Nanometer-scale oxidation of Si(lO0) surfaces by tapping mode atomic force microscopy

Similar documents
Analysis of the process of anodization with AFM

Electric polarization properties of single bacteria measured with electrostatic force microscopy

A scanning tunneling microscopy based potentiometry technique and its application to the local sensing of the spin Hall effect

Akiyama-Probe (A-Probe) technical guide This technical guide presents: how to make a proper setup for operation of Akiyama-Probe.

Oxidation of hydrogen-passivated silicon surfaces by scanning near-field optical lithography using uncoated and aluminum-coated fiber probes

Study of shear force as a distance regulation mechanism for scanning near-field optical microscopy

- Near Field Scanning Optical Microscopy - Electrostatic Force Microscopy - Magnetic Force Microscopy

Akiyama-Probe (A-Probe) guide

Akiyama-Probe (A-Probe) guide

Outline: Introduction: What is SPM, history STM AFM Image treatment Advanced SPM techniques Applications in semiconductor research and industry

Nanovie. Scanning Tunnelling Microscope

A Project Report Submitted to the Faculty of the Graduate School of the University of Minnesota By

Keysight Technologies Using Non-Contact AFM to Image Liquid Topographies. Application Note

Distinguishing Between Mechanical and Electrostatic. Interaction in Single-Pass Multifrequency Electrostatic Force

Wu Lu Department of Electrical and Computer Engineering and Microelectronics Laboratory, University of Illinois, Urbana, Illinois 61801

attosnom I: Topography and Force Images NANOSCOPY APPLICATION NOTE M06 RELATED PRODUCTS G

MEMS for RF, Micro Optics and Scanning Probe Nanotechnology Applications

Park NX-Hivac: Phase-lock Loop for Frequency Modulation Non-Contact AFM

Supplementary Figure 1 Schematic illustration of fabrication procedure of MoS2/h- BN/graphene heterostructures. a, c d Supplementary Figure 2

Conductance switching in Ag 2 S devices fabricated by sulphurization

Figure for the aim4np Report

Status and Challenges for Probe Nanopatterning. Urs Duerig, IBM Research - Zurich

photolithographic techniques (1). Molybdenum electrodes (50 nm thick) are deposited by

Scanning Tunneling Microscope Nanolithography on SrRuO3 Thin

Giovanni P. Donati - MST-11 Daniel Some - MST-11 George Rodriguez - MST-11 Antoinette J. Taylor - MST-11

Investigate in magnetic micro and nano structures by Magnetic Force Microscopy (MFM)

Measurement of Microscopic Three-dimensional Profiles with High Accuracy and Simple Operation

Nanoscale Material Characterization with Differential Interferometric Atomic Force Microscopy

PACS Nos v, Fc, Yd, Fs

Mode analysis of Oxide-Confined VCSELs using near-far field approaches

Physics Faculty Publications and Presentations

Basic methods in imaging of micro and nano structures with atomic force microscopy (AFM)

Atomic Force Microscopy (Bruker MultiMode Nanoscope IIIA)

Lecture 20: Optical Tools for MEMS Imaging

Terahertz control of nanotip photoemission

Semiconductor Physics and Devices

IMAGING P-N JUNCTIONS BY SCANNING NEAR-FIELD OPTICAL, ATOMIC FORCE AND ELECTRICAL CONTRAST MICROSCOPY. G. Tallarida Laboratorio MDM-INFM

End-of-line Standard Substrates For the Characterization of organic

A New Profile Measurement Method for Thin Film Surface

Development of Si/SiO 2 Multilayer Type AFM Tip Characterizers

In this lecture we will begin a new topic namely the Metal-Oxide-Semiconductor Field Effect Transistor.

Scanning force microscopy in the dynamic mode using microfabricated capacitive sensors

Phase modulation atomic force microscope with true atomic resolution

Agilent Technologies Gli analizzatori di reti della serie-x

Keysight Technologies Scanning Microwave Microscopy Solutions for Quantitative Semiconductor Device Characterization.

