Keysight Technologies Performing Impedance Analysis with the E5061B ENA Vector Network Analyzer. Application Note

Similar documents
Keysight Technologies Power of Impedance Analyzer

Keysight Technologies Using a Network and Impedance Analyzer to Evaluate MHz RFID Tags and Readers/Writers

Keysight E5061B-3L3/3L4/3L5 LF-RF Network Analyzer with Option 005 Impedance Analysis Function. Data Sheet

Keysight Technologies Network Analyzer Measurements: Filter and Amplifier Examples. Application Note

Agilent E5061B Network Analyzer. 100 khz to 1.5 GHz/3 GHz 5 Hz to 3 GHz

Keysight Technologies Differences in Application Between Power Dividers and Power Splitters. Application Note

Keysight E5063A ENA Series Network Analyzer

Keysight Technologies Direct Power MOSFET Capacitance Measurement at 3000 V

Keysight Technologies N9398C/F/G and N9399C/F DC Block. Technical Overview

Keysight Technologies

Introduction. Part 1. Introduction...2

Keysight Technologies Improving the Test Efficiency of MEMS Capacitive Sensors Using the E4980A Precision LCR Meter.

Keysight Technologies Measuring Group Delay of Frequency Converters with Embedded Local Oscillators. Application Note

Keysight Technologies Improving Test Efficiency of MEMS Electrostatic Actuators Using the E4980A Precision LCR Meter.

Keysight Technologies MEMS On-wafer Evaluation in Mass Production

Keysight Technologies N9310A RF Signal Generator

Keysight Technologies 8490G Coaxial Attenuators. Technical Overview

Keysight Technologies Migrating Balanced Measurements from the

Keysight Technologies, Inc. UWB Antenna Measurements with the 20 GHz E5071C ENA Network Analyzer. Application Note

Keysight Technologies P9400A/C Solid State PIN Diode Transfer Switches

Keysight Technologies Accurate Capacitance Characterization at the Wafer Level

Keysight Technologies Electronic Calibration (ECal) Modules for Vector Network Analyzers

Keysight DSOXT3FRA/DSOX4FRA/DSOX6FRA Frequency Response Analyzer (FRA) Option

Keysight Technologies Simultaneous Measurements with a Digital Multimeter

Keysight Technologies Measuring Low Current Consumption with a Digital Multimeter

Keysight Technologies 423B, 8470B, 8472B, 8473B/C Low Barrier Schottky Diode Detectors

Keysight Technologies RF & Microwave Attenuators. Performance you can count on

Keysight M9485A PXIe Multiport Vector Network Analyzer

Keysight E5063A ENA Vector Network Analyzer

Keysight Technologies N4985A System Amplifiers

Keysight 8474B/C/E Planar-Doped Barrier Diode Detectors 0.01 to 50 GHz. Data Sheet

Keysight Measuring High Impedance Sources Using the U8903B Audio Analyzer. Application Note

Keysight Technologies

Keysight Technologies Active Differential Probes U1818A 100 khz to 7 GHz U1818B 100 khz to 12 GHz. Technical Overview

Keysight Technologies Accurate Evaluation of MEMS Piezoelectric Sensors and Actuators Using the E4990A Impedance Analyzer.

Keysight N9311X RF and Microwave Accessory Kit for Low-cost Handheld and Benchtop Solutions. Technical Overview

Keysight Technologies USB Preamplifiers

Keysight HMMC-1002 DC 50 GHz Variable Attenuator

Keysight Technologies N2792A/N2818A 200 MHz and N2793A/N2819A 800 MHz Differential Probes. Data Sheet

Introduction. Part 1. Introduction...2

Keysight Technologies 87405C 100 MHz to 18 GHz Preamplifier. Technical Overview

Keysight Technologies Precise Low Resistance Measurements Using the B2961A and 34420A

Keysight Technologies Accurate NBTI Characterization Using Timing-on-the-fly Sampling Mode. Application Note

Keysight Technologies 1 mw 50 MHz Power Reference Measurement with the N432A Thermistor Power Meter. Application Note

Keysight Technologies Migrating from the 4268A/4288A Capacitance Meter to the E4981A Capacitance Meter. Technical Overview

Keysight Technologies Making Simpler DC Power Measurements with a Digital Multimeter

Keysight Technologies Making Field Effect Transistor Characterization Using SMU

Keysight Technologies Solid State Switches. Application Note

Keysight M940xA PXIe Optical Extenders for Instrumentation. Data Sheet

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment

Keysight Technologies N4983A Multiplexer and Demultiplexer. Data Sheet

Keysight Technologies Optimizing RF and Microwave Spectrum Analyzer Dynamic Range. Application Note

Keysight Technologies N9398C/F/G and N9399C/F DC Block. Technical Overview

Keysight Technologies NFA Noise Figure Analyzer. Configuration Guide

Keysight Technologies E4980A Precision LCR Meter


Keysight Technologies Waveguide Power Sensors. Data Sheet

Keysight Technologies N6850A Broadband Omnidirectional Antenna. Data Sheet

Keysight Technologies Phase Noise X-Series Measurement Application

Keysight Technologies Making Current-Voltage Measurement Using SMU

Keysight Technologies Measuring Dielectric Properties Using Keysight s Materials Measurement Solutions

