Model A-5. Mid Range Wet/Wet Differential Pressure Transducer. A-5, Datenblatt Seite 1 DESCRIPTION FEATURES

Similar documents
Model 41E. Precision Low Profile Load Cell DESCRIPTION FEATURES

Model RH. Rod End In-line Tension Load Cell DESCRIPTION FEATURES

Model RGH. Rod End In-line Compression/Tension Load Cell DESCRIPTION FEATURES

Model UG. Ultra Precision Universal Canister Load Cell DESCRIPTION FEATURES

Load Cells LOAD CELLS

Models Tension/Compression Pancake Load Cell Model 3174 with tension base DESCRIPTION FEATURES

Model Tension/Compression Pancake Load Cell DESCRIPTION FEATURES

SETUP SUNSTAR 传感与控制 Model 3173 PERFORMANCE SPECIFICATIONS Load range 1 Accuracy 0.07 % Non-linearity Hysteresis Repeatabilit

Model FP2000. Configurable Pressure Transducer DESCRIPTION FEATURES

Model TS. Transducer Simulator User s Guide. Sensotec Sensors

Pressure Transducer FP2000

Model TMS DIN-Flange Torque Measurement System DESCRIPTION APPLICATIONS FEATURES

Model FP2000. Configurable Pressure Transducer DESCRIPTION FEATURES

Heavy Duty Pressure Transducers

Non-Submersible Industrial Pressure Transducer

TRANSDUCER IN-LINE AMPLIFIER

Model FP2000. Configurable Pressure Transducer DESCRIPTION FEATURES

Hall-effect Position Sensors with Sealed Housing The 103SR Series Hall-effect position sensor assemblies are sealed in aluminum or stainless-steel thr

Issue D. Installation Instructions for the Quadrature Speed and Direction Sensors SNG-Q Series. Sensing and Internet of Things

Quadrature Speed and Direction Sensors. SNG-Q Series. Datasheet

SMART Position Sensor, 100 and 180 Arc Configurations

TRANSDUCER IN-LINE AMPLIFIER

TECHNICAL MANUAL. SERIES AP5103 DIN-Rail DC Strain Gage Conditioner ISO 9001/AS9100

U5300 Industrial Pressure Transducer

MICRO SWITCH Key-Operated Safety Interlock Switch GK Series Issue 1. Datasheet FEATURES DESCRIPTION POTENTIAL APPLICATIONS DIFFERENTIATION

MODEL UBP-10 UNIVERSAL IN-LINE TRANSDUCER AMPLIFIER BI-POLAR SUPPLY, 0-10 VOLT OUTPUT

WOI Series. Limitless Wireless Operator Interface DESCRIPTION

mv/v Output MELT PRESSURE TRANSMITTERS I3 SERIES TECHNICAL SPECIFICATIONS

Heavy Duty Pressure Transducers. PX2 Series 1 bar to 46 bar 100 kpa to 4.6 MPa 15 psi to 667 psi. Datasheet

PX2 Series Heavy Duty Pressure Transducer

M5200 Industrial Pressure Transducer

PX2 Series Heavy Duty Pressure Transducer

MICROMACHINED SILICON MODULAR PRESSURE SENSOR

SS421 Series. Solid State Hall-effect Sensors Adjustable Hall-Effect Under-speed Detectors

Miniature pressure sensor

U5300 Industrial Pressure Transducer

KING-GAGE KING. ES2 Liquid Level Transmitter. Installation and Operation Instructions ma Liquid Level Transmitter EX-1834

Limitless Wireless Multi-Protocol Receiver WMPR Series Issue 2. Datasheet FEATURES DESCRIPTION POTENTIAL INDUSTRIAL APPLICATIONS

MICRO SWITCH Electromechanical Safety Switches GSS Series Issue 1. Datasheet FEATURES DESCRIPTION POTENTIAL APPLICATIONS DIFFERENTIATION

XPC10 High temperature miniature pressure sensor

M5200 Industrial Pressure Transducer

TECHNICAL MANUAL. SERIES AP5202 DC Strain Gage In-Line Amplifier ISO 9001/AS9100

FEATURES Heavy Industrial CE Approval 10 V/m EMI Protection Reverse Polarity Protection on Input Short Circuit Protection on Output Up to ±0.1% Accura

