Timers GT3F. GT3F Series True Power OFF Delay Timers. Phone: Fax: Web: -

Similar documents
Timers. GT3A Series Analog Timers. GT3A-1 GT3A-2 GT3A-3 GT3A-4,-5,-6 Operation Multi-mode Multi-mode with inputs (11 pins) Time Range

Timers. GT3A Series Analog Timers. GT3A-1 GT3A-2 GT3A-3 GT3A-4,-5,-6 Operation Multi-mode Multi-mode with inputs (11 pins) Time Range 13.

GT3W Series Dual Time Range Timers. CSA Certified File No.LR58183 LR96764 LR83814

Model Number Structure. Ordering Information. Solid-state Power OFF-delay Timer H3DE-H. Model Number Legend. List of Models

GT3D Series Digital Timers

For more information, please visit or call toll free at

Section. Timers. Selection Guide... G-2. Timing Diagrams Overview... G-4. W G RTE Series Analog Timers... G-8 Accessories... G-11 Dimensions...

No mark Time-limit SPDT (1c) A Time-limit DPDT (2c) B Time-limit SPDT (1c), Instantaneous SPDT (1c) S DIN W48 H48mm.

Solid-state Twin Timer

Timers GE1A. GE1A Series ON Delay Timers Single Function

GT5Y Series ON Delay Timers. UL, c-ul Listed File No. E V AC, 3A 30V DC, 3A 220V AC, 0.8A 30V DC, 1.5A 660VA AC 90W DC 176VA AC 45W DC

Timers. GT3A Series Analog Timers. GT3A-1 GT3A-2 GT3A-3 GT3A-4,-5,-6 Operation Multi-mode Multi-mode with inputs (11 pins) Time Range 13.

Solid-State Timer. ON-delay, Repeat cycle/signal OFF start, Repeat cycle/signal ON start, Signal ON/OFF-delay, Signal OFF-delay, and Interval

Solid-state Timer H3DE

OMRON. H3DE - Standard Timer. H3DE-G - Star-Delta Timer. H3DE-F - Twin Timer. H3DE-H - Power OFF- Delay Timer

ON-delay operation 8-pin round socket DPDT --- H3CA-8 H3CA-8 SPDT SPDT H3CA-8H H3CA-8H

Analog Timer TTL Series

38 Series - Relay interface modules A

Contents H3CR. DIN 48 x 48-mm Multifunctional Timer Series. Broad Line-up of H3CR Series H3CR-A. Solid-state Timer. Common to ALL Timers

38 Series - Relay interface modules A

Solid-state Timer H3CR. DIN 48 x 48-mm Multifunctional Timer Series. Broad Line-up of H3CR Series H3CR-A

3.5 mm contact pin pitch 1 Pole 12 A PCB direct or via socket

Enclosure rating. LED indicator with test button G2R-1-SNI G2R-2-SNI Unsealed Diode. LED indicator and diode with test button G2R-1-SNDI G2R-2-SNDI

RJ Series Slim Power Relays

Overtravel of 3.5 mm max. Power source DC D5C-1DS0 D5C-1DP0 D5C-1DA0 AC D5C-1AS0 D5C-1AP0 D5C-1AA0 Antenna only D5C-00S0 D5C-00P0 D5C-00A0

Bulletin 700-HX Multifunction Digital Timing Relay

OFF-delay time. 7.5 s. 15 s. 30 s. Main contacts Auxiliary contact Number of input channels Rated voltage Model Category

Solid-state Timer. Operation/resetting system Time-limit contact Time ranges Model

Multi-voltage Multi-function. Wiring diagram (without control signal)

3.5 mm contact pin pitch 1 Pole 12 A PCB direct or via socket

Solid-state Timer H3DE

Solid-state Timer H3DS

Timers RTE. RTE Series Analog Timers

Details on the New G2RS

Power PCB Relay. To Order: Select the part number and add the desired coil voltage rating (e.g., G6B-1114-US-DC6).

