Power Factor and Power Factor Correction

Similar documents
Fundamentals of AC Power Measurements

CHAPTER 5 POWER QUALITY IMPROVEMENT BY USING POWER ACTIVE FILTERS

ARE HARMONICS STILL A PROBLEM IN DATA CENTERS? by Mohammad Al Rawashdeh, Lead Consultant, Data Center Engineering Services

POWER FACTOR CORRECTION USING BOOST CONVERTER

DSP-BASED CURRENT SHARING OF AVERAGE CURRENT CONTROLLED TWO-CELL INTERLEAVED BOOST POWER FACTOR CORRECTION CONVERTER

Technical Report. Zero Reactive Power Passive Current Harmonic Filter (ZRPPCHF) (In House Case Study) Prepared by. Dr. V. R. Kanetkar.

Contents. Core information about Unit

CHAPTER 6 UNIT VECTOR GENERATION FOR DETECTING VOLTAGE ANGLE

CHAPTER 4 HARMONICS AND POWER FACTOR

POWER FACTOR CORRECTION AND HARMONIC CURRENT REDUCTION IN DUAL FEEDBACK PWM CONTROLLED AC/DC DRIVES.

R. W. Erickson. Department of Electrical, Computer, and Energy Engineering University of Colorado, Boulder

Three Phase PFC and Harmonic Mitigation Using Buck Boost Converter Topology

Improve Power Factor and Reduce the Harmonics Distortion of the System

Power Factor Pre-regulator Using Constant Tolerance Band Control Scheme

Converters with Power Factor Correction

Power Conditioning Equipment for Improvement of Power Quality in Distribution Systems M. Weinhold R. Zurowski T. Mangold L. Voss

Design and Simulation of PFC Circuit for AC/DC Converter Based on PWM Boost Regulator

Electrical Theory. Power Principles and Phase Angle. PJM State & Member Training Dept. PJM /22/2018

Active Power Factor Correction Verification Measurements with an Oscilloscope APPLICATION NOTE

AC Power Instructor Notes

Power Factor improved by Variable Speed AC Drives By Mauri Peltola, ABB Oy, Drives

POWER FACTOR CORRECTION AND ITS PITFALLS

Understanding Power Quality

UNDERSTANDING POWER FACTOR

Chapter 7. Copyright The McGraw-Hill Companies, Inc. Permission required for reproduction or display.

Electrical Motor Power Measurement & Analysis

IMPROVING POWER QUALITY AND ENHANCING THE LIFE OF POWER EQUIPMENT, IN RAILWAY TSSs

3/29/2012 MAIN TOPICS DISCUSSED ELECTRICAL SYSTEMS AND ELECTRIC ENERGY MANAGEMENT SECTION K ELECTRIC RATES POWER COMPUTATION FORMULAS.

Power Quality in Metering

Harmonics White Paper

Welcome to the rd. Annual Northern Ohio. 3 rd Energy Management Conference September 30, 2008

ECE 2006 University of Minnesota Duluth Lab 11. AC Circuits

CHAPTER 2. Basic Concepts, Three-Phase Review, and Per Unit

Efficiency Standards for External Power Supplies IV V

ECET Modern Power

Understanding Harmonics

Study of Power Factor Correction in Single Phase AC-DC Converter

A Single Phase Power Factor Correction Using Programmable Interface Circuit

World Academy of Science, Engineering and Technology International Journal of Electrical and Computer Engineering Vol:7, No:6, 2013

A Single Phase Single Stage AC/DC Converter with High Input Power Factor and Tight Output Voltage Regulation

Power. Power is the rate of using energy in joules per second 1 joule per second Is 1 Watt

Simulation & Hardware Implementation of APFC Meter to Boost Up Power Factor Maintain by Industry.

University of Pennsylvania Department of Electrical and Systems Engineering. ESE 206: Electrical Circuits and Systems II - Lab

Efficiency Standards for External Power Supplies IV V

Design and Simulation of Passive Filter

2.0 AC CIRCUITS 2.1 AC VOLTAGE AND CURRENT CALCULATIONS. ECE 4501 Power Systems Laboratory Manual Rev OBJECTIVE

Single Phase Bridgeless SEPIC Converter with High Power Factor

Section 11: Power Quality Considerations Bill Brown, P.E., Square D Engineering Services

CHAPTER 4 PV-UPQC BASED HARMONICS REDUCTION IN POWER DISTRIBUTION SYSTEMS

22.0 Harmonics in Industrial Power Systems

How adjustable speed drives affect power distribution

What does Power Factor mean?