Signal Conditioning Amplifier

Ricochet Alphasonic Level Transmitter Model LA15/20 Owner s Manual

Broadband Current Probe Series Operation Manual

2-wire level transmitter

Heavy Duty Pressure Transducers. PX2 Series 1 bar to 46 bar 100 kpa to 4.6 MPa 15 psi to 667 psi. Datasheet

User's Manual: Series 450T AC Current Input (External Sensor), AC-Powered Transmitters

TPFADA FLUSH DIAPHRAGM PRESSURE TRANSMITTER WITH DIGITAL AUTOZERO & SPAN

Series 500. Owner s Manual. Analog Transmitters by Data Industrial. Data Industrial. Data Industrial 2/95 PN 72806

o-ring grease can be used to hold the o-ring in the groove during installation.

U5200 Industrial Pressure Transducer

Broadband Current Probe Series Operation Manual

Instruction Manual. HB Series Mini Level Sensor

Operating Manual. Model Channel. DC Signal Conditioner Amplifier

KING-GAGE ES2. Installation and Operation Instructions Manual. Electronic Liquid Level Transmitter. ESR Serial No. Versions and Slimline Versions

Freescale Semiconductor Data Sheet: Technical Data

Transducer transmitter BILT 4 II 2(1) G. Technical Manual

UNCONTROLLED WHEN PRINTED

American Power Design, Inc.

MM1/MM2 CONTROL VALVES CLOSED LOOP PROPORTIONAL PRESSURE CONTROLS THE FUTURE OF CONTROL TM

o-ring grease can be used to hold the o-ring in the groove during installation.

Kotron Model 82 CE RF Level Transmitter

User's Manual: Series 350T AC Current Input (External Sensor), DC-Powered Transmitters

THE FUTURE OF CONTROLTM MM1/MM2 CONTROL VALVES CLOSED LOOP PROPORTIONAL PRESSURE CONTROLS

HOD /BBA HOD /BBA

Model A. DIN Rail Strain Gage Conditioner. Installation and Operating Manual

MINCO PRODUCTS, INC Commerce Lane, Minneapolis, Minnesota U.S.A. Telephone: (763) FAX: (763)

Model 4800 O P E R AT I O N M A N U A L L O A D C E L L S U M M I N G T R A N S M I T T E R

2-Wire Toroidal Conductivity Transmitters Series APT2000 Specifications

MEAS CAL ALARM CONF APT2000 TC

ED701 General Industry Pressure Transmitter

Characteristic Condition Min. Typ. Max. Unit. Response time 3 µs Output voltage swing: VOM- VOM+ 0.4 V s - 0.4

SL300 Snow Depth Sensor USL300 SNOW DEPTH SENSOR. Revision User Manual

Load Cell Accessories and Services

KING-GAGE. D/P Transmitter 4-20 ma Pressure Transmitter ma Pressure Transmitter. Operation/Calibration Manual

Advanced Test Equipment Rentals ATEC (2832)

SB.5.1 MODEL STRAIN GAGE CONDITIONER INSTRUCTION MANUAL. Instrument Series

MODEL 3810/2 Line Impedance Stabilization Network

Operating manual. Force transducer with strain gage measuring system C9B. A en. hvordan man bruger astrologi med tibetanske medicin

Ricochet Alphasonic Level Transmitter Model LA15 Owner s Manual

ISA100 Wireless Pressure Sensor. WPS Series 0 psi to 50 psi, 200 psi, 500 psi, 1000 psi, 1500 psi, 5000 psi, or 10,000 psi.

Torque Sensor Accessories and Services

User Guide DIRECT-DRIVE

Echotel Model 911/921 Ultrasonic Level Switches

STT 3000 Smart Temperature Transmitter

Aero Support Ltd, 70 Weydon Hill Road, Farnham, Surrey, GU9 8NY, U.K.

M5800 Pressure Transducer with Rotatable Display

HOD /BBA HOD /BBA

HC900 Remote Termination Panel (RTP) For Analog Inputs

2001A. 200KHz Function Generator Instruction Manual. 99 Washington Street Melrose, MA Phone Toll Free

CAB LINK User Guide. Radial Engineering Ltd Kebet Way, Port Coquitlam BC V3C 5M5 Tel: Fax:

KING-GAGE. D/P Transmitter 4 20 ma Pressure Transmitter ma Pressure Transmitter. Operation/Calibration Manual

Series APD4059. For Load Cells/Pressure Transducer Transmitters. Field Rangeable, with Calibration Resistor. Standard Features.