Author(s) Issue Date Text Version author. DOI / /18/9/095501

Elimination of bistability in constant-phase mode in atomic force microscopy

DEVELOPMENT OF A SILICON NANOWIRE MASK USING SCANNING PROBE MICROSCOPY. A Thesis. presented to

Cavity QED with quantum dots in semiconductor microcavities

UNIVERSITY OF WATERLOO Physics 360/460 Experiment #2 ATOMIC FORCE MICROSCOPY

Lithographic Performance and Mix-and-Match Lithography using 100 kv Electron Beam System JBX-9300FS

LAB UNIT 1: Introduction Scanning Force Microscopy

Pattern Transfer CD-AFM. Resist Features on Poly. Poly Features on Oxide. Quate Group, Stanford University

January, 2004 Jeju Island. Acknowledgements OTFL

Supplementary Information: Nanoscale. Structure, Dynamics, and Aging Behavior of. Metallic Glass Thin Films

CHAPTER 2 POLARIZATION SPLITTER- ROTATOR BASED ON A DOUBLE- ETCHED DIRECTIONAL COUPLER

Integrated Focusing Photoresist Microlenses on AlGaAs Top-Emitting VCSELs

2. Pulsed Acoustic Microscopy and Picosecond Ultrasonics

SUPPLEMENTARY INFORMATION

SUPPORTING INFORMATION FOR

High-efficiency, high-speed VCSELs with deep oxidation layers

Resistive Switching Mechanisms on TaO x and SrRuO 3 Thin Film Surfaces Probed by Scanning Tunneling Microscopy

Atomic-layer deposition of ultrathin gate dielectrics and Si new functional devices

Alejandro Mendez, Ph.D. President & CEO Mendezized Metals Corporation

SUPPLEMENTARY INFORMATION

Fine structure of the inner electric field in semiconductor laser diodes studied by EFM.

A large-area wireless power transmission sheet using printed organic. transistors and plastic MEMS switches

Dominik Kufer and Gerasimos Konstantatos *

4H-SiC V-Groove Trench MOSFETs with the Buried p + Regions

Supporting Information. Air-stable surface charge transfer doping of MoS 2 by benzyl viologen

Gigahertz Ambipolar Frequency Multiplier Based on Cvd Graphene

Fabrication of a submicron patterned using an electrospun single fiber as mask. Author(s)Ishii, Yuya; Sakai, Heisuke; Murata,

Multi-Probe Atomic Force Microscopy Using Piezo-Resistive Cantilevers and Interaction between Probes

PH880 Topics in Physics

Nanotechnology, the infrastructure, and IBM s research projects

Standard Operating Procedure of Atomic Force Microscope (Anasys afm+)

Micro-nanosystems for electrical metrology and precision instrumentation

Characterization of Silicon-based Ultrasonic Nozzles

Near-field Optical Microscopy

PROBLEM SET #7. EEC247B / ME C218 INTRODUCTION TO MEMS DESIGN SPRING 2015 C. Nguyen. Issued: Monday, April 27, 2015

Constant Frequency / Lock-In (AM-AFM) Constant Excitation (FM-AFM) Constant Amplitude (FM-AFM)

Tip-induced band bending and its effect on local barrier height measurement studied by light-modulated scanning tunneling spectroscopy

New Pixel Circuits for Driving Organic Light Emitting Diodes Using Low-Temperature Polycrystalline Silicon Thin Film Transistors

CMOS Digital Integrated Circuits Lec 2 Fabrication of MOSFETs

INTRODUCTION TO MOS TECHNOLOGY

Supporting information: Visualizing the motion of. graphene nanodrums

Microscopic Basis for the Mechanism of Carrier Dynamics in an Operating p-n Junction Examined by using Light-Modulated Scanning Tunneling Spectroscopy

ATOMIC FORCE MICROSCOPY

3D simulations of the experimental signal measured in near-field optical microscopy

Supporting Information

SUPPLEMENTARY INFORMATION

ANALYSIS OF ELECTRON CURRENT INSTABILITY IN E-BEAM WRITER. Jan BOK, Miroslav HORÁČEK, Stanislav KRÁL, Vladimír KOLAŘÍK, František MATĚJKA

