User Instructions. Model PS-2001L. Power Supply. Model SPS Power Supply. Audiocom Intercom Systems Rev. A, 4/2001.

Similar documents
Telex. User Instructions. Model SPS2000A Power Supply Audiocom Intercom Systems SPS2000A. Volume RESET

Model WM1000/WM2000. Wall Mount Intercom Stations. User Instructions

VAC. -er I CAUTION 0 U CAT. N MADE I N USA. 2 COMWNENl REFERTO OPERATION MANUAL CHN. T0 lnlercom SYSTEM SAME TYPE

User Instructions DSI 2008 Digital System Interface ADAM, ADAM CS, and Zeus Intercoms

Opus 21 s80 Integrated Amplifier Owner's Manual

KRAMER ELECTRONICS LTD. USER MANUAL MODEL: 912 Power Amplifier. P/N: Rev 2

Installation & User Guide. For Powering Distributed Audio Systems A45-X2 TWO CHANNEL AMPLIFIER

EQ-AMP60 60W Mixer Amplifier

HX-3. Headphone Distribution Amplifier User Guide and Technical Information

SX204. Headphone Amplifier. Symetrix. Owner s Manual

HX-3 Headphone Distribution Amplifier

Model CC4041. CC Series Amplifier. Installation and Use Manual

Model CC4052. CC Series Amplifier. Installation and Use Manual

léìë=on ëpm=fåíéöê~íéç=^ãéäáñáéê lïåéêdë=j~åì~ä êéëçäìíáçå

Amplifier Series BASIC. Installation & Operations Manual

Vi6208, Vi6216, Vi6232 Vi6308, Vi6316, Vi6332

Instruction Manual Model M Switch, DPDT, Manual Select

USER MANUAL MODEL Time Division Multiplexor, RS-232 (CTS TDM-V.24) SALES OFFICE (301) TECHNICAL SUPPORT (301)

JMAA-3600HR16-UL. Installation and Operation Instructions. Performance Series 360w RMS 4-Channel Amplifier Kit For Harley RoadGlide Ultra

Model 5100F. Advanced Test Equipment Rentals ATEC (2832) OWNER S MANUAL RF POWER AMPLIFIER

JMAA-1800HR15. Installation and Operation Instructions. 180w Performance Series Amplifier Kit For Harley RoadGlide/ Ultra

Broadband Step-Up Transformer. User Manual

PDB4. Four Channel Passive Direct Box USER'S GUIDE

S 275 Stereo Power Amplifier THE LEADER IN AUDIO ENGINEERING. Instructions for Use. Owner s Reference

Owner s Manual.

SI-125 Power Amplifier Manual 6205 Kestrel Road; Mississauga, Ontario; Canada; L5T 2A1 November 2016, Rev 0.5

Performance Series 360w 4-CH Amplifier Kit For Harley Street Glide with Lower/Rear Speakers JMAA-3600HC14-SG

TM-800 Main Station. Instruction Manual. TELIKOU Systems All Rights Reserved

Instruction Manual Model Upconverter

model 101 single channel microphone preamplifier owner s manual Rev C

Owner s Manual DKW-3 HT. Wireless VHF Microphone System

CMP-300 Composite Mixer/ Distribution Amplifier

CURRENT SENSING 12VOLT TRIGGER CS12V

Smart-UPS RT. Isolation Transformer Models: SURT001 and SURT002 Isolation and Step-Down Transformer Models: SURT003 and SURT004.

S-4VC/S-6VC. For Connecting Four/Six Pairs of Speakers to an Amplifier or Receiver, with Precise Volume Adjustment in any Zone

SoundPals. DAC-24 User Guide. Stereo D-to-A converter

GPNP Inc. NT384 NT1 User Manual. Revision /6/2002. Information in this guide is subject to change without notification.

