ZCS BRIDGELESS BOOST PFC RECTIFIER Anna Joy 1, Neena Mani 2, Acy M Kottalil 3 1 PG student,

Similar documents
Double Boost SEPIC AC-DC Converter

Performance Improvement of Bridgeless Cuk Converter Using Hysteresis Controller

Design and Simulation of New Efficient Bridgeless AC- DC CUK Rectifier for PFC Application

Linear Transformer based Sepic Converter with Ripple Free Output for Wide Input Range Applications

Simulation Of Bridgeless Resonant Pseudo boost PFC Rectifier

Single Phase Bridgeless SEPIC Converter with High Power Factor

New Efficient Bridgeless Cuk Rectifiers for PFC Application on d.c machine

International Journal of Engineering Research and General Science Volume 3, Issue 4, July-August, 2015 ISSN

AN EFFICIENT CLOSED LOOP CONTROLLED BRIDGELESS CUK RECTIFIER FOR PFC APPLICATIONS

A New Closed Loop AC-DC Pseudo boost Based Converter System for CFL

Bridgeless Cuk Power Factor Corrector with Regulated Output Voltage

Comparative Analysis of Bridgeless CUK and SEPIC Converter

International Journal of Scientific & Engineering Research, Volume 5, Issue 3, March-2014 ISSN

A BRIDGELESS CUK CONVERTER BASED INDUCTION MOTOR DRIVE FOR PFC APPLICATIONS

Analysis of Correction of Power Factor by Single Inductor Three-Level Bridgeless Boost Converter

HIGH EFFICIENCY BRIDGELESS PWM CUK CONVERTER WITH SOFT SWITCHING TECHNIQUE

High Power Factor Bridgeless SEPIC Rectifier for Drive Applications

Soft-Switching Two-Switch Resonant Ac-Dc Converter

A HIGH STEP UP RESONANT BOOST CONVERTER USING ZCS WITH PUSH-PULL TOPOLOGY

A Unique SEPIC converter based Power Factor Correction method with a DCM Detection Technique

DESIGN OF BRIDGELESS HIGH-POWER-FACTOR BUCK-CONVERTER OPERATING IN DISCONTINUOUS CAPACITOR VOLTAGE MODE.

Modified SEPIC PFC Converter for Improved Power Factor and Low Harmonic Distortion

Controlled Single Switch Step down AC/DC Converter without Transformer

Design and Implementation of the Bridgeless AC-DC Adapter for DC Power Applications

A Voltage Quadruple DC-DC Converter with PFC

Implementation of Bridgeless Cuk Power Factor Corrector with Positive Output Voltage

Simulation and Performance Evaluation of Closed Loop Pi and Pid Controlled Sepic Converter Systems

AN EXPERIMENTAL INVESTIGATION OF PFC BLDC MOTOR DRIVE USING BRIDGELESS CUK DERIVED CONVERTER

3292 IEEE TRANSACTIONS ON POWER ELECTRONICS, VOL. 27, NO. 7, JULY 2012

CHAPTER 6 BRIDGELESS PFC CUK CONVERTER FED PMBLDC MOTOR

Student Department of EEE (M.E-PED), 2 Assitant Professor of EEE Selvam College of Technology Namakkal, India

An Adjustable-Speed PFC Bridgeless Single Switch SEPIC Converter-Fed BLDC Motor

SINGLE STAGE SINGLE SWITCH AC-DC STEP DOWN CONVERTER WITHOUT TRANSFORMER

A Novel Bridgeless Single-Stage Half-Bridge AC/DC Converter

Webpage: Volume 3, Issue IV, April 2015 ISSN

A NOVEL SOFT-SWITCHING BUCK CONVERTER WITH COUPLED INDUCTOR

Bridgeless High Power Factor Buck Converter with Controlled Boost Converter

Closed Loop Control of Bridgeless Cuk Converter Using Fuzzy Logic Controller for PFC Applications

Implementation Of Bl-Luo Converter Using FPGA

Power Factor Corrected Single Stage AC-DC Full Bridge Resonant Converter

A New Single Switch Bridgeless SEPIC PFC Converter with Low Cost, Low THD and High PF