Model 9305 Fast Preamplifier Operating and Service Manual

HT2 Humidity Transmitter HT2 Humidity and Temperature Transmitter Installation and Operating Instructions

This manual should be read in its entirety prior to operation of the TS200 Test Set Page 2 of 9

Signal Conditioning Amplifier

Twinline Effects Loop Router User Guide True to the Music

Transcription:

A-5, Datenblatt Seite 1 Model A-5 Mid Range Wet/Wet Differential Pressure Transducer DESCRIPTION Model A-5 mid-range Wet/Wet Differential is a bonded foil strain gage transducers designed to accept fluid in both ports and measure differential pressure ranges from 50 psid to 750 psid. Standard features such as overload stops and stainless steel construction provide unit durability in rugged industrial environments. Each is bi-directional and achieves accuracies of 0.5 % full scale. A variety of standard options are available with the Model A-5 including the traditional removable pressure adaptors for cleaning purposes, extended temperature ranges, alternative pressure ports, internal amplifiers options, and electrical terminations. FEATURES 0.5% accuracy 50 psid to 750 psid mv/v (standard), 4 ma to 20 ma, 0 Vdc to 5 Vdc, or 0 Vdc to 10 Vdc output Intrinsically safe available (2N option only) 10 CE approved 11

A-5, Datenblatt Seite 2 Model A-5 PERFORMANCE SPECIFICATIONS Pressure ranges 50, 75, 100, 150, 200, 300, 500, 750 psid Accuracy ±0.5 % full scale Linearity ±0.25 % full scale (typical) Hysteresis ±0.13 % full scale (typical) Non-repeatability ±0.07 % full scale (typical) Output (standard) 2 mv/v (nominal) Line pressure 1500 psi Resolution Infinite ENVIRONMENTAL SPECIFICATIONS Temperature, operating -54 C to 121 C [-65 F to 250 F] Temperature, compensated 15 C to 71 C [60 F to 160 F] Temperature, effect, zero ±0.75 % full scale/100 F Temperature, effect, span ±1.0 % reading/100 F ELECTRICAL SPECIFICATIONS Strain gage type Bonded foil Excitation (calibration) 10 Vdc Excitation (acceptable) Up to 10 Vdc or ac Insulation resistance 5000 mohm @ 50 Vdc Bridge resistance 350 ohm Shunt calibration data Included Elec. termination (std) Bendix PTIH-10-6P or equivalent (hermetic stainless) Mating connector (not incl.) Bendix PT06A-10-6S or equiv. (AA111) MECHANICAL SPECIFICATIONS Media Gas, liquid Overload-safe 1500 psi Pressure port 1/8-27 NPT female (2) Dead volume 0.25 cu. in Wetted parts material 17-4 PH stainless steel Weight 2,3 kg [5 lb] Case material Stainless steel OPTION CODES Range Code Pressure ranges (psid) Temperature compensation Internal amplifiers Internal amp enhancements Many range/option combinations are available in our quick-ship and fast-track manufacture programs. Please see http://sensing.honeywell.com/ TMsensor-ship for updated listings. 50, 75, 100, 150, 200, 300, 500, 750 1a. 60 F to 160 F 1b. 30 F to 130 F 1c. 0 F to 185 F 1d. -20 F to 130 F 1e. -20 F to 200 F 1f. 70 F to 250 F 2b. 4 wire ±5 Vdc 2c. 0 Vdc to 5 Vdc 2j. 4 ma to 20 ma (3-wire) output 2k. 4 ma to 20 ma (two-wire) output 12 1j. 0 C to 50 C 1i. -65 F to 250 F 6 1m. -25 C to 110 C 1g. 70 F to 325 F 6 1h. 70 F to 400 F 6 2n. (2N) 4 ma to 20 ma (2 wire) intrinsically safe 12 2t. 0 Vdc to 10 Vdc 2u. Unamplified, mv/v output 3a. Input/output isolation 8 3d. Remote buffered shunt calibration Pressure ports 5 5h. 1/8-27 NPT female (2) 5c. 7/16 in -20 UNF female (per MS33656E4) Electrical termination Shunt calibration Special calibration Wetted diaphragm 6a. Bendix PTIH-10-6P (or equiv.) 6 pin (max. 250 F) 6b. MS type connector to mate MS3106-14S- 6S (max. 160 F) 1 6e. Integral cable: Teflon (-54 C to 245 C) 6f. Integral cable: PVC (-30 C to 70 C) 8a. Precision internal resistor 6 6g. Integral cable: Neoprene (-20 C to 80 C) 1 6h. Integral cable: Silicone (-54 C to 150 C) 6i. Integral underwater cable (8 m [26 ft]) (max. 80 C) 1 6j. 1/2-14 conduit fitting with 1,5 m [5 ft] of 4 conductor PVC cable 9a. 10 point (5 up/5 down) 20% increments @ 20 C 9b. 20 point (10 up/10 down) 10% increments @ 20 C 17-4 PH stainless steel 10a. 316 stainless steel Bridge type 11a. Square bridge 6 11b. Symmetrical bridge 6 11c. Square & symmetrical bridge 6 Zero & 14a. No access span adjustment 14b. Top access 6 O-ring seals 26a. Metal 26b. Vi-Ton 26c. Teflon Interfaces 53e. Signature calibration 6 53t. TEDS IEEE 1451.4 module 9