Document Version 1.2

Performance Series 360w Amplifier Kit For Harley RoadGlide with Lower/Rear Speakers JMAA-3600HR15-RC

Instruction Kit MIXER AMPLIFIER GT 60C GT 125C. GROMMES-PRECISION SINCE-46

PA WATT PORTABLE PA SYSTEM PRODUCT MANUAL

USER MANUAL MODEL Parallel to Serial/ Serial to Parallel Interface Converter

Instruction Manual Model Upconverter

USER MANUAL. MODEL 457B Seven Port Active Twinax Star Hub. SALES OFFICE (301) TECHNICAL SUPPORT (301)

TABLE OF CONTENTS. 1) Introduction 2. 2) Unpacking your preamplifier 2. 3) Installing the preamp into your system 3

441 DUAL CHANNEL 15 BAND 2/3 OCTAVE GRAPHIC EQUALIZER 451 SINGLE CHANNEL 31 BAND 1/3 OCTAVE GRAPHIC EQUALIZER

Classic Series Public Address Amplifiers C10 & C20 Models

A-16D A-Net Distributor

TONE ALERT RECEIVER MODEL 2TR9A. P.O. Box West Pacific. Lexington, NE 68850

T L Audio CRIMSON SERIES. User Manual EQ-3012 PARAMETRIC EQUALISER. Tony Larking Professional Sales Limited, Letchworth, England.

JAMP-630HC14-ULP. Installation and Operation Instructions. ROKKER XXRP 630w Amplifier Kit For Harley Ultra/Ultra Ltd.

HTA125A/250A. Power Amplifiers. Installation & Use Manual

SS-4.2 / SS-6.2. Instruction Manual. Impedance Matching Speaker Selector

T L Audio. User Manual EQ1 VALVE EQUALISER. Tony Larking Professional Sales Limited, Letchworth, England.

For Precise Volume Adjustment with Programmable Muting in Any Room

HARDSCAPE SUBWOOFER INSTRUCTION MANUAL HS12T SUB

T L Audio CRIMSON SERIES. User Manual EQ-3011 EQUALISER. Tony Larking Professional Sales Limited, Letchworth, England.

High Performance Microphone Splitter. Artcessories. User's Manual

VideoEase VGA 1x4 Distribution Hub (500150, ) Installation Guide

Table of Contents. Overview... 3

Flying Never Sounded So Good

Owner s Manual B 300 B 600 B 900 B 1200 B 1500 B 902 B 1202 B 1802 B300 B1802

HQ-31 HQ-15 USER S GUIDE SINGLE CHANNEL 31 BAND 1/3 OCTAVE GRAPHIC EQUALIZER DUAL CHANNEL 15 BAND 2/3 OCTAVE GRAPHIC EQUALIZER

VOLUME CONTROL CONNECTION TERMINAL

Telex. Operating Instructions. RadioCom TM WIRELESS IFB SYSTEMS TR-34 TUNABLE RECEIVER TT-44 TRANSMITTER

DUAL LEVELAR. Two Channel Tube Compressor/Leveling Amplifier

JAMP-700HR15-RCP. Installation and Operation Instructions. ROKKER XXRP 700w Amplifier Kit For Harley RoadGlide with Lower/Rear Speakers

TLS-3A. Telephone Line Simulator. User Manual , Rev. B Covers Model TLS-3A-01

4 Channel Frequency Conscious Noise Gate. Operation Manual

Video Mono Audio Baluns

CONNECT SYSTEMS INCORPORATED 1802 Eastman Ave., Suite 116 Ventura, Ca FLEX SERIES UNIVERSAL CONTROLLER

WARRANTY We at DigiTech are very proud of our products and back-up each one we sell with the following warranty:

S 1500 MULTI-CHANNEL INSTRUCTIONS FOR USE AMPLIFIER. Owner s Reference

GT-1050A 2 GHz to 50 GHz Microwave Power Amplifier

Glass Electrode Meter

Manual and User Guide

VideoEase Component Video Hub (500250, , , ) Installation Guide

XPR522 XPR540. XPR SERIES INSTALLATION / OWNER'S MANUAL Mobile Power Amplifiers

MANLEY LABORATORIES, INC. OWNER'S MANUAL MANLEY 50 WATT MONOBLOCK AMPLIFIER

AV30MX-2 Operation Manual

PS 19 AM SINGLE CHANNEL BELTPACK IN METAL CASE WITH PGM (AUX) INPUT

301 & 601 Mic/Line Mixers Operation Manual

Installation Instructions

LPF-100 Composite Low Pass Filter

INSTRUCTION MANUAL MODEL 2455T SUBCARRIER MODULATOR

INSTALLATION INSTRUCTIONS

INSTALLATION GUIDE. Video Balun Transceiver with fixed BNC for twisted pair operation with other balun transceivers or active receivers.

DIGITAL AUDIO AMPLIFIER WITH BLUETOOTH. Model: DAA User Manual

TELIKOU Intercom System

Owner s manual. SDA 2175 Semi Digital Amplifier

Classic Series Public Address Amplifiers C10 & C20 Models

Distribution Amplifiers 1

User s Guide Instructions for Installation and Operation

SIR-WRR1. User's Guide SIRIUS Echo Antenna. Signal Repeater System Accessory

Easy-Link Plus Version 2.2

User Manual LMS-325 Line Monitor Speaker

KRAMER ELECTRONICS LTD. USER MANUAL MODELS: SPK-C612 Closed-back Ceiling Speakers SPK-C412 SPK-C411. P/N: Rev 1

KeyPre KP6 - Electronic Instrument Preamplifier

SAFETY INSTRUCTIONS Read all the safety and operating instructions before connection or using the SAE All warnings on the unit and in this

Synthesized Base Station Transmitter

Transcription:

User Instructions PS-00L Model PS-00L Power Supply SPS-00 Volume Model SPS-00 Power Supply Audiocom Intercom Systems 950-7699-000 Rev. A, /00

FCC Statement This equipment uses, and can radiate radio frequency energy that may cause interference to radio communications if not installed in accordance with this manual. The equipment has been tested and found to comply with the limits of a Class A computing device pursuant to Subpart J, Part 5 of FCC Rules which are designed to provide reasonable protection against such interference when operated in a commercial environment. Operation of this equipment in a residential area may cause interference which the user (at his own expense) will be required to correct. This product meets Electromagnetic Compatibility Directive 89/6/EEC

Table of Contents Description... PS-00L... SPS-00... 5 Installation... 6 Unpacking... 6 PS-00L... 6 SPS-00... 6 Configuration Switches... 6 Intercom Channel and Program Connections... 6 Desktop or Rackmount Installation... 6 Specifications... General... Intercom Channels... General... Balanced Mode (set to position)... Unbalanced Mode (set to UN position)... Speaker Inputs (SPS-00 Only)... Approvals... Power-Up Check...

Description The PS-00L and SPS-00 are versatile power supplies that can be used in a variety of Audiocom intercom system applications. They both directly accept any AC input power from 00 to 0 VAC, 50/60 Hz and can be configured to power two separate intercom channels or one large intercom channel with twice the intercom station capacity. Additionally, the units can be configured for compatibility with Clear-Com* Intercom Systems. The units may be rack mounted or used on a desktop. For rack mounting, optional hardware is required. For desktop use, four non-marring rubber feet are supplied. The SPS-00 also provides a speaker with two mixed inputs making it ideal for situations calling for a master station with a microphone / speaker combination. PS-00L PS-00L Combine Isolate CH CH 00-0 VAC 60/50 HZ TELEX COMMUNICATIONS, INC. MADE IN USA UN CLASS WIRING.5A VDC Figure - PS-00L Front and Rear Panel Features. 5.... 5. : When in the Combine position, the unit will combine the audio signals of the two channels to create a single audio channel where all users can intercommunicate. When in the Isolate position, the unit will create two groups of completely independent users. Channel Status Indicators: The indicators are green for normal operation and red when there is an overload or short circuit. The circuitry in the unit will automatically reset when the overload or short circuit is located and fixed. Universal AC Power Input: The unit accepts any input power in the range of 00-0 VAC, 50/60 Hz. Intercom Channel Connectors: When the Combine / Isolate switch is set to the Isolate position, each channel connector is powered separately and has completely separate intercom audio. When the Combine / Isolate switch is set to the Combine position, each channel is still powered separately, but the audio signals are combined so that all users on both channels can intercommunicate. / UN Selector Switch: This selector switch allows the user to configure the unit for use in either an Audiocom (ANCED) or Clear-Com (UNANCED) system. Compatibility includes channel connector pin-outs, channel power requirements, and call signaling requirements. The default setting for this switch is in the Audiocom () position.