PQ for Industrial Benchmarking with various methods to improve. Tushar Mogre.

Testing Power Factor Correction Circuits For Stability

Tuningintobetter power quality

Analog and Digital Circuit Implementation for Input Power Factor Correction of Buck Converter in. Single Phase AC-DC Circuit

Power Quality Monitoring and Power Metering Tutorial

Sizing Generators for Leading Power Factor

Improving the Power Factor of Isolated Flyback Converters for Residential ENERGY STAR LED Luminaire Power Supplies

AC Drives and Soft Starter Application Guide

Increasing the Performance of PFC and LED Driver Applications

Power Factor Correction Input Circuit

Power Measurements for Switch-Mode Power Supplies SAVE Verona 2011

Thyristorised Automatic Power Factor

Literature Review for Shunt Active Power Filters

1C.4.1 Harmonic Distortion

HARMONICS CAUSES AND EFFECTS

Minimizing Input Filter Requirements In Military Power Supply Designs

Power Factor. Power Factor Correction.

CHAPTER 3 IMPROVEMENT OF LOAD POWER FACTOR USING FACTS CONTROLLERS

Power Quality Improvement for Fluorescent Lighting

Reactive power compensation for linear and non linear loads by using active and passive filter for smart grid applications.

Laboratory no. 3 FLUORESCENT LAMPS FITTINGS

Harmonic Solutions. Clean Power Drive Solution to Harmonic Distortion

A NEW SINGLE STAGE THREE LEVEL ISOLATED PFC CONVERTER FOR LOW POWER APPLICATIONS

Lab 4 Power Factor Correction

+ 24V 3.3K - 1.5M. figure 01

Question Paper Profile

International Journal of Scientific & Engineering Research, Volume 6, Issue 10, October ISSN

OPTIMAL DESIGN OF A SINGLE TUNED PASSIVE FILTER TO MITIGATE HARMONICS IN POWER FREQUENCY

Technical News. Part 2: Harmonics. The link between harmonics and power factor. Industrial Electrical and Automation Products, Systems and Solutions

OVERVIEW OF SVC AND STATCOM FOR INSTANTANEOUS POWER CONTROL AND POWER FACTOR IMPROVEMENT

Harmonic Filters and Reactors

Multimeter 500CVD21 RTU500 series

Today most of engineers use oscilloscope as the preferred measurement tool of choice when it comes to debugging and analyzing switching power

ZIZTEL LIMITED web: tel: +44 (0) mail: 96 Rolleston Drive, Arnold, Nottingham, NG5 7JP United

PRUDENT PRACTICES TO IMPROVE POWER FACTOR AND REDUCE POWER LOSS.

ISSN: ISO 9001:2008 Certified International Journal of Engineering Science and Innovative Technology (IJESIT) Volume 2, Issue 3, May 2013

Enhancement of Power Quality Using Advanced Series Active Power Filters

New Techniques for Testing Power Factor Correction Circuits

Current Rebuilding Concept Applied to Boost CCM for PF Correction

Unit 3 Magnetism...21 Introduction The Natural Magnet Magnetic Polarities Magnetic Compass...21

Understanding Input Harmonics and Techniques to Mitigate Them

Increasing the Performance of PFC and LED Driver Applications

3rd-Gen. Critical Mode PFC Control IC FA1A00 Series

IMPORTANCE OF VSC IN HVDC

AC Sources for IEC 1000 Harmonics and Flicker Testing

Webpage: Volume 3, Issue IV, April 2015 ISSN

Preface...x Chapter 1 Electrical Fundamentals

Harmonic Requirements

Transcription:

Power Factor and Power Factor Correction

Long gone are the days when only engineers that worked with large electric motors and high power electric loads need worry about power factor. The introduction of switching power supplies into electronic systems has led to increasing international legislation, moving power factor up the list as a key concern for most engineers developing systems that run on ac mains power. WHAT IS POWER FACTOR? DEFINING POWER FACTOR Power factor (pf) is the ratio of real power (P) flowing to the load, to the apparent power in the circuit (S). It is a sinusoidal waveform and therefore expressed as dimensionless number between -1 and 1: pf = P/S For a purely resistive load, the two figures are identical; for a reactive load the arithmetic for the apparent power produces the same figure, that is, the product of the RMS values of voltage and current. However, to find the actual (real) power delivered to the load, the instantaneous product of voltage and current must be integrated over the complete sine-wave cycle. ADDING REACTIVE POWER INTO THE EQUATION Real (or active) power, measured in watts (W), is defined as the circuit s capacity to perform work at a given time. Apparent power, measured in volt amperes (VA), is the product of the current and voltage of the circuit. When current is leading or lagging voltage, the value of that integral will always be less than the value for the in-phase case over the same interval. This reflects the attribute of an inductor or a capacitor to act as energy stores; at various points through the ac cycle the reactive component (Q) is either storing energy, or returning it to the system. Perfectly sinusoidal waveforms follow Pythagoras, where the square of the apparent power is equal to the squares of the active power and reactive power measured in reactive volt amperes (var): S 2 = P 2 + Q 2 or P = S cos θ CURRENT VOLTAGE POWER AVERAGE POWER Figure 1: Instantaneous and average power calculated from ac voltage and current with a zero power factor. page 2

The relationship is conventionally visualized in a right-angled triangle vector diagram; P (watts) θ Q (var) S (VA) CURRENT VOLTAGE POWER AVERAGE POWER Figure 2: Right angled triangle vector diagram Apparent power is always greater than or equal to real power and a negative power factor can occur when the device starts to generate power that then flows back to the generator. IDEAL VS. REAL WORLD Ideal power factor occurs when the current and voltage waveforms are in phase: pf = 1 (i.e. cos 0) When the power factor is not equal to 1.0, power losses, and potentially harmonics that disrupt other devices, occur. Once again, this basic definition is for pure sinusoids. Non-sinusoidal waveforms are more complex, but as they can be represented by a series of harmonic sinusoids, the same basic principles apply. Problems occur, however, when a non-linear load on a power system, typically in the form of a power supply, create current harmonics not present in the voltage; in effect, these current harmonics become part of the reactive power. They do not represent true power delivered to the load, thus degrading the power factor. Figure 3: Instantaneous and average power calculated from ac voltage and current with a lagging power factor of 0.71 THE NEED FOR POWER FACTOR CORRECTION IMPORTANCE OF POWER FACTOR AND POWER FACTOR CORRECTION Power factor is on the list of design concerns for designers of virtually every device that draws significant power from a mains socket, as well as for engineers in heavy-electrical sectors. Not only are there principles of good engineering practice at stake, there is also legislation to enforce conformance with power-factor norms. LEGISLATION The first attempt to legislate for ac mains power interference came over 100 years ago (1899), to prevent incandescent lamps from flickering, but one of the key regulations came in 1978, with IEC 555-2 requiring power factor correction be incorporated into consumer products. page 3

THE NEED FOR POWER FACTOR CORRECTION Power factor is on the list of concerns for designers of virtually every device that draws significant power from a mains socket, as well as for engineers in heavy-electrical sectors. Not only are there principles of good engineering practice at stake, there is also legislation to enforce conformance with power-factor norms. LEGISLATION HISTORY The first attempt to legislate for ac mains power interference came over 100 years ago to prevent incandescent lamps from flickering. IEC 555-2 was the key regulation which required power factor correction to be incorporated into consumer products. All electronic equipment in the EU connected to public mains up to and including 16 A max rated input must comply with EN 61000-3-2 A B C DEVELOPING REGULATIONS Following Europe s lead, China, Japan and Australia have government regulations for power-line harmonics that have evolved from EN 61000-3-2. European Union ( D ) 75W~600W China Japan EN 61000-3-2 CLASSES The standard is split into four classes: A, B, C for appliances, power tools, and lighting and the most stringent class, D, for PCs, computer monitors, and TVs rated 75~600 W. Australia Today, the U.S. Department of Energy s voluntary Energy Star guidelines call for computing equipment to have a power factor of 0.9 at 100 percent of rated output in the application s power supply, meaning designs with internal power supplies require the use of active power factor correction. Across the Atlantic, the EU legislates the EN 61000-3-2 standard for electronic equipment, setting limits to the 39 th harmonic for equipment with input currents less than or equal to 16 A per phase. The standard is split into four classes: A, B, C for appliances, power tools, and lighting respectively, and the most stringent class, D, for PCs, computer monitors, and TVs rated between 75 and 600 W. Following Europe s lead, a host of countries are developing increasingly stringent legislation. Most notably China, Japan and Australia have government regulations for power-line harmonics that have evolved from EN 61000-3-2. page 4