ZVT Buck Converter with Synchronous Rectifier

I. INTRODUCTION. 10

Push-Pull Quasi Resonant Converter Techniques used for Boost Power Factor Corrector

High Frequency Soft Switching Of PWM Boost Converter Using Auxiliary Resonant Circuit

SIMPLIFICATION OF HORMONICS AND ENHANCEMENT OF POWERFACTOR BY USING BUCK PFC CONVERTER IN NON LINEAR LOADS

Improved Power Quality Bridgeless Isolated Cuk Converter Fed BLDC Motor Drive

Single Phase Cuk Rectifier To Get Positive Output Voltage And Reduced Total Harmonic Distortion.

ZERO VOLTAGE TRANSITION SYNCHRONOUS RECTIFIER BUCK CONVERTER

BRIDGELESS SEPIC CONVERTER FOR POWER FACTOR IMPROVEMENT

Magnetic Coupled Sepic Rectifier with Voltage Multiplier using PID Conroller for SMPS

SCIENCE & TECHNOLOGY

Power quality improvement and ripple cancellation in zeta converters

Narasimharaju. Balaraju *1, B.Venkateswarlu *2

Novel Passive Snubber Suitable for Three-Phase Single-Stage PFC Based on an Isolated Full-Bridge Boost Topology

An Interleaved Single-Stage Fly Back AC-DC Converter for Outdoor LED Lighting Systems

Power Factor Corrected Zeta Converter Based Switched Mode Power Supply

Analysis of Bridgeless SEPIC Converter with Minimum Component Stress and Conduction Losses for the Speed Control of Dc Motor

Integration of Two Flyback Converters at Input PFC Stage for Lighting Applications

Comparative Analysis of Power Factor Correction Techniques for AC/DC Converter at Various Loads

BLDC Motor Speed Control and PFC Using Isolated Zeta Converter

Integrated Buck-Buck-Boost AC/DC Converter

ZVS IMPLEMENTATION IN INTERLEAVED BOOST RECTIFIER

Controlled Transformerless Step-Down Single Stage AC/ DC Converter

Study of Power Factor Correction in Single Phase AC-DC Converter

ADVANCES in NATURAL and APPLIED SCIENCES

A Predictive Control Strategy for Power Factor Correction

A CONTROLLED SINGLE-PHASE SERIES RESONANT AC CHOPPER

Bridgeless Buck Converter with Average Current Mode control for Power Factor Correction and Wide Input Voltage variation

A Switched Capacitor Based Active Z-Network Boost Converter

PWM Switched Double Stage Buck Boost Converter with LC Filter for LED Lighting Applications

An Efficient Bridge-Less Power Factor Correction Tapped Inductor based SEPIC converter For BLDC Motor Application

Bidirectional DC-DC Converter Using Resonant PWM Technique

Single Phase Induction Motor Drive using Modified SEPIC Converter and Three Phase Inverter

An Investigation of Power Converters Fed BLDC Motor for Adjustable Speed

INTERNATIONAL JOURNAL OF ELECTRICAL ENGINEERING & TECHNOLOGY (IJEET)

CHAPTER 2 A SERIES PARALLEL RESONANT CONVERTER WITH OPEN LOOP CONTROL

A Photovoltaic Based Dual Output SEPIC- Cuk Converter for Led Driver Applications

A Modified Single-Phase Quasi z source converter

THE converter usually employed for single-phase power

ZCS-PWM Converter for Reducing Switching Losses

A New Quadratic Boost Converter with PFC Applications

A Power Factor Corrected Bridgeless Type III Cuk Derived Converter fed BLDC Motor Drive

A Merged Interleaved Flyback PFC Converter with Active Clamp and ZVZCS

A New Phase Shifted Converter using Soft Switching Feature for Low Power Applications

PERFORMANCE IMPROVEMENT OF CEILING FAN MOTOR USING VARIABLE FREQUENCY DRIVE WITH SEPIC CONVERTER

A Non-Linear Controller Based On Discrete Energy Function for An AC/DC SEPIC PFC Converter