SPS-00 SPS-00 Combine Isolate Volume 5 INPUT CH CH SPEAKERS VRMS 00-0 VAC 60/50 HZ TELEX COMMUNICATIONS, INC. MADE IN USA INPUT UN CLASS WIRING.5A VDC 6 Figure - SPS-00 Front and Rear Panel Features..... 5. 6. Speaker, Inputs, and Volume Control: Two audio inputs are provided. The inputs are combined internally and sent as a monaural signal to the internal speaker amplifier. The Volume control adjusts the level to the front panel speaker. Typically, these inputs are used with the speaker outputs of a master station when the master station is set for use with a panel microphone and speaker instead of a headset. : When in the Combine position, the unit will combine the audio signals of the two channels to create a single audio channel where all users can intercommunicate. When in the Isolate position, the unit will create two groups of completely independent users. Channel Status Indicators: The indicators are green for normal operation and red when there is an overload or short circuit. The circuitry in the unit will automatically reset when the overload or short circuit is located and fixed. Universal AC Power Input: The unit accepts any input power in the range of 00-0 VAC, 50/60 Hz. Intercom Channel Connectors: When the Combine / Isolate switch is set to the Isolate position, each channel connector is powered separately and has completely separate intercom audio. When the Combine / Isolate switch is set to the Combine position, each channel is still powered separately, but the audio signals are combined so that all users on both channels can intercommunicate. / UN Selector Switch: This selector switch allows the user to configure the unit for use in either an Audiocom (ANCED) or Clear-Com (UNANCED) system. Compatibility includes channel connector pin-outs, channel power requirements, and call signaling requirements. The default setting for this switch is in the Audiocom () position. 5

Installation Unpacking The package contains the following items. Contact the shipper or your Audiocom dealer immediately if anything is damaged or missing. Detach and fill out the registration card and return it to Telex to properly register the product. PS-00L Qty Description PS-00L Power Supply Warranty and registration card User Manual Rubber Feet (install for desktop use of the PS-00L) Power Cord SPS-00 Qty Description PS-00L Power Supply Warranty and registration card User Manual Rubber Feet (install for desktop use of the PS-00L) Power Cord RCA to RCA Patch Cord Configuration Switches The / UN switch (located on the rear of the unit) is set to the Balanced (Audiocom) position when the unit is shipped from the factory. To set the switch to the Unbalanced (Clear-Com) mode, use a pointed object such as a pen to push in the switch. The Combine / Isolate switch (located on the front of the unit) can be changed at any time by using a pointed object such as a pen to push in the switch. When the switch is in the Combine position, all users on both channels may intercommunicate. When the switch is set to the Isolate position, channels and cannot intercommunicate. Intercom Channel and Program Connections Channel Capacity: When connecting intercom stations to the PS-00L or SPS-00, determine the total current for all stations on each channel. The total per channel should not exceed A. If you exceed this limit, an overload indication will be provided and the output of the power supply will be turned off. Once the overload is corrected, the overload indication will disappear and the power supply output will be turned on. Note that if you are using DC wallpacks with some intercom stations, you do not need to add the current consumption of those stations to the total current. Audiocom Connections: Intercom Cable wiring details are shown in Figure. Speaker interconnection cables (SPS-00 only) are standard RCA phono types. For program input cable wiring, refer to your master intercom station user manual. Some typical intercom applications are shown in Figures through 8. Clear-Com Applications: Refer to your Clear-Com system documentation for intercom cable wiring and connection details. Desktop or Rackmount Installation For desktop use, install the four supplied rubber feet to the bottom of the unit. Do not obstruct the cooling vents when using the unit on a desktop. For rackmounting, use an optional Audiocom Rackmount Kit. Several kits are available to meet the requirements of your particular system. Follow the assembly instructions supplied with the rackmount kit. 6

