KCS-U200 relay - Latching, 2 pole

Similar documents
RC-19A relay - Current monitoring

D4-U200 relay module - 4-pole

TTBCR 200 relay - Delay-on drop-out,

TDB4-U200 relay - Timer, delay-on, 4 pole

AG 400 relay - Gold plated, 4 contacts

BD relay - Industrial latching power

MTDV4-U200 relay - Voltage monitoring,

TBSBAO 400 relay - Delay-on pull-in,

MTDV4 relay - Voltage monitoring,

UBC 200 relay - Voltage monitoring

UTC relay - Voltage monitoring & off delay

UB 001 relay - 1 level load shedding

TELAU 400 relay - Delay-on pull-in or

UB 200 relay - Voltage monitoring

C relay - Safety critical, 9 contacts

407 relay - Latching, safety critical, 40 contacts Datasheet

D-U200 Instantaneous relay Part of D-platform

CM relay - 7 contacts + 2 gold contacts

CK relay - safety critical, 9 contacts

D-B Power relay, high DC breaking capacity Part of D-platform

MSV200 - Hall effect transducer

D Instantaneous relay Part of D-platform

MSA Hall effect transducer

MSA500 - Hall effect transducer

BM 400 relay - Mixed load, 4 contacts

Mors Smitt Industrial Technology. High performance plug-in relays

V88 socket - Spring clamp terminal,

Portable relay tester PRT-MS1 User manual

Mors Smitt Industrial Technology. Industrial current & voltage sensors. Hall effect current & voltage sensors

Mors Smitt Railway Technology. Railway relays

Manual Signal calibration box (SCB)

Mors Smitt Industrial Technology

OKT OKR Series APPLICATIONS. Shipbuilding

SERIES KC RELAY NONLATCH 3PDT, 25 AMP

2 Pole CO, 8 A Plug-in 2 CO (DPDT) 1 CO (SPDT) 8/15 16/25* 250/ /400 2,000 4, /0.5/ /0.5/ (5/5) 300 (10/5)

Classification Contact form Enclosure rating Terminal shapes Model Minimum packing unit Standard. SPST-NO (1a) Fully sealed PCB terminal

Nieaf-Smitt Maritime. Analogue panel indicators

Type Nominal voltage (V) Code HSV V


MINIATURE POWER RELAY IN DS RELAY SERIES FEATURES resistance ORDERING INFORMATION. Ex. DSP 1 L DC12V R

Ordering Information. PCB Relay G6RL. Model Number Legend: Low-profile power relay with maximum switching of 10 A

27/04/2015

22 Series Relays. Technical Data...1. Specifications...2. Model Number Structure - Relays...3. Model Number Selection

RF Signal Relays AXICOM. HF3 Relay

PCB Relay. Ordering Information. SPST-NO Type Breaks 10-A Loads; SPST-NO + SPST-NC Type Breaks 8-A Load

PCB Relay SPST-NO G6CU-1117P-US G6CU-1114P-US G6CU-1117C-US G6CU-1114C-US SPST-NO + SPST- G6CU-2117P-US G6CU-2114P-US G6CU-2117C-US G6CU-2114C-US

3. Contact Form A: SPST-NO

POWER RELAY. FTR-K3-WS Series. 1 POLE - High Capacity 25A Type FTR-K1 SERIES FEATURES

PCB relay for DC voltage, polarized, monostable or bistable

YL SERIES RELAY LATCH DC COIL 4PDT, LOW LEVEL TO 5 AMP

Ref: HLSR 10-P/SP3, HLSR 20-P/SP3, HLSR 40-P/SP3, HLSR 50-P/SP3

SLIM COMPACT SAFETY RELAY

PCB Relay. Contact form Terminal Single-side stable Single-winding latching Double-winding latching

LOW-PROFILE SURFACE-MOUNT RELAY. Characteristics. Initial breakdown voltage. Initial surge voltage. Temperature rise* 2 (at 20 C) Max.

Classification Enclosure rating Contact form Model Standard Flux protection SPST-NO G6RL-1A

G6C. Miniature High Capacity Relays with SPST-NO 10A and SPST-NO + SPST-NC 8A. Model Number Legend. Application Examples.

Relion 605 series Self-Powered Feeder Protection REJ603 Product Guide

Mors Smitt Industrial Technology

Low profile safety relay with forcibly guided double contacts FEATURES. Relay height, 14.5mm. 4a2b

AC/DC Current Probe GCP-100 QUICK START GUIDE ISO-9001 CERTIFIED MANUFACTURER

Reyrolle Protection Devices. 7PG21 Solkor R/Rf Pilot Wire Current Differential Protection. Answers for energy

Compact size 2 Form A and 2 Form A 1 Form B 35A power relays for energy management and industrial equipment. Conditions. Mirror contact mechanisms

To be Discontinued FBR46 SERIES. MINIATURE RELAY 2 POLES 1 to 2 A (FOR SIGNAL SWITCHING) RoHS compliant FEATURES

Power PCB Relay. To Order: Select the part number and add the desired coil voltage rating (e.g., G6B-1114-US-DC6).