SUPPLY IMPLICATIONS Why is this cause for concern? Electric utilities and generating bodies require their customers to present a load to the power grid that is as nearly unity power-factor as possible. The main, but not the only reason, is fiscal. The customer expects to pay for the real work done on his premises in other words, the value of W, above. But a PF of less than 1.0 means that the VA value must be higher than W. The generators and transmission companies must provision to deliver the peak voltage and current values in the waveform at any time. A power factor of less than 1.0 is effectively an increase in their costs, and one that they pass back to customers by imposing an increased tariff for customers with low power-factor loads. Achieving maximum power factor is therefore a win-win for all concerned. ENGINEERING PROBLEMS OF LOW PF There are further effects that power utilities must contend with, that makes a unity-power-factor load highly preferable. Rotating plant-generated power is more difficult to manage and to keep stable when supplying a low power factor, and there can be heating or overload hazards for transformers and transmission equipment in the supply grid. Grid stability is also more difficult to maintain with low-power-factor loads attached to the system. Low power factor also tends to be associated with other negative attributes for a well-behaved electrical load. Highly-distorted current waveforms drawn from the mains can inject high-order harmonics back into the supply grid. Transmission equipment has higher losses at higher frequencies leading to heating problems, and, if the higher frequencies are present in the load placed directly on the generating plant, they can manifest themselves as destructive vibrations leading to excessive wear on components such as bearings. Current distortion can lead to out-of-balance currents in the neutral lines of 3-phase distribution networks, which in turn can take the neutral away from ground (voltage) and give rise to multiplicity of problems. POOR CURRENT WAVEFORMS, AND HARMONIC EFFECTS Waveform distortion is not, strictly, the same phenomenon as power factor but because of the close connection between the two (as noted above, current harmonics degrade PF), they are governed by the same standards that place limits on the load that may be drawn by mains-supplied equipment; for example EN 60555 in Europe, and IEC 555-2 internationally. POWER SUPPLIES FOR ELECTRONIC SYSTEMS Even when most electronic equipment was supplied by power supplies that used linear regulation, power factor (and waveform distortion) was often less than ideal, but was rarely addressed for anything other than the largest supplies. The typical, conventional off-line arrangement was that of a transformer followed by a bridge rectifier, feeding a reservoir capacitor. Conduction through the rectifier would take place when the dc voltage on the output line had sagged below the instantaneous value of the transformed ac supply, which could be for the complete cycle at full load, or only at the peak of the ac waveform under light load. SWITCHING POWER SUPPLIES Switching power supplies can significantly worsen the situation. The off-line part of the design may not change, still comprising a transformer/rectifier, and capacitor, but now one or more switching regulators have been added to the equation. The input rectifier continues to generate poorly-shaped current waveforms with the added challenge that some of the higher-frequency switching noise from the regulation stage can find its way back into current drawn from the wall socket. page 5

