INSTRUCTIONS FOR 1431 Door Closer with Hold Open Arms 1431 SERIES ADJUSTABLE FROM SIZE 1 THRU 6

Similar documents
1431 DOOR CLOSER WITH STANDARD DUTY ARMS (WITHOUT HOLD OPEN) INSTALLATION INSTRUCTIONS 1431 SERIES ADJUSTABLE FROM SIZE 1 THRU 6

351 DOOR CLOSER WITH DOUBLE LEVER ARM (OP) INSTALLATION INSTRUCTIONS

SARGENT 1331 DOOR CLOSER INSTALLATION INSTRUCTIONS WITH JUH (HOLD OPEN) ARMS

SARGENT 1331 DOOR CLOSER INSTALLATION INSTRUCTIONS WITH JUO (JO & JP9) ARMS

ASSA ABLOY Series Installation Instructions. Regular Arm. Parallel Arm. Top Jamb Mount. Multi-Sized 1 thru 6 Non-Hold Open and Hold Open Models

These door closers should NOT be installed on the exposed side (weather side) of exterior doors. WOOD 3/16" 1/4"- 20

DC3210. Recommended Closer Size

316R Series Installation Instructions

5200 Series Door Closer Installation Instructions

Installation Instructions. Installation Type

Installation Instructions. Installation Type

Installation Type. Edge of Door. Pull (Hinge) Side Mounted. Hinge Edge of Door. Push (Stop) Side Mounted

Installation Instructions

Regular Arm Installation. Closer mounts on hinge side of door (pull side) See Page 3. Closer cover not shown. Top Jamb Installation

ASSA ABLOY. Model W91 Overhead Concealed Wood Frame Installation Instructions IMPORTANT: BEFORE INSTALLING: TO DETERMINE HAND OF YOUR DOOR:

INSTRUCTIONS TS93 GSR PT RIGHT HAND ACTIVE LEFT HAND INACTIVE RIGHT HAND INACTIVE LEFT HAND ACTIVE

TS93 STH. Surface applied door closer. Installation instructions: Pull side door mounted spring track Inverted closer with hold open (STH)

INSTALLATION INSTRUCTIONS FOR INSTALLING T-SERIES EXTRA HEAVY DUTY LEVER LOCKSET

For installation assistance, contact SARGENT at DOORS SHOWN HERE SWING IN FOR ILLUSTRATION PURPOSES ONLY.

Active Push Bar. Safety glasses Measuring tape Level Pencil Power drill Drill bits: 5/32, 3/4 Center punch Phillips screw driver

Safety glasses Measuring tape Level Pencil Power drill Center punch Phillips screw driver Saw horse

800 SERIES. Heavy-Duty Commercial Grade 1 Surface Applied Closers. Standard Features. 3 hours fire rated. openings of the door.

Door Closers. General Information

ED1300/1300F SERIES CONCEALED VERTICAL ROD DEVICE INSTALLATION INSTRUCTIONS

CRL JACKSON 900 SERIES

Medium HoneyBadger Chase Rack Installation Instructions

How To Measure Your Finished Opening

(Wood Door and Frame)

ESA-200 Fixed Sidelite

Installation Instructions 3040 (05-09) 9/16 9/ /32 9/32. Checking Adjustments

*18758* 2030 Series. 1 Installation. 2 Adjustment. 3 Hold Open Information BACKCHECK. * Hold open tracks. Installation Instructions

33/3527A. Devices covered by these instructions: 33/3527A-F (Fire) Surface Vertical Rod Exit Device

FRAME PREPARATION 3900/8900 SURFACE LATCH CONCEALED ROD EXIT DEVICE INSTALLATION INSTRUCTIONS HOW TO FIND BACKSET. Date: Appvd: *13/16 2 3/4" 3/4 HOLE

33/3547A. Special tools needed: #10-24 tap Drill bits: #25, 5/16, 13/32, 1/2

INSTALLATION INSTRUCTIONS. Thermal Entrances AA 250/AA 425 THERMAL DOOR WITH TRIFAB 601/601T FRAMING

ESA-300 Full Breakout

CONCEALED VERTICAL ROD PANIC EXIT DEVICE

Installation Instructions

Installation Instructions 50 (06-09) 1-15/32 15/32 21/32. 1/4-20 x 5/8" FHMS or #14 x 1/2" FHWS 1/16 1/4. Floor Plate

1. Begin by rolling your window up all the way 2. Remove your door and window handles by unscrewing the flat head set screws behind each handle.

