invasive measurement [4]. And there is no deformation in the process of measuring. The instruments, such as white light interferometer and confocal microscope, are widely used in the wide-area measurement. Since there is no contact scanning in the measurement, the non-contact measurement has high-speed. In the measurement accuracy, the noncontact measurement can get high accuracy in the vertical by the phase and intensity of light, but the lateral resolution, depending on the half-wavelength of light, is lower than the vertical resolution. Meanwhile, the experimental material exposed to the light waves cannot receive the reflected light signals due to the improper angles of the optical axis, which could not be measured. Because of the multiple reflections of the light, the correct profile of the translucent film couldn't be measured. When the thickness of a film is only several hundred nm, which is approximately several times the wavelength of light, the reflected lights transmitted from the film and from the bottom surface will interfere, and if they are considered as the reflected light to resolve the relationship of the phase and the height of light, the correct profile cannot be observed. However, this problem will not be obvious when the film has sufficient thickness. Contact measurement is with a high reliability, especially in the vertical, and 1nm can be measured. The measurement accuracy in the lateral can be improved by selecting the appropriate contact. However, the weakness of contact measurement is that the contact force may cause deformation of the specimen surface. Moreover, the time cost in a wide area measurement is relatively increased due to the contact with the surface. Atomic force microscope (AFM) and surface roughness measuring gauge are some typical examples of contact measuring instrument [5, 6]. We study some patents on measurement methods and systems. Patent US2014020140 [7], titled multi-head probe 1874-4443/14 2014 Bentham Open

Surface Profile Measurement Method The Open Automation and Control Systems Journal, 2014, Volume 6 481 Fig. (1). Multiple interferences phenomenon in the film. and scanning method thereof provides a multi-head probe suitable for an atomic force microscopy (AFM) comprising of a tip base, a single cantilever beam and at least two tips. The tip base has a tip end, which is grounded to form a surface. The cantilever beam is connected to the tip base and for supporting the tip base. Patent CN102257353 [8] titled device and method for the three-dimensional optical measurement of strongly reflective or transparent objects relates to a device for three-dimensionally measuring an object, comprising of a first projection device, having a first infrared light source for projecting a displaceable first pattern onto the object, and at least one image recording device for recording images of the object in an infrared spectral range. Patent US20120218560 [9], titled method and apparatus for performing film thickness measurement using white light scanning interferometry relates to a method and an apparatus for measuring the thickness of a transparent film by broad band interferometry, comprising of the steps of preparing a correlogram of the film by an interferometer, applying a Fourier transformation to the said correlogram to obtain a Fourier phase function, removing a linear component thereof by applying a second integral transformation to the remaining non-linear components to obtain an integral amplitude function of the said non-linear component. Identifying the peak location of said integral amplitude function and determining the thickness of the film as the double value of the abscissa at said peak location and considering a refractive index of a film which is dependent on wavelength. Patent WO2014024614 [10], titled optical measurement device and optical measurement system provides an optical measurement device and an optical measurement system whereby test subject information and measurement data can be reliably correlated with each other. Patent US20140025336 [11], titled shape measuring apparatus and control method of shape measuring apparatus, is a control method of a shape measuring apparatus which divides a curve indicating a movement path of a probe into a plurality of sections. 2. SURFACE PROFILE MEASUREMENT METHOD OF THIN FILM 2.1. The Thin Film Properties In this study, the measurement object (photoresist) has the following characteristics: (1). the film thickness of several hundred nm; (2). the surface shape changes mitigation, the undulation within 0.2 mm-20 mm and the amplitude of several tens of nm; (3). "soft" material, the experimental elastic modulus is about 30GPa, which is 1/7 times of silicon's; (4). transparent or translucent. The problem of non-contact measurement is due to the translucency of the film and its thickness, and the thickness of photoresist is about several hundred nm, which easily leads to the phenomenon of interference as show in Fig. (1). Thus, it is difficult to measure the thin film using white light interferometer or confocal microscopy. Using contact measuring method will require a lot of time to measure a large surface area profile of photoresist coated on the wafer. The surface wave level of the resist film measured is several hundred microns, and the difference of the height is 10 nm. In order to get the shape of the resist film, high-precision measurements in the vertical is needed while the lateral resolution does not have high requirements, and some special high-frequency component does not need to be detected. Therefore, the advantages of contact measurement with high lateral resolution are negated [12]. What s worth noting is that by optical measurement method it is difficult to realize the high accuracy measurement of the thin-film in principle, and contact measurement can obtain relatively accurate results if the force effects do not cause defects on the surface for the resist film, even though it requires considerable time [13]. If the advantages of the optical measurement (high speed and without deformation) are used, the problems we faced can be solved. Thus, the surface profile measurement technique of the thin films combining optical and mechanical measurement is proposed [14]. 2.2. The Principle of the Measuring Method The surface profile measurement method proposed above is expressed in Fig. (2). The main characteristics are showed in the following: (A) combining optical measurement (white light interferometer) and mechanical contact (multi ball cantilever) The fundamental of the proposed measurement method is showed in Fig. (3). The surface profile of the thin film can be obtained indirectly without multiple reflections by optical measurement instrument and the medium.