A-5, Datenblatt Seite 3 Mid Range Wet/Wet Differential Pressure Transducer INTERNAL AMPLIFIERS Amplifier specifications Voltage output: Option 2b Voltage output: Option 2c Output signal ±5 V 0 V to 5 V or ±5 V @ 5 ma Input power (voltage) ±15 V or 26 Vdc to 32 Vdc Voltage output: Option 2t 0 V to 10 V or ±10 V @ 5 ma Current threewire: Option 2j Current twowire: Option 2k Intrinsically safe amp: Option 2n (2N)*** 4 ma to 20 ma 4 ma to 20 ma 4 ma to 20 ma 11 Vdc to 28 Vdc 15 Vdc to 28 Vdc 22 Vdc to 32 Vdc 9 Vdc to 32 Vdc 9 Vdc to 28 Vdc Input power (current) 45 ma 40 ma 40 ma 65 ma 4 ma to 28 ma 4 ma to 24 ma Freq. resp (amp) 3000 Hz 3000 Hz 3000 Hz 2500 Hz 300 Hz 2000 Hz Power supply rejection 60 db 60 db 60 db 60 db 60 db 60 db Operating temperature -20 F to 185 F -20 F to 185 F -20 F to 185 F 0 F to 185 F 0 F to 185 F -20 F to 185 F Reverse volt. protection Yes Yes Yes Yes Yes Yes Short circuit protection Momentary Momentary Momentary Yes Yes Yes Wiring code: connector (std) 2 Wiring code: cable 2,3,4 B Output common C Supply return Bl Output common G Supply return C Supply return ** C Supply return** C Supply return** B No connection C No connection E Case ground F No connection Bl (+) Output W Case ground B No connection C No connection E Case ground F No connection Bl (+) Output W Case ground * Black and green wires are internally connected. ** Pins B and C are internally connected. *** See Honeywell s Web site for the most up-to-date information regarding Intrinsically safe approvals. Ref #008-0547-00. MOUNTING DIMENSIONS AND CHARACTERISTICS TYPICAL SYSTEM DIAGRAM

