Product Information PI

Similar documents
Product Information PI

Stationary Anode X-Ray Tube. General Data

Product Information PI

Product Information PI

Product Information PI

Rotating Anode X-Ray Tube Housing Assembly. General Data. IEC Classification... Class I Type B

Rotating Anode X-Ray Tube Housing Assembly. General Data. IEC Classification... Class I

ROTANODE TM E7252X E7252FX E7252GX Rotating Anode X-Ray Tube Housing Assembly. General Data. IEC Classification... Class I Electrical :

Rotating Anode X-Ray Tube Housing Assembly. General Data

Product Information PI

Rotating Anode X-ray Tube

Rotating Anode X-Ray Tube Housing Assembly. General Data

Rotating Anode X-ray Tube Assembly

Industrial X-ray Tube KL

CIRCLEX 0.3/0.8P324&0.6/1.2P324DK-85

Technical Data TD. X-Ray FLAT PANEL IMAGER FDX3543RP FEATURING: Active Area: 35(H) 43(V)cm (14 17 ) Excellent Sensitivity & Resolution

PET1606J2F. Pilani Electron Tubes & Devices Pvt. Ltd. Water Cooled Triode. For Industrial RF Heating. Drop in equivalent of BW1606J2F

MXRP-160C. Product Description. Product Specifications

ARU-01CF Portable X-Ray NSN:

The AMK 15-2 is a high-power metal/ceramic triode, intended for use in industrial generators for frequencies

Digital Panoramic X- Ray unit. Product Data

E2V Technologies CX1175C Deuterium-Filled Ceramic Thyratron

ACS600, ACS800. Installation Guide

PET1610F. Pilani Electron Tubes & Devices Pvt. Ltd. Forced-Air Cooled Triode. For Industrial RF Heating. Drop in equivalent of BW1610F

MG5223F S-Band Magnetron

X-ray Tube and Generator Basic principles and construction

MG MW S-Band Magnetron

E2V Technologies MG5223F S-Band Magnetron

E2V Technologies CX1725, CX1725X Liquid Cooled, Hollow Anode, Two-Gap Metal/Ceramic Thyratrons

Technical data CAMARGUE CS-VH50/300. VARIABLE Height Bucky Table With Ceiling Suspension

GE Sensing & Inspection Technologies. The ISOVOLT Titan E X-ray Generator

Atomscope PORTABLE VETERINARY X-RAY EQUIPMENT INSTRUCTION MANUAL. Version 1.0

Abridged Data. General Data. MG7095 Tunable S-Band Magnetron for Switched Energy Applications. Cooling. Electrical. Accessories.

DENTAL RADIOGRAPHY KAMARUL AMIN BIN ABU BAKAR

VGM Series. 100 & 60 W, Efficient, CV Class 2 LED Drivers for Signage Applications ORDERING INFORMATION

MG7095 Tunable S-Band Magnetron

YD1195/8913 YD1197/8937 RF Power Triodes

MKP1V120 Series. Sidac High Voltage. Bidirectional Triggers 0.9 AMPERES RMS VOLTS

CR02AM-8. Thyristor. Low Power Use. Features. Outline. Applications. Maximum Ratings. REJ03G Rev.1.00 Aug Planar Passivation Type

PERFORMANCE SPECIFICATION SHEET ELECTRON TUBE, NEGATIVE GRID (MICROWAVE) TYPE /

X-rays. X-rays are produced when electrons are accelerated and collide with a target. X-rays are sometimes characterized by the generating voltage

World-Class Accuracy & Measurement Range (40 Conventional Models)

GE Inspection Technologies. The ISOVOLT Titan E X-ray Generator

MILADY. Product Data. Page 1 of 8

1. Carlton, Richard R., and Arlene M. Adler. Principles of Radiographic Imaging: An Art and a Science, 5th edition (2013).

Mammography is a radiographic procedure specially designed for detecting breast pathology Approximately 1 woman in 8 will develop breast cancer over

TIC116 SERIES SILICON CONTROLLED RECTIFIERS

HIGH FREQUENCY X-RAY MONOBLOCK 3.5kW

ic-sd85 olga SD2C3 Infrared LED

TIC106 SERIES SILICON CONTROLLED RECTIFIERS

MG5193 Tunable S-Band Magnetron

M5028 Precision Tuned Magnetron

X-band Magnetron. Cooling (note 5) Water Output coupling (note 6) UG51/U Magnet (note 7) Integral, Permanent

X-ray Tube and Generator Basic principles and construction

FFSH5065A. Silicon Carbide Schottky Diode 650 V, 50 A

HIGH FREQUENCY X-RAY MONOBLOCK 3.5kW

GE AMX 4+ Portable X-Ray

PERFORMANCE SPECIFICATION SHEET ELECTRON TUBE, NEGATIVE GRID (MICROWAVE) TYPE /

SA5.0A Series 500 Watt Peak Power MiniMOSORB Zener Transient Voltage Suppressors

E2V Technologies M5187F X-Band Magnetron

QED223 Plastic Infrared Light Emitting Diode

S-band Magnetron. Tuner revolutions to cover frequency range 4.75 (note 3) Mounting position (note 4) Any Cooling (note 5) Water