482 The Open Automation and Control Systems Journal, 2014, Volume 6 Liu et al. Fig. (2). Single-phase full bridge inverter. Fig. (3). The fundamental of the proposed measurement method. Fig. (4). A linear array of spherical probes. (B) multiple spherical probes are used in the contact part The probes are spherical, which can reduce the effect of the contact on the film, and multiple probes are used to achieve wide-area measurements. A linear array of spherical probes is used in the measurement, as shown in Fig. (4). To avoid interference, optical measurement is used to measure the upper surface of scanning probe. To reduce the impact of the contact on shapes, spherical probes with large diameter are adopted. (C) The application of the white interferometer in optical measurement part The application of the white interferometer can realize large area scanning measurement. In the study, the New View's white light interferometer is used as optical measuring instruments. Three-dimensional geometry of the highprecision surface is detected by the white light interference principle. Surface roughness, waviness, roughness, step height, etc. can be qualitative and quantitative measured through flotation worktable, which has the function of stitching and micro-geometry error analysis. The concrete aspects are demonstrated as following: (1). the measurement range in the vertical is 1 nm-15000 µm, (2). the reproducibility of the step height standard is less than 0.5%, (3). the measurement error of the step height standard is less than 0.75%, (4). the reproducibility of RMS is 0.1nm. A multi-ball cantilever measuring device was constructed as shown in Fig. (5). The multi-ball cantilever is NANO-

Surface Profile Measurement Method The Open Automation and Control Systems Journal, 2014, Volume 6 483 Fig. (5). The multi-ball cantilever measurement system. Fig. (6). A step height standard. WORLD Arrow TL8-50 which uses 8 cantilevers spaced 250 µm apart, and each cantilever holds a ball stylus 10.9 µm in diameter. The white interferometer used for the experimental studies is a ZYGO NewView5000. Using the interference strength detection method, New View 5000 can detect height information with a height resolution of 0.1 nm and profile heights ranging from 1nm to 15000 µm.the measuring performance of the instrument is examined by the following basic experiments [15]. A step height standard that is a nominal 52 nm step in height and 100 µm in width is measured in the experiment, as shown in Fig. (6). In this experiment, three cantilevers are used to simplify the evaluation. Step portion and both side flat portions are measured using three neighboring ball cantilevers with 250 µm spacing. In order to calibrate the variation in the diameter of the ball on each probe, and the thickness of the cantilever and the mounting position of the cantilever, the sample plane was measured. The measurement was performed in ten different points. In measurement, there is a height difference between the middle cantilever and the center of the either side cantilever, the step value is calculated from this difference. Here, this calculation method is called three-point relative method. Fig. (7) shows the measurement image in the experiment from white light interferometer. Processing the data and the measure results are gained in Table 1. The measurement error is less than 2% and the standard deviation is 0.9nm. The experiments achieve the purpose of high-accuracy measurements. Table 1. Result of the step height standard measurement. 3. MEASUREMENT EXPERIMENT The Times of Measurement The Height (nm) 3.1. Height Standard 1 50.8 2 51.6 3 50.7 4 51.5 5 52.5 6 49.8 The mean 51.2 The standard deviation 0.9