Keysight Technologies Optimizing VNA Settings for Testing of LTE-A Wireless Components. Application Note

Keysight Technologies HMMC GHz High-Gain Amplifier

Keysight Technologies N1918A Power Analysis Manager and U2000 Series USB Power Sensors. Demo Guide

Keysight Technologies FFT and Pulsed RF Measurements with 3000T X-Series Oscilloscopes. Application Note

Keysight Technologies Measuring Dielectric Properties Using Keysight s Materials Measurement Solutions

Keysight Technologies DSOX3PWR/DSOX4PWR/DSOX6PWR Power Measurement Options

Keysight Technologies PXI Vector Network Analyzer Series. Drive down the size of test

Keysight Redefines 50 GHz Portability. Get a $30k Credit When You Move Up to FieldFox

Keysight Technologies Achieving Accurate E-band Power Measurements with E8486A Waveguide Power Sensors. Application Note

Keysight Technologies Split Post Dielectric Resonators for Dielectric Measurements of Substrates. Application Note

Keysight Technologies Wide Range DC Current Biased Inductance Measurement

Keysight Technologies Automated Receiver Sensitivity Measurements Using U8903B. Application Note

Keysight Technologies High Frequency Probing Solutions for Time and Frequency Domain Applications. Application Note

Keysight Technologies N2750A/51A/52A InfiniiMode Differential Active Probes. Data Sheet

Keysight E5061B-3L3/3L4/3L5 LF-RF Network Analyzer with Option 005 Impedance Analysis Function

Keysight Technologies Using an External Trigger to Generate Pulses with the B2960A

Keysight Technologies Precise Current Profile Measurements of Bluetooth Low Energy Devices using the CX3300. Application Brief

Keysight Technologies, Inc. Overcome PCB Loss and Deliver a Clean Eye to Your DUT Using Multi-tap De-emphasis

Keysight Technologies Enhance EMC Testing with Digital IF. Application Note

Keysight U1882B Measurement Application for Infiniium Oscilloscopes. Data Sheet

Keysight Technologies

The Keysight Technologies, Inc. U1730C Series handheld LCR meters allow you to measure at frequencies as high as 100 khz a capability typically found

Keysight Technologies N9063A & W9063A Analog Demodulation

Keysight E5061B Network Analyzer. Configuration Guide

Keysight Technologies A comparison of Keysight Network Analyzers for Applications < 3 GHz. Selection Guide

Keysight Technologies Impedance Measurements

Keysight Technologies 7 Hints That Every Engineer Should Know When Making Power Measurements with Oscilloscopes. Application Note

Keysight Technologies N2790A 100 MHz, N2791A 25 MHz and N2891A 70 MHz High-voltage Differential Probes. Data Sheet

Keysight N9310A RF Signal Generator

Keysight N8836A PAM-4 Measurement Application For Infiniium S-Series, 90000A, V-Series, X-Series, Q-Series, and Z-Series Oscilloscopes

Keysight Technologies U1210 Series Handheld Clamp Meters

Keysight E5063A ENA Vector Network Analyzer. 100 khz to 500 M/1.5 G/3 G/4.5 G/6.5 G/8.5 G/14 G/18 GHz

Keysight Technologies Make Better AC RMS Measurements with Your Digital Multimeter. Application Note

Keysight Technologies U1730C Series Handheld LCR Meters Take your expectations higher with the latest LCR meters. Data Sheet

Keysight Technologies 87405C 100 MHz to 18 GHz Preamplifier. Technical Overview

Keysight N2806A Calibration Pulse Generator The world s fastest differential pulse generator. Data Sheet

Keysight Technologies VSA Software for Simulation Environments BE/89601 BNE

Keysight Technologies E4990A Impedance Analyzer. 20 Hz to 10/20/30/50/120 MHz

Keysight E5063A ENA Series PCB Analyzer

Transcription:

Keysight Technologies Performing Impedance Analysis with the E5061B ENA Vector Network Analyzer Application Note

Introduction Whether you need to measure basic S-parameters or analyze device or circuit impedance, a vector network analyzer (VNA) with the right mix of speed and performance will give you an edge. In R&D and on the production line, Keysight ENA vector network analyzers provide the throughput, repeatability and reliability you need to perform accurate, dependable tests that transform parts into competitive components. As impedance analysis capabilities have been built into network analyzers, they are increasingly being used to perform impedance measurements on electronic components and circuits. This is especially true in R&D environments that benefit from the versatility and flexibility of a VNA-based solution. The Keysight E5061B ENA vector network analyzer covers 5 Hz up to 3.0 GHz (Option 3L5), addressing low-frequency (LF) and radio-frequency (RF) measurements. With the impedance analysis capability (Option 005), the E5061B addresses a wide range of LF and RF applications. This application note describes five common impedance analysis approaches used with impedance analyzers and network analyzers. It also describes how and when to use the E5061B for impedance analysis. Major topics include test ports, impedance analysis capabilities, measurement methods, and calibration techniques. The note concludes with a variety of examples ranging from basic component measurements (e.g., inductors and capacitors) to in-circuit impedance measurements. Table of Contents Introduction 02 Performing Impedance Analysis with the E5061B 03 Examining Five Commonly Used Measurement Methods 05 Selecting the Best Method for Your Application 08 Ensuring Accurate Results: Calibration and More 10 Examining Real-world Examples 14 Conclusion 16 Related Information 17