Nanofluidic Diodes based on Nanotube Heterojunctions

Defense Technical Information Center Compilation Part Notice

Precision microcomb design and fabrication for x-ray optics assembly

Self-navigation of STM tip toward a micron sized sample

Supplementary Materials for

Large Signal Displacement Measurement with an Asylum SA Atomic Force Microscope Rev B

3084 IEEE TRANSACTIONS ON NUCLEAR SCIENCE, VOL. 60, NO. 4, AUGUST 2013

NANOSCOPIC EVALUATION OF MICRO-SYSTEMS

Transcription:

Nanometer-scale oxidation of Si(lO0) surfaces by tapping mode atomic force microscopy F. P&ez-Murano, G. Abadal, N. Barniol,a) and X. Aymerich Department Fisica-Electr&x, Universitat Audnoma de Barcelona, 08193-Bellaterra, Spain J. Set-vat, P. Gorostiza, and F. Sanz Departament de Quimica-Fisica, Universitat de Barcelona, 08028-Barcelona, Spain (Received 31 May 1995; accepted for publication 25 August 1995) The nanometer-scale oxidation of Si(lQ0) surfaces in air is performed with an atomic force microscope working in tapping mode. Applying a positive voltage to the sample with respect to the tip, two kinds of modifications are induced on the sample: grown silicon oxide mounds less than 5 nm high and mounds higher than 10 run (which are assumed to be gold depositions). The threshold voltage necessary to produce the modification is studied as a function of the average tip-to-sample distance. Q 1995 American Institute of Ph.ysics. I. INTRODUCTION Scanning probe microscopes have been extensively used to perform nanometer- and atomic-scale modifications on a great variety of surfaces. Silicon is obviously one of the most interesting surfaces to modify at nanometer scale, and several approaches have been reported. In the first works, modifications were performed on H-passivated silicon surfaces by scanning tunneling microscopy (STM).2-5 Recently, some groups have used atomic force microscopy (AFM) to locally oxidize the silicon surface.6-g In particular, these modifications were performed in contact mode6-s and noncontact mode.g The as-grown oxide has been used by several authors as a lithographic mask, * being one of the most impressive applications, the recent fabrication of a 0.1,um channel metal-oxide-semiconductor CMOS) transistor by Minne et al. In the present paper we introduce the local oxidation of SiilOOj surface by AFM working in tapping mode (TMAFM). Briefly, in TMAFM the feedback loop keeps constant the oscillation amplitude (around a rms of tens of nanometers) of a relatively stiff cantilever (force constant around tens of N/m) that is vibrating at its resonance frequency (usually around 300 khz). In contrast with the noncontact AFM, the reduction of the amplitude in TMAFM is due to the strike of the tip on the surface in each cycle. The most remarkable advantages of this mode are the elimination of the lateral forces which reduces the damaging effect on the surface with respect to contact mode AFM, and the improvement in resolution compared to the noncontact AFM.13 II. EXPERIMENTAL All the experiments were performed with a Nanoscope III,r4 under normal ambient conditions with a relative humidity in the laboratory ranging between 70% and 80%. In order to know the average tip-to-sample distance, force-calibration curves were taken for each tip. In these curves, the uncalibrated rms oscillation amplitude is plotted versus the voltage applied to the Z piezo during consecutive approaches/ a~electronic mail: IFELl @CC.UAB.ES retractions of the tip. As the Z piezo is precisely calibrated and the amplitude decreases linearly,15 the rms signal can easily yield a direct measurement of the. tip-to-sample average distance. The samples were highly doped n-type Si(100) (surface resistivity of 0.02 fi cm). No cleaning of the sample was performed prior to the measurements, so that the surface was covered by a native oxide layer less than 2 nm thick. Similar results were obtained when the surface was etched and passivated with HF acid before doing the AFM modifications. The cantilevered tips (force constant between 15 and 90 N/m) are microfabricated in highly doped n-type silicon.16 In order to increase their conductivity, a gold layer of about 30 nm was evaporated on the tips. The sample was polarized with respect to the grounded tip as it is shown in Fig. 1. Voltage pulses were applied by the nanoscope built-in voltage source. A 100 k0 current limiter resistor has been added to preserve the tip quality. Besides, this resistor is also used * to measure the current between the tip and surface with the aid of an instrumentation amplifier with a gain of 200 (Fig. 1). The TMAFM normal imaging conditions have to be changed to produce a modification. The usual free oscillation amplitude of the tip (i.e., when the tip is far from the surface) is set to 30 nm for imaging. In the writing process, the free oscillation amplitude has been fixed at a lower value, 10 nm approximately. Then, the tip is approached to the surface until a reduction of the amplitude is detected. At this point the oscillation amplitude, which is a direct measurement of the tip-to-sample distance, is fixed at the desired value with the feedback activated. To write a single dot the feedback loop is disabled and a voltage pulse is applied to the sample with respect to the tip. The voltage must be above a threshold value to actually induce a modification. During the pulse, the tip continues oscillating but a reduction of the amplitude is observed. This reduction is attributed to the electrostatic attraction between the tip and sample. Just finished the writing process, the feedback loop is restored and the same coated tip is used to image the modified surface. We have found that the modification can also be obtained without disconnecting the feedback loop, but since an even lower tip-to-sample J. Appl. Phys. 78 (jl), 1 December 1995 0021-8979/95/78( 11)/6797/5/$6.00 Q 1995 American Institute of Physics 6797