Solid-State Digital Counter H7AN

DIN48 SIZE ANALOG MULTI-RANGE CYCLIC TWIN TIMERS

Electronic timers CT-S range Selection and ordering details

GT3D Digital Timers. 100 to 240V AC (50/60Hz), 24V AC (50/60Hz)/24V DC

PCB Relay SPST-NO G6CU-1117P-US G6CU-1114P-US G6CU-1117C-US G6CU-1114C-US SPST-NO + SPST- G6CU-2117P-US G6CU-2114P-US G6CU-2117C-US G6CU-2114C-US

SPST-NO SPDT DPST-NO DPDT

G2RL-1A G2RL-1 G2RL-2A G2RL-2

PCB Relay. Ordering Information. SPST-NO Type Breaks 10-A Loads; SPST-NO + SPST-NC Type Breaks 8-A Load

Model Number Structure

IDEC RJ22 Series Slim Power Relays (Bifurcated Contacts)

G6C. Miniature High Capacity Relays with SPST-NO 10A and SPST-NO + SPST-NC 8A. Model Number Legend. Application Examples.

The power in relays and timers since Catalogue

2 Pole CO, 8 A Plug-in 2 CO (DPDT) 1 CO (SPDT) 8/15 16/25* 250/ /400 2,000 4, /0.5/ /0.5/ (5/5) 300 (10/5)

38 SERIES. Relay interface modules A. EMR Electromechanical Relays. Common features. SSR Solid State Relays. 6.

Features. UL Insulation. Sealed type washable 1A (SPNO) H H-1A-C 845H-1A-V 845H-1A-S. system approval Flux tight Sealed type

D7F. Detects Changes in Machine. Vibration. Vibration Sensor with Linear Output or Manual Setting. Ordering Information

Ratchet Relay. Ordering Information. Unique Ratchet Mechanism Assures Positive Alternate Transfer/Switching Operation. G4Q-jjjj

22 Series Relays. Technical Data...1. Specifications...2. Model Number Structure - Relays...3. Model Number Selection

Relays & Sockets. RF1V Force Guided Relays/SF1V Relay Sockets. Certification Organization/ File Number. UL/c-UL File No.

Multi-voltage Multi-function. BE: Off-delay with control signal BE: Off-delay with control signal CE: On- and off-delay with control signal

PCB Relay. --- G2R-1-SN --- G2R-2-SN LED indicator with test

Type Contact form Plug-in/solder Plug-in/solder PCB terminals Upper-mounting terminals terminals with plug-in/solder

PCB Relay. Contact form Terminal Single-side stable Single-winding latching Double-winding latching

Relays & Sockets. RH Series Compact Power Relays. Part Number Selection. Blade Terminal

Safety Relay Unit. OFF-delay time

SPST-NO SPDT DPST-NO DPDT

Detection of Incorrectly Set Work Press Position Confirmation Detection of Bent Drills. Press D5C

T ime Delay Relays General information

onlinecomponents.com

Modular timers A

83 Series - Modular timers 16 A. Features

Switching & Controls Timers

40 Series - Miniature P.C.B. Relays A

Technical Information General Purpose Relays

Relays & Sockets RU Series Universal Relays. With Latching or Momentary Lever. Standard (without lever) Key features:

PIR6WT-1Z interface - time relays

Classification Enclosure rating Contact form Contact material

Multi Function Timer with Free power, Compact size W38 H42mm

DIN48 SIZE MULTI-RANGE ANALOG TIMER. Protective construction. Time range IP65 IP50 IP selectable ranges 1s to 500h IP50 IP65 IP50

6mm Interface Relays RV8 Series

Relays & Sockets. RF2V 2-Pole Force Guided Relays/SJ Series Relay Sockets. UL/Recogntion File No. E55996 TÜV SÜD. EU Low Voltage Directive

Classification Enclosure rating Contact form Model Standard Flux protection SPST-NO G6RL-1A

G2RV-SL Slim I/O Relay will be discontinued February 2019

38 Series - Relay interface modules A. Features /

DPDT MY2N-D2 MY2IN-D2 --- (DC only) 4PDT MY4N-D2 MY4IN-D PDT (bifurcated) MY4ZN-D2 MY4ZIN-D2 --- With built-in CR

G5LE. Ordering Information. PCB Relay. A Cubic, Single-pole 10-A Power Relay J MODEL NUMBER LEGEND G5LE PCB Relay G5LE