03 Keysight Performing Impedance Analysis with the E5061B ENA Vector Network Analyzer - Application Note Performing Impedance Analysis with the E5061B The E5061B offers versatile network analysis capabilities from 5 Hz to 500 MHz (Option 3L3), 1.5 GHz (Option 3L4) or 3.0 GHz (Option 3L5). Comprehensive LF measurement capabilities such as built-in 1 MΩ inputs are seamlessly integrated with the highperformance network analyzer architecture. Core features include S-parameter test ports (), a gain-phase test port (switchable between and 1 MΩ), and a DC bias source (up to ±40 V dc ). Adding impedance analysis For an E5061B configured with any of the LF-RF network analysis options 3L3, 3L4 or 3L5 ( 3Lx collectively) Option 005 provides impedance analysis (ZA) firmware. The combination of NA and ZA capabilities further enhances the analyzer s versatility as a general-purpose R&D tool. Adding the ZA firmware enables the analyzer to measure impedance parameters of electronic components such as capacitors, inductors, and resonators. Additional functionality includes fixture compensation and equivalent circuit analysis. Biased impedance measurements are possible with the built-in DC bias source provided by options 3L3, 3L4 and 3L5. With any of the frequency options, E5061B-005 cannot match the ultimate overall performance of a dedicated impedance analyzer. However, it does enable you to apply measurement methods, calibration techniques, and fixturing choices that provide comparably accurate impedance measurements. E5061B ENA vector network analyzer As part of the ENA family, the E5061B is designed to help you drive down the cost of test. It addresses a broad range of needs in the characterization of electronic components and circuits in communications, aerospace, defense, computing, medical, automotive, CATV, and more. You can configure the E5061B with a variety of S-parameter and transmission/reflection test sets as well as options for time-domain/fault-location analysis, impedance analysis, and wireless power transfer analysis. www.keysight.com/find/e5061b

04 Keysight Performing Impedance Analysis with the E5061B ENA Vector Network Analyzer - Application Note Comparing the test ports The E5061B-3Lx is equipped with two types of test ports: S-parameter and gain-phase. Let s take a closer look at each type. The S-parameter test ports (Port 1 and 2) have a built-in 50-Ω test set that covers the analyzer s full frequency range (Figure 1). In the RF range, the E5061B provides excellent performance equal to that of similar analyzers. The E5061B particularly excels in the LF range, providing coverage down to 5 Hz and better dynamic range in the low-to-middle range below 10 MHz for thorough evaluation of one- and two-port devices such as filters, amplifiers, transformers, and antennas. T R 5 Hz to 3 GHz ATT Z in ATT Z in R 1 T 1 R 2 T 2 S 11 S 21 S 22 DUT S 12 Figure 1. The right side of this block diagram shows the S-parameter test ports and test set built into the E5061B-3L5. Note the maximum frequency range is 5 Hz to 3 GHz. The gain-phase test port has reference and test receiver inputs with the ability to switch between and 1 MΩ input impedance (Figure 2). These are used to analyze the frequency response of low-frequency devices and circuits such as op-amps and the control-loop circuits of DC-to-DC converters. Z in = 1 MΩ or attenuation = 20 db or 0 db T ATT Z in R ATT Z in 5 Hz to 30 MHz R 1 T 1 R 2 T 2 T R LF out Figure 2. The left side of this block diagram shows the gain-phase ports built into the E5061B-3Lx. Note the frequency range is 5 Hz to 30 MHz in this mode

05 Keysight Performing Impedance Analysis with the E5061B ENA Vector Network Analyzer - Application Note Examining Five Commonly Used Measurement Methods If we step back and survey the capabilities of dedicated impedance analyzers as well as network analyzers with ZA capability, there are five commonly used measurement methods. Impedance analyzers typically use either the auto-balancing bridge or RF current-voltage (I-V) method. In the E5061B, the ZA firmware supports three methods: reflection, series-through and shunt-through. The following section describes each method and applicability to specific applications. Taking a closer look: Impedance analyzer methods The Keysight E4990A impedance analyzer is one an example of a low-frequency instrument (20 Hz to 120 MHz) that employs the auto-balancing bridge method. Figure 3 shows a simplified block diagram of the bridge circuit. In this model, a negative feedback loop maintains a specific potential at the low terminal relative to virtual ground (zero volts). This eliminates stray capacitance and enables the voltmeters, V 1 and V 2, to accurately measure voltage and current with excellent linearity at the device under test (DUT). This method offers the highest accuracy across a very wide range of impedance values. Figure 3. The auto-balancing bridge method provides outstanding basic accuracy of 0.08% across a wide range of impedance values In contrast, the Keysight E4991B impedance analyzer (1 MHz to 3 GHz) uses the RF I-V method (Figure 4). The instrument architecture includes a source/receiver mainframe and a separate test-head module that senses high-frequency voltage and current very close to the DUT. Note, however, that it cannot cover the low-frequency range (e.g., below 1 MHz) because it uses a current-sensing transformer. Current meas. channel Source Voltage meas. channel Receiver V Z DUT Figure 4. Although the RF I-V method is less accurate than the auto-balancing bridge, it is more accurate than the VNA-based reflection method; it also has a wider measurement range.