Ordering Information. Latching Relay MMK. Available Models. Models Conforming to Auxiliary Power Relay Specifications

C20.en. Power contactors for AC and DC CT1115 and CT1130. Connect - Contact - Control

I P. /dt. di p V S+ Applications. Standards. 1) IEC ed1.0: 2007; IEC : ed1.0: 2012

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

I P. /dt. di p V S Applications. Standards 1) IEC : 2007; IEC : ) IEC : 2016; IEC : 2017

2 pole (1 NO + 1 NC) 1 NO + 1 NC 2 NO + 2 NC, 3 NO + 1 NC 4 NO + 2 NC Rated current / Max. peak current Rated load AC1

Relays & Sockets. RF1V Force Guided Relays/SF1V Relay Sockets. Certification Organization/ File Number. UL/c-UL File No.

60 Series - General purpose relays 6-10 A. Features Plug-in mount 10 A General purpose relay

AXICOM Telecom-, Signal and RF Relays. FX2 Relay Nov. 07 Rev. E ECOC: JM10

Classification Enclosure rating Contact form Contact material

AXICOM Telecom-, Signal and RF Relays. D2n V23105 Relay Nov. 07 Rev A ECOC: JM10

POWER RELAY. FTR-K3-WG Series. 1 POLE - 25A - 1.5mm contact gap FTR-K1 SERIES FEATURES

MT4 Relay. 4 pole telecom/signal relay Through Hole Type (THT) Non-polarized. non-latching 1 coil. Features. Typical applications

COMPACT HIGH POWER RELAY

G5Q. Ordering Information. Specifications. PCB Relay. Compact, High Isolation Relay J COIL RATINGS. 638 PCB Relay G5Q

PART NUMBERING SYSTEM

1 POLE - 1 to 2A (For Signal Switching)

ULTRA LOW PROFILE 2 A POLARIZED RELAY. mm inch. Initial breakdown voltage

Ref: HLSR 10-SM, HLSR 16-SM, HLSR 20-SM, HLSR 32-SM, HLSR 40-SM, HLSR 50-SM

MK-S (New Models) General-purpose Relays. New Super MK Relays. Models with Latching Lever Added to the Series. Features. Model Number Structure

Introducing. CII FCA-150 Series Relay 50 Amps, 1PST/NO (DM) CII FCAC-150 Series Relay 50 Amps, 1PST/NO (DM) with 1PDT Auxiliary Contacts

2 PDT Coil supply. Contacts rated at. Contact rating per pole and load type. Load Current in 100,000 cycles 100,000 cycles

HIGH VOLTAGE AND CURRENT CUT-OFF CAPACITY IN A COMPACT PACKAGE FEATURES

MK-S (New Models) General-purpose Relays. New Super MK Relays. Models with Latching Lever Added to the Series. Features. Model Number Structure

Classification Terminal Shape Contact form Enclosure rating Model Rated coil voltage

Model Number Structure


OMRON MK-I / -S RELAY

Zelio Control Measurement Relays

Ref: HLSR 10-SM/SP33, HLSR 20-SM/SP33, HLSR 32-SM/SP33, HLSR 40-P/SP33, HLSR 50-SM/SP33

40 Series - Miniature P.C.B. Relays A

RISH EM 3490 SS Kilowatt Hour Energy Meter With Rs485 RISH EM 3490 SS. Application : Product Features: Indication: Pulse Indication:

Type Poles Contact configuration Rated voltage Model G7S-4A2B 24 VDC 3PST-NO, 3PST-NC

3.5 mm contact pin pitch 1 Pole 12 A PCB direct or via socket

SPST-NO SPDT DPST-NO DPDT

SPAC265-8W. AC-DC power supply module. Features. Description. Applications

Transcription:

- Latching, 2 pole Datasheet Features Latching (bistable) relay Compact design 2 C/O contacts 2 galvanic isolated coils Weld-no-transfer contacts Flash barrier 2.8 x 0.8 faston connections Transparent cover Benefits Description Bistable railway relay with two change-over contacts. The contacts remain in the last powered position. Bistable by means of two coils and a mechanical rocker mechanism. The two separate coils are galvanically isolated. The contacts are weld-no-transfer contacts: they are mechanically forced in the same position. The KCS-U200 relay is a compact design relay connected with 2.8 x 0.8 mm fastons. The construction of the relay and choice of materials makes the KCS-U200 relay suitable to withstand low and high temperatures, shock & vibrating and dry to humid environments. Application These relay series are designed for demanding rolling stock applications. The KCS-U200 is used in applications where two contacts are used in one relay and the contacts are set and reset with permanent power or impulses. Proven reliable Long term availability Easy to maintain Low life cycle cost No maintenance Railway compliancy EN 50155 Electronic equipment used on rolling stock for railway applications IEC 60571 Electronic equipment used on railway vehicles IEC 60077 Electrical equipment for rolling stock in railway applications IEC 60947 Low voltage switch gear and control gear IEC 61373 Rolling stock equipment - Shock and vibration test IEC 60947-5-4 Electromechanical components for control applications. This standard examines both coil and contact specifications in depth EN 50121 Electromagnetic compatibility for railway applications NF F 16-101/102, EN 45545-2 Fire behaviour - Railway rolling stock NF F 62-002 On-off contact relays and fixed connections 1

Functional and connection diagrams Timing diagram Relay pin correspondence Connection diagram 2

Coil characteristics Minimum impulse time 25 ms Operating voltage range 0.7...1.25 Unom Nominal power consumption - during interval time < 1.1 W - after pulse time 25 ms Type Unom (VDC) Umin (VDC) Umax (VDC) Rcoil (Ω)* Inom (ma) KCS-U201 24 16.8 30 500 48 KCS-U202 48 33.6 60 2060 23 KCS-U203 72 50.4 90 3200 15 * 110 77.0 137.5 ** 12 KCS-U205 96 67.2 120 7800 12 KCS-U206 12 8.4 15 137 88 KCS-U207 36 25.2 45 1300 29 Other types on request * The Rcoil is measured at room temperature and has a tolerance of ± 10% ** For 110 VDC: use KCS-U205 in series with external seriesresistor of 1800 Ω / 0.4 W Remarks: Umin is the must-operate voltage at which the relay has picked up in all circumstances (worst-case situation), in practice the relay picks up at a lower voltage Always select the nominal voltage as close as possible to the actual voltage om the application Contact characteristics Amount and type of contacts 2 C/O Maximum make current 15 A Maximum continuous current 6 A (AC1 ; IEC 60947) Maximum switching voltage 300 VDC (then max. current = 300 ma) 250 VAC (then max. current = 2.6 A) Maximum switching capacity See graph page 6 Contact resistance 15 mω (initial) Material Ag standard (optional Au on Ag) Contact gap Contact force 0.3 mm > 200 mn Note : contacts cannot have a different position (forced contacts, weld-no-transfer) 3

Electrical characteristics Dielectric strength EN 50155 Pole-pole IEC 60255-5 3 kv, 50 Hz, 1 min Cont-coil IEC 60077 3 kv, 50 Hz, 1 min Insulation between open contacts 1 kv; 50 Hz; 1 min Pulse withstanding IEC 60255-5 5 kv (1.2 / 50 μs) Mechanical characteristics Mechanical life Maximum switching frequency Weight 30 x 10 6 operations Mechanical: 3600 ops/h Electrical: 1200 ops/h 75 g Environmental characteristics Environmental EN 50125-1 and IEC 60077-1 Vibration IEC 61373, Category I, Class B, Body mounted Shock IEC 61373, Category I, Class B, Body mounted Operating temperature -25 C...+85 C (optional: -40 o C) Humidity 90 % Salt mist IEC 60068-2-11, class ST4 Damp heat IEC 60068-2-30, Test method Db variant 1 Protection IEC 60529, IP40 (relay on socket) Fire & smoke NF F 16-101, NF F16-102, TS 45545-2 Insulation materials Cover: polycarbonate Base: polyester 4

Dimensions (mm) 5

Options Code Description Remark Cannot be combined with: B Magnetic arc blow out C Low temperature (-40 C) E * Au; Gold plated contacts (10 µm) Y Double make / double break contacts 1 C/O DM/DB Keying Coil coding relay and socket Colour coding Coloured cover for coil voltage coding * Gold plated contacts characteristics Material Maximum switching voltage Maximum switching current Minimum switching voltage Minimum switching current Ag, 10 µm gold plated 60 V (higher voltages may be possible, contact Mors Smitt for more information) 400 ma (at higher rate gold will evaporate, then the standard silver contact rating of minimum 10 ma and 12 V is valid) 5 V 1 ma Also version with PCB mounting available: KCP-U200 relay 6

Current breaking capacity Max Switching Capacity Contact Life 1000 100 Watt DC 2 contacts in serie % of max switching cap. DC resistive 100 10 DC inductive DC 1 contact 10 10 100 1000 1 0,10 1,00 10,00 100,00 Volt No of ops (x10 6 ) Step 1: Determine switching voltage out of the application. Step 2: Pick the maximum switching capacity (in Watt) at this voltage, out of graph maximum switching capacity. Step 3: Calculate the actual switched load (in Watt) out of the application. Step 4: Calculate the % of maximum switching capacity: Actual load Max switching capacity Step 5: Pick the life at this load out of the graph Electrical life expectancy. 7