INSTALLATION INSTRUCTIONS VENETIAN 84" SLIDING SHOWER DOOR SYSTEM (180º INSTALLATION)

98/9927. Devices covered by these instructions: Surface Vertical Rod Exit Device

ED5800 (A) Series. Installation Instructions. Concealed Vertical Rod. Exit Device WARNING

ESA-100 Fixed Sidelite/Non Breakout

INSTALLATION INSTRUCTIONS Small Flat Panel Height-Adjustable, Extended Pitch Swing Arm Wall Mount Model KWE-110

1530(F) Mortise Exit Devices Installation Instructions

TOOLS REQUIRED Metal Wood Wood and Metal Screws. #16 Drill #12-24 Tap. 1/8 Drill

33/35A Series. Devices covered by these instructions: Rim Exit Device. CD33/35A Rim Exit Device EL33/35A Rim Exit Device SS33/35A Rim Exit Device

PFD-22 Top OHC Patch Fitting & PFD-10 Bottom Patch Fitting Installation Instructions

Fig. 2 DORMA-Glas Stand/Issue 02/03 Seite/Page 1/7

Shim (2) Supplied. Strike Plate. (3) x 5/8" PFHMS or 10 x 1" PFHWS. Top Latch. (3) x 1/4" PRHMS. Latch Cover. (2) 8 x 3/8" PFH AB SMS

4600 Series Rim Narrow Stile Exit Device Installation Instructions I-ED01162

RH-412 STEEL DOORS INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS RH 412 STEEL DOORS

D3976 RECESSED EXIT INSTALLATION INSTRUCTIONS

ICU TRACKLESS SLIDING DOOR

FINISH GROUPS #17 GRP #17 CLEAR

EXIT DEVICE OPERATION FIRE DOOR LABELS, STRIKES AND FRAME SCREWS FOR INFORMATION CALL OR VISIT RITEDOOR.COM

TOOLS REQUIRED FOR ASSEMBLY. Rubber Mallet or Plastic Tip Hammer PARTS REQUIRED FOR ASSEMBLY OF SINGLE ENTRY STARTER.

MantelMount. TM1A Installation Instructions IMPORTANT SAFETY INSTRUCTIONS - SAVE THESE INSTRUCTIONS

INSTALLATION INSTRUCTIONS

Kai Installation Instructions

Entry Mortise Handleset

INSTALLATION INSTRUCTIONS FOR PLASCORE NARROW STILE DOORS

Installation and Assembly - Universal Articulating Swivel Double-Arm for 42" - 60" Plasma Screens

Wooden Frame Type Instruction Manual

IDR assembly instructions:

Installation Instruction

Step by Step Installation Instructions. Poly Shutters. Customer Service or visit us online at smithandnoble.com

Semi-Frameless Hinged Door With Panel And Return

White Quail Auto Trap

Preference Collection 5580 Treatment Console INSTALLATION GUIDE

Preference Collection and Treatment Console INSTALLATION GUIDE

GlideRite Retractable Cover System For Hot Spot Spas (SE & SLX only)

SALICE AIR TEMPLATE KIT

Atrium Patio Door Field Service Manual

Installation and Assembly - Universal Articulating Swivel Double-Arm for 42" - 60" Plasma Screens

MCH42 / MCH48 MODULAR SERIES 2400/3000 CORNER HUTCH

Rim-Lock Door Set Installation Instructions

ICU TRACK SLIDING DOOR

Door Controls. Table of Contents

Privacy Wall Glass Selections - Polished Edge Slider Door

User Instructions Multiline Otter Scoreboard Caddy Assembly

GlideRite Retractable Cover System For HotSpring & Tiger River Spas (except Classic & pre-2000 Landmark Spas)

GATE INSTALLATION INSTRUCTIONS

Note: The dimensions of the Template are shown in inches. See attached page for the Metric Conversion Table for millimeters.