06 Keysight Performing Impedance Analysis with the E5061B ENA Vector Network Analyzer - Application Note Taking a closer look: Network analyzer methods The optional ZA firmware for the E5061B supports the reflection, series-through and shunt-through methods. In addition, the series- and shunt-through methods can be used with either the gain-phase or S-parameter test ports. Each approach has advantages over specific frequency and impedance ranges. Traditionally, the reflection method has been most commonly used in the middle- and high-frequency ranges. Using the familiar scattering parameters (S-parameters) from vector network analysis, the reflection method derives impedance values from S 11 measurement data (Figure 5). Z DUT = 50 x (1+S 11 )/(1 S 11 ) S 11 = V T /V R Z DUT V T V R Figure 5. A simple math operation relative to S 11 and the 50-Ω input impedance produces the impedance of the DUT. In terms of impedance values, the 10% accuracy range is about 1 Ω to 2 kω (supplemental performance data), and this is a bit narrower than what is possible when using the RF I-V method in a dedicated impedance analyzer. The reflection method is the better choice when lower frequency coverage is needed, and this is made possible by the broadband S-parameter test set in the E5061B-3Lx. The series-through method measures impedance by connecting the DUT in a transmission series connection, as shown in both block diagrams in Figure 6. As noted earlier, you can use this method with either the gain-phase or S-parameter test ports. Series-through is most effective when measuring high impedance values: the 10% accuracy range is about 5 Ω to 20 kω or roughly one decade higher than the reflection method. Zdut = 50 x S21/(2 x (1-S21)) Z DUT Z DUT V T T/R = V T /V R V R 1 MΩ V T S 21 = V T /V R V R Figure 6. Depending on the impedance range of interest, you may want to use the series-through method with the gain-phase port (left) or the S-parameter port (right). As suggested by the diagrams, you cannot measure a grounded DUT with this method

07 Keysight Performing Impedance Analysis with the E5061B ENA Vector Network Analyzer - Application Note Using the gain-phase port offers the convenience of directly connecting four-terminal pair-type component test fixtures; its maximum frequency is 30 MHz. You can reach higher frequencies with the S-parameter test port and your own custom test fixture. Note that the maximum measurement frequency is in the range of 200 MHz to 300 MHz because it is difficult to fully eliminate measurement errors around the series-through fixture at frequencies above a few hundred megahertz. The shunt-through method measures impedance by connecting the DUT in the transmission-shunt configuration shown in Figure 7. This is good way to characterize very low impedance values, and it is commonly used to make measurements in the milliohm range (e.g., power integrity applications). With the gain-phase port the 10% accuracy range spans 1 mω to 5 Ω, which is lower than typical impedance analyzers can reach. Z DUT = 50 x S 21 /(2 x (1 S 21 )) S 21 = V T /V R V T Z DUT V R Figure 7. Similar to the reflection measurement, a simple math operation relative to S 21 and the 50-Ω input impedance produces the impedance of the DUT. For low-impedance measurements above 30 MHz, using the shunt-through method with the S-parameter port is the best solution. When measuring below 100 khz, we recommend using the gain-phase port because its unique semi-floating receiver architecture eliminates the measurement errors caused by ground loops. 1 Figure 8 shows the respective connections to the E5061B. DUT Power splitter DUT Figure 8. When using the shunt-through method with the gain-phase port (left), use a power splitter between the reference input and the DUT input. This is not necessary with the S-parameter port (right) because the analyzer has a built-in directional bridge. 1. For more information about the semi-floating architecture, please see page 17 of the application note Evaluating DC-DC Converters and PDN with the E5061B LF-RF Network Analyzer, publication 5990-5902EN

08 Keysight Performing Impedance Analysis with the E5061B ENA Vector Network Analyzer - Application Note Selecting the Best Method for Your Application As a visual summary of the preceding section, Figure 9 provides a graphical comparison of the respective 10% accuracy ranges versus impedance and frequency for all five methods. 1.E+06 1.E+05 1.E+04 GP Series (T _20 db, R 1M Ω_20 db) GP Shunt (T _0 db, R _20 db) 1.E+03 1.E+02 Gain-phase series-through method 1.E+01 1.E+00 1.E-01 1.E-02 Gain-phase shunt-through method 1.E-03 1.E-04 1.0E+00 1.0E+01 1.0E+02 1.0E+03 1.0E+04 1.0E+05 1.0E+06 1.0E+07 1.0E+08 1.0E+09 1.0E+10 Frequency (Hz) Port1 Reflection Port1-2 Shunt Port1-2 Series 1.E+06 1.E+05 1.E+04 1.E+03 1.E+02 1.E+01 1.E+00 1.E-01 1.E-02 Port 1-2 series- through method Port 1 reflection method Port 1-2 shunt- through method 1.E-03 1.E-04 1.0E+00 1.0E+01 1.0E+02 1.0E+03 1.0E+04 1.0E+05 1.0E+06 1.0E+07 1.0E+08 1.0E+09 1.0E+10 Frequency (Hz) Figure 9. These graphs show the best frequency and impedance ranges for each of the measurement methods specific to either the gain-phase (upper) or S-parameter (lower) test ports. 1 1. Notes for Figure 9: The lower-right portion of the orange area (upper graph) was affected by 20 ph of residual inductance; the lower-left portion of the red area (lower graph) was affected by use of magnetic cores to measure very low impedance at low frequencies; the lower-right portion of the red area was affected by 20 ph of residual inductance.