И М. 2 24VAC 50/60Hz, 24-48VDC VAC 50/60Hz

General-purpose Relay

DIN 22.5/17.5 Size Lineup of A Wide Range of Measuring and Monitoring Relays. Model Number Structure

Ordering Information. PCB Relay G6RL. Model Number Legend: Low-profile power relay with maximum switching of 10 A

20 Series Power Relays

Control Relays and Timers

RU Series Universal Relays

Contact Ag + Au-clad AgPd + Au-clad. General purpose DPDT G6AU-274P-ST-US G6AU-234P-ST-US 4PDT G6AU-474P-ST-US G6AU-434P-ST-US

62 Series - Power relays 16 A. Features / /

Classification Contact form Contact type Contact material Enclosure Rating Model Standard DPDT Bifurcated crossbar Ag (Au alloy) Fully sealed G5V-2

Quick Reference Guide

Relay interface modules A

Features. Measuring and Monitoring Relays K8AB Series. Cut by 50% Industry First! Two SPDT Outputs Available in New Models DIN Sized at 22.

Model Number Structure

OMRON MK-I / -S RELAY

83 SERIES. 83 Series - Modular timers A. Features

1-Phase True RMS AC/DC Over and Under Current Types DIC01, PIC01

GENERAL PURPOSE RELAYS

38 Series - Relay Interface Modules A

Transcription:

Key features: True power OFF-delay up to minutes No external control switch necessary Available with reset inputs Mountable in sockets or flush panel Specifications Operation UL, c-ul Listed File No. E55996 Series True OFF Delay -1 True power OFF-delay Time Range 0.1 seconds to 600 seconds Rated Voltage Contact Rating 50V AC/30V DC, 5A (resistive load) 0 to 40V AC, 50/60Hz 4V AC/DC - 50V AC/30V DC, 3A (resistive load) Contact Form SPDT DPDT Minimum Application Time 1 second Voltage Tolerance Repeat Error Voltage Error Temperature Error Setting Error Insulation Resistance Dielectric Strength Consumption Mechanical Life Electrical Life AF0: 0 to 40V AC AD4: 1.6 to 6.4VDC, 0.4 to 6.4VAC ±0.%, ± msec ±0.%, ± msec ±0.%, ± msec ±% maximum 0MW minimum Between power and output terminals:,000v AC, 1 minute (SPDT) 1,500V AC, 1 minute (DPDT) Between contacts on different poles: 1,000V AC, 1 minute (DPDT) Between contacts of the same pole: 750V AC, 1 minute AF0: 3.7VA (00V AC, 60Hz) AD4: 0.8W (DC), 1.VA (AC) 0,000,000 operations minimum 0,000 operations minimum Vibration Resistance 0m/sec (approximate G) Shock Resistance Operating Temperature Storage Temperature Operating Humidity Operating extremes: 0 m/sec (approximate G) Damage limits: 500 m/sec (approximate 50G) to +50 C 30 to +80 C 45 to 85% RH Weight (approximate) 77g 79g 1. An inrush current flows during the minimum power application time. AF0: approximate 0.4A, AD4: approximate 1.A. does not read the preset time range shown on the knob after power is turned off. Note that minimizing the preset time, by turning the knob to zero, does not shorten the delay time after power is removed. Switches & Pilot Lights Signaling Lights Relays & Sockets Contactors Blocks Circuit Breakers

Switches & Pilot Lights Signaling Lights Relays & Sockets Mode of Operation True- OFF-delay Rated Voltage Code AF0: 0 to 40VAC (50/60Hz) AD4: 4V AC/DC Part Numbering List Time Range Output Contact Optional 0.1 seconds to 600 seconds Optional reset input resets the contact to the OFF state before time out. -1 Timing Diagrams -1 (8-pin) Complete Part Number 8-Pin 11-Pin 50V AC, 5A, -1AF0-1EAF0 Delayed SPDT 30V DC, 5A (resistive load) -1AD4-1EAD4 50V AC, 3A, None (8p) -AF0 -EAF0 Delayed DPDT 30V DC, 3A (resistive load) (11p) -AD4 -EAD4 Timing Diagrams/Schematics Delayed SPDT Output, with -1E (11-pin) Contactors Item Number Operation - 7 (8p) - (11p) Delayed Contact Indicator (8p) 6-7 (11p) 5-8 (8p) (11p) 6-8 (8p) 1-3 (11p) ON or L T = Set time Ta = Shorter than set time Ts = 1 Second Tr = Minimum Application Time -1: 1 Second 1. For time ranges, see page page 854.. For sockets and accessory part numbers, see page page 860. 3. When power is applied, the NO output contact closes. When power is removed, the timing period begins. When time has elapsed, the NO contact opens. 4. For the timing diagram overview, see page page 83. Circuit Breakers Blocks

