TRAINING OVERVIEW EDUCATION IS POWER. HIGH V O L T A G E T E S T S OLUTION S. reliable. precision.

Similar documents
CABLE FAULT LOCATING APPLICATION GUIDE. HIGH V O L T A G E T E S T S OLUTION S. reliable. precision.

GENERATOR TESTING APPLICATION GUIDE. reliable. precision.

Automatic Transformer Winding Analyser

TTR2796. Fully Automated Three Phase 250V Transformer Turns Ratio Meter FEATURES AND BENEFITS APPLICATIONS

Fully automated three phase 250V Transformer Turns Ratio Meter

TMS 580. Transformer Loss Measuring System FEATURES BENEFITS APPLICATIONS

KIT 4.0 HIGH VOLTAGE CONSTRUCTION KIT. reliable. precision. HIGH V O L T A G E T E S T S OLUTION S

700 Series AC Dielectric Test Sets

H V T E S T S O L U T I O N S PA RT N E RS F O R H V & E M C

portable affordable CDS Series Cable Fault Locators Thumpers - Surge Generators

HVI - The World s Source For High Voltage Test Equipment

TD-100. HAEFELY HIPOTRONICS Technical Document

Specialists in HV and MV test and diagnostics. Testing in Substations

SG A. Impulse Voltage Test System, kv / kj APPLICATION

H306 Series. AC/DC Benchtop Hipot Testers & Megohmmeter FEATURES BENEFITS APPLICATIONS

Evaluation and Limitations of Corona Discharge Measurements An Application Point of View

TD-106. HAEFELY HIPOTRONICS Technical Document. Partial Discharge Pulse Shape Analysis to Discriminate Near and Far End Failures for Cable Location

MIDAS 2881 / 2881G. Mobile Insulation Diagnosis & Analysing System

AC Dielectric Test Sets

MEDIUM & HIGH VOLTAGE

Mitigating Murphy s Law While Test. Frédéric Dollinger

USING DAMPED AC VOLTAGES

WIRE AND CABLE ENGINEERING GUIDE

HiAS TM 744 HIGHEST RESOLUTION IMPULSE ANALYZING SYSTEM

SAMPLE. Determining the health of your power transformer begins with Transformer Clinic s SAMPLE testing programs.

The importance of partial discharge testing throughout the development and operation of power transformers

Condition Assessment of High Voltage Insulation in Power System Equipment. R.E. James and Q. Su. The Institution of Engineering and Technology

MONTRANO. Continuous monitoring system for power transformers

Advanced Diagnostic Testing Services. Provides detailed and reliable results

Three-Phase Transformer Test Systems

TRANSFORMER OPERATIONAL. Principles, Selection & Troubleshooting

Discipline Electrical Testing Issue Date Certificate Number T-2837 Valid Until Last Amended on - Page 1 of 6 LOCATION 1

ELECTRICAL EQUIPMENT. Inspection. H.H. Sheik Sultan Tower (0) Floor Corniche Street Abu Dhabi U.A.E

Cable fault location. The shortcut to locating a fault

EQUIPMENT AND MOBILE LABORATORIES FOR NDT AND DIAGNOSTICS OF UNDERGROUND COMMUNICATION LINES.

MIT510/2, MIT520/2 and MIT1020/2

Modular Partial Discharge (PD) & Radio Interference Voltage (RIV) Detector

Field Measurement of Transmission Cable Dissipation Factor

Primary Test Manager (PTM) Testing and management software for primary assets

EE059: Transformer Operation, Maintenance, Diagnosis & Testing

Simultaneous Partial Discharge and Tan Delta Measurements: New Technology in Cable Diagnostics

Error vs. Uncertainty Historical Perspective

THE ELECTROM itig II MOTOR TESTER AND WINDING ANALYZER

Hands-On Transformer Testing and Maintenance

TRANSFORMER OPERATIONAL PRINCIPLES, SELECTION & TROUBLESHOOTING

IDAX 300 Insulation Diagnostic Analyzer. Dielectric Frequency Response Also known as: Frequency Domain Spectroscopy

HVA SERIES VLF TEST SETS. Hipot Testers HVA Series for VLF (0.1 Hz) testing of MV and HV cables.