09 Keysight Performing Impedance Analysis with the E5061B ENA Vector Network Analyzer - Application Note Table 1 provides a summary that will help you select the best measurement method for your application. Note the short lists of example DUTs in the right-most column. Table 1. The attributes of your application will help you determine which VNA-based method will provide the best results Frequency range Below 100 MHz Above 100 MHz Impedance range Recommended port and method Example DUTs Less than 100 mω Gain-phase with shunt-through up to 30 MHz; S-parameter (Port 1-2) with shunt-through above 100 khz 1 Ω to 10 kω S-parameter (Port 1-2) with reflection Greater than 10 kω Less than 100 mω Gain-phase with series-through up to 30 MHz; S-parameter (Port 1-2) with series-through up to 300 MHz S-parameter (Port 1) with shunt-through 1 to 2 kω S-parameter (Port 1-2) with reflection DC-DC converters; mid- or large-size bypass capacitors; power distribution networks (PDNs) Inductors, transformers, resonators Small capacitors, resonators, inductors and transformers Small bypass capacitors; PDNs RF inductors and capacitors; other RF passive components As a final comment, we recommend a dedicated impedance analyzer such as the E4990A and E4991B in the following cases: You need very high measurement accuracy (e.g., less than 1%) You need to measure high impedance values (>10 kω) very accurately You need to measure devices with very high Q (X/R >100) or very low D (R/X <0.01) You need to measure magnetic or dielectric materials Please see the sidebar Achieve unparalleled accuracy for more information about the E4990A and E4991B. Migrate to the latest capabilities Our previous-generation network/impedance combination analyzers, carrying the HP or Agilent brand, are widely used for component characterization. If you are looking to upgrade to the latest capabilities, we have four recommended migration paths, three of which are based on the E5061B with the 3 GHz frequency range and impedance analysis firmware (Options 3L5 and 005, respectively). Achieve unparalleled accuracy Keysight s E4990A and E4991B impedance analyzers let you see the real characteristics of your components from milliohm to megohm. Both are available with a variety of frequency options to meet current needs and budgets, and frequency upgrades make it easy to meet future requirements. The E4990A covers 20 Hz to 10, 20, 30, 50 or 120 MHz and delivers an industry-best basic accuracy of 0.045% (typical) over a wide impedance range; it also includes a built-in 40 V DC bias source. The E4991B covers 1 MHz to 500 MHz, 1.0 GHz or 3.0 GHz and provides basic accuracy of 0.65% over a wide impedance range; a built-in 40 V DC bias source is available (Option 001). The E4991B also offers materials-measurement options including analysis of temperature characteristics (Option 007) and direct readings of permittivity and permeability (Option 002). If you are using either the 4195A+41951A or the 4395A/96x+43961A to measure high impedances, we recommend the E5061B configuration with the reflection method. If you need to reach higher frequencies or are measuring low impedances, we recommend the E5061B-3L5/005 and the gain-phase test port with the series-through method. For milliohm measurements of large capacitors or DC-to-DC converters, consider the E5061B configuration and the shunt-through method. Finally, we recommend the E4990A or E4991B impedance analyzers if you are measuring high-q/low-d devices.

10 Keysight Performing Impedance Analysis with the E5061B ENA Vector Network Analyzer - Application Note Ensuring Accurate Results: Calibration and More In network analysis and impedance analysis, we can improve measurement accuracy by removing the systematic errors caused by the test setup: instrument, cables, connectors, fixtures, and so on. When performing impedance analysis with a network analyzer, this error-correction or calibration process can involve a variety of techniques and accessories (i.e., cal standards ). This section starts with a brief look at calibration in two-port network analysis, using it to provide context for error-correction as applied to the reflection, series-through and shunt-through measurement methods. Calibration for two-port network analysis The series-through and shunt-through methods are based on a two-port transmission measurement. If we use an S21 measurement configuration with 50-Ω system impedance, then we can apply VNA calibration methods such as response-through and twoport full short, open, load, through or SOLT when making impedance measurements. Response-through uses characterization of a thru standard to eliminate magnitude and phase-shift errors. SOLT uses a series of measurements to eliminate the bidirectional error factors transmission and reflection present in the two-port measurement system (Figure 10). Port 1 Port 2 Port 1 Port 2 Open Short Open Short Thru S 21 S 11 S 22 Load Load S 12 Figure 10. A full two-port calibration with the SOLT method requires a cal kit containing four standards three impedance and one transmission and is used to define the calibrated reference plane.

