TETRIS User's Guide. High Impedance Active Probe DO177-1

Similar documents
TETRIS 1000 High Impedance Active Probe. Instruction Manual

PKT 512A-RO High Impedance Passive Cable Divider

PHV RO High Voltage Passive Probe. Instruction Manual

PHV 1000-RO High Voltage Passive Probe. Instruction Manual

TA MHz oscilloscope probe TA MHz oscilloscope probe

TK 100 Probe Calibrator. Instruction Manual

400 MHz Passive High-Voltage Probe R&S RT-ZH

PML 791-RO. High impedance passive probe. Features: 2.5 mm Diameter Tip. Coaxial Design. Interchangeable Spring Contact Tip

PHV 1000-RO. High impedance passive probe. Features: CeramCore TM hybrid probe. Modular construction. Coaxial design

As all PMK probes the PML 751-RO features CeramCore TM technology. The entire probe

PMT 211A-RO. High impedance passive probe. Features: CeramCore TM Hybrid Probe. Modular Construction. Coaxial Design

PHV RO. High impedance passive probe. Features: CeramCore TM Hybrid Probe. Modular Construction. Coaxial Design

PMT 221A. High impedance passive probe. Features: CeramCore TM Hybrid Probe. Modular Construction. Coaxial Design. Interchangeable Spring Contact Tip

PML 711A-RO High impedance passive probe Features:

SA1500X. Operating Basics. Cautions DEVICE SPECIFICATIONS. High Impedance Active Probe

Supplied in carry case with additional accessories The PHV 1000-RO is a 400 MHz, standard sized, 100:1 passive probe designed for instruments

Operator s Manual. PP016 Passive Probe

supplies and frequency converters. BumbleBee is also very effective in fast transient measurements

User s Manual. Miniature Passive Probe. IM EN 3rd Edition

Operator s Manual. PP022 Passive Probe

BumbleBee. High Voltage Differential Probe Ord.-No: Features:

Operator s Manual. PP017 and PP018 Passive Probes

TA MHz ±30 V Differential Probe User s Manual. This probe complies with IEC , IEC CAT I, Pollution Degree 2.

TA MHz x10/x100 Differential Probe User s Manual. This probe complies with IEC , IEC CAT III, Pollution Degree 2.

TA MHz ±700 V Differential Probe User s Manual. This probe complies with IEC , IEC CAT III, Pollution Degree 2.

Documentation. PerfectPulse Fast Edge Signal Generator

RIGOL. User s Guide. RP1000D Series High Voltage Differential Probe. Feb RIGOL Technologies, Inc

Model: PR-55. High Voltage Oscilloscope Probe 10 kv, 40 MHz USER MANUAL

USER. manual. Falco Systems WMA-100. High Voltage Amplifier DC - 500kHz

RIGOL. User s Guide. RP5600 Passive Probe. July 2010 RIGOL Technologies, Inc.

User s Guide. RP7000 Series Active Probe. Dec RIGOL Technologies, Inc.

MDC4500-4B Amplifier/Combiner Data Sheet & User Manual. February Rev 0.95

P5100A & P5150 High Voltage Probes Performance Verification and Adjustments

TT-SI MHz DIFFERENTIAL PROBE

34134A AC/DC DMM Current Probe. User s Guide. Publication number April 2009

Keysight N2771B 30 kv High Voltage Probe

CURRENT MEARUREMENT SHUNT CS-10/500 USER MANUAL

200Amp AC Clamp Meter + NCV Model MA250

Model 5100F. Advanced Test Equipment Rentals ATEC (2832) OWNER S MANUAL RF POWER AMPLIFIER

TT-SI 9001 / TT-SI MHz Active Differential Probes

DUAL CHANNEL BROADBAND LINEAR AMPLIFIER Model A800D

BROADBAND LINEAR AMPLIFIER Model P150

P5100A & P5150 High Voltage Probes Performance Verification and Adjustments

2015 RIGOL TECHNOLOGIES, INC.

TT-SI MHz Active Differential Probe

USER MANUAL. Ultra-Low Noise High Voltage Amplifier WMA V to +150V output. 300µV rms output noise. 2mV output offset voltage

TT-SI MHz Active Differential Probe

The table below lists the symbols used on the Clamp and/or in this manual. Important Information. See manual.

