Permanent Magnet Generators (PMG)

Similar documents
Upgrading from Stepper to Servo

Electric Power Systems 2: Generators, Three-phase Power, and Power Electronics

Excitation systems and automatic voltage regulators

3.1.Introduction. Synchronous Machines

AGN 124 AVR Power Supplies

DC-Voltage fluctuation elimination through a dc-capacitor current control for PMSG under unbalanced grid voltage conditions

AGN 124 AVR Power Supplies

Step vs. Servo Selecting the Best

Contents. About the Authors. Abbreviations and Symbols

DESIGN STUDY OF LOW-SPEED DIRECT-DRIVEN PERMANENT-MAGNET MOTORS WITH CONCENTRATED WINDINGS

3. What is hysteresis loss? Also mention a method to minimize the loss. (N-11, N-12)

DC Machine Construction. Figure 1 General arrangement of a dc machine

WDG 13 - Technical Data Sheet

WDG 83 - Technical Data Sheet

VALLIAMMAI ENGINEERING COLLEGE

DATAMAX GENERATORS DATA C E NT E R A P P L I C AT I O N S, TO K W LOW A N D H I G H VO LTAG E, 6 0 A N D 5 0 H Z

AC Drive Technology. An Overview for the Converting Industry. Siemens Industry, Inc All rights reserved.

Code No: R Set No. 1

SYNCHRONOUS MACHINES

The synchronous machine as a component in the electric power system

Combined analytical and FEM method for prediction of synchronous generator no-load voltage waveform

Page ENSC387 - Introduction to Electro-Mechanical Sensors and Actuators: Simon Fraser University Engineering Science

Generalized Theory Of Electrical Machines

THE UNIVERSITY OF BRITISH COLUMBIA. Department of Electrical and Computer Engineering. EECE 365: Applied Electronics and Electromechanics

Top-Innovator EncoderAnalyzer. For testing encoders. Made in Germany Expect more. Winding testers

Low Voltage Alternators

NVH analysis of a 3 phase 12/8 SR motor drive for HEV applications

A Practical Guide to Free Energy Devices

ELECTRIC MACHINES MODELING, CONDITION MONITORING, SEUNGDEOG CHOI HOMAYOUN MESHGIN-KELK AND FAULT DIAGNOSIS HAMID A. TOLIYAT SUBHASIS NANDI

Synchronous Machines Study Material

Analysis of Single Phase Self-Excited Induction Generator with One Winding for obtaining Constant Output Voltage

Finite Element Analysis of Cogging Torque in Low Speed Permanent Magnets Wind Generators

Smooth rotation. An adaptive algorithm kills jerky motions in motors.

6. List two possible arrangements of a Yconnection and give one application

Types of Generators ACCORDING TO EXCITATION

POWER FACTOR IMPROVEMENT USING CURRENT SOURCE RECTIFIER WITH BATTERY CHARGING CAPABILITY IN REGENERATIVE MODE OF SRM

OPTIMUM DESIGN ASPECTS OF A POWER AXIAL FLUX PMSM

A NOVEL SWITCHING PATTERN OF CASCADED MULTILEVEL INVERTERS FED BLDC DRIVE USING DIFFERENT MODULATION SCHEMES

Placement Paper For Electrical

EE171. H.H. Sheikh Sultan Tower (0) Floor Corniche Street Abu Dhabi U.A.E

Three-Phase Induction Motors. By Sintayehu Challa ECEg332:-Electrical Machine I

NEW DEVELOPMENTS IN FLUX MONITORING FOR TURBINE GENERATORS. M. Sasic, B. A. Lloyd and S.R. Campbell Iris Power LP, Mississauga, Ontario, Canada

PESIT Bangalore South Campus Hosur road, 1km before Electronic City, Bengaluru -100 Department of Electronics & Communication Engineering

TRACK VOLTAGE APPROACH USING CONVENTIONAL PI AND FUZZY LOGIC CONTROLLER FOR PERFORMANCE COMPARISON OF BLDC MOTOR DRIVE SYSTEM FED BY CUK CONVERTER

WDG 12 - Technical Data Sheet

A NEW C-DUMP CONVERTER WITH POWER FACTOR CORRECTION FEATURE FOR BLDC DRIVE

CHAPTER 6 FABRICATION OF PROTOTYPE: PERFORMANCE RESULTS AND DISCUSSIONS

WDG 07 - Technical Data Sheet

WDG 61 - Technical Data Sheet

Generator Advanced Concepts

WDG 71 - Technical Data Sheet

Eyenubo, O. J. & Otuagoma, S. O.

