Single Output Power Supply AK-000 series Features : Universal AC input with active PFC Programmable output Voltage ( 0% ~ 0% ) Programmable output Current ( % ~ 0% ) High efficiency up to % +V / 0.A auxiliary output U profile, High power density 0.8w / in Forced current sharing at parallel operation Power OK signal ( Power good, Logic low) Remote ON-OFF, Remote sense function Protections : OVP, OLP, OTP, SCP, Fan failure years warranty Output Input Protection Function Envionmenrt Safety & EMC Note. Other Note MODEL DC Voltage Range Rated Current Current Range Rated Power Ripple & Noise (Max.) Voltage Adj. Range Voltage Tolerance Line Regulation Load Regulation Setup, Rise Time Hold Up Time (Typ.) Voltage Range Frequency Range Power Factor (Typ.) Efficiency (Typ.) AC Current (Typ.) Inrush Current (Typ.) Leakage Current Over Load Over Voltage Over Temperature Auxiliary Power Remote ON/OFF Control Power OK Signal Output Voltage Trim Output Current Trim Parallel (Current Sharing) Working Temp. Working Humidity Storage Temp., Humidity Temp. Coefficient Vibration Safety Standards Withstand Voltage Isolation Resistance EMI Conduction & Radiation Harmonic Current EMS Immunity Cooling Dimension (L*W*H) Packing AK-000- V V V A 00A A 0 ~ A 0 ~ 00A 0 ~ A Note. mvp-p mvp-p mvp-p ±.0% Typical adjustment by potentiometer (VR) Note. ±.0% ±0.% ±0.% 0ms, 00ms at full load 0ms / 0VAC at full load Note. ~ VAC 7 ~ VDC 7 ~ Hz Note. EN000-- (0.98 / 0VAC, 0.99 / VAC at full load) 87% A/VAC A/VAC <.ma / VAC 8A / 0VAC A / 0VAC AK-000- AK-000-0 % ~ 0% rated output power Protection type : Constant current limiting, Latch-style (Recovery after reset AC power ON or inhibit) Variable OVP, 0% ± % Vout. Protection type: Latch-style (Recovery after reset AC power ON or inhibit) 8 C± C Protection type: Shut down o/p voltage (Auto recovers after temperature goes down) V@0.A(+/-%) External switch or NPN Transistor to turn ON / OFF Open drain signal low when PSU turns on, Max. sink current: 0mA, Max. drain voltage: V. Adjustment of output voltage is between 0 ~ 0% of rated output Adjustment of output current is between ~ 0% of rated output Please refer to function - ~ +0 C (Refer to output load de-rating curve) 0 ~ % R.H non-condensing -~+8 C, 0 ~9% R.H ±0.0%/ C (0 ~ C) Compliance to IEC 8--, IEC 8-- nd UL 09-, Edition, TUV EN09- : 00+A Approved I/P-O/P: KVAC I/P-FG:.KVAC O/P-FG: 0.KVAC I/P-O/P, I/P-FG, O/P-FG: 00MΩ / 0VDC EN: 00 Class A EN000--: 00 Class B, EN000--: 99+A: 00+A: 00 EN0-: 000, EN: 998+A: 00+A: 00 light industry level, criteria A Controlled by power rating & temperature (Internal ball bearing fan) 0x7x7 mm /.0x.0x.0 inch.kg ; Pcs /.8kg / 0. CUFT AK-000-7 7V A 0~A mvp-p 88% 89% 89% % AK-000-8 8V.A 0 ~.A mvp-p.all parameters NOT specially mentioned are measured at 0VAC input, rated load and C of ambient temperature..ripple & noise are measured at 0MHz of bandwidth by using a " twisted pair-wire terminated with a 0.uf & 7 uf parallel capacitor..tolerance: includes set up tolerance, line regulation and load regulation..de-rating may be needed under low input voltages. Please check the de-rating curve for more details..in parallel connection, maybe only one unit operate if the total output load is less than % of rated load condition..the power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. 0/08/0
Single Output Power Supply AK-000 series Unit:mm/inch Mechanical Specification 0 9 8 7 Airflow direction AC Input Terminal ACL ACN Control pin number assignment VO+ VS+ VS- VO- 7 8 9 0 P.OK VCI ACI PAR Function Description 7 8 9 0 Function VO+ VS+ VS- VO- P.OK VCI ACI PAR Description Local output voltage sense (+) Remote voltage sense (+) Remote voltage sense ( ) Local output voltage sense ( ) +V / 0.AAuxiliary power Inhibit ON/OFF (+) Inhibit ON/OFF ( ) Ground Power OK V Program I Program Parallel operation current share 0/08/0
Single Output Power Supply AK-000 series De-rating Curve Load V.S Temp. Load V.S I/P Voltage Ta= C 00 @>0VAC 00 Load (%) @00VAC Load (%) 0 0-0 0 0 0 0 Ambient Temperature ( C) 00 0 0 0 0 Input Voltage (Vac) Function Manual. Output Voltage Trim 0 00 00 Output Voltage (%) 0 Output Voltage (%) 8 0 0...0..0..0..8 Extemal Voltage (VDC). 8. 9 7 000 0 Open Extemal Resistor (K Ω) VO+ VS+ VS- VO- VO+ VS+ VS- VO- 7 P.OK VCI ACI- PAR 7 P.OK VCI ACI- PAR 0/08/0
Single Output Power Supply AK-000 series. Output Current Trim Output Current (%) 0 00 0 Output Current (%) 00 0..0..0..0...0 Extemal Voltage (VDC). 0 00 Open Extemal Resistor (K Ω) VO+ VS+ VS- VO- VO+ VS+ VS- VO- 7 P.OK VCI ACI- PAR 7 P.OK VCI ACI- PAR (A). Remote ON/OFF (B) (C) KΩ KΩ KΩ SW (A) Using internal V auxiliary source (B) ON / OFF Control by NPN transistor (C) Using external voltage source. Power OK Signal DC/DC V/0.A *Place an additional capacitor to have a better performance of auxiliary power operation. * The grounding of "" power should be connected to "" port. If " V-" is connected as Grounding, make sure to short the and V- ports. * μ F 0V. LOAD 0/08/0
Single Output Power Supply AK-000 series Installation Instruction. Mounting Directions - Recommended standard mounting methods: (a) (b) -M L=mm max. -M L=mm max.. Mounting Method - There are ventilating holes on the front and back side panels, do not obstruct; allow mm at least for air flow. - The Maximum allowable penetration of screw is mm. Incomplete threading should not be penetrated. - Recommended the torque of mounting screw: M screw:.7n m (.0kgf cm) More than mm More than mm FAN Air flow 0/08/0