- Timing Diagrams 8-Pin Type 11-Pin Type (-) - (8-pin) m n l o k p j q (+) Item Number Operation - 7 Delayed Contact Indicator 5-8 1-3 6-8 Delayed DPDT Output T Tr T (Contact ) Item Number Operation - 6-7 (11p) ON or L Delayed 8-11 Contact 1-3 9-11 Indicator -E (11-pin) m no p qr m no p qr l l (-) s (+) (-) s (+) k j (Transistor ) k j When power is applied, the NO contact closes. When power is removed, the timing period begins. When time has elapsed, the NO contact opens. Optional reset input will return contacts to original state before time elapses. T = Set time Ta = Shorter than set time Ts = 1 Second Tr = Minimum Application Time -1: 1 Second Item Number Operation - 6-7 (11p) ON or L Delayed 8-11 Contact 1-3 9-11 Indicator Switches & Pilot Lights Signaling Lights Relays & Sockets Contactors Blocks Circuit Breakers

Switches & Pilot Lights Instructions: Setting Series Indicator l Setting Knob Signaling Lights j Dial Selector 0-1, 0-3, 0-6, 0-18, 0-60 k Time Range Selector 1S, S Relays & Sockets Step 1 Desired Operation Selection Remarks Select a time range that contains the desired period of time. Base Time Ranges j Dial Selector k Time Range Selector 0.1s to 1s 0 to 1 0.1s to 3s 0 to 3 0.1s to 6s 0 to 6 0.1s to s 0 to 1 0.3s to 30 0 to 3 0.6s to 60 0 to 6 1.8s to 180s 0 to 18 6s to 600s 0 to 60 Step 1s s Time range can be selected from 1S and S using a flat screwdriver and five different dials of 0 to 1, 0 to 3, 0 to 6, 0 to 18, and 0 to 60 are displayed in the six windows by turning the Dial Selector, allowing for selecting the best suited scale. Note that the switch does not turn infinitely. Setting Examples: Remarks The set time is selected by turning the l Setting Knob. 1. When the Setting Knob l is set at.5, with Dial Selector j 0 to 3 and Time Range Selector k 1S selected, then the set time is.5 seconds.. When the Setting Knob l is set at 5.0, with Dial Selector j 0 to 60 and Time Range Selector k S selected, then the set time is 500 seconds. Circuit Breakers Blocks Contactors

s of Instructions: Wiring s To avoid electric shock, do not touch the input signal terminal during power voltage application. Never apply the input signals to two or more timers using the same contact or transistor. [Incorrect] Contact or Transistor GT3 Series Timer [correct] In a transistor circuit for controlling input signals, with its primary and secondary power circuits isolated, do not ground the secondary circuit. Circuit GT3 Series Timer Rectifier Circuit Insulating Transformer On the timers, connect the input signals to terminal No.1 and 4 only on the 8-pin type; connect the input signals to terminal No. 6 and 7 only on the 11-pin type. Never apply voltage to other terminals; otherwise, the internal circuit may be damaged. signal lines must be made as short as possible and installed away from power cables and power lines. Use shielded wires or a separate conduit for input wiring. The, consisting of a high-impedance circuit, may not be reset due to the influence of an inductive voltage or residual voltage caused by a leakage current. If not reset, connect an RC filter or bleeder resistor between power terminals so that the voltage between power terminals can be reduced to less than 15% of the rated voltage. Switches & Pilot Lights Signaling Lights Relays & Sockets Contactors Blocks Circuit Breakers