MV Power Cable Diagnostics by Frequency Domain Spectroscopy. Peter Werelius Programma Electric AB

Electrical Equipment Condition Assessment

Insulating oil testing

About us. Vision. To lead our field in innovation, quality and customer service.

Test systems made by SebaKMT. Don t stress over tests! SebaKMT has the right answers: reliability, speed, economy.

WESTERN UNDERGROUND COMMITTEE GUIDE 2.6 (2.6/00/0868)

Insulating oil testing

Matz Ohlen Director Transformer Test Systems. Megger Sweden

THE ELECTROM itig II MOTOR TESTER AND WINDING ANALYZER

Cable testing and diagnostics

Insulation resistance testing. A complete solution for every application.

WEIDMANN ELECTRICAL TECHNOLOGY NETA POWERTEST MARCH 2014 ELECTRICAL TECHNOLOGY. WEIDMANN DIAGNOSTIC SOLUTIONS INC. A Member of the WICOR Group

IMPORTANCE OF ACCURATE MEASUREMENTS DURING THE LIFE CYCLE OF UTILITIES

Exploring the Necessity of the Hot Hipot Test

High Voltage Diagnostics Sarl 4, Rue de Lac CH 1897 Le Bouveret Switzerland

High-Voltage Test and

Software System for Finding the Incipient Faults in Power Transformers

Underground System Design TADP 547

MSR Series. Modular Series Resonant Systems kV; 500kVA...60,000kVA FEATURES BENEFITS APPLICATIONS 1/6

Chapter 7 Conclusion 7.1 General

CHAPTER 5 CONCEPT OF PD SIGNAL AND PRPD PATTERN

OMICRON Seminar on Substation Testing and Diagnosis. October 23, 2017 Dubai, United Arab Emirates. October 24, 2017 Abu Dhabi, United Arab Emirates

Insulation Test System

RESIDUAL LIFE ASSESSMENT OF GENERATOR TRANSFORMERS IN OLD HYDRO POWER PLANTS

Name: Craig Goodwin. Company Name: HV Diagnostics Inc

IMPORTANCE OF INSULATION RESISTANCE

Power transformer maintenance. Field Testing.

PRODUCT PORTFOLIO TEST AND MEASURING SYSTEMS

Why partial discharge testing makes good sense

Monitoring Solutions For Power Transformers, Reactors, Bushings and Instrument Transformers

Transformer condition assessment with an integrated test van

MV Power Cable Testing Training

Training Fees 3,300$ per participant including Materials/Handouts, Tea/Coffee Refreshments & International Buffet Lunch.

Condition-based maintenance of power transformers Complete three-phase system Turns Ratio: Recovery Voltage: Winding Resistance:

Cable test vans and systems

PTTS series. Power Transformer Test System. Scope of Work:

POWER TRANSFORMER SPECIFICATION, DESIGN, QUALITY CONTROL AND TESTING 18 MARCH 2009

Cable test vans and systems

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

TECHNIQUES AND STANDARD

PHG 70 TD PD / PHG 80 TD PD

Characteristics of Insulation Diagnosis and Failure in Gas Turbine Generator Stator Windings

UTILITY & SUBSTATION TESTING

International Journal of Advance Engineering and Research Development. Comparison of Partial Discharge Detection Techniques of Transformer

CHANCE Proximity Voltage Indicator

VLF. DAC tandelta. Partial Discharge. Experience the world of Megger electrical testing

COMPANY PROFILE... 1 QUALITY CERTIFICATES... 2 APPLICATIONS... 3

SGMF(T) series. Onsite Mobile AC High Voltage Test System. Applications:

CITY SERIES. Compact, fully equipped cable fault location, test and diagnostic systems

Transformers handling and transport

Power Engineering II. High Voltage Testing

An Overview of Diagnostic Testing of Medium Voltage Power Cables John Densley

Power Transformer Products & Services INCREASED PERFORMANCE & UPTIME

Transcription:

TRAINING OVERVIEW EDUCATION IS POWER www.hipotronics.com/training reliable. precision. HIGH V O L T A G E T E S T S OLUTION S

2 EDUCATION IS POWER EDUCATION IS POWER LEARN WHAT WE HAVE TO OFFER Through our courses, you will gain familiarity with a wide range of test sets and applications. By applying the workflow supported by our superior product line, you can be sure that your tests are accurate and consistent. Specifically, you will learn how to generate reliable test reports, practice general safety, and utilize wellorganized step-by-step procedures. We also provide value-added assurance to guarantee your test labs are up to date with the most recent revisions to national and international high voltage (HV) testing standards. Our courses are ideal for a number of those working in the HV business, including but not limited to manufacturers of high voltage equipment, utilities, universities, laboratories, and maintenance and service companies. It is important to us to help you understand the solutions available when facing difficulties during diagnostics. Most importantly, we want to help save you money by speeding up test time in the field. All courses are taught in English and are held at our facility in Brewster, New York. Please find more details on our website at www.hipotronics.com/training.htm. High voltage apparatus Manufacturers UTILITIES UNIVERSITIES LABORATORIES MAINTENANCE AND SERVICE COMPANIES

A MESSAGE FROM OUR LEADER 3 A MESSAGE FROM OUR LEADER GENERAL MANAGER AND VICE PRESIDENT OF THE HUBBELL HIGH VOLTAGE TEST BUSINESS For over 50 years, Hipotronics has been the world s leading full-line manufacturer of high voltage test equipment and measurement instrumentation. As a member of the Electrical Systems Group of Hubbell Inc., we continue to advance our record of innovation. Now, we feel it s time to share some of our expertise. Expanding the training side of our business has always been a goal of ours, and it is with great honor that we finally present Hipo University. Hipo University is staffed with our best engineers to provide you high-quality training opportunities. After all, we have 100+ years of combined experience with Hipotronics, Haefely, and Tettex. In the field in which we work, it is of utmost importance to feel comfortable, confident, and safe while operating our equipment. That is why the professional courses we offer focus on not only theory, but also on practice. Our mission is to reinforce technical knowledge and best testing practices in a hands-on environment. We look forward to enabling your success and adding long-term value to your company. Sincerely, Reinhold Grob

4 TRAINING OVERVIEW TRAINING OVERVIEW Training courses take place in Brewster, NY or at the customer location. At our facility you will be afforded an opportunity to gain valuable skills and gather with peers to discuss hot topics in the industry. Certification is provided to each individual upon completion of the course(s). Lunch may be provided upon request of attendees. CURRENT COURSES AVAILABLE: Cable Fault Locating Transformer Diagnostics Aerial Lift Testing The length of our courses vary by subject. Please contact us at training@hipotronics.com to sign up and begin scheduling. MORE Want to learn more about us? Visit our website to see why, in a world of imitators, we stand alone as the original and still the best. Follow us on Twitter (@HFLYHIPO), LinkedIn (HAEFELYHIPOTRONICS), and YouTube. Interested in our products and service? Call us at 845.279.3644 or e-mail us at sales@hipotronics.com.

CABLE FAULT LOCATING 5 CABLE FAULT LOCATING As the industry pioneer in cable and wire testing, Hipotronics remains the premier supplier for all your testing needs. That s one reason why our professionals are your go-to people for training in this area. Although cables are built to last, faults remain inevitable due to excessive moisture, corrosive environments, overheating, and aging. This course will help customers learn how to operate a wide range of cable fault locators using the most innovative TDR (Time Domain Reflectometer) techniques and best portable contact thumper the market has to offer. It will also focus on ways to reduce fault location time and allow for quick sectionalizing of faulted loop feed URD (Underground Residential Distributions). We want to help you pinpoint faults quickly and accurately. This training is usually held over the course of 3 days. LEARN HOW TO: Isolate faulted sections using advanced sectionalizing techniques Locate and interpret cable faults with TDR (Time Domain Reflectometer) waveforms on radial and loop feed systems Pinpoint cable faults with Ballistic and Acoustic Listening Devices (FlashPhone) Verify integrity of cable insulation RELEVANT PRODUCTS: Portable cable fault locator systems (5250 Series, X-WAVE) Truck-mount thumpers (CF Series, CET) Fault location radars and accessories (TDR Series, HVC series, Open/Short Locator)