TYPICAL -CHANNEL CABLE WIRING Pair Pair (Both wires) Shield Shield Cable Type: AWG Stranded, -Pair Twisted-wire, with Shield Connector Type: -Pin XLR Audio (Neutrik or Switchcraft) Pin : Common Pin : Channel Audio / Power Denotes twisted pair. Pin : Channel Audio / Power Denotes shield. Shield: Earth ground TYPICAL -CHANNEL CABLE WIRING Pair 6 5 Pair 6 5 Shield Pair Cable Type: AWG Stranded, -Pair Twisted-wire, with Shield Connector Type: 6-Pin XLR Audio (Neutrik only, not compatible with 6-pin Switchcraft) Pin : Channel & Common Pin : No connection Pin : Channel Audio / Power Denotes twisted pair. Pin : Channel Audio / Power Pin 5: Channel Audio / Power Denotes shield. Pin 6: Channel Audio / Power Shield: Earth ground Ch Case Ch Shield Y CABLE WIRING Pair Pair Pair * (Both wires) Shield 6 5 (Both wires) Shield * Use second drain wire if available, or add an extra section of wire. * Standard cables are generally constructed using a male connector at one end and a female connector at the other end. This allows several cables to be interconnected to create longer cable runs. Audiocom master stations, speaker stations and belt packs also typically provide both a male and female Neutrik connector for each intercom channel. This permits loop-through connection of several intercom stations using the standard cables. Audiocom power supplies use a -pin male Neutrik connector for each channel. Audiocom wallplates use male Neutrik connectors. Figure - Cable Wiring Diagrams for Audiocom Applications. 7

PROGRAM INPUTS -5 VDC 00-0 VAC 60/50 HZ TELEX COMMUNICATIONS, INC. MADE IN USA P.A. EXP OUT SPEAKERS VRMS - OUT UN - IN PGM CHN UN CH CLASS WIRING.5A VDC PGM CH CHN PS-00L Power Supply set to Isolate -channel cable -channel cable Y Y cable + - US000A Master Station BP-000 To all stations on channel To all stations on channel BP-000 BP-000 BP-000 Y BP-000 BP-000 Note: A JB- Junction Box may be used instead of the Y cables. The JB- provides a means of combining two channels, while also allowing the single channels to be continued directly from the junction box. Y BP-000 BP-000 Figure - Typical connections using a single PS-00L Power Supply to power two channels. 8

PROGRAM INPUTS -5 VDC 00-0 VAC 60/50 HZ TELEX COMMUNICATIONS, INC. MADE IN USA P.A. EXP OUT SPEAKERS VRMS - OUT UN - IN SPEAKER VRMS PGM CHN INPUT INPUT UN CH CLASS WIRING.5A VDC PGM CH CHN SPS-00 Power Supply set to Isolate -channel cable -channel cable Y Y cable Speaker Interconnect cable. Program Input cable. From audio sources BP-000 + - To all stations on channel To all stations on channel BP-000 US000A Master Station BP-000 BP-000 Y BP-000 BP-000 Note: A JB- Junction Box may be used instead of the Y cables. The JB- provides a means of combining two channels, while also allowing the single channels to be continued directly from the junction box. Y BP-000 BP-000 Figure 5 - Typical connections using one SPS-00 Power Supply for two intercom channels. The two program sources are monitored independently by their intercom channels. All audio (program and intercom) is monitored as a monaural mix in the SPS-00 speaker. The US000A is set for monaural speaker output (default). 9

