The power to work. Power conditioning products. Harmonic correction unit Sag ride-through power conditioner

Similar documents
Power-Sure 700. Technical Data TD158001EN. Contents

Harmonic Solutions. Clean Power Drive Solution to Harmonic Distortion

ULTRA-K Series 600K - he

60K(i) - 260K(i) THREE PHASE. SureImage IMAGING & TREATMENT SERIES

Phoenix DX Clean Power (18 Pulse) AC Drive

Power Conditioners product guide

PQ for Industrial Benchmarking with various methods to improve. Tushar Mogre.

Power Quality Basics. Presented by. Scott Peele PE

Active Harmonic Filter

Section 11: Power Quality Considerations Bill Brown, P.E., Square D Engineering Services

2.1 Performance Standards The UPS is designed with the applicable sections of UL, CUL, and ISO The UPS has UL and CUL listing.

TOSHIBA International Corp

Harmonic Filters for Single Phase Equipment

Est Static Frequency Converter. SFX 10kVA - 10MVA

APQline Active Harmonic Filters. N52 W13670 NORTHPARK DR. MENOMONEE FALLS, WI P. (262) F. (262)

Fundamentals of Power Quality

Strategies for design 600V large modular UPS for critical power applications

Power Commander. Power Commander Plus. Electronic Line Voltage Regulators. 15 kva 150 kva SINGLE PHASE 15 kva 450 kva THREE PHASE SERIES 900

Utility Systems Technologies, Inc. Sag Fighter. Deep Voltage Sag Protection:

QUESTION BANK PART - A

SECTION 16483D ADJUSTABLE FREQUENCY DRIVE - MICRODRIVE (MVX <10-HP)

Low Pass Harmonic Filters

Variable Frequency Drive Packages with Harmonic Mitigation. Low Harmonic Drive Packages Engineered by Rockwell Automation

Harmonics, its Mitigation & Result of Case study of Spinning Mill

Understanding Input Harmonics and Techniques to Mitigate Them

Minimizing Plant Interruption Caused by Line Disturbances Using Active Voltage Conditioners

2.10. Adjustable Frequency Drives. Clean Power Drives. Clean Power Drives

SWF DV/DT Solutions Sinewave Filters. N52 W13670 NORTHPARK DR. MENOMONEE FALLS, WI P. (262) F. (262)

E S C R I P T I V E B U L L E T I N .,.,.,. Bulletin DB-106. October, Square D Company Power System Studies ---1 I SQU ARED COMPANY --

POWER QUALITY AND SAFETY

B9000 FXS kVA B9600 FXS kVA

Ampgard The name motor applications rely on

Power Processor - Series 700F 10KVA to 150KVA

Introduction to Harmonics and Power Quality

G8000MM Series IGBT. 100 to 750 KVA UPS UNINTERRUPTIBLE POWER SYSTEMS. 94% Efficiency. Input PF >0.98 DESIGN

Advanced Harmonic Solutions For Harmonic Current Distortion MOTION CONTROLS

Est Static Frequency Converter. SFX 10kVA - 10MVA

POWER QUALITY PRODUCTS FOR NON-LINEAR LOADS

Harmonic mitigating transformers. Energy savings through harmonic mitigation

Power Quality Analysis: A Study on Off-Line UPS Based System

Harmonic Mitigation for Variable Frequency Drives. HWEA Conference February 15, Kelvin J. Hurdle Rockwell Bus. Dev. Mgr.

SECTION THREE-PHASE UNINTERRUPTIBLE POWER SYSTEM

Power Quality Overview

T-68 Protecting Your Equipment through Power Quality Solutions

POWER FACTOR CORRECTION. HARMONIC FILTERING. MEDIUM AND HIGH VOLTAGE SOLUTIONS.

Power Quality Solutions

Harmonic control devices. ECE 528 Understanding Power Quality

IDEAL Test and Measurement THE BASICS OF POWER QUALITY

1. Introduction to Power Quality

LINEATOR. Advanced Universal Harmonic Filter

AF91 Adjustable Frequency Drives Series B

Condition-based maintenance of power transformers Complete three-phase system Turns Ratio: Recovery Voltage: Winding Resistance:

Understanding Harmonics

PIRANHA 3 (3-phase, Power Conditioning Voltage Regulator)

Electric Power Quality: Voltage Sags Momentary Interruptions

AccuSine PCS Active Harmonic Filter. Cruise through rough waves in your electrical network

Harmonics and Their Impact on Power Quality. Wayne Walcott Application Engineering Manager June, 2017

Emicon Engineering Consultants L.L.C.