PHASE AND HARMONIC EFFECTS Not only does this shift the effective current peak away from that of the voltage waveform in time, it also introduces high-harmonic-content switching waveforms that potentially worsen the distortion of the current waveform. The arrival of this class of supply broadly coincided with the widespread deployment of PCs and other IT products in great numbers. Such trends led directly to today s legislative environment. METHODS FOR POWER FACTOR CORRECTION PASSIVE VS ACTIVE POWER FACTOR CORRECTION The solution to excess harmonics is to use power factor correction (PFC), which shapes the input current of the power supply to maximize the real power level from the mains and minimize harmonic distortion. Ideally, the electrical appliance should present a load that resembles a linear load, such as a simple resistor, rather than the reactive load of an uncorrected switching power supply. This corrected waveform minimizes losses as well as interference with other devices being powered from the same source. Compensation for low power factor can be by passive or active devices. The simplest case is that of improving the power factor presented by electric motors. Naturally, being wound machines, they are highly inductive loads, and adding capacitors to the supply network has long been standard practice. Even this case may not be entirely simple; the designer of such a network has to take care not to create unwanted resonant effects, for example. Variable power factor in the load may be accommodated by an adaptive scheme to connect reactive elements as required and in high-power contexts (MW scale) rotating-machinery solutions can be applied. Power supply designers must subject to their designs falling into specific power rating bands take into account regulatory constraints, but they are invariably also under pressure to meet space, component bill-of-materials and efficiency targets. Apparent Power Real Power=100kW S Before=167kVA After=105kVA POWER FACTOR CALCULATIONS Before PF 100/167= 60% After PF 100/105= 95% Figure 4: Effect of power factor correction Q= Before, 134kvar Reactive Power After= 32kvar Capacitance Added= 102kvar page 6

PASSIVE POWER FACTOR CORRECTION Passive power factor correction in the form of filtering can be effective, within limits, and has the effect of reducing the higher-order current harmonics that, as noted above, contribute to degraded power factor. Such techniques involve putting a low-pass filter in the input side of the power supply to suppress higherorder harmonic components, and then compensating lead/lag characteristics as with conventional power factor. The downside to this scheme is that large (both by value, and physically) inductors and/or capacitors may be required. Additionally, there are limitations to the input range and power rating when implementing this scheme; passive PFC circuits are generally able to achieve a power factor in the range of 0.70-0.75. C1 AC in C2 - + C3 C4 PASSIVE PFC CIRCUIT L1 Inductor DC Bus AC in D1 - + ACTIVE PFC CIRCUIT Figure 5: circuit diagrams of passive/active filtering DC Bus ACTIVE POWER FACTOR CORRECTION The existence of, and rapid progress in, high-speed, high-current capacity semiconductor switches the same components that enable the high-efficiency switch-mode supply to be built at all make available the option of active power factor correction which allows for a power factor close to 1.0. PFC Control Mosfet D2 C1 L1 Inductor D3 Because of this, it is the strategy that is most widely applied in present-day designs. A switching preregulator stage is placed in the input current path of the supply. That regulator is designed not only to maintain a constant DC voltage to feed the main converter stage of the power supply, but also to draw current from the input in-phase with the incoming AC voltage waveform. An additional switching stage in the supply does impose some extra losses, and some extra cost. As indicated above, there are compensating savings in the form of smaller passive filtering components, and in the supply s main converter. However, the added pre-regulator introduces a potential source of EMI (electromagnetic interference) noise that must be taken into account in the final design. DESIGN CONSTRAINTS AND MEASUREMENT The design is therefore constrained by a power factor target, which will come from legislation and is nonnegotiable, plus all of the usual factors of efficiency, component cost, and volume/board space occupied. To design to those targets, especially power factor, demands that it can be measured. Simple multimeters will usually misread to some extent when presented with distorted waveforms; a good digital multimeter may make a good effort at reporting the RMS value of even a moderately distorted waveform, but will be challenged to record power factor. An oscilloscope with current and waveform probes can be used to gauge the phaseshift (of the angle Ɵ, as above) but only if the voltage and current wave-shapes are reasonably similar. Electrical engineering has traditionally used precision electromechanical (moving coil) meters that directly measure power factor, but these are hardly suitable to track down the effects of khz or MHz regulator switching in an advanced PSU. page 7

A small number of test & measurement suppliers offer power analyzers; by rapidly sampling current and voltage waveforms and performing a suite of calculations and applying a Fourier transform to extract harmonic information every detail of a load s performance in terms of distortion and power factor are revealed. SUMMARY Power factor is on the list of concerns for designers of virtually every device that draws significant power from a mains socket, as well as for engineers in heavyelectrical sectors. The power factor target, based on legislation, plus efficiency, component cost, and volume/board space need to be considered. For this reason CUI has designed active power factor correction into the vast majority of its ac-dc power supplies rated at 100W and above to help ease implementation and ensure compliance for OEMs. www.cui.com 20050 SW 112 th Ave. Tualatin, Oregon 97062 page 8 CUI Inc 2013. All rights reserved. 06/2013