11 Keysight Performing Impedance Analysis with the E5061B ENA Vector Network Analyzer - Application Note Calibration for impedance analysis Focusing solely on impedance measurements, we can instead treat the network analyzer as a linear measurement system (e.g., just another black box) and apply the simpler open/short/load calibration technique (Figure 11). V i Linear system for measuring vector voltage ratio (reflection, series - through, shunt- through, etc.) V v Z x Z m B Z x = A 1 CZ m Z m :raw Z from measured data Z x :actual Z of DUT Figure 11. The calibration process derives the three complex-valued coefficients A, B and C by measuring open, short and load standards with known Z values. The black-box model is valid if it satisfies these conditions: It is operating in the linear region of its response (e.g., no gain compression or distortion) We can distinguish the open, short and load standards with measured voltages The load device remains stable during the measurement process To automate and simplify the process, the E5061B-005 impedance firmware provides an Impedance Calibration function that can be used with all three measurement methods reflection, series-through and shunt-through. Calibrating for the reflection method The typical approach is to calibrate the measurement plane defined at the 7 mm coaxial connectors. In the E5061B, this uses the port extension (i.e., electrical length) fixture model to compensate for the phase shift in the coax section. In addition, the open-short compensation will eliminate the effects of stray capacitance and residual inductance around the fixture s electrodes. When performing the open/short/load calibration at the 7 mm connector plane, you can use either the Impedance Calibration function or the conventional full one-port calibration function. With Impedance Calibration, you can perform a low-loss capacitor calibration with an air capacitor (included with the 16195B cal kit) in addition to the open/short/load cal (Figure 12). This will improve the accuracy of phase, Q or D measurements above 300 MHz by reducing the phase uncertainty of the 50-ohm load termination. 7 mm fixture residual Z & stray C phase shift in coax section open/short compensation electrical-length compensation (port extension) To Port-1 16201A terminal adapter 7 mm connector open/short/load calibration (optional: include low - loss capacitor calibration) semi-rigid cable Figure 12. Combining the three techniques shown here will compensate for systematic effects out to the measurement plane at the 7 mm connector.

12 Keysight Performing Impedance Analysis with the E5061B ENA Vector Network Analyzer - Application Note Calibrating series-through With series-through and the gain-phase test port, the typical approach is to use an open/short/load calibration at the four-port fixture (Figure 13). To enhance the accuracy of this technique, we offer resistors (leaded and SMD-type) as accessories to the E5061B (Option 720). L c L p Z DUT O/S/L cal at four-port fixture T R LF OUT input 1 MΩ input source H p H c open short Figure 13. This approach ensures better results when measuring small capacitors, resonators, inductor and transformers up to 30 MHz. For measurements using the S-parameter test port above 30 MHz, the most practical method is a SOLT calibration at the coaxial cables plus the port extension to compensate for the transmission lines on the user-prepared test board. As an additional step, you can perform an open compensation to remove stray capacitance at the measurement terminals (Figure 14). use open compensation to eliminate stray capacitance SOLT cal port extension Figure 14. This method provides better results when measuring small capacitors, resonators, inductors and transformers up to 300 MHz. Calibrating shunt-through We use the gain-phase port and the shunt-through method when measuring low impedances at low frequencies. In this case, a simple response-through calibration is usually the best choice because it provides sufficient accuracy in the milliohm range. This is true when measuring either the absolute value of the impedance or the capacitance and inductance elements of complex-valued impedance. If you need to measure impedances greater than 1 Ω, or if you are measuring phase or equivalent series resistance (ESR) at higher frequencies, then we recommend the open/ short/load calibration. This will remove more error factors than is possible with the response-through method. The process becomes a bit more complex when using the S-parameter test port to make measurements into the megahertz or gigahertz range. In this situation, the best choice is a SOLT calibration at the coaxial cables plus the port-extension procedure to compensate for fixtures and probes (Figure 15). When using an RF probe station, perhaps when characterizing IC packages or printed-circuit boards, you should perform a SOLT calibration at the ends of the probes using calibration standards provided by the probe manufacturer. port extension SOLT cal Figure 15. At higher frequencies, combining SOLT and port extension provides more accurate results with the Port 1-2 shunt-through method.

13 Keysight Performing Impedance Analysis with the E5061B ENA Vector Network Analyzer - Application Note Enhancing measurement accuracy A few more tips will help you get better results when using the E5061B network analyzer. As an overall suggestion, it is best to set the source for moderate power levels: this helps ensure that the receivers are operating in regions of sufficient linearity. For example, set the power level to less than 0 dbm when using the reflection method. This will help prevent the expansion of S-parameter errors after conversion to the impedance domain. A level of less than 10 dbm is desirable when measuring small resistance values in reactive devices with high Q (or low D). Specific to the series-through method, we recommend using fixtures that hold the load very tightly. Examples of such fixtures include the Keysight 16047E (leaded DUTs) and the 16034E/G/H for SMD devices. Four more tips will improve your results with the shunt-through method. First, always inspect your cables and connectors for damage: it can increase outer-shield resistance and offset the benefits of semi-floating receivers and magnetic cores. Second, use good technique when probing above 10 MHz: this will ensure that you minimize the inductive errors that may be caused by inter-probe coupling. Tip #3: If you are performing an open/short/load calibration, enter the resistance and inductance values from the cal kit definitions: this will avoid an excessive number of subtraction operations in the milliohm range. You can obtain those values by measuring a short using the gain-phase shunt method with a through calibration. Fourth, use two-port contact to minimize the effect of contact resistance. As shown in Figure 16, contact resistances are in series with the analyzer s 50-Ω system impedance, which is much greater than R c. Consequently, R c will have much less effect on the measurement. In addition, the residual inductances at (a) and (b) will also have less impact on your results. At high frequencies, phase shifts at (a) and (b) will affect your measurements. You can compensate for this in either of two ways: when using through calibration, use a through device with length equal to (a)+(b); when using SOLT, use the port-extension function. Port-1 () (a) (b) Port-2 () R c R c Z DUT (very small Z) Figure 16. A two-port contact provides a variety of benefits when using the shunt-through method.