Harmonic Distortion and Variable Frequency Drives

POWER DELEGATOR SERIES 7200A POWER DISTRIBUTION UNIT WITH POWER CONDITIONING GENERAL SPECIFICATIONS

Harmonic Filters for Power Conversion Equipment (Drives, rectifiers, etc) Effects of Harmonics IEEE Solutions

Liebert Datawave GUIDE SPECIFICATIONS kva Magnetic Synthesizer Power Conditioning System

VALLIAMMAI ENGINEERING COLLEGE

Liebert Datawave. GUIDE SPECIFICATIONS kva Magnetic Synthesizer Power Conditioning System 1.0 GENERAL

Liebert AF2 Next Generation Active Harmonic Filter. Power Protection for Business-Critical Continuity TM

ECE 528 Understanding Power Quality

Meta-Hearing Defect Detection

P2 Power Solutions Pvt. Ltd. P2 Power Magnetics. Quality Power within your Reach. An ISO 9001:2008 Company

Compliance. Safety Approvals USA Canada Europe. Isolation: General. Dimensions. AC Input CN1 Output CN2 Optional CN3. Weight

UPS (Uninterruptible Power Supply) Digital Signal Processor CM COMANDOS LINEARES CM COMANDOS LINEARES

PRODUCT FEATURES TYPICAL APPLICATIONS

GUIDE SPECIFICATIONS 40-80kVA, kVA and kVA Scalable Three-Phase Uninterruptible Power System 1.0 GENERAL

5000 series Signal Isolation

Industrial Electrician Level 3

How to maximize reliability using an alternative distribution system for critical loads

StacoDVR-4 Digital Voltage Regulator Electromechanical three-phase kVA

Power Protection and Conditioning

APPLICATION GUIDE. Harmonics in HVAC applications

WAVEFORM CORRECTOR (WAVEFORM CORRECTORS) REPLACES SURGE PROTECTION DEVICES (SPD) PREVIOUSLY KNOWN AS (TVSS)

1. Institute of Electrical and Electronic Engineers (IEEE) a. Standard , IEEE Guide for Harmonic Content and Control.

Harmonic Correction Unit NEMA 1 Enclosure

POWER QUALITY MONITORING - PLANT INVESTIGATIONS

SECTIONS , (15040, 15767, 15950, 16269) Guide Specification for VARIABLE SPEED DRIVES with Optional Bypass

ENERGY SAVINGS THROUGH POWER CONDITIONING WITH THE PowerGUARD SYSTEM

AccuSine PCS Active Harmonic Filter. Cruising through rough waves in your electrical network

UPS Uninterruptible Power System

THE COMPREHENSIVE APPROACH TO FACILITY POWER QUALITY

PQ Monitoring Standards

UNINTERRUPTIBLE POWER SUPPLY SPECIFICATIONS MODEL 1100B SERIES

Est Triplen Power Distribution Unit TPDU kVA

QualityMonitoring. range Ease of Installation Non Intursive Ease of Installation Non Intursive. Power Quality Parameters. Modular Wireless Achitecture

Harmonic distortion Blackouts Under or over voltage Dips (or sags) and surges, Transients.

CLP0205 Open Frame Power Supply Vac input; 5Vdc output; 200W Output Power; 0.25A stdby

Presents. Harmonics Years

DOBLE F6150e TECHNICAL SPECIFICATIONS

Motors and drives. Module B- Introduction to input measurements

CHAPTER 5 POWER QUALITY IMPROVEMENT BY USING POWER ACTIVE FILTERS

Drives 101 Lesson 5. Power Input Terminology for a VFD

PowerMonitor 5000 Family Advanced Metering Functionality

SGMF(T) series. Onsite Mobile AC High Voltage Test System. Applications:

Transcription:

conditioning products Electronic voltage regulator -Sure 700 & 800 -Suppress T7 & 100 Harmonic correction unit Sag ride-through power conditioner The power to work