484 The Open Automation and Control Systems Journal, 2014, Volume 6 Liu et al. Fig. (7). Measurement image using three ball cantilevers. Fig. (8). Transparent resin sample. Fig. (9). The measurement results by white light interferometer, Profile cannot be measured correctly by white light interferometer because of multiple interference. 3.2. Measurement of Step Height Standard In order to confirm whether it is possible to measure transparent thin films using the developed apparatus, it is necessary to compare with the actual value. This experiment uses the resin film with the thickness of 200-400 nm and the diameter 50-60 µm, as shown in Fig. (8). The white interferometer measuring causes multiple reflections and the discontinuous measurement profile are obtained as in Fig. (9). The resin film sample used in this experiment is not the reference sample with real value. Therefore, in order to

Surface Profile Measurement Method The Open Automation and Control Systems Journal, 2014, Volume 6 485 Fig. (10). Measurement method. Fig. (11). Measurement process. verify the measurement result, the sample surface is measured when it was with and without gold evaporation. Thickness of the gold deposition is 25-30 nm. When gold is deposited on the film, the surface becomes reflective and does not let any light pass through; making measurement in the white light interferometer possible. For film samples used being 50-60 µm in diameter, one cantilever only will be in contact with the sample because multi-ball cantilever has 250 µm intervals. Therefore, it is possible to apply the threepoint relative method here. It is decided to measure the height of each portion of the thin film in this measurement method. The measurement method and measurement process are shown in Fig. (10) and Fig. (11) respectively. We compare the profile by the developed apparatus and by white light interferometer. The measurement results based on four conditions (the presence or absence of gold deposition and using developed multi-cantilever apparatus or only white light interferometer) were shown in Fig. (12). A good measurement result is not possible for the effect of multiple reflections in Fig. (12) (a). Comparing Fig. (12) (b), (c), and (d), we have similar results. Focusing on the measurement result b, measurement is performed by the developed device on the sample without coating, since it is by the mechanical contact; it is not encounter the effects of multiple reflections. The result shapes can be considered which are not so different in the Fig. (12) (b) and (d), and there is little change in shape due to the gold deposition. Experiments show that the developed device may overcome the effect of the multiple reflections, and the surface profile of the film can be measured. 4. CURRENT & FUTURE DEVELOPMENTS In order to realize fast, highly accurate measurement of the surface profile of photoresist, the paper proposed a measuring method combing optical measurement and mechanical contact and a multi-ball cantilever AFM system is constructed for the task. The experimental apparatus is evaluated by the basic experiments on the step height standard and the surface profile measurement on the translucent film. In the experiment of step height standard, the results are observed that the measurement error is less than 2% and the standard deviation is within 0.9 nm, which proved the feasibility of using this device to measure the step height standard with high accuracy. Then, the translucent thin film is measured by the proposed system, which demonstrated that this system can be used in measurement of the soft thin film, where the white light interferometer couldn't work. The result on the transparent material showed the feasibility of measuring the thin film by this developed system. In future, a study will be conducted on the accuracy of the scanning measuring methods. Patent TW201346213 [16], titled Calibration of an optical metrology system for critical dimension application matching presents methods and systems for matching critical dimension measurement applications at high precision across multiple optical metrology systems. Calibration of multiple probes should be the point in our measurement system. Now the device is using one-dimensional probe on a straight line, in the future, 2- dementional set probes measurement method will also be studied.