A HIGHLY EFFICIENT ISOLATED DC-DC BOOST CONVERTER

IOSR Journal of Electrical and Electronics Engineering (IOSR-JEEE) e-issn: ,p-ISSN: , PP

One-Cycle Control of Interleaved Buck Converter with Improved Step- Down Conversion Ratio

International Journal of Engineering Science Invention Research & Development; Vol. II Issue VIII February e-issn:

A THREE-PHASE HIGH POWER FACTOR TWO-SWITCH BUCK- TYPE CONVERTER

An Asymmetrical Dc-Dc Converter with a High Voltage Gain

A HIGH RELIABILITY SINGLE-PHASE BOOST RECTIFIER SYSTEM FOR DIFFERENT LOAD VARIATIONS. Prasanna Srikanth Polisetty

Implementation of Single Stage Three Level Power Factor Correction AC-DC Converter with Phase Shift Modulation

A Novel Single-Stage Push Pull Electronic Ballast With High Input Power Factor

Non-isolated DC-DC Converter with Soft-Switching Technique for Non-linear System K.Balakrishnanet al.,

PSIM Simulation of a Buck Boost DC-DC Converter with Wide Conversion Range

A Feedback Resonant LED Driver with Capacitive Power Transfer for Lighting Applications

International Journal of Current Research and Modern Education (IJCRME) ISSN (Online): & Impact Factor: Special Issue, NCFTCCPS -

Transcription:

ZCS BRIDGELESS BOOST PFC RECTIFIER Anna Joy 1, Neena Mani 2, Acy M Kottalil 3 1 PG student, annajoykandathil@gmail.com,8111948255 Abstract A new bridgeless single-phase ac dc converter with a natural power factor correction (PFC) is proposed. Compared with existing single-phase bridgeless topologies, the proposed topology has the merits of less component counts. The absence of an input diode bridge and less conduction losses; hence, improved thermal management compared to existing PFC rectifiers is obtained. The proposed topology is designed to work in resonant mode to achieve an automatic PFC close to unity in a simple and effective manner. The resonant mode operation gives additional advantages such as zero-current turn-on in the active power switches. Keywords Bridgeless AC-DC Converters, Power-factor correction, Resonant power conversion, Zero Current Switching, Total harmonic distortion, Pseudo boost converters, Voltage gain INTRODUCTION Power factor correction (PFC) techniques are becoming necessary for many types of electronic equipment especially in the telecommunication and computer industries to meet harmonic regulations. Also, higher power density and lower system cost are always very desirable features, especially for low power supplies. Most of the PFC rectifiers utilize a boost or buck-boost topology converter at their front end due to its high power factor (PF) capability. However, a conventional PFC scheme has lower efficiency due to significant losses in the diode bridge. During each switching cycle interval, the current flows through three power semiconductor devices. The forward voltage-drop across the bridge diodes degrades the converter efficiency, especially at low-line input voltage [1].Pseudo boost converters are thus named because the voltage transfer ratio of pseudo boost converter is similar to that of conventional boost converter, with no relation to the resonant parameters and switching frequency. A bridgeless PFC circuit allows the current to flow through a minimum number of switching devices compared to the conventional PFC circuit. Accordingly, the converters conduction losses can be significantly reduced, and higher efficiency and lower cost can be obtained. However, most of the previous proposed bridgeless PFC converters have at least one of the following drawbacks: 1) high components count, 2) Components are not fully utilized over whole ac-line cycle, 3) complex control, 4) dc output voltage is always higher than the peak input voltage, 5) lack of galvanic isolation, and 6) due to the floating ground, some topologies require additional diodes and/or capacitors to minimize EMI. In order to overcome most of these problems, an interesting topology has been introduced with reduced component count. However, the proposed topology in still suffers from having at least two semiconductors in the current conduction path during each switching cycle. In [4], a zero current switch topology is presented. This topology has reduced-component count; however, the load is floating with respect to the input. A novel low count topology has been introduced in [5]. The proposed topology has low-component count with an input stage similar to a boost converter. Here a new bridgeless PFC circuit based on the modified boost converter is introduced and presented Compared with existing single phase bridgeless topologies. The proposed topology has low component count, a single control signal, and non-isolating output. Since the topology operates in discontinuous conduction mode, the proposed converter is intended for low power applications. The converter components are fully utilized during the positive and negative ac-line cycle [9]. Pseudo naming comes because this converters have voltage transformation ratio same as that of conventional boost converter, but it is independent of resonant parameters and duty ratio. Voltage conversion ratio can be further increased by quasi resonant technique [10]. BRIDGELESS RESONANT PSEUDO-BOOST PFC RECTIFIER Introduction The Bridgeless Resonant Pseudo boost PFC Converter circuitry consists of two MOSFET switches, two power diodes, resonant inductor and capacitor. At input side, LC filter is provided. The Bridgeless Resonant Pseudo boost PFC Rectifiers are designed to operate in discontinuous-conduction mode (DCM) during the switch turn-on interval and in resonant mode during the switch turn off intervals. As a result, the switch current stress is similar to the conventional DCM PFC converter, while the switch voltage stress is higher [1]. Moreover, the two power switches Q1 and Q2 can be driven by the same control signal, which significantly simplifies the control circuitry. Basic circuit of Bridgeless Resonant Pseudo boost PFC Rectifier is shown in Fig 3.1. Referring to Figure 2.1, the switching conduction sequences are as follows: 97 www.ijergs.org