MODEL 3810/2 Line Impedance Stabilization Network

INSTRUCTION MANUAL. Model Autoranging DMM ProbeMeter TM. Measures voltage, resistance, frequency, capacitance, temperature, and duty cycle.

User s Guide. 400A AC/DC Clamp Meter. Model MA220

User s Manual Current Probe IM E. 8th Edition

USER MANUAL. DC - 5MHz High Voltage Amplifier WMA V to +100V output. DC to -3dB large signal bandwidth. 1300V/µs slew rate typical

MD 200A High voltage differential probe

Pen Multimeter. Model

Current Probe Fixture Instruction Manual

AC/DC Current Probe GCP-100 QUICK START GUIDE ISO-9001 CERTIFIED MANUFACTURER

USER MANUAL. DC 13kHz High Voltage Amplifier WMA V to +175V output. Stable with all capacitive loads, generates no overshoot

2001A. 200KHz Function Generator Instruction Manual. 99 Washington Street Melrose, MA Phone Toll Free

Advanced Test Equipment Rentals ATEC (2832)

Keysight N2790A Differential Voltage Probe. User Guide

User s Manual. MiniTec TM Series. Model MN26 (Model MN26T includes temperature probe) Mini Autoranging MultiMeter

Autoranging Multimeter Extech EX503

1157A 2.5 GHz Active Probe

AM-510 Commercial / Residential Multimeter. AM-510-EUR Digital Multimeter. Users Manual

Instruction Manual CT-6 High Frequency AC Current Probe

AT Advanced Wire Tracer. Users Manual

N2792A and N2793A Differential Probes User s Guide

VT1586A Rack Mount Terminal Panel Installation and User s Manual

BROADBAND LINEAR AMPLIFIER Model F1020 (models F10A and F20A combined)

NI 2865A 0.3 A Matrix Cards for NI SwitchBlock

Model 3725/2M. Line Impedance Stabilization Network (LISN) User Manual

DDS Function Generator

User s Manual Current Probe. IM E 2nd Edition. Yokogawa Electric Corporation

User Guide. Digital AC/DC Clamp Meter Model 38394

Electrical Multimeter

User s Guide. Digital AC/DC Clamp Meter Model 38394

1156A 1.5 GHz Active Probe

BROADBAND'LINEAR'AMPLIFIER WITH'A±B'INPUTS'AND'DC5OFFSET Model&A400X

INSTRUCTION MANUAL. MODEL: Vintage 60R. Vintage Series Guitar Amplifi er

Pen Multimeter. Model

User s Manual Current Probe. IM E 2nd Edition IM E

DUAL%CHANNEL%LINEAR%AMPLIFIER %WITH%PHASE%INVERTER Model&A400DI

INSTRUCTION MANUAL CLAMP ON PROBE

EPA152/252/502. User Manual.

P331-2 set ESD generator (IEC )

PT-2000series AC/DCcurrentprobe PT-2710 PT-2720 PT-2740 PT-2770 MANUAL INSTRUCTION

SPM-50 RF Spectrum Power Meter PC Software User Manual

80i-110s. AC/DC Current Probe Instructions. Introduction

1.5µm PbSe Power Detector

712B. Users Manual. RTD Calibrator. Test Equipment Depot Washington Street Melrose, MA TestEquipmentDepot.

For model: HVP-10R / HVP-18HF / HVP-28HF / HVP-39pro

312, 316, 318. Clamp Meter. Users Manual

BROADBAND'LINEAR'AMPLIFIER Model&F10AD

ELECTROSURGICAL UNIT ANALYZER

netzerotools.com 374/375/376 Users Manual Clamp Meter

User s Guide. MultiView Series Digital MultiMeters Models: MV110 MV120 MV130

Tablet Oscilloscope Safety Information

USER'S MANUAL DMR-6700

N2790A Differential Voltage Probe

Transcription:

TETRIS 1500 High Impedance Active Probe User's Guide DO177-1

TETRIS 1500 Copyright 2010 Ltd. All rights reserved. Information in this publication supersedes that in all previously published material. Specifications are subject to change without notice. Manufacturer PMK GmbH Mess- und Kommunikationstechnik Industriestr. 17 63150 Heusenstamm, Germany Sales & Support James House Colmworth Business Park St. Neots PE19 8YP United Kingdom www.picotech.com/support.html Warranty warrants this oscilloscope accessory for normal use and operation within specifications for a period of two years from date of shipment and will repair or replace any defective product which was not damaged by negligence, misuse, improper installation, accident or unauthorized repair or modification by the buyer. This warranty is applicable only to defects due to material or workmanship. disclaims any other implied warranties of merchantability or fitness for a particular purpose. will not be liable for any indirect, special, incidental, or consequential damages (including damages for loss of profits, loss of business, loss of use or data, interruption of business and the like), even if has been advised of the possibility of such damages arising from any defect or error in this manual or product. 2 DO177-1

TETRIS 1500 Declaration of Conformity (EC conformity marking) The manufacturer declares the conformity of this product with the actual required safety standards in accordance with the Low Voltage Directive (LVD) 2006/95/EC: IEC 61010-031:2002 Safety requirements for electrical equipment for measurement, control and laboratory use - Part 031: Safety requirements for hand-held probe assemblies for electrical measurement and test WEEE/RoHS Directives (EC conformity marking) This electronic product is classified within the WEEE/RoHS* category list as monitoring and control equipment (category 9). Category 9 products are exempted from the restrictions under the scope of the RoHS directive. Your help and efforts are required to protect and keep clean our environment. Therefore return this electronic product at the end of its life either to the manufacturer or take care of separate WEEE collection and professional WEEE treatment yourself. Do not dispose as unsorted municipal waste! * EC Directives: WEEE Directive 2002/96/EC - Waste Electrical and Electronic Equipment RoHS Directive 2002/95/EC - Restriction of the use of certain Hazardous Substances in Electrical and Electronic Equipment. DO177-1 3

TETRIS 1500 Safety General Safety Please review the following safety precautions to avoid personal injury and prevent fire or damage to this product or products connected to it. Be aware that if you use this probe assembly in a manner not specified the protection this product provides may be impaired. Review and comply with the following safety precautions: Only qualified personnel should use this probe assembly. DO connect and disconnect properly. Connect the probe output to the measurement instrument and connect the ground lead to earth ground before connecting the probe to the circuit under test. Disconnect the probe input and the probe ground lead from the circuit under test before disconnecting the probe from the measurement instrument. DO observe probe ratings. Do not apply any electrical potential to the probe input which exceeds the maximum ratings of the probe. Make sure to comply with the voltage versus frequency derating curve on page 7. DO keep away from live circuits. Avoid open circuitry. Do not touch connections or components when power is present. DO NOT connect the probe ground lead to a potential other than earth ground Use only grounded instruments. Always make sure the probe and the measurement instrument are grounded properly. DO NOT operate with suspected failures. Refer to qualified service personnel. DO NOT use outdoors. This is product is for indoor use only. Do not operate in wet/damp environment. Keep product surfaces dry and clean. DO NOT operate this product in an explosive atmosphere. Symbols The following symbols may appear on the product or in this instruction manual: Caution, risk of danger. Refer to manual Caution, risk of electric shock Earth (ground) terminal 4 DO177-1

TETRIS 1500 1. About the Tetris Active Probe System presents a unique Inline Probing System the TETRIS active probe. The unique design of the TETRIS active probe allows for contact to adjacent square pins in 2.54 mm pitch simultaneously. This is possible due to the probe's housing being T-shaped and allowing many probes to be positioned next to each other, permitting multiple measurements to be taken at the same time. The TETRIS is independent of any particular system, and with its standard BNC connector it can be plugged onto any measuring instrument with a 50 Ω input. With an input resistance of 1 MΩ and an input capacitance of 0.9 pf the TETRIS probe is suitable for measurements in all frequency ranges. Compared to passive probes the TETRIS active probe offers a high input impedance into the GHz-range. Passive probes with their relative high input capacitance load the signal source already at frequencies above 100 khz. This is why the TETRIS active probe with its high input resistance and its low input capacitance is the ideal probe for most of your daily measurements. TETRIS 1500 testing adjacent pins in 2.54 mm Pitch DO177-1 5