PIG. 1. Experimental setup used to perform the modifications and to measure the current between tip and sample. V is the voltage source and R is the current-limiter resistor, which is also used to measure the current by means of an instrumentation amplifier. distance must be used, the consequences are a poor quality of the images and an increase of the damaging caused by the scanning process. III. RESULTS AND DISCUSSION Figure 2(a) is a TMAFM image of the silicon surface containing 16 modifications that appear as mounds with diameters of 60 irm and heights of 2 nm. In order to create each mound, a voltage pulse of 11 V is applied during 18 ms. The feedback loop was deactivated during the application of the voltage pulse and reactivated again after each pulse has been applied. Figure 2(b) is a TMAFM image of the same region (b) PIG. 3-.TMAFM images of Si(lO0) showing four dots and one line (a) before and (b) after an HP etching of the sample. Pulses are 10 V and 5 s for the dots and 10 V for the line with a tip velocity of 1,UXI/S. Note that the big mound at the end of the line is not etched away by the HP. The images (a) and (b) were acquired at different scanning orientations. FIG. 2. Tapping mode APM ( TMAPM) images of Si( 100) showing an array of 16 dots (a) before and (b) after an HP etching of the sample. Dots are written by voltage pulses of 11 V and 18 ms. Mounds are 60 nm wide and 2 nm high. after a HF etching of the sample (HF 40% HZ0 I:10 during 15 s). The 16 mounds have been etched and now 16 holes are imaged, having a similar diameter and a depth of around 1 nm, thus demonstrating that the modifications produced by the pulse are some form of silicon oxide. The measured ratio between the height of the mounds and the depth of the holes is different from that expected for a pure silicon dioxide, but the presence of the native oxide layer prevents the proof of any hypothesis about the stoichiometry of this silicon oxide. If the 100 ks1 resistor is not included in the circuit or accidental instabilities occur while modifying, a bigger mound appears occasionally on the surface after performing the modification. Figure 3(a) shows some examples of modifications produced on the surface under the following conditions: a voltage pulse of 10 V during 5 s has been applied for the dots, and a continuous voltage of 10 V and tip velocity of 1 pm/s for the line. A big mound has been formed at the end of the line. Figure 3(b) is an image of the same region after an HF etching. Holes of the expected size which correspond to the former mounds are found in all cases except for the biggest mound, which practically remains unaltered. This big mound should not correspond to an oxidized area, but probably to gold deposited from the tip. In fact, a number of 6798 J. Appl. Phys., Vol. 78, No. 11, 1 December 1995 Pkez-Murano et a/.