Basics of power quality The partner you can trust The PQ PyramidE The key elements of an effective PQ strategy: Interruption solutions Reduce problems associated with outages using UPS, paralleling switchgear, generators and/or energy storage devices Harmonic mitigation Many applications require solutions to reduce harmonic current and voltage distortion Voltage regulation Stabilizes a facility s voltage and eliminates costly problems due to undervoltage and overvoltage events Surge protection Eliminates problems associated with transients traveling on AC, telephone and communication lines Effective grounding A well-designed and properly installed grounding system is required for safety and operation of all electrical equipment Utilities struggle to keep up with the unrelenting demand for clean power you can t rely solely on them to provide it. The responsibility for PQ rests with the customer including you. With Eaton behind you, your company s operations managers and facility engineers can be assured that their power supply will get the job done, no matter what level of reliability your company requires. You wouldn t use anything other than 100 percent clean gas in your car, or pure oil in your engine. The same rules apply to your electrical equipment. Without an investment in the quality of power running this equipment, you can expect downtime and equipment disruption. Outages Interruptions Harmonic Distortion Voltage Variations and Sags High $/kva Solution Voltage Surges rounding/ Bonding PQ Pyramid Low $/kva Solution 2 EATON conditioning products

A total solution The right power quality solution is site and industry specific. quality meters are required to help you capture and analyze your facility s power disturbances. If you can t measure it, you can t manage it. Predictive Diagnostics/ Partial Discharge Protective Relays Transfer Switches Harmonic Mitigating Transformer K-Factor Transformer Grounding and Lighting Systems A power quality engineer can help companies interpret data and identify the most cost-effective solutions. With today s increasingly complex facilities and interconnected networks, the number of problems that can result from poor power quality are significant. Eaton power system engineers are PQ experts who can help you realize the full benefits of your investment. Armed with this information, you can select the Eaton product that is right for you. Uninterruptible Supply Other Harmonic Solutions Surge Isolation Transformers Sag Correction Voltage Regulation Quality Meters Factor Correction Distribution Generation Switchgear EATON conditioning products 3

Solutions to all of your power quality needs An investment in Eaton power quality (PQ) solutions is one that will pay dividends immediately. It keeps your equipment, and your company, working. That means you avoid costly downtime. We ll help you protect your investment in an increasingly digital world. Overview Eaton offers a wide range of power conditioning solutions. These solutions range from small single-phase isolation units to megawatt sag correction units. Eaton has the engineering expertise and products to solve any power quality problem. Protects equipment from: Voltage sags Line noise Voltage transients/surges Under/overvoltage events Swells Harmonics Ratings 500 VA to 50 MVA 50/60 Hz Voltage 120V to 36 kv Single-phase and three-phase 4 EATON conditioning products

conditioning product selection chart Eaton power conditioning products are designed to protect your critical equipment against common power quality problems. Quality Product / Uninterruptible power supply Transient Activity Noise Suppression Voltage Regulation Voltage Sag Correction Harmonic Interruption n n n n n n Isolation Electronic voltage n n n n n regulators (EVR) -SureE 700 n n n n n -Sure 800 n n n n n -Suppress 100 n n n -Suppress T7 n n Surge protective devices n n Sag ride-through devices (SRT2) n n n Harmonic correction n units (HCU) Factor Correction n conditioning application chart Quality Product / Application Single-Phase Three-Phase Uninterruptible power supply Test Equipment Audio Systems Data Centers Interruption Isolation Factory Automation Critical Systems n n n n n n n Electronic voltage n n n n n regulators (EVR) -Sure 700 n n n n n -Sure 800 n n n n n -Suppress 100 n n n n n -Suppress T7 n n n Surge protective devices n n n n n n n Sag ride-through devices (SRT2) n n n n Harmonic correction units (HCU) n n n n EATON conditioning products 5