Figure 2.1: The Bridgeless Resonant Pseudo boost PFC Rectifier During positive ac-line cycle, Q 1, D Q2, D 2, D 1,X (all switches are off); and 2) during negative ac-line cycle, Q 2,D Q1,D 1,D 2,X. On the other hand, the switching conduction sequences for the converter are as follows: 1) during positive ac-line cycle, Q 1, D Q2 D 1, D 2, X and 2) during negative ac-line cycle, Q 2, D Q1, D 2, D 1,X. Thus, during each switching period T S, the current path goes through only two or one semiconductor devices instead of three. As a result, the total conduction losses of the semiconductor devices will be considerably lower compared to the conventional bridgeless PFC converters. In addition, the following assumptions are made: input voltage is pure sinusoidal, ideal lossless components, the switching frequency (fs) is much higher than the ac line frequency (f L ), and the output capacitor C 0 is large enough such that the output voltage can be considered constant over the whole line period. Based on these assumptions, the circuit operations in one switching period Ts in a positive ac-line cycle can be divided into four distinct topological stages. From simulation results, for an input voltage 110 V, fs (switching frequency) = 50 khz, simulation is performed in MATLAB Ra2010. The parameters used includes L f = 1mH and C f = 1 µf, L 1 = 100 µh, C 1 = 65nF and R L = 500. Output voltage is obtained as 242V and output current as 0.4A. Output voltage step up. Switching frequency used is 50 khz. Power factor is obtained near unity, 0.92 and Total Harmonic Distortion is only 2%.Output power is nearer to 100 W, so it is used only for low power application. Working Principle Resonant Pseudo boost PFC Rectifiers are designed to operate in discontinuous- conduction mode (DCM) during the switch turnon interval and in resonant mode during the switch turn off intervals. As a result, the switch current stress is similar to the conventional DCM PFC converter, while the switch voltage stress is higher. Moreover, the two power switches Q 1 and Q 2 can be driven by the same control signal, which significantly simplifies the control circuitry. However, an isolated gate drive is required for the power switch Q 1. Table I: Tabulation of simulated results Input Voltage 110 V Input Current 1.5 A Input Power Factor 0.92 THD 2% Output Voltage 242 V Output Current 0.4 A ZCS BRIDGELESS BOOST PFC RECTIFIER For further improving voltage conversion ratio of conventional boost converters a new converter can be designed. An alternative approach to soft switching in modified boost converters is to use quasi-resonant (QR) techniques that can be cheaply implemented by using only a few passive components. This converter can operate with soft-switching and PFC in low line applications. It is 98 www.ijergs.org