486 The Open Automation and Control Systems Journal, 2014, Volume 6 Liu et al. (a) Sample without coating is measured by white light interferometer. (b) Sample without coating is measured by developed instrument. (c) Sample with coating is measured by white light interferometer. Fig. (12). Measurement results. (d) Sample with coating is measured by developed instrument.

Surface Profile Measurement Method The Open Automation and Control Systems Journal, 2014, Volume 6 487 CONFLICT OF INTEREST The authors confirm that this article content has no conflict of interest. ACKNOWLEDGEMENTS This work is jointly supported by the National Natural Science Fund of China (No. 51205043) and Specialized Research Fund for the Doctoral Program of Higher Education (No. 20120041120033). REFERENCES [1] ITRS. International Technology Roadmap for Semiconductor (ITRS 2009), 2010. [2] W. Conley, and J. Bendik, Is ArF the final wavelength? Proceeding SPIE, 2004, 5376, pp. 16-20. [3] Z. X. Wu, and Y Q. Huang, Study on optical methods for 3-D shape measurement. Optical Technique, vol. 32, pp. 654-658, 2006. [4] J. Wang, Y. Zhao, Sh. L. Zhang, et al. Nano Metrology and Nano Metrology Testing Technology (1). Aviation Metrology & Measurement Technology, vol. 15, no. 5, pp. 3-5, 1995. [5] J. Wang, Y. Zhao, Sh. L. Zhang, et al. Nano metrology and nano metrology testing technology (2). Aviation Metrology & Measurement Technology, vol. 15, no. 5, pp. 3-5, 1995. [6] L. C. Zhang, and J. S. Gao, Developments of DUV coating technology in CIOM, Optics and Precision Engineering, vol. 20, pp. 2395-2401, 2011. [7] F. G. Tseng, and J. M. Chang, Multi-head probe and scanning method thereof, U. S. Patent 2014020140, 2014 [8] D. Nabs, and K. Gensecke, Device and method for the threedimensional optical measurement of strongly reflective or transparent objects, Available from http://patentscope.wipo.int/search/en/detail.jsf?docid=cn84819348&recnum=5&maxrec=46&off ice=&prevfilter=&sortoption=pub+date+desc&querystring=all NAMES%3A%28AFM%29&tab=NationalBiblio, 2011 [9] K. N. Joo, Method and apparatus for performing film thickness measurement using white light scanning interferometry, U. S. Patent 20120218560, 2012 [10] H. Sakai, Optical measurement device and optical measurement system, WO2014024614, 2014 [11] T. Noda, and H. Deguchi, Shape measuring apparatus and control method of shape measuring apparatus, U. S. Patent 20140025336, 2014 [12] K. Fukuda, T. Ito, and M. Kobayashi, Nano indentation of the Resist for Electron Beam Lithography. JSME annual meeting, vol. 4, pp. 105-106, 2003. [13] S. Wang, T. B. Xie, and S. P. Chang, Combined profilometer for ultra-precision surface topography, Optics and Precision Engineering, vol. 19, no.4, pp. 828-835, 2011. [14] S. Liu, S. Nagasawa, S. Takahashi, and K. Takamasu, Development of a multi-ball-cantilever AFM for measuring resist surface. Journal of Robotics and Mechatronics, vol. 18, no. 6, pp. 698-704, 2006. [15] C. Zygo, New View Accessories, Product guide for the New View 3D Surface Profiler, 2001. [16] K. Flock, L. Rotter, and M. Arain, Calibration of an optical metrology system for critical dimension application matching, Available from http://worldwide.espacenet.com/publicationdetails/biblio?db=worldwide.espacenet.com&ii=7&nd=3&adjacent =true&locale=en_ep&ft=d&date=20131116&cc=tw&nr=201 346213A&KC=A, TW201346213, 2013 Received: September 22, 2014 Revised: November 03, 2014 Accepted: November 06, 2014 Liu et al.; Licensee Bentham Open. This is an open access article licensed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/bync/3.0/) which permits unrestricted, non-commercial use, distribution and reproduction in any medium, provided the work is properly cited.