14 Keysight Performing Impedance Analysis with the E5061B ENA Vector Network Analyzer - Application Note Examining Real-world Examples A few typical measurement scenarios will illustrate the benefits of the techniques presented in the preceding sections: inductors and capacitors; a crystal resonator; DC-biased measurements; and circuit impedance. Characterizing inductors and capacitors For basic component measurements, the E5061B can accurately measure impedance if you choose the most effective method and apply the recommended tips. A general set of examples includes using the reflection method with a 100 nh inductor, the gain-phase series-through method with a 10 nf capacitor, and the gain-phase shunt-through method with a 200 µf capacitor. One way to assess the results is to compare E5061B measurements with those made with dedicated impedance analyzers. In the inductor example it takes two impedance analyzers to cover the full frequency range of the E5061B (5 Hz to 3 GHz). Figure 17 shows overlays of results obtained with the E5061B, 4294A and E4991A (predecessors of the E4990A and E4991B, respectively). Note that measurements from the 4294A (orange) cover 10 khz to 100 MHz; the E4991A (purple) covers 1 MHz to 3 GHz. Clearly, there is good data agreement in the results for inductance (upper trace) and Q (lower). 3.5E-07 2.5E-07 L s (H) 1.5E-07 5.0E-08-5.0E-08-1.5E-07 10 1.E+04 khz 1.E+05 100 k 11.E+06 M 101.E+07 M 100 1.E+08 M 1 GHz 1.E+09 E5061B Reflection Reflection 4294A (4 avg) E4991A E4991A (8 avg) 60 50 Q 40 30 20 10 E5061B Reflection 4294A (4 avg) E4991A (8 avg) 0 1.E+04 10 khz 1.E+05 100 k 1.E+06 1 M 1.E+07 10 M 100 1.E+08 M 11.E+09 GHz Figure 17. The E5061B delivers comparable results for an inductor with moderate Z and Q values that are relatively easy to measure Applying the suggestions presented in this note, settings for the E5061B were 10 khz to 3 GHz, 10 dbm source level and 30 Hz IF bandwidth. Error-correction methods were open/short/load calibration plus low-loss capacitance calibration, port extension, and open-short compensation.

15 Keysight Performing Impedance Analysis with the E5061B ENA Vector Network Analyzer - Application Note Characterizing a crystal resonator A high-q crystal resonator provides additional insight into the process of making successful impedance measurements with a network analyzer. Figure 18 shows magnitude (top, blue) and phase (bottom, red) responses in a 30 khz span centered at 14.4 MHz. The resonant and anti-resonant frequencies are clearly visible in both traces: in the magnitude trace F r is the notch on the left and F a is the peak on the right; those correspond to the zero-crossing transitions in the phase trace. The lower-left corner of the display shows the R 1, C 1, L 1 and C 0 values computed by the equivalent circuit analysis function in the E5061B-005: R 1 is 14.4 Ω, C 1 is 7.3 ff, L 1 is 16.7 mh, and C 0 is 2.8 pf. However, the upper-left readout for marker 1, which is in the resonance at 14.4 MHz, shows a value of 21.3 Ω for CI ( Z at zero degrees phase). Unfortunately, this is higher than the known CI value for the DUT. To accurately measure CI, it is necessary to use a slower sweep rate and increase the number of measurement points around the resonance. Figure 19 shows a measurement made with a narrower span around the resonance: this yields a smaller IF bandwidth, which reduces the sweep rate and provides greater resolution in the area surrounding F r. In this case the value for CI is 14 Ω, which is correct. One caveat: Because the anti-resonance is not within the measurement span, the equivalent circuit model will produce an erroneous value for C 0 (in this case 2.89 pf rather than 2.77 pf). Figure 18. Although this measurement of a high-q crystal resonator has the expected characteristics, adjusting the measurement settings will improve the computed equivalent circuit values Adding a DC bias To evaluate components under their expected operating conditions, it may be necessary to apply a bias voltage or current and then measure the impedance. Figure 20 shows a set of measurements from a 100 nf ceramic capacitor that has a strong dependency on the applied DC voltage. These were performed using the gain-phase series-through method and the DC bias was applied using the E5061B s internal DC source. Figure 19. Using a narrower frequency span around the resonance provides a correct value for CI. The upper trace shows the swept-frequency measurements performed using channel 1: Z, phase, C s and R s. The lower trace shows the results of a DC-bias sweep from 10 to +10 volts DC; a 10 khz continuous-wave signal was also applied. In this case capacitance ranged from 70 nf at ±10 V, 94 nf at 0 V, and 104 nf at ±2.5 V. Similarly, you can use an external power supply to inject a large DC current to bias power inductors and ferrite beads. This also requires use of a DC current bias adapter such as the Keysight 16200B and an external DC source to apply DC current through the adapter to the DUT. Figure 20. Sweeping the DC bias voltage provides a clear picture of capacitance varying with voltage changes.