WDG 12 - Technical Data Sheet

AC generator theory. Resources and methods for learning about these subjects (list a few here, in preparation for your research):

ELG2336 Introduction to Electric Machines

WDG 51 - Technical Data Sheet

Sizing Generators for Leading Power Factor

WDG 12 - Technical Data Sheet

WDG 12 - Technical Data Sheet

Simulation of Solar Powered PMBLDC Motor Drive

Basic NC and CNC. Dr. J. Ramkumar Professor, Department of Mechanical Engineering Micro machining Lab, I.I.T. Kanpur

Cylindrical rotor inter-turn short-circuit detection

Volume 1, Number 1, 2015 Pages Jordan Journal of Electrical Engineering ISSN (Print): , ISSN (Online):

Asynchronized turbogenerators and compensators for improving the electric power quality

A Practical Guide to Free Energy Devices

A NOVEL DOUBLE-WINDING PERMANENT MAGNET FLUX MODULATED MACHINE FOR STAND-ALONE WIND POWER GENERATION

Motor-CAD Brushless PM motor Combined electromagnetic and thermal model (February 2015)

INSTITUTE OF AERONAUTICAL ENGINEERING (AUTONOMOUS) Dundigal, Hyderabad

ServoStep technology

AC Machinery. Revised October 6, Fundamentals of AC Machinery 1

Assembly Language. Topic 14 Motion Control. Stepper and Servo Motors

Multiple Rotation Absolute Sensor

UG Student, Department of Electrical Engineering, Gurunanak Institute of Engineering & Technology, Nagpur

PI734C - Technical Data Sheet

MICROCONTROLLERS Stepper motor control with Sequential Logic Circuits

DC CIRCUITS Part I of III Parts. Part II installation. Part III troubleshooting

PI734A - Technical Data Sheet

Armature Windings - Nptel Coil Pitch In An Ac Armature Winding Full Pitch Winding Dc Motor Basics - Abb Group

Objective: Study of self-excitation characteristics of an induction machine.

consequences of incorrect control. resistor and its associated breaker.

PART 2 - ACTUATORS. 6.0 Stepper Motors. 6.1 Principle of Operation

PI734F - Winding 07. Technical Data Sheet APPROVED DOCUMENT

Rare-Earth-Less Motor with Field Poles Excited by Space Harmonics

PMSM TECHNOLOGY IN HIGH PERFORMANCE VARIABLE SPEED APPLICATIONS

PI734F - Winding 28. Technical Data Sheet APPROVED DOCUMENT

CURRENT FOLLOWER APPROACH BASED PI AND FUZZY LOGIC CONTROLLERS FOR BLDC MOTOR DRIVE SYSTEM FED FROM CUK CONVERTER

PM734B - Technical Data Sheet. Generator Solutions AS

EFFICIENCY APPLICATION NOTES. Power Purifier - IPP#15. General. Why is it Important to Consider Efficiency?

SPEED CONTROL OF SENSORLESS BLDC MOTOR WITH FIELD ORIENTED CONTROL

PI734E - Winding 312. Technical Data Sheet APPROVED DOCUMENT

PI734C - Winding 312. Technical Data Sheet APPROVED DOCUMENT

CHAPTER 2 D-Q AXES FLUX MEASUREMENT IN SYNCHRONOUS MACHINES

PI734B - Winding 312. Technical Data Sheet APPROVED DOCUMENT

WIND MONITOR ANEMO / WIND VANE YOUNG ALPINE

Sensorless Drive for High-Speed Brushless DC Motor Based on the Virtual Neutral Voltage

Introduction : Design detailed: DC Machines Calculation of Armature main Dimensions and flux for pole. Design of Armature Winding & Core.