5 W XENON FLASH LAMP MODULES

S24SP12004 series 40W Single Output DC/DC Converter

S24SP05012 series 60W Single Output DC/DC Converter

S24SP24003 series 60W Single Output DC/DC Converter

MobileDaRt Evolution MX8 Version

Disclosure to Promote the Right To Information

PERFORMANCE SPECIFICATION SHEET ELECTRON TUBE, MAGNETRON TYPE 8943

BCA 9SK. 60 Hz on request Absorbed current on Stationary Vac and Vac in fluoro mode

X band Magnetron. Water: Anode cavity Forced-air: Input ceramics and terminals Output coupling (note 6) UG51/U Magnet (note 7) Integral, Permanent

TECHNICAL INFORMATION

E2V Technologies MG6028 Fast Tuned Magnetron

USER MANUAL. Maxwell Technologies Ultracapacitor Energy Storage Modules. Models: BMOD0058 E016 B02 BMOD0006 E160 B02. Document

ProX Intraoral X-ray. PLANMECA is proud to introduce a new intraoral X-ray unit to its comprehensive collection of imaging products- the ProX.

P R E S E N T E D B Y. K A M A R U L A M I N A B D U L L A H Dip. MED. IMG., BSc. MED. IMG. (UiTM)

URA_LD-15W & URA_LD-20W Series 15/20W, 4:1ULTRA WIDE INPUT ISOLATED & REGULATED DUAL OUTPUT DC-DC CONVERTER

Svetlana 4CX7500A Radial Beam Power Tetrode

SPECIFICATION. Kilovoltage X-ray calibration system for protection and diagnostic level dosimetry. Prepared by

2014 CINDE Toronto Portable X-ray & X-Ray Production

HY-3002/5948A-Replacement Hydrogen Filled Triode Thyratron

Low Capacitance Transient Voltage Suppressors / ESD Protectors CM QG/D. Features

TIC106 SERIES SILICON CONTROLLED RECTIFIERS

VIM Series. 90 & 60 W, Efficient, CV Class 2 LED Drivers ORDERING INFORMATION

ACULED DYO TM Design-Your-Own Guide

XRC X-Ray Calibration System

SMF5.0AT1G Series, SZSMF5.0AT1G Series. 200 W Transient Voltage Suppressor SOD-123 Flat Lead Package

X-RAY IMAGING EE 472 F2017. Prof. Yasser Mostafa Kadah

30KP SERIES. Features. Mechanical Data. Maximum Ratings and Electrical A =25 C unless otherwise specified

Ceramic Disc Capacitors Class 2, 500 V DC, 1 kv DC, General Purpose

VLM60/40 Series. 60 & 40 W, Efficient, Compact Constant Voltage Class 2 LED Drivers

URA_LD-15W & URA_LD-20W Series 15/20W, 4:1ULTRA WIDE INPUT ISOLATED & REGULATED DUAL OUTPUT DC-DC CONVERTER

Performance Specifications

ASMB-KTF0-0A306-DS100

PRODUCT DATA. Sound Intensity Calibrator Type Uses and Features

Electrical Specifications

Low voltage products in high altitudes

BAV103 High Voltage, General Purpose Diode

ic-tl46 TO46-2L1 Blue LED

SBT700-06RH. Schottky Barrier Diode 60V, 70A, VF; 0.66V Dual To-3PF-3L Cathode Common

Transcription:

Product Information PI TOSHIBA X-RAY TUBE D-045 Stationary Anode X-ray Tube Especially designed for dental radiography unit. This tube has focus 0.4, and is available for maximum tube voltage 70 kv. Installed in the same enclosure with the high voltage transformer. Electrical: General Data Circuit: High Voltage Generator... Constant Potential High-Voltage Generator Grounding... Center-Grounded Nominal X-ray Tube Voltage (IEC60613:2010)... 70 kv Nominal Focal Spot Value (IEC60336:2005) Note)... 0.4 Nominal Anode Input Power (at 1.0s) (See rating Charts)... 585 W Nominal Radiographic Anode Input Power (IEC60613:2010)... 600 W Exposure Duty Cycle... 1:30 or more (Exposure time: interval time) Note) Test Condition: 70kV 3.2mA Mechanical: Dimensions: Overall Length... See dimensional outline Maximum Diameter... See dimensional outline Target: Anode Angle... 12.5 degrees Material... Tungsten Inherent Filtration... At least 1.0 mm Al X-ray Coverage... φ70 mm at SID 200 mm Weight... Approx. 100 g Cooling Method... Oil immersed (60 Max.) and convection oil cooling Tube Holding... Holding the glass envelope of the anode end and cathode end or the screw of the anode shank.. The information contained herein is presented only as a guide for the applications of our products. No Responsibility is assumed by TOSHIBA ELECTRON TUBES & DEVICES CO.,LTD.(TETD) for any infringements of patents or other rights of the third parties which may result from its use. No license is granted by implication or otherwise under any patent or patent rights of TETD or others. The information contained herein may be changed without prior notice. It is therefore advisable to contact TETD before proceeding with the design of equipment incorporating this product.