works have reported the feasibility of such depositions. 77 8 Usually, after depositing one of these mounds, the reproducibility of the oxide modifications is worst, it is much more difficult to oxidize the surface and the quality of the taken images decreases due to tip effects. Placing a 100 k!j resistor in the circuit, these depositions are almost eliminated Furthermore, when writing with uncoated tips, this kind of mounds are never obtained. When the oxidation of the silicon surface is induced by STM, the tunneling current is used as the feedback signal. In TMAFM no current is detected while applying the voltage pulse under any bias conditions, neither when the native silicon oxide exists on the surface nor when the sample is submitted to an HF etching prior to the modification process. Taking into account that voltages up to 11 V are applied and that the tunneling current flowing between tip and surface is much lower than 1 na, the conditions under which the modifications are produced in the case of TMAFM are different to those existing when the surface oxidation is performed by STM. The absence of current confirms that the electron dose does not control the oxidation process performed in air. On the contrary, it is assumed that the oxidation is induced and the kinetic rate is controlled by the applied electrical field between tip and surface. In order to point up the effect in the modification process of the tip-to-sample distance (which along with the polarization voltage will determine the electrical field), we have studied the variation of the threshold voltage required to produce a modification ( V,) with respect to the oscillation amplitude. As a general behavior, we have found that when the tip-to-sample average distance is decreased, Vti also decreases. The quantitative dependence is shown in Figs. 4(a)- 4(d) where the four images correspond to oscillation amplitudes of 5.3, 4.4, 3.5, and 2.6 nm, respectively. The value of the applied voltage is depicted above each~ modification and for all the modifications the pulse duration was 1 s. From these images, it seems evident that the average tip to sample distance affects the value of V,, but is has almost no effect on the modification dimensions. In other words, the lateral dimensions of the modification depend on the value of the applied voltage but do not depend on the average tip-tosample distance. Moreover, we have also found that V, does not depend on the pulse duration. This behavior can be explained if we keep in mind the high frequency of the cantilever oscillation (around 300 khz). The existence of a threshold voltage which in turn depends on the average tip-to-sample distance indicates that it also exists a threshold electrical field to start the oxidation of the surface. But in TMAFM, the tip touches the surface in each cycle. It means that the maximum value of the electrical field is the same for the same bias voltage independently of the average tip-to-sample distance. Thus, the threshold voltage versus average tip-to-sample distance dependence observed in Fig. 4 can only be explained if we assume that a threshold electrical field is necessary to oxidize the surface, and that a bigger electrical field than this threshold value has to continuously exist for a period of time larger than several microseconds, that is, during all the oscillation cycle of the cantilever. According to the chemical mechanism proposed (ill 1 Ill11 1,lln1 FIG. 4. TMAFM images of Si(100) of modifications performed at four different oscillating amplitudes: (a) 5.3 nm, (b) 4.4 nm, (c) 3.5 nm, (d) 2.6 nm The images show attempts to write a 16-dot array with pulses of 1 s and voltages decreasing from 11 to 3.5 V (values depicted above each dot). For each oscillating amplitude a different threshold (nonmodifying) voltage is found. by Snow and Campbell,7 in which the electrical field starts the oxygen anodization and these oxyanions combine with silicon to produce the silicon oxide, this minimum time required would be related with the formation rate of oxyanions at the silicon surface. In fact, the minimum time required to oxide the surface found by these authors in contact mode AFM (greater than 10,LLS) is consistent with this explanation and with the results we have obtained. The above explanation can also account for the following trends observed in Fig. 4: (i) the lateral dimensions of the modification do not depend on the oscillation amplitude for a given value of the bias voltage if this voltage is higher than Vth ; (ii) the lateral dimensions of the modification depend on the bias voltage; (iii) the threshold bias depends linearly on the oscillation amplitude. Case (i) can be simply explained if we realize that the maximum value of the electrical field is the same whatever the oscillation amplitude is. Thus, if the threshold electrical field is reached during the whole oscillation cycle, the extension of the modification should also be the same. In order to qualitatively explain cases (ii) and (iii) we have modelized the tip as a metallic sphere with a radius of 85 nm. After this, the spatial distribution of the electrical field on the surface is calculated, following the way proposed by Snow and Campbell7 and taking into account the average tip-to-sample distance. The behavior (iii) is immediately re- produced if we keep in mind that the tip radius is much larger than the average tip-to-sample distance, so that the (b) J. Appl. Phys., Vol. 78, No. 11, 1 December 1995 Pkez-Murano et al. 6799