Fractional-slot permanent magnet synchronous generator for low voltage applications

05-VAWT Generator Testing

Sequence Networks p. 26 Sequence Network Connections and Voltages p. 27 Network Connections for Fault and General Unbalances p. 28 Sequence Network

GOVERNMENT COLLEGE OF ENGINEERING, BARGUR

Transcription:

Permanent Magnet Generators (PMG) What is a PMG? A permanent magnet generator is a s y n c h r o n o u s generator in which the e x c i t a t i o n c o i l, normally in the rotor, has been replaced by a system made up of permanent magnets w h i c h p r o v i d e a constant excitation field. How does it work? The operation of the PMG differs greatly from a normal synchronous generator. In a normal generator, voltage is controlled by means of excitation. In a PMG, excitation is constant which is why, when the generator is charged, voltage drops without the option to regulate. What is it used for? It is used in those cases in which it does not matter if the voltage drops a certain degree or when electronics are applied to the output of the generator. The electronics can convert a voltage range i n t o continuous voltage of a constant value. What applications does it have? The PMGs manufactured by Obeki are used, for example, to feed the regulators which act in the excitation of large synchronous generators. The main benefit in these cases is that when there is a short-circuit in the large synchronous generator, they are capable of supplying the energy necessary to the regulator so that it can overexcite the generator and Permanent Magnet Generators, OBEKI S.A.Page 1 of 5

maintain the voltage sufficient time so that the protections can start. Another important use for our generators is wind power generation. By means of Obeki wind turbines, brushes and differential systems are eliminated, saving on maintenance, space and price. Permanent Magnet Generators, OBEKI S.A.Page 2 of 5

What advantages does it have? T h e m a i n a d v a n t a g e i s i t s simplicity. The manufacturing and assembly of the rotor is cheaper if magnets are used. They do not need maintenance because they do not have brushes. The mechanical consistency of a PMG is superior, in addition to not needing systems for its excitation. By eliminating the excitation, energy savings of 20% can be had by simply using magnets. By being an energy source which is independent from the generator, it can serve to supply energy to auxiliary systems of the main generator. type, are capable of working at up to 140ºC, 80ºC magnets being the standard. Obeki uses Neodym Cobalt magnets since they have the best properties. In the case of wind turbines, the magnets can be a problem since they generate reluctant pairs which do not allow for the start-up of the generator at low wind speeds. Obeki configures the generators to eliminate this effect. What is the voltage supplied by the PMG like? What are the magnets like? The magnets used by Obeki are cutting edge to e n s u r e t h e i r o p t i m u m operation. Normal magnets, when the magnetic circuit t h a t s u r ro u n d s them, lose their magnetization, while those used by Obeki maintain them, which is why the rotor can be separated from the stator without the fear of losing magnetic properties. The magnets used by Obeki, depending on the The wave shape generated by the PMG can almost be sine depending on the intended use. The construction shape of the rotor where the magnets are placed a r e o f g r e a t i n f l u e n c e. O b e k i manufactures PMGs with low harmonic l e v e l s, a s i n g l e magnet per pole, inclining the slots of the stator, etc.., or of a greater harmonic level, simple construction, lesser cost. The selection of one or Permanent Magnet Generators, OBEKI S.A.Page 3 of 5

another depends on the client s specifications. Permanent Magnet Generators, OBEKI S.A.Page 4 of 5

What voltages does it provide? How so I adapt it to my machine? The voltage supplied depends on the magnets, the coil and the revolutions. Obeki precisely calculates the output and adapts it to the client s needs, capable of supplying different PMGs at the same voltage for different speeds. Obeki manufactures PMGs from 200 rpm to 3600 rpm. To ease its clients work, Obeki adapts them to their needs. Obeki manufactures the PMGs so that they can be connected to the attachment the client needs. Obeki configures its PMG to assure their optimum operation, simplicity in assembly and construction to provide a simple, robust, reliable, stable, adaptable and profitable product to its clients. Permanent Magnet Generators, OBEKI S.A.Page 5 of 5