TETRIS 1500 2. Operating Basics When using this active probe device make sure the measuring instrument is set to 50 Ω input coupling and the probe is connected to the power supply. Note: If the measuring instrument does not have 50 Ω coupling, an external 50 Ω terminator can be used (such as a TA051) however, the system bandwidth may be reduced. 3. Handling The probe cable is a sensitive part of the probe. Do not risk damage through excessive bending or pulling of the cable. Avoid mechanical shock to this product in general to guarantee accurate performance and protection. 4. Maintenance Cleaning To clean the exterior of the probe use a soft cloth moistened with either distilled water or isopropyl alcohol. Allow the probe to dry completely before use. 6 DO177-1

TETRIS 1500 5. Specifications Specifications that are not defined as "guaranteed" are typical and are published as general information for the user. The instrument should have warmed up for at least 20 minutes prior to use, and the environmental conditions should not exceed the probe's specified limits. Electrical Specifications Attenuation Ratio 10:1 ± 0.5 % at DC Dynamic Measuring Range ± 8 V System Bandwidth (1) 1 GHz (-3 db) Bandwidth (Probe only) 1.5 GHz Maximum Rated Input Voltage 20 V Max. Input Voltage and Dynamic Measuring Range The TETRIS active probe is protected against electrostatic discharge (ESD). Applying input-voltages outside the specified limits can result in destruction of the probe s amplifier. Make sure you comply with the input voltage vs. frequency chart below to avoid input linearity errors and damage to the probe. Note that the max input voltage rating of the probe decreases as the frequency of the applied signal increases. 100 Input Voltage vs. Frequency TETRIS 1500 Voltage [V] AC pk 10 Maximum Input Voltage Dynamic Measuring Range Electrical Characteristics 1 1M 10M 100M 1G 10G Frequency [Hz] Input Resistance (System) > 1 MΩ Input Capacitance (System) 0.9 pf (typical) Oscilloscope Input Coupling 50 Ω AC / DC (1) connected to oscilloscope >1 GHz with built in 50 Ω termination. DO177-1 7

TETRIS 1500 6. Accessories Included Z - Ground Ground Blade 2 adhesive Cu Pads ( 2 x 2 cm ) DEVICE UNDER TEST Spring Tip Solid Tip L - In Adapter Y-Lead Adapter to 0.8 mm Sockets Pico-Hook red Pico-Hook black 8 DO177-1

TETRIS 1500 Marker Bands 4 Colors Ground Lead 6 cm Ground Lead 12 cm Ground Lead 90 5 cm Ground Lead 90 10 cm DO177-1 9

TETRIS 1500 7. Specifications Input Impedance Note that the input impedance of the probe decreases as the frequency of the applied signal increases. 10M Typical input impedance TETRIS 1500 1M Z [Ohm] 100k 10k 100 1k 10k 100k 1M 10M 100M 1G Frequency [Hz] Mechanical Characteristics Weight (probe only) Cable Length 96 g 1.3 m Environmental Specifications Altitude Operating up to 2000 m Non-operating up to 15000 m Temperature Range Operating 0 C to +45 C Non-operating -40 C to +71 C Maximum Relative Humidity Operating 80 % relative humidity for temperatures up to +31 C, decreasing linearly to 40 % at +50 C 10 DO177-1

TETRIS 1500 8. Scope of Delivery The following items are included in the scope of delivery. Please check the delivery for completeness. If any item is missing, send a message to our help desk and we will send you this item immediately. Item Qty Ground Blade 1 Ground Lead 6 cm 1 Ground Lead 12 cm 1 Ground Lead 90 5 cm 1 Ground Lead 90 10 cm 1 Instruction Manual 1 L-In Adapter 1 Marker Bands 4 colors 1 Pico-Hook black 1 Pico-Hook red 1 Power Supply 1 Probe 1 Protection Cap 2.5 1 Self adhesive Cu Pad (2 x 2 cm) 2 Solid Tip 0.5 mm 1 Spring Tip 0.5 mm 1 Y-Lead Adapter to 0.8mm sockets 1 Z-Ground 1 Use ground lead only for connections to earth ground. The accessories provided with the probe have been safety tested. Do not use any other accessories than those originally provided. DO177-1 11

TETRIS 1500 Revision History Revision# Date Reason 1 July 2010 First issue James House Colmworth Business Park St. Neots PE19 8YP United Kingdom www.picotech.com is a registered trademark of Ltd. Copyright Ltd. 2010 12 DO177-1