A-5, Datenblatt Seite 4 Model A-5 Mid Range Wet/Wet Differential Pressure Transducer RANGE CODES Range Code Available ranges Range Code Available ranges BN ±50 psid CL ±200 psid BP ±75 psid CP ±300 psid BR ±100 psid CR ±500 psid CJ ±150 psid CT ±750 psid WIRING CODES Connector Unamplified A, B (+) excitation C, D (-) excitation E (-) output F (+) output NOTES 1. Availability varies according to range. 2. Interconnecting shunt cal. 1 terminal with shunt cal. 2 terminal provides 50% (unamplified units), 75% (4 ma to 20 ma 3-wire units) or 80% (voltage amplified units of full scale output for quick calibration. Shunt calibration comes standard with internal amplifier options 2b, 2c, 2t and 2j. 3. O=Orange, Y=Yellow, B=Blue, Bl=Black, R=Red, Br=Brown, W=White, G=Green. Color specifying cable and number or letter specifying connector. 4. No mating connector necessary for cable option. 5. Some pressure port options may require axial orientation. 6. Only available with unamplified option 2u. 7. Only available with amplified options. 8. Only available with Vdc output options 2b, 2c. 9. Consult factory for TEDS availability with amplified models. 10. Range dependent; consult factory. Termination dependent; consult factory. 11. Internal amp and termination dependent; consult factory. 12. 5000 ohm bridge required. Note: Unless otherwise specified on order, amplified units with 4 ma to 20 ma output will provide 4 ma at 0 psid and 20 ma at positive full scale and the unit will not operate in the negative direction. An available is to specify 4 ma at negative full scale and 20 ma at positive full scale. All amps add 2 in to housing. Warranty. Honeywell warrants goods of its manufacture as being free of defective materials and faulty workmanship. Honeywell s standard product warranty applies unless agreed to otherwise by Honeywell in writing; please refer to your order acknowledgement or consult your local sales office for specific warranty details. If warranted goods are returned to Honeywell during the period of coverage, Honeywell will repair or replace, at its option, without charge those items it finds defective. The foregoing is buyer s sole remedy and is in lieu of all warranties, expressed or implied, including those of merchantability and fitness for a particular purpose. In no event shall Honeywell be liable for consequential, special, or indirect damages. While we provide application assistance personally, through our literature and the Honeywell web site, it is up to the customer to determine the suitability of the product in the application. Specifications may change without notice. The information we supply is believed to be accurate and reliable as of this printing. However, we assume no responsibility for its use. WARNING PERSONAL INJURY DO NOT USE these products as safety or emergency stop devices or in any other application where failure of the product could result in personal injury. Failure to comply with these instructions could result in death or serious injury. WARNING MISUSE OF DOCUMENTATION The information presented in this catalogue is for reference only. DO NOT USE this document as product installation information. Complete installation, operation and maintenance information is provided in the instructions supplied with each product. Failure to comply with these instructions could result in death or serious injury. 008722-1-EN IL50 GLO May 2008 Copyright 2008 Honeywell International Inc. All rights reserved. ALTHEN GmbH Meß- und Sensortechnik Frankfurter Straße 150-152 65779 Kelkheim Tel.: +49 (0) 61 95-70 06 0 Fax: +49 (0) 61 95-70 06 66 info@althen.de althen.de ALTHEN GmbH 2014

Z, Datenblatt Seite 1 Model Z Mid Range Wet/Wet Differential Pressure Transducer DESCRIPTION Model Z mid-range Wet/Wet Differential is a bonded foil strain gage transducers designed to accept fluid in both ports and measure differential pressure ranges from 50 psid to 750 psid. Standard features such as overload stops and stainless steel construction provide unit durability in rugged industrial environments. Each is bi-directional and achieves accuracies of 0.25 % full scale. A variety of standard options are available with the Model Z including the traditional removable pressure adaptors for cleaning purposes, extended temperature ranges, alternative pressure ports, internal amplifiers options, and electrical terminations. FEATURES 0.25% accuracy 50 psid to 750 psid mv/v (standard), 4 ma to 20 ma, 0 Vdc to 5 Vdc, or 0 Vdc to 10 Vdc output Intrinsically safe available (2N option only) 10 CE approved 11