conditioning voltage regulators EVR and -Sure 700 three-phase -Sure 800 single-phase Sag ride-through power conditioner (SRT2) Ratings from 10 to 500 kva Voltage from 208V to 600V Seven taps per phase for optimal regulation Response time of 1/2 cycle Output correction within 1.5 cycles ±3% voltage output for a +10% to 23% voltage input Less than 1% THD Unit not affected by load power factor High efficiency of approximately 97% Frequency range of 53 63 Hz Bypass switch (optional on 45 kva and smaller units) Triple-shielded isolation transformer Overtemperature protection Optional surge protection unit Optional metering Front access only for 50 150 kva units One-year warranty Ratings from 500 VA to 25 kva Voltage range from 120V to 480V Office models (with receptacles) Hardwired models (wall/panel mount and floor mount) Line regulation ±3% V-out for +10% to 20% V-in at 100% load Load regulation ±3% for 0 75% load to ±2% for 100% load Immunity to distortion at 40% THD V-in, 5% max. THD V-out Ride-through capability of 1 cycle Voltage recovery of 2 cycles to 95%, 3 cycles to 100% K-30 rated K-factor Harmonic attenuation of 23 db for load-reflected harmonics Surge protection of 330V let-through voltage Common mode noise attenuation of 140 db Up to 30 seconds of voltage sag ride-through 99% efficient (typical) Does not lower fault capacity Continuous voltage regulation Voltage harmonic reduction Voltage balance correction Extensive diagnostics Voltage event log Separate coupling transformer Continuous sag correction survives multiple sag events without recharging capacitors for extra time savings Small design and footprint significantly reduces required floor space Battery-free design eliminates costly maintenance and disposal requirements No minimum load improves operating flexibility for fluctuating loads or processes Sub-cycle response patented circuit enables extremely fast 2 ms response (1/8 cycle) Electronic Voltage Regulator and -Sure 700 -Sure 800 Transverse mode noise attenuation of 120 db Reliability of 200,000 hours (MTBF) Audible noise of 52 56 db at 1 meter Efficiency of 92% at full load Operating temperature of 20 C to +40 C Two-year warranty Sag Ride-Through (SRT2) 6 EATON conditioning products

conditioning and isolation Harmonic Correction Unit -Suppress 100 single-phase Traps unwanted harmonics Sizes from 500 VA to 7.5 kva Voltages from 120V to 480V Common mode noise attenuation of 140 db at 100 khz Normal mode noise attenuation of 65 db at 100 khz Overload capacity of 600% for 1 cycle, 300% for 30 seconds Frequency of 60 Hz ±5% Efficiency of 93 97% Adds less than 1% THD under linear loading Temperature rise 115 C above a 40 C ambient Removes surge voltages and minimizes reflected THD Cleans and conditions the sine wave -Suppress T7 isolation transformer 20,000,000:1 (146 db) common-mode noise attenuation Typically 1000 to 1 (60 db) normal-mode noise attenuation Transient suppression system with status indicators Exclusive shielding K-13 rated Overtemperature protection Clean, noise-free power output High efficiency Fast, easy installation UL and cul listed requirements Five-year warranty Harmonic correction unit Can be sized to guarantee specific levels of harmonic correction, such as meeting IEEE 519 recommended levels Cannot be overloaded Can be expanded without affecting performance Broad spectrum of cancellation (2nd to 50th harmonic) factor improvement Easier and less expensive installation Comprehensive control Fast action 20 khz switching carrier frequency, 8 ms full response time UL/CSA approved 208 480V ±10%, 600V with autotransformer 50/60 Hz ±3 Hz frequency Eliminates load-generated feedback Ambient temperature 0 C to +40 C enclosed -Suppress 100 Available in both hardwired or line cord/receptacle models Fast and easy installation Long-life operation Small footprint Two-year warranty Seismic Zone 4 NEMA 1 and NEMA 12 enclosures available: Wallmount (50 and 100A designs) Floor-standing (300A design) Output capacity self-limited to 100% current rated Corrective capability <5% TDD and near unity displacement power factor Two-line, 20-character-per-line alphanumeric display Requires at least 3% series input line reactor ahead of large nonlinear loads. EATON conditioning products 7

Eaton is dedicated to ensuring that reliable, efficient and safe power is available when it s needed most. With unparalleled knowledge of electrical power management across industries, experts at Eaton deliver customized, integrated solutions to solve our customers most critical challenges. Our focus is on delivering the right solution for the application. But, decision makers demand more than just innovative products. They turn to Eaton for an unwavering commitment to personal support that makes customer success a top priority. For more information, www.eaton.com/