economical because it requires only two active switches and two diodes for the main power circuit and a few passive components for soft switching. ZCS bridgelss boost PFC rectifiers are shown in fig 3.1. Figure 3.1: ZCS Bridgeless boost PFC Rectifier Operational modes: Stage 1: This stage starts when the switch Q 1 is turned-on. The body Diode of Q 2 is forward biased by the inductor current I L1. Diodes are reverse biased by the voltage across C. In this stage, the current through inductor L 1 increases linearly with the input voltage, while the voltage across capacitor C 1 remains constant at voltage V X. Figure 2.1: Mode 1 of ZCS Bridgeless boost PFC Rectifier 99 www.ijergs.org

Stage 2: This stage starts when switch Q 1 is turned OFF and diode D 1 is turned ON simultaneously providing a path for the inductor currents I L1.As a result, diode D 2 remains reverse biased during this interval. The series tank consisting of L 1 and C 1 are excited by the input voltage V AC. The stage ends when the resonant current I L1 reaches zero. During this stage, capacitor C is charged until it reaches a peak value as shown in Figure 2.2 Figure 2.2: Mode 2 of ZCS Bridgeless boost PFC Rectifier Stage 3: During this stage diode D 1 is forward biased to provide a path during the negative cycle of the resonating inductor current I L1. This stage ends when the inductor current reaches zero. Thus, during this stage diode D 2 is switched ON under zero current conditions. Assuming the constant input voltage over a switching period, the capacitor is discharged until it reaches a voltage V X. Figure 2.3: Mode 3 of ZCS Bridgeless boost PFC Rectifier Stage 4: During this stage all switches are in their off-state. The inductor current is zero, while the capacitor voltage remains constant (V X ). It shall be noted that for this converter to operate as specified, the length of this stage must be greater than or equal to zero. 100 www.ijergs.org

Figure 2.4: Mode 4 of ZCS Bridgeless boost PFC Rectifier DESIGN OF COMPONENTS Design procedure of this converter is explained with the following specifications. Input Voltage, Vin =110 V Output Voltage,Vo =275 V Duty Ratio, D = 40 % Power Factor, pf =0.98 Switching Frequency f s =50 khz In order to perform the analysis and derive equations independent of any particular parameter, all equations derived in this paper are normalized using the following base quantities: Base voltage = Output voltage, V 0 Base Impedance = Z 0 = Base Current = Base Frequency = To ensure DCM operation, normalised switching frequency, F= The values of circuit components are calculated as follows: 1. Voltage Conversion Ratio, M = = 2.4 2. Critical Inductance, ( ) 3. Resonant Capacitance, = 65nF SIMULATION MODEL AND RESULTS 101 www.ijergs.org

For an input voltage 110 V, fs (switching frequency) = 50 khz, simulation is performed in MATLAB Ra2010. The parameters used includes L f = 1mH and C f = 1 µf, L 1 = 100 µh, C 1 = 65nF and R L = 500. Fig 4.1 shows the Simulink model of a ZCS Bridgeless boost PFC Rectifier. Figure 4.1: Simulink Model of ZCS bridgeless boost PFC Rectifier For input voltage 110 V and input current 1.5A, output voltage is obtained as 274 V. Switching frequency used is 50 khz. Power factor is obtained near unity, 0.99 and Total Harmonic Distortion is only 1%.Output power is nearer to 100 W, so it is used only for low power application. Power factor correction is observed from the input voltage and current waveforms, these are in phase. PF is measured as 0.92. Switching frequency is taken as 50 khz and duty ratio 50%. Discontinuous conduction mode is operated. 102 www.ijergs.org

Fig 4.3: Switching Pulses Fig 4.4: (a) Inductor Current (b) Capacitor Voltage Fig 4.5: Voltage and Current across the switch Fig 4.6: (a) Output Voltage of ZCS bridgeless boost PFC rectifier 103 www.ijergs.org

For input voltage 110 V, output voltage boost upto 274 V. Voltage conversion ratio is increased to 2.4 where less than 2 for conventional type. Zero Current switching can be observed from the fig 4.5. ZCS Bridgeless boost PFC rectifier gives high step up conversion and high input power factor 0.99. Total harmonic distortion is only 1 to 2%. Table II: Tabulation of simulated results Input Voltage 110 V Input Power factor 0.99 THD 0.012 Output Voltage 274 V Voltage Gain 2.4 CONCLUSIONS A new AC to DC converter with low component count and its topology derivation have been presented. The components of this topology are fully utilized over the whole line cycle. The two power switches in the proposed topology can be driven by the same control signal, which significantly simplifies the control circuitry. Voltage transfer ratios of ZCS bridgeless boost PFC rectifier is greater than conventional boost converters. Analysis, component stresses, design constraints, and simulation results of the converter have been presented. For an input voltage 110 V, switching frequency is 50 khz. Output voltage is obtained as 274 V with high input power factor 0.99 and less THD(1-2%).Output Power is nearer to 100 W, so it is used only for low power applications. simulation is performed in MATLAB Ra2010 REFERENCES: [1] Abbas A. Fardoun, Esam H. Ismail, Mustafa A. Al-Sa_ar and Ahmad J. Sabzali, A Bridgeless Resonant Pseudoboost PFC Rectifer IEEE Trans. Power Electron., vol. 29, no.11, pp. 384397, Nov 2014. [2] Manfred Reddig, Dr. Wenqi Zhou, True Bridgeless PFC - Stages with Advanced Current Measuring Circuit, IEEE Trans.Power Electron., Dec. 2011. [3] Fellipe S. Garcia, Jos A. Pomilio, and Giorgio Spiazzi, Modeling and Control Design of the Interleaved Double Dual Boost Converter, Trans.Power Electron., vol. 24, no. 12, pp. 28862896, Dec. 2011. [4] K. Mino, H. Matsumoto, S. Fujita, Y. Nemoto, D. Kawasaki, R. Yamada, and N. Tawada Novel Bridgeless PFC Converters with Low Inrush Current Stress and High Effciency," International Power Electronics Conference., Feb.2010. [5] M. Mahdavi, H. Farzanehfard, New Bridgeless PFC Converter with Reduced Components,, International Conference on Electronic Devices, Systems and Applications,2011. [6] J. Marcos Alonso,Juan Via, David Gacio Vaquero, Gilberto Martnez, and Ren Osorio, Analysis and Design of the Integrated Double Buck Boost Converter as a High-Power-Factor Driver for Power-LED Lamps,IEEE Trans.Industrial Electron.,vol.59, no.4, april 2012. [7] Dylan Dah-Chuan Lu and Wenfei Wang Bridgeless Power Factor Correction Circuits with Voltage-Doubler Con_guration,, IEEE PEDS. Ind. Electron., Dec 2011. [8] W.-Y. Choi, J.-M. Kwon, B.H. Kwon, Bridgeless dual-boost rectifier with reduced diode reverse-recovery problems for powerfactor correction, IET power electronics, Vol. 1, No. 2, pp. 194202, october 2007. [9] [9] Bin Su and Zhengyu Lu, An Interleaved Totem-Pole Boost Bridgeless Recti_er With Reduced Reverse-Recovery Problems For Power Factor Correction,IEEE Transactions On Power Electronics, Vol. 25, No.6, June 2010. [10] Gerry Moschopoulose, Praveen K Jain, A Novel single-phase soft switched rectifier with unity power factor and minimal Component count, IEEE Transactions On Industrial Electronics,Vol. 51, No.3, June, 2004 [11] Mohammad Mahdavi, Hosein Farzanehfard, Bridgeless SEPIC PFC Rectifer With Reduced Components and Conduction Losses, IEEE Transactions On Power Electronics,Vol. 58, No.9, September 2011. [12] T. Nussbaumer, K. Raggl, and J. W. Kolar, Design guidelines for interleaved single-phase boost PFC circuits, IEEE Trans. Power Electron.,vol. 56, no. 7, pp. 2559 2573, Jul. 2009. 104 www.ijergs.org