Calf-Tel Pen System Assembly Instructions

POWER PET. Low-E Automatic Patio Pet Door Installation and Operating Instructions

Quill Stop V2 Installation Guide 11/16/2014

ASSEMBLY AND ADJUSTMENT

Preference Collection 5531 Accessory Console I NSTALLATION GUIDE

INSTALLATION INSTRUCTIONS

Installation/Care/Use Manual Soft Sides Freeze Resistant Fountain

Phone # La Jolla Doors. Block Frame Installation Manual Aluminum Frame with either Vinyl or Aluminum Panels

western window systems westernwindowsystems.com installation instructions non-pocket 2-1/4 panels

7110(F), 7170(F)(LBR) Surface Vertical Rod Exit Device Series Installation Instructions

TITAN2-EDGE Public Access Computer Station Dual Track

ED5200S(A) Series ED5200S(A) Series x M107 Windstorm Series SecureBolt Exit Device

HIT-30 ALUMINUM DOOR SERIES OWNERS MANUAL

Entry Mortise Lock Set Lever to Lever

Transcription:

INSTRUCTIONS FOR Door Closer with Hold Open Arms SERIES ADJUSTABLE FROM SIZE THRU 6 FOR INSTALLATION ASSISTANCE CALL SARGENT AT -800-77-77 / www.sargentlock.com Installation Instructions based on Application and Arm type Standard Mounting Application - H arm For Standard Application - the Door Closer is mounted on the hinge side of door (see page ) Parallel Arm Application - PH9 Arm For Parallel Arm Application - the Door Closer is mounted on the stop side of door (see page ) Top Jamb Application - H, HZ & HZA Arm For Top Jamb Application - the Door Closer is mounted on the frame on the stop side of the door (see page 6) + LEFT HAND RIGHT HAND or STOP SIDE HINGE SIDE HINGE SIDE STOP SIDE IMPORTANT NOTICE PRE-DRILL / HOLES FOR SELF-TAPPING SCREWS OR TAP #- FOR MACHINE SCREWS A70F

A B A) Select closer mounting position based on the maximum door opening, as listed below Note: For ADA applications, select the 60ϒ position B) Prep door and frame Note: /" pilot holes are required when Self Tapping Screws are being used Note: If machine screws are being used, use a drill #6 (.77) and a #- tap B) Install closer body onto the door B) Install Foot & Rod Assembly onto the frames DIM. A DIM. B STANDARD APPLICATION -/" # X / SCREWS OR #- X /8 FLAT HEAD MACHINE SCREW* TOP OF MAXIMUM OPENING DIM. A DIM. B 0ϒ 7 /" /" 60ϒ** /" 0" **If Butt, Frame and Wall Conditions Permit Door Will Open 80ϒ " 7 8" " 8" CLOSER 9 6" 6" 8" MIN TOP RAIL RAILS TO " MAY BE USED PROVIDED DOES NOT PROJECT BEYOND FACE OF C C OF HINGE PIVOT L ILLUSTRATED. SAME DIMENSIONS APPLY FOR LEFT HAND. *SEE PAGE 8 FOR MORTISE NUTS C) Install main arm on the closer with the index mark on the spindle aligning with the # on the main arm (as shown) FACE OF D Attach POSITION OF WHEN ASSEMBLING TO SPINDLE hold open foot to frame with adjusting nut facing down for left hand door or up for right hand door, as illustrated below NUT FACES UP NUT FACES DOWN SHOWN LEFT HAND SHOWN A70F

E STANDARD APPLICATION E) Opening the door slightly, slide rod into swivel arm and then close the door E) With the door closed, position the swivel arm so that it is 90º to the door surface E) Tighten the arm screw securely POSITION OF WHEN ASSEMBLING TO SPINDLE SCREW 90ϒ OPEN F Adjust closer as required (See page 8 for details). ACCESSORIES INFORMATION ROD H8 MORTISE FOOT FOR USE WHERE THE STANDARD SURFACE APPLIED FOOT CANNOT BE ATTACHED TO THE TOP CASING OR WHERE APPEARANCE IS A MAJOR FACTOR 0-J COVER PLATE MAY BE USED WHEN CLOSER IS MOUNTED ON A NARROW RAIL TO IMPROVE APPEARANCE WHEN CLOSER IS VIEWED THRU GLASS -W corner bracket closer is mounted on bracket which is attached to door jamb on stop side of door Use this application for exterior doors to keep the closer inside of building; Also may be used to obtain full 80ϒ door opening MORTISE NUTS FOR BOLTING THRU THE ARE FURNISHED WHEN ORDERED A70F