16 Keysight Performing Impedance Analysis with the E5061B ENA Vector Network Analyzer - Application Note Adding an AC bias The characterization of high-power components such as ultrasound resonators, ceramic actuators and power inductors often requires the addition of an AC bias. With the E5061B, it is necessary to increase the analyzer s source output level using an external power amplifier. This requires use of the gain-phase test port, the series-through method, and the 1 MΩ input impedance of the transmission and reflection inputs. As shown in Figure 21, it is also necessary to add two user-created voltage-divider circuits to reduce the AC levels at the inputs (maximum input level is 1.78 V peak with 20 db attenuation). Finally, an external high-power resistor (1 to 10 Ω) is also needed: R c is used to detect the AC current flowing through the DUT. The recommended calibration method is open/short/load; however, it is necessary to reduce the power amplifier output to a level the load can tolerate. Figure 21. Surrounding the DUT with the external elements shown here makes it possible to measure a variety of high-power components. Measuring in-circuit impedance A variety of applications require in-circuit measurements of impedance: printed RFID antennas, negative-impedance oscillator circuits and power integrity are just a few examples. When working in the megahertz range (e.g., RFID) hand probing may be used, and the reflection method is recommended. An example probe would consist of a semi-flexible SMA cable with a non-metal coating and the head of the Keysight 42941A impedance probe. Characterization of a DC-to-DC converter works well with the gainphase shunt-through method due to the combination of low impedance and low frequency (e.g., less than 10 MHz). 1 As shown in Figure 22, it is necessary to insert 1 mf capacitors to block DC voltages when the DUT output voltage exceeds 5 V. Power supply R&T: inputs DUT feedback loop load Solder SMA receptacles to the DUT output port Conclusion Figure 22. This configuration enables accurate measurements of the output impedance of a DC-DC converter in its on and off states. When the E5061B is equipped to provide NA and ZA capabilities, it puts greater versatility on your R&D bench. Although E5061B-005 cannot match the ultimate overall performance of a dedicated impedance analyzer, it does enable you to apply measurement methods, calibration techniques, and fixturing choices that provide comparably accurate impedance measurements. Every Keysight VNA is the ultimate expression of our expertise in linear and nonlinear device characterization. To learn more, please visit www. keysight.com/find/vna. 1. For more information, refer again to the Evaluating DC-to-DC Converters application note (5990-5902EN).

17 Keysight Performing Impedance Analysis with the E5061B ENA Vector Network Analyzer - Application Note Related Information Brochure: E5061B Vector Network Analyzer, publication 5990-6794EN Data sheet: E5061B Vector Network Analyzer, publication 5990-4392EN Configuration Guide: E5061B Vector Network Analyzer, publication 5990-4391EN Data sheet: LF-RF Network Analyzer with Option 005 Impedance Analysis Function, publication 5990-7033EN Brochure: E4990A Impedance Analyzer, publication 5991-3888EN Application Note: Evaluating DC-DC Converters and PDN with the E5061B LF-RF Network Analyzer, publication 5990-5902EN mykeysight www.keysight.com/find/mykeysight A personalized view into the information most relevant to you. Keysight Services www.keysight.com/find/service Keysight Services can help from acquisition to renewal across your instrument s lifecycle. Our comprehensive service offerings one-stop calibration, repair, asset management, technology refresh, consulting, training and more helps you improve product quality and lower costs. Three-Year Warranty www.keysight.com/find/threeyearwarranty Keysight s committed to superior product quality and lower total cost of ownership. Keysight is the only test and measurement company with three-year warranty standard on all instruments, worldwide. And, we provide a one-year warranty on many accessories, calibration devices, systems and custom products. Keysight Assurance Plans www.keysight.com/find/assuranceplans Up to ten years of protection and no budgetary surprises to ensure your instruments are operating to specification, so you can rely on accurate measurements. Keysight Channel Partners www.keysight.com/find/channelpartners Get the best of both worlds: Keysight s measurement expertise and product breadth, combined with channel partner convenience. www.keysight.com/find/e5061b For more information on Keysight Technologies products, applications or services, please contact your local Keysight office. The complete list is available at: www.keysight.com/find/contactus Americas Canada (877) 894 4414 Brazil 55 11 3351 7010 Mexico 001 800 254 2440 United States (800) 829 4444 Asia Pacific Australia 1 800 629 485 China 800 810 0189 Hong Kong 800 938 693 India 1 800 11 2626 Japan 0120 (421) 345 Korea 080 769 0800 Malaysia 1 800 888 848 Singapore 1 800 375 8100 Taiwan 0800 047 866 Other AP Countries (65) 6375 8100 Europe & Middle East Austria 0800 001122 Belgium 0800 58580 Finland 0800 523252 France 0805 980333 Germany 0800 6270999 Ireland 1800 832700 Israel 1 809 343051 Italy 800 599100 Luxembourg +32 800 58580 Netherlands 0800 0233200 Russia 8800 5009286 Spain 800 000154 Sweden 0200 882255 Switzerland 0800 805353 Opt. 1 (DE) Opt. 2 (FR) Opt. 3 (IT) United Kingdom 0800 0260637 For other unlisted countries: www.keysight.com/find/contactus (BP-6-20-17) DEKRA Certified ISO9001 Quality Management System www.keysight.com/go/quality Keysight Technologies, Inc. DEKRA Certified ISO 9001:2015 Quality Management System This information is subject to change without notice. Keysight Technologies, 2017 Published in USA, July 26, 2017 5991-0213EN www.keysight.com