Instructions Installation, operation & inspection Installation Before installation or working on the relay: disconnect the power supply first! Connect wiring according to the terminal identification. Check to ensure that the coil connection polarity is not reversed. Relays can be mounted tightly together to save space. Warning! - Never use silicon in the proximity of the relays. - Do not use the relay in the presence of flammable gas as the arc generated from switching could cause ignition. Operation After installation always apply the rated voltage to the coil to check correct operation. Before actual use of relays, it is advised to switch the load several times with the contacts. The contacts will both be electrically and mechanically cleaned due to the positive wiping action. Sometimes a contact can build up increased contact resistance (< 15 mw when new). When using silver contacts one can clean the contact by switching a contact load a few times using >24 VDC & ~2 A. Increased contact resistance is not always problematic, as it depends on circuit conditions. In general a contact resistance of 1 Ω is no problem, consult Mors Smitt for more information. Condensation in the relay is possible when the coil is energised (warm) and the outside, environmental temperature is cold. This is a normal phenomenon and will not affect the function of the relay. Materials in the relay have no hygroscopic properties. Inspection Correct operation of the relay can easily be checked as the transparent cover provides good visibility of the moving contacts. If the relay does not seem to operate correctly, check for presence of the appropriate coil voltage and polarity using a suitable multimeter. If the relay doesn t work after inspection, replace the relay unit with a similar model. Do not attempt to open the relay cover or try to repair. Contacts are calibrated and in balance, touching can affect proper operation. Also re soldering may affect correct operation. Most relay defects are caused by installation faults such as over voltage, spikes/transients, high/short current far exceeding the relay specifications. When returning the relays for investigation, please provide all information on the RMA form. Send defective relays back to the manufacturer for repair or replacement. Normal wear and tear or external causes are excluded from warranty. 8

Ordering scheme Configuration: KCS-U2 02 - E 1. Relay model 2. Coil voltage 3. Options This example represents a KCS-U202-E Description: KCS-U200 series relay, Unom: 48 VDC, gold plated contacts 1. Relay model KCS - U2 2. Coil voltages 01 24 VDC 02 48 VDC 03 72 VDC 05 96 VDC (*) 06 12 VDC 07 36 VDC * can be used for 110 VDC with an external series resistor of 1800 Ω / 0.4 W 3. Options B Magnetic arc blow out C Low temperature (-40 o C) E Gold plated contacts Y Double make / double break Upon ordering indicate keying if necessary. 9

DS-KCS-U200 V1.4 November 2016 Mors Smitt France SAS Tour Rosny 2, Avenue du Général de Gaulle, F - 93118 Rosny-sous-Bois Cedex, FRANCE T +33 (0)1 4812 1440, F +33 (0)1 4855 9001 E sales.msf@wabtec.com Mors Smitt Asia Ltd. 29/F., Fun Towers, 35 Hung To Road Kwun Tong, Kowloon, HONG KONG SAR T +852 2343 5555, F +852 2343 6555 E sales.msa@wabtec.com Mors Smitt B.V. Vrieslantlaan 6, 3526 AA Utrecht, NETHERLANDS T +31 (0)30 288 1311, F +31 (0)30 289 8816 E sales.msbv@wabtec.com Mors Smitt Technologies Inc. 1010 Johnson Drive, Buffalo Grove, IL 60089-6918, USA T +1 847 777 6497, F +1 847 520 2222 E salesmst@wabtec.com Mors Smitt UK Ltd. Graycar Business Park, Barton under Needwood, Burton on Trent, Staffordshire, DE13 8EN, UK T +44 (0)1283 722650 F +44 (0)1283 722651 E sales.msuk@wabtec.com RMS Mors Smitt Ltd. 6 Anzed Court, Mulgrave, VIC 3170, AUSTRALIA T +61 (0)3 8544 1200 F +61 (0)3 8544 1201 E rms@rmspl.com.au (c) Copyright 2015 All rights reserved. Nothing from this edition may be multiplied, or made public in any form or manner, either electronically, mechanically, by photocopying, recording, or in any manner, without prior written consent from Mors Smitt. This also applies to accompanying drawings and diagrams. Due to a policy of continuous development Mors Smitt reserves the right to alter the equipment specification and description outlined in this datasheet without prior notice and no part of this publication shall be deemed to be part of any contract for the equipment unless specifically referred to as an inclusion within such contract. Mors Smitt does not warrant that any of the information contained herein is complete, accurate, free from potential errors, or fit for any particular purpose. Mors Smitt does not accept any responsibility arising from any party s use of the information in this document.