Z, Datenblatt Seite 2 Model Z PERFORMANCE SPECIFICATIONS Pressure ranges Accuracy Linearity Hysteresis Non-repeatability Output (standard) Line pressure Resolution 50, 75, 100, 150, 200, 300, 500, 750 psid ±0.25 % full scale ±0.15 % full scale (typical) ±0.10 % full scale (typical) ±0.05 % full scale (typical) 2 mv/v (nominal) 1500 psi Infinite ENVIRONMENTAL SPECIFICATIONS Temperature, operating Temperature, compensated -54 C to 121 C [-65 F to 250 F] 15 C to 71 C [60 F to 160 F] Temperature, effect, zero ±0.5 % full scale/100 F Temperature, effect, span ±0.5 % reading/100 F ELECTRICAL SPECIFICATIONS Strain gage type Excitation (calibration) Excitation (acceptable) Insulation resistance Bridge resistance Shunt calibration data Elec. termination (std) Mating connector (not incl.) Bonded foil 10 Vdc Up to 10 Vdc or ac 5000 mohm @ 50 Vdc 350 ohm Included PTIH-10-6P or equivalent (hermetic stainless) PT06A-10-6S or equiv. (AA111) MECHANICAL SPECIFICATIONS Media Gas, liquid Overload-safe 1500 psi Pressure port 1/8-27 NPT female (2) Dead volume 0.25 cu. in Wetted parts material 17-4 PH stainless steel Weight 2,3 kg [5 lb] Case material Stainless steel RANGE CODES Range Code Available ranges Range Code Available ranges BN ±50 psid CL ±200 psid BP ±75 psid CP ±300 psid BR ±100 psid CR ±500 psid CJ ±150 psid CT ±750 psid OPTION CODES Range Code Pressure ranges (psid) Temperature compensation Internal amplifiers Internal amp enhancements Many range/option combinations are available in our quick-ship and fast-track manufacture programs. Please see http://sensing.honeywell.com/ TMsensor-ship for updated listings. 50, 75, 100, 150, 200, 300, 500, 750 1a. 60 F to 160 F 1b. 30 F to 130 F 1c. 0 F to 185 F 1d. -20 F to 130 F 1e. -20 F to 200 F 1f. 70 F to 250 F 2b. 4 wire ±5 Vdc 2c. 0 Vdc to 5 Vdc 2j. 4 ma to 20 ma (3-wire) output 2k. 4 ma to 20 ma (two-wire) output 1g. 70 F to 325 F 1h. 70 F to 400 F 1i. -65 F to 250 F 1j. 0 C to 50 C 1m. -25 C to 110 C 2n. (2N) 4 ma to 20 ma (two-wire) intrinsically safe 2t. 0 Vdc to 10 Vdc 2u. Unamplified, mv/v output 3a. Input/output isolation 8 3d. Remote buffered shunt calibration Pressure ports 5 5h. 1/8-27 NPT female (2) 5c. 7/16-20 UNF female Electrical termination Shunt calibration Special calibration Wetted diaphragm 6a. Bendix PTIH-10-6P (or equiv.) 6 pin (max. 250 F) 6b. MS type connector 1 6e. Integral cable: Teflon (-54 C to 245 C) 6f. Integral cable: PVC (-30 C to 70 C) 6g. Integral cable: Neoprene (-20 C to 80 C) 1 8a. Precision internal resistor 7 9a. 10 point (5 up/5 down) 20% increments @ 20 C 9b. 20 point (10 up/10 down) 10% increments @ 20 C 17-4 PH Stainless steel 10a. 316 stainless steel Bridge type 11a. Square bridge 6 11b. Symmetrical bridge 6 11c. Square & symmetrical bridge 6 Zero & span adjustment 14a. No access to pots 14b. Top access to pots 6 Interfaces 53e. Signature calibration 6 53t. TEDS IEEE 1451.4 module 9 6h. Integral cable: Silicone (-54 C to 150 C) 6i. Integral underwater cable (8m [26 ft]) (max. 80 C) 1 6j. 1/2-14 conduit fitting with 1,5 m [5 ft] of 4 conductor PVC cable