MAXIMUM OPENING A70F

C INSTRUCTIONS FOR INSTALLING PARALLEL APPLICATION CLOSER MOUNTED ON STOP SIDE OF Select degree of door opening required and attach door closer body to door (long end toward hinge) and foot bracket to frame (according to illustration on A page ). Use templates enclosed for special arms. Mount hold open arm to bracket with adjusting screw facing down for left hand door, facing up for right hand door. NUT FACES UP LEFT HAND SHOWN SHOWN D D) NUT FACES DOWN Install main arm on the closer with the index mark on spindle aligned with the number on the arm Note: Left Hand Doors -align index mark with the # on the main arm (as shown) Note: Right Hand Doors -align index mark with the # on the main arm (as shown) D) This requires the spindle to be rotated D) Rotate the spindle on the bottom of the closer to align index mark with the required number on the arm LEFT HAND PRELOAD Left Hand Door Right Hand Door FOOT BRACKET SCREW OPEN ROD E E) Opening the door slightly, slide rod into swivel arm and then close the door. E) With the door in the closed position, swivel the arm so that the pivot is an -/" off the door surface (as shown below) E) Tighten the arm screw securely PRELOAD LEFT HAND -/" F Adjust closer as required. See page 8 for details. ACCESSORIES INFORMATION FOOT BRACKET SCREW OPEN ROD #H8 MORTISE FOOT /" MIN. 0-D DROP BRACKET CLOSER IS MOUNTED ON PLATE WHEN TOP RAIL IS TOO NARROW 0-J COVER PLATE May be used when closer is mounted on a narrow rail to improve appearance when closer is viewed through glass MORTISE NUTS FOR BOLTING THRU THE ARE FURNISHED WHEN ORDERED #8 MORTISE FOOT For use where the standard surface applied foot cannot be attached to the top casing or where appearance is a major factor A70F

TOP JAM APPLICATION INSTALLATION INSTRUCTIONS LEFT HAND ILLUSTRATED SAME DIMENSIONS APPLY FOR MEASURE FROM HINGE C L CLOSER MOUNTED ON ABOVE STOP SIDE OF A HINGE SIDE HINGE SIDE -/8" # x -/" WOOD SCREWS OR #- x /8" FLAT HEAD MACHINE SCREWS STOP SIDE STOP SIDE THIS IS A LEFT HAND THIS IS A CLOSERS ARE NON-HANDED /8" CLOSER TOP OF " DIM "A" -/" -/8" -/" CLOSER FOOT APPLIED TO C L OF CLOSER MOUNTING SCREWS -9/6" " C L OF HINGE PIVOT DEPTH OF REVEAL ASSEMBLY TYPE REVEAL DEPTH DIM. A MAX OPENING RANGE OF OPEN H 0" TO " -/" 80 80-80 HZ -/8" TO " 6-/" 0 80-0 HZA -/8" TO 8" 7-/" 0 80-0 SPRING ADJUSTMENT ADJUST SPRING POWER ACCORDING TO CHART. DECREASE POWER SPRING POWER ADJUSTING NUT + INCREASE POWER CW-CLOCKWISE CCW-COUNTER CLOCKWISE NUMBER OF TURNS OF SPRING POWER ADJUSTING NUT* USE CHART AS GUIDE ONLY. WIDTH (INCHES) 0 6 0 6 8 OVER 8 APPROXIMATE WEIGHT (POUNDS) 80 0 0 0 6 70 80 0 CLOSERS - CCW FACTORY** SET - CW -7 CW 7-0 CW * FOR EXTERIOR S USE 0 CLOSERS ONLY. ** CLOSERS ARE FACTORY SET FOR INTERIOR S. * CLOSERS FACTORY** SET -7 CW 7-0 CW FOR EXTERIOR S AND WHERE STRONG DRAFT EXISTS INCREASE SPRING POWER AS NEEDED BY TURNING SPRING ADJUSTING NUT CLOCKWISE. IF NECESSARY, DECREASE SPRING POWER TO MEET REQUIREMENTS BY TURNING SPRING ADJUSTING NUT COUNTER CLOCKWISE. 6 A70F