Absolute Maximum and Minimum Ratings (At any time, these values must not be exceeded.) Maximum X-ray Tube Voltage (IEC60613:2010)... 70 kv Between Anode (or Cathode) and Ground... 35 kv Minimum X-ray Tube Voltage... 50 kv Maximum X-ray Tube Current (IEC60613:2010) (See rating Charts)... 12 ma Filament Characteristics: Maximum Filament Current... 3.0 A Filament Frequency Limits... DC or AC (Sine Wave) 0 ~ 20 khz Thermal Characteristics: Anode Heat Content... 4300 J Maximum Anode Heat Dissipation... 100 W Maximum Radiographic Exposure Time... 3.2 s Environmental Limits Operating Limits (in dielectric oil): Oil Temperature... 10 ~ 60 Oil Pressure... 70 ~ 140 kpa Shipping and Storage Limits: Temperature... -40 ~ 70 Humidity... 10 ~ 90 % (No condensation) Atmospheric Pressure... 50 ~ 106 kpa - 2 -

Maximum Rating Charts (Absolute maximum rating charts) 12 Constant Potential High-Voltage Generator Nominal Focal Spot Value: 0.4 50kV TUBE CURRENT [ma] 10 8 6 4 2 60kV 70kV 0 0.1 0.2 0.3 0.5 0.7 1 2 3 5 7 10 EXPOSURE TIME [s] Refer to IEC60613:2010 Emission & Filament Characteristics Constant Potential High-Voltage Generator Nominal Focal Spot Value: 0.4 12 50kV 4.0 10 60kV 3.5 TUBE CURRENT [ma] 8 6 4 Ef 70kV 3.0 2.5 2.0 FILAMENT VOLTAGE [V] 2 1.5 0 1.0 2.2 2.3 2.4 2.5 2.6 2.7 2.8 2.9 3.0 FILAMENT CURRENT [A] Note1) This graph indicates typical characteristics. Note2) Refer to IEC60613:2010-3 -

Anode Heating / Cooling Curve 4500 4000 3500 4300J 100W HEAT STORAGE [J] 3000 2500 2000 1500 1000 COOLING 50W 500 HEATING 0 0 50 100 150 200 250 300 TIME [s] - 4 -

Dimensional Outline Unit: mm 4.5 ±0.2 (Note) M4 12 Deep O 1.6 Depth 5 min. O 11.75 37 ±2 5 12.5 66 ±5 CENTRAL X-RAY FOCAL SPOT 100 MIn. 8 Max. O31 Max. F C O 13 CENTRAL X-RAY C F F : Filament (Yellow) C : Cathode Note : Dimensions from an anode shank to a mounting hole. - 5 -

OVERSEAS SUBSIDIARIES AND AFFILIATES EU REPRESENTATIVE TOSHIBA ELECTRONICS EUROPE GMBH HANSAALLEE 181 40549 DÜSSELDORF, GERMANY PHONE +49 (211) 5296-107 FAX +49 (211) 5296-402 For Sales & Technical Services, please contact the following representative: TOSHIBA ELECTRONICS EUROPE GMBH HANSAALLEE 181 40549 DÜSSELDORF, GERMANY PHONE +49 (211) 5296-107 FAX +49 (211) 5296-402 TOSHIBA AMERICA ELECTRONIC COMPONENTS, INC. 2150 EAST LAKE COOK ROAD, SUITE 310 BUFFALO GROVE, ILLINOIS 60089 USA PHONE +1 (847) 484-2400 FAX +1 (847) 541-7287 TOSHIBA ELECTRON DEVICES & MATERIALS (SHANGHAI) CO., LTD. (TEMS) RM1606, SH-PLAZA, No.336, XIZANG ROAD (MIDDLE), SHANGHAI, 200001, CHINA PHONE +86 (21) 6361-0077 FAX +86 (21) 6351-5760 (Product Development Engineering Department) 1385 SHIMOISHIGAMI, OTAWARA-SHI, TOCHIGI-KEN, 324-8550, JAPAN PHONE: +81-287-26-6666 FAX: +81-287-26-6060 http://www.toshiba-tetd.co.jp/ Toshiba Electron Tubes & Devices Co., Ltd. meets the Environmental Management System Standard, ISO14001. Toshiba Electron Tubes & Devices Co., Ltd. meets internationally recognized Standards for Quality Management System ISO9001, ISO13485.