Z, Datenblatt Seite 3 Mid Range Wet/Wet Differential Pressure Transducer INTERNAL AMPLIFIERS Amplifier specifications Voltage output: Option 2b Voltage output: Option 2c Output signal ±5 V 0 V to 5 V or ±5 V @ 5 ma Voltage output: Option 2t 0 V to 10 V or ±10 V @ 5 ma Current three-wire: Option 2j Current two-wire: Option 2k Intrinsically safe amp: Option 2n (2N)*** 4 ma to 20 ma 4 ma to 20 ma 4 ma to 20 ma Input power (voltage) ±15 V or 26 Vdc 11 Vdc to 28 Vdc 15 Vdc to 28 Vdc 22 Vdc to 32 Vdc 9 Vdc to 32 Vdc 9 Vdc to 28 Vdc to 32 Vdc Input power (current) 45 ma 40 ma 40 ma 65 ma 4 ma to 28 ma 4 ma to 24 ma Freq. resp (amp) 3000 Hz 3000 Hz 3000 Hz 2500 Hz 300 Hz 2000 Hz Power supply rej. 60 db 60 db 60 db 60 db 60 db 60 db Operating temp. -20 F to 185 F -20 F to 185 F -20 F to 185 F 0 F to 185 F 0 F to 185 F -20 F to 185 F Reverse voltage Yes Yes Yes Yes Yes Yes protection Short cir. protection Momentary Momentary Momentary Yes Yes Yes Wiring code: connector (std) 2 B Output common C Supply return Bl Output common G Supply return C Supply return ** C Supply return** C Supply return** B No connection C No connection E Case ground F No connection B No connection C No connection E Case ground F No connection Bl (+) Output W Case ground Wiring code: cable 2,3,4 Bl (+) Output W Case ground * Black and green wires are internally connected. ** Pins B and C are internally connected. *** See Honeywell s Web site for the most up-to-date information regarding Intrinsically safe approvals, ref #008-0547-00. WIRING CODES Connector Unamplified A, B (+) excitation C, D (-) excitation E (-) output F (+) output TYPICAL SYSTEM DIAGRAM MOUNTING DIMENSIONS AND CHARACTERISTICS

Z, Datenblatt Seite 4 Model Z Mid Range Wet/Wet Differential Pressure Transducer NOTES 1. Availability varies according to range. 2. Interconnecting shunt cal. 1 terminal with shunt cal. 2 terminal provides 50% (unamplified units), 75% (4 ma to 20 ma 3-wire units) or 80% (voltage amplified units of full scale output for quick calibration. Shunt calibration comes standard with internal amplifier options 2b, 2c, 2t and 2j.) 3. O=Orange, Y=Yellow, B=Blue, Bl=Black, R=Red, Br=Brown, W=White, G=Green. Color specifying cable and number or letter specifying connector. 4. No mating connector necessary for cable option. 5. Some pressure port options may require axial orientation. 6. Only available with unamplified option 2u. 7. Only available with amplified options. 8. Only available with Vdc output options 2b, 2c. 9. Consult factory for TEDS availability with amplified models. 10. Range dependent; consult factory. Termination dependent; consult factory. 11. Internal amp and termination dependent; consult factory. 12 5000 ohm bridge required. Note: Unless otherwise specified on order, amplified units with 4 ma to 20 ma output will provide 4 ma at 0 psid and 20 ma at positive full scale and the unit will not operate in the negative direction. An available is to specify 4 ma at negative full scale and 20 ma at positive alternative/full scale. All amps add 2 in to housing. Warranty. Honeywell warrants goods of its manufacture as being free of defective materials and faulty workmanship. Honeywell s standard product warranty applies unless agreed to otherwise by Honeywell in writing; please refer to your order acknowledgement or consult your local sales office for specific warranty details. If warranted goods are returned to Honeywell during the period of coverage, Honeywell will repair or replace, at its option, without charge those items it finds defective. The foregoing is buyer s sole remedy and is in lieu of all warranties, expressed or implied, including those of merchantability and fitness for a particular purpose. In no event shall Honeywell be liable for consequential, special, or indirect damages. While we provide application assistance personally, through our literature and the Honeywell web site, it is up to the customer to determine the suitability of the product in the application. Specifications may change without notice. The information we supply is believed to be accurate and reliable as of this printing. However, we assume no responsibility for its use. WARNING PERSONAL INJURY DO NOT USE these products as safety or emergency stop devices or in any other application where failure of the product could result in personal injury. Failure to comply with these instructions could result in death or serious injury. WARNING MISUSE OF DOCUMENTATION The information presented in this catalogue is for reference only. DO NOT USE this document as product installation information. Complete installation, operation and maintenance information is provided in the instructions supplied with each product. Failure to comply with these instructions could result in death or serious injury. 008721-1-EN IL50 GLO May 2008 Copyright 2008 Honeywell International Inc. All rights reserved. ALTHEN GmbH Meß- und Sensortechnik Frankfurter Straße 150-152 65779 Kelkheim Tel.: +49 (0) 61 95-70 06 0 Fax: +49 (0) 61 95-70 06 66 info@althen.de althen.de ALTHEN GmbH 2014