D D) INSTRUCTIONS FOR INSTALLING TOP JAMB Install main arm on the closer with the index mark on spindle aligned with the number on the arm Note: Left Hand Doors -align index mark with the # on the main arm (as shown) Note: Right Hand Doors -align index mark with the # on the main arm (as shown) CLOSER MOUNTED ON ABOVE STOP SIDE OF LEFT HAND LEFT HAND POSITION OF WHEN ASSEMBLING TO SPINDLE E Attach hold open foot to frame with adjusting nut facing down for left hand door or up for right hand door as illustrated below. NUT FACES UP NUT FACES DOWN F SHOWN F) Opening the door slightly, slide rod into swivel arm and then close the door F) With the door closed, position the main arm so it is at 90º to the door surface F) Tighten the arm screw securely LEFT HAND LEFT HAND SHOWN RIGHT ANGLE POSITION OF WHEN ASSEMBLING TO SPINDLE SCREW OPEN ROD G Adjust closer as required. See page 8 for details. A70F 7

FINAL ADJUSTMENT AND REGULATING PROCEDURE Minimum recommended door closing time is 6 Seconds for doors opened to 90 degrees. Use /8 hex (Allen) wrench to adjust valves as needed. Closing and latching speeds: Turn valves clockwise to slow down or counterclockwise to speed up door movement. Backcheck: To regulate the intensity of back check action, turn valve clockwise to increase or counterclockwise to decrease checking. CAUTION: Set valve for slight cushioning effect; closer can be damaged if the checking action is too abrupt. Never use the backcheck as a door stop. Always use a door stop to stop the door. Delayed action feature (Optional feature on some models): Delayed action provides slow door closing through the delayed action range. Turn valve clockwise to slow down or counterclockwise to speed up door movement. NUMBER OF TURNS OF SPRING POWER ADJUSTING NUT WIDTH (INCHES) CLOSER -0 TURN nut - 0-6 FACTORY SET 6- TURN nut - -8 TURN nut 7-9 Adjusting door to close due to high draft conditions may exceed ADA standards. Consult local ordinances when fire doors are involved Adjustment hold open arm Slight tightening or loosening of hold open nut changes holding position of door. Note: To protect wall, trim and closer, use a door stop located 0 beyond hold open position but not beyond the max. door opening shown on instructions. OPEN NUT USE /6" WRENCH TO ADJUST NUT COVER DRILL /" DIA. HOLE FOR MOUNTING SCREWS UNREINFORCED STOP MORTISE NUT HEAD DRILL /8" DIA. HOLE FOR MORTISE NUT BODY. For top jamb and corner bracket applications: The door closer foot will be attached to the door in a manner similar to that shown for mounting the closer body.. The appropriate mortise nuts and screws will be suppled based on door thickness. Door construction must provide a bridge type reinforcement to prevent the door rail from collapsing when through-bolts are tightened. INSTALL COVER AS FOLLOWS: FOR STANDARD AND PARALLEL APPLICATION Screw short cover screw (#8- X /6) into top of case approximately turns Assemble plastic support and long cover screw (#8- X /) into bottom of case approximately turns Hold support against case (approximately turns) between flange and screw head Position cover on closer and tighten screws ILLUSTRATED SHORT COVER SCREW GAP PLASTIC SUPPORT AND LONG COVER SCREW INSERT IS REMOVABLE. PLACE IN UNUSED OPENING FOR TOP JAMB APPLICATION Assemble plastic support and long cover screw (#8- X/") into top of case approximately turns Screw short cover screw (#8- X /6") into bottom of case approximately turns Slide cover into gap between flange and screw head. Position cover on closer and tighten screws PLASTIC SUPPORT AND LONG COVER SCREW SHORT COVER SCREW INSERT IS REMOVABLE. PLACE IN UNUSED OPENING 8 A70F