-5 VDC VRMS INPUT INPUT PROGRAM INPUTS -5 VDC 00-0 VAC 60/50 HZ TELEX COMMUNICATIONS, INC. P.A. EXP OUT SPEAKERS VRMS MADE IN USA - OUT UN - IN SPEAKER VRMS PGM CHN INPUT INPUT UN CH CLASS WIRING.5A VDC PGM CH CHN SPK000 Powered Speaker SPS-00 Power Supply set to Isolate -channel cable -channel cable Y Y cable TELEX COMMUNICATIONS, INC. MADE IN USA + - Speaker interconnect cables. Program input cable. From audio sources BP-000 + - To all stations on channel To all stations on channel BP-000 US000A Master Station BP-000 BP-000 Y BP-000 BP-000 Note: A JB- Junction Box may be used instead of the Y cables. The JB- provides a means of combining two channels, while also allowing the single channels to be continued directly from the junction box. Y BP-000 BP-000 Figure 6 - Adding an SPK000 to the example in Figure 5. The two program sources are monitored independently by the intercom channels. The SPS-00 monitors intercom channel and program. The SPK000 monitors intercom channel and program. The US000A is set for binaural speaker output as described in the US000A User Manual. 0

00-0 VAC 60/50 HZ TELEX COMMUNICATIONS, INC. MADE IN USA 00-0 VAC 60/50 HZ TELEX COMMUNICATIONS, INC. MADE IN USA SPEAKER VRMS UN CH PROGRAM INPUTS -5 VDC INPUT INPUT CLASS WIRING.5A VDC P.A. UN CH PROGRAM INPUTS -5 VDC EXP OUT CH SPEAKERS VRMS CLASS WIRING.5A VDC P.A. EXP OUT CH SPEAKERS VRMS - OUT UN - IN - OUT UN - IN PGM CHN PGM CHN 00-0 VAC 60/50 HZ TELEX COMMUNICATIONS, INC. PGM MADE IN USA CHN 00-0 VAC 60/50 HZ TELEX COMMUNICATIONS, INC. PGM MADE IN USA CHN SPEAKER VRMS UN CH INPUT INPUT CLASS WIRING.5A VDC UN CH CH CLASS WIRING.5A VDC CH PS-00L Channel Power set to Combine PS-00L Channel Power set to Combine + - PS-L (Optional) on channel on channel on channel on channel Figure 7 - Using two PS-00L Power Supplies to provide a greater capacity on each channel. SPS-00 Channel Power set to Combine SPS-00 Channel Power set to Combine + - PS-L (Optional) Program input cable. From audio sources US000A Internal DIP switches set for binaural operation on channel on channel on channel on channel Figure 8 - Using two SPS-00 Power Supplies to provide a greater capacity on each channel. Using two SPS-00 Power Supplies also lets you independently monitor and adjust volume for both intercom channels without the need for a separate powered loudspeaker. In this application, the US000A should be set for binaural speaker output as described int he US000A manual.