20 Position 00 Surface ( 2 4 6 8 Voltage (V) 10 12 FIG. 5. Dependence of the modification radius as a function of the applied voltage. The squares correspond to the experimental data extracted from Fig. 4 and the solid line correspond to the modelization of the tip as an 85 nm radius metallic sphere separated 5 nm from the surface. In the modelization, the modification radius is evaiuated as the position on the surface where the electrical field has the same value for each bias. In the inset of the figure, is shown the value of the electrical field on the surface for bias voltages of 10, 8, 6, and 4 V as solid lines, and the condition of constant electrical field as the dashed line. variation of the maximum value of the electrical field on the surface with distance and bias follows the parallel plate approximation. For case (ii), the experimental data along with the modelization are shown in Fig. 5, where it is depicted the variation of the modification radius with the applied voltage. The squares correspond to the experimental data extracted from Fig. 4, and the solid line corresponds to the modelization. In this case, the modification radius is evaluated as the extension on the surface where the electrical field has a value greater than the threshold electrical field. It is assumed a tip to sample distance of 5 nm, to account for the native oxide and possible contamination and water layers. In the inset of the Fig. 5 it is shown the values of the electrical field on the surface for several bias voltages (10, 8, 6, and 4 V, represented by the solid lines). In addition, the value of the threshold electrical field which determines the lateral dimensions of the modification is shown by the dashed line. From the modelization, it is found that the value of the threshold electrical field is around 0.5 V/nm and that the minimum voltage to produce a modification is 2.2 V, which is in accordance with the experimental value obtained. We want to emphasize that the dependence of the threshold voltage with the average tip-to-sample distance is not a consequence of an increase of the time that the tip remains in contact with the surface. First, increasing the pulse duration does not have any appreciable effect on the voltage threshold dependence on the tip-to-sample distance (,keeping in mind that we have always used a pulse duration larger than the cantilever oscillation period). On the other hand, we have performed modifications with a constant oscillation amplitude and variable pulse duration t,, so that in this case the time that the tip is in contact with or very close to the surface can be varied while keeping the average tip to sample distance constant. Figure 6 shows modifications produced by pulses of 11 V and several values of t,, keeping the oscilla- FIG. 6. TMAFM image of Si(100) showing an array of modifications performed for different pulse durations t,(vahtes in milliseconds depicted above each dot). The oscillation amplitude and the voltage to perform the modification are 5.3 nm and 11 V, respectively. tion amplitude of 5.3 nm. The pulse duration in milliseconds is depicted above each modification. The diameter and height of the modification increase with the logarithm of tp. On the other hand, from Fig. 4 it is found that the threshold voltage depends linearly on the average tip-to-sample distance. Therefore, the parameter that governs Vti is only the tip-tosample distance, what confirms that the oxidation is produced not only during the time that the tip is in contact with the surface, but during the whole oscillation cycle. IV. CONCLUSIONS The dependences deduced from the images of Figs. 4 and 5 open new possibilities for the study of field-induced oxidation of silicon surfaces by STM and AFM. TMAFM offers a new parameter to play: the tip-to-sample distance, thus allowing the study of the modifications as a function of the electrical field between tip and sample. Additional advantages of performing the modification with TMA!?M are the reduction of the damage on the surface while scanning, a better characterization of the grown oxide than with any other technique and a better preservation of the tip and surface integrity, which implies that TMAFM can be used as a powerful tool for nanometer-scale lithography. As an example, in Fig. 7 we show lo-nm-diam modifications produced on a cleaved surface from an original Si(100) wafer. The integrity of tip and-sample is demonstrated because of the low surface roughness and the observation of an atomic step approximately 0.3 nm height. Further work in these directions is underway. In conclusion, the nanometer-scale modification of Si(100) surfaces has been demonstrated using tapping mode AFM. Two kinds of modifications can be produced: gold deposition from the tip and field-induced oxidation of the surface. The dependence of the threshold voltage necessary to oxidize the surface on the average tip-to-sample distance has been found, allowing to study the. dependence of the modification process on the electrical field. Finally, it has been shown that the modification can be better characterized by tapping mode AFM than by any other technique. 6800 J. Appl. Phys., Vol. 78, No. 11, 1 December 1995 Pbrez-Murano ef al.