6 TRANSFORMER DIAGNOSTICS TRANSFORMER DIAGNOSTICS Testing of transformers is important for both manufacturers and end users. Manufacturers need to be certain their units are meeting the desired specifications, while end users need to perform regular maintenance procedures to detect minor fault symptoms before timely and costly failures occur. This course is designed to help transformer manufacturers, utility and contract workers, repair companies, and research labs satisfy their testing needs. In addition to training, HAEFELY HIPOTRONICS provides installation, calibration, repair, and system upgrade services to keep your systems performing at the highest level. This training is usually held over the course of 2 days. LEARN HOW TO: Measure insulation resistance Measure polarization index Perform winding resistance measurement for any size transformer Assess condition of transformer insulating oil with dielectric withstand tests Run three-phase and single-phase turns ratio meters (TTR) Measure power factor and dissipation factor to detect aging and deterioration within the insulation of the transformer Measure short circuit impedance of power transformers at reduced current Perform capacitance and tan delta testing Conduct frequency response analysis to verify mechanical/electrical integrity RELEVANT PRODUCTS: NOTE This course can be further tailored for transformer manufacturers to include partial discharge testing, induced voltage testing, lightning impulse testing, applied AC testing, and loss testing. Insulation resistance tester (5478, HVM Series) Winding resistance meter (2293) Oil dielectric test set (OC60D, OC90D, E-series) Turns ratio meter (2795, 2796) Power factor tester (MIDAS) Frequency response analyzer (FRA5310)

AERIAL LIFT TESTING 7 AERIAL LIFT TESTING Protecting the lives of lineman and ensuring their overall safety is a top priority for both utilities and tree removal companies. Sometimes the voltage withstand ability (dielectric breakdown) of aerial life devices could be the difference between life and death. That s where we come in. Our equipment allows for electric tests that tell whether or not a truck s upper boom can safely contact high voltage lines. This course provides step-by-step training on how to test the electrical strength of boom insulators (per ANSI Standard A92.2) as well as the voltage withstand ability of hydraulic hoses and the oil they contain. Moreover, we will shed light on test results implying dielectric failures due to: contamination of the insulator surfaces; chemical (internal or external) deterioration of the insulator; aging or degradation of the fiberglass/ rubber insulating material; moisture absorption; substitution of improper insulating material with inadequate dielectric constants or voltage withstand ability. LEARN HOW TO: Properly apply high voltage across the insulator portion of the boom Measure the resulting current flow through the insulator in accordance to ANSI Standard A92.2 Improve on skills required to record and interpret test results Learn how to properly position lift trucks (both articulating and telescoping) for acceptance and maintenance testing RELEVANT PRODUCTS: Portable HVT series AC hipots (60HVT, 100HVT, 120HVT) Portable 800 Series DC hipots (880PL-10MA, 8120-5PL, 8170-5PL) 700 Series AC dielectric test sets This training is usually held over the course of 1 day.

OFFICES: Europe China North America Haefely Test AG Haefely Test AG Representative Beijing Office Hipotronics, Inc. Birsstrasse 300 8-1-602, Fortune Street 1650 Route 22 N 4052 Basel No. 67, Chaoyang Road, Chaoyang District Brewster, NY 10509 Switzerland Beijing, China 100025 United States + 41 61 373 4111 +86 10 8578 8099 +1 845 279 3644 + 41 61 373 4912 +86 10 8578 9908 +1 845 279 2467 sales@haefely.com sales@haefely.com.cn sales@hipotronics.com HAEFELY HIPOTRONICS has a policy of continuous product improvement. We therefore reserve the right to change design and specification without notice.