.. Power-Up Check Plug in any DC wallpacks that are being used with individual intercom stations. Note: If you plug in DC wallpacks after applying power to the PS-00L or SPS-00, you may get an overload indication. This is because the stations that are being powered by wallpacks will draw current from the units until their own DC wallpack supplies are connected. To correct the problem, plug in the DC wallpacks. Plug in the AC power cords for any connected PS-00L or SPS-00 Power Supplies. The channel status indicators should be green.. If a channel status indicator turns red during operation, locate the short or overload that is causing the problem. Once the short or overload is corrected, the Power Supply should reset itself and the overload indication should go away. Specifications General Input Power Requirements: 00 to 0 VAC, 50/60 Hz Output Power (each channel): ± VDC, A Dimensions.75 (.5 mm) high x 8.5 (09.5 mm) wide x 0. (6.9 mm) deep Weight: approximately.5 lb (. kg) Environmental Requirements: Storage: -0 C to 80 C, 0% to 95% humidity, non-condensing Operating: 0 C to 50 C, 0% to 95% humidity, non-condensing Intercom Channels General Connector Type: One XLR-M audio connector for each channel. Pin-out depends on setting of / UN switch for balanced or unbalanced operation as defined below: Balanced Mode (set to position) Line Terminating Impedance: 00 ohms ±0% Connector Pin-out: Pin Common (audio and DC return) Pin Full-duplex, balanced intercom audio and + VDC output Pin Full-duplex, balanced intercom audio and + VDC output Unbalanced Mode (set to UN position) Line Terminating Impedance: 50 ohms ±5% Connector Pin-out: Pin Common (audio and DC return) Pin + VDC output Pin Full-duplex, unbalanced Intercom audio high Speaker Inputs (SPS-00 Only) Type: RCA Phone Jack Tip: Speaker + Input Sleeve: Speaker - Input Approvals UL, CUL, CE

TRADEMARKS Audiocom is a registered trademark of Telex Communications. Names of other products mentioned herein are used for identification purposes only and may be trademarks and/or registered trademarks of their respective companies. WARRANTY INFORMATION Products are warranted by Telex Communications, Inc. to be free from defects in materials and workmanship for a period of one year from the date of sale. The sole obligation of Telex during the warranty period is to provide, without charge, parts and labor necessary to remedy covered defects appearing in products returned prepaid to Telex. This warranty does not cover any defect, malfunction or failure caused beyond the control of Telex, including unreasonable or negligent operation, abuse, accident, failure to follow instructions in the manual, defective or improper associated equipment, attempts at modification and repair not authorized by Telex, and shipping damage. Products with their serial numbers removed or effaced are not covered by this warranty. To obtain warranty service, follow the procedures entitled Procedure for Returns and Shipping to Manufacturer for Repair or Adjustment. This warranty is the sole and exclusive express warranty given with respect to Audiocom products. It is the responsibility of the user to determine before purchase that this product is suitable for the user s intended purpose. ANY AND ALL IMPLIED WARRANTIES, INCLUDING THE IMPLIED WARRANTY OF MERCHANTABILITY ARE LIMITED TO THE DURATION OF THIS EXPRESS LIMITED WARRANTY. NEITHER TELEX NOR THE DEALER WHO SELLS TELEX PRODUCTS IS LIABLE FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES OF ANY KIND. CUSTOMER SUPPORT Technical questions should be directed to: Customer Service Department Telex 000 Portland Avenue South Burnsville, MN 557 U.S.A Telephone: (95) 88-05 Fax: (95) 88-00 RETURN SHIPPING INSTRUCTIONS Procedure for Returns If a return is necessary, contact the dealer where this unit was purchased. If a return through the dealer is not possible, obtain a RETURN AUTHORIZATION from: Customer Service Department Telex Communications, Inc. Telephone: -800-9-97 or (95) 88-05 Fax: -800--098 or (95) 88-00 DO NOT RETURN ANY EQUIPMENT DIRECTLY TO THE FACTORY WITHOUT FIRST OBTAINING A RETURN AUTHORIZA- TION. Be prepared to provide the company name, address, phone number, a person to contact regarding the return, purchase order number, the type and quantity of equipment, a description of the problem and the serial number(s). Shipping to Manufacturer for Repair or Adjustment All shipments of products should be made via United Parcel Service or the best available shipper prepaid. The equipment should be shipped in the original packing carton; if that is not available, use any suitable container that is rigid and of adequate size. If a substitute container is used, the equipment should be wrapped in paper and surrounded with at least four inches of excelsior or similar shock-absorbing material. All returns must include the return authorization number. Units sent for repair or adjustment DO NOT need a return authorization number Factory Service department Telex Communications, Inc. West st Street Blue Earth, MN 560 U.S.A. Upon completion of any repair the equipment will be returned via United Parcel Service or specified shipper collect.