.i.::; I ij., :c-.. ;~ 3oonm FIG. 7. TMAFM image of a silicon surface cleaved from a Si(lO0) wafer. The diameter of the modifications is 10 nm. The step height is 0.28 run. The modifications were produced by applying a 10 V pulse during 10 ms. ACKNOWLEDGMENTS The authors are grateful to Esteve Farres from de Centre National de Microelect&nica for the metallization of the AFM tips. We are indebted to the Serveis Cientifico-T&nics of the Universitat de Barcelona for equipment disponibility, and to the Nanotechnology Network financed by the Generaiitat de Catahmya. See, for example, the Proceedings of the NAN0 3 Conference. Published in J. Vat. Sci. Technol. B, May 1995. J. A. Dagata, J. Schneir, H. H. Harary, C. J. Evans, M. T. Postek, and J. Bennett, Appl. Phys. Lett. 56, 2001 (1990). 3N. Barniol, E Perez-Murano, and X. Aymerich, Appl. Phys. Lett. 61, 462 (1992). 4E. S. Snow, P. M. Campbell, and P. J. McMarr, Appl. Phys. Lett. 63, 749 (1993). l? Fay, R. T. Brockenbrough, G. Albeln, P. Scott, S. Agarwala, I. Adesida, and J. W. Lyding, Appl. Phys. Lett. 75, 7545 (1994). 6H. C. Day and D. R. Allee, Appl. Phys. Lett. 62, 2691 (1993). 7E. S. Snow and P. M. Campbell, Appl. Phys. Lett. 64, 1932 (1994). D. Wang, L. Tsau, and K. L. Wang, Appl. Phys. I&t. 65, 1415 (1994). L. Isa, D. Wang, and K. L. Wang, Appl. Phys. Lett. 64, 2133 (1994). E S Snow, P. M. Campbell, and B. V. Shanabrook, Appl. Phys. Lett. 63, 3488 (1993). J A. Dagata, J. Schneir, H. H. Harary, J. Bennett, and W. Tseng, J. Vat. Sci. Technol. B 9, 1384 (1991). S. C. Minne, H. T. Soh, Ph. Flueckiger, and C. E Quate, Appl. Phys. Lett. 66, 703 (1995). 13Q. Zhog, D. Inniss, K. Kjoller, and V. B. Ellings, Surf. Sci. Lett. 290, L688 (1993). 14Digital Instruments, Santa Barbara, California. t5c. A. J. Putman, K. 0. Van der Werf, B. G. De Groom N. E Van Hulst, and J. Greve, Appl. Phys. Lett. 64, 2454 (1994). 16Nanosensors, Germany. t7h. J. Mamin, S. Chiang, H. Birk, P. H. Guethner, and D. Rugar, 3. Vat. Sci. Technol. B 9, 1398 (1991). *R. Imura, H. Koyanagi, M. Miyamoto, A. Kikukawa, T. Shintani, and S. Hosaka, Microelectron. Eng. 27, 105 (1995). 19N Kramer, J. Jorritsma, H. Birk, and C. Schonenberger, Microelectron. Et&. 27, 47 (1995). OF. Perez-Murano, J. Servat, N. Barniol, P. Gorostiza, G. Abadal, X. Aymerich, and F. Sanz (unpublished). J. Appl. Phys., Vol. 78, No. 11, 1 December 1995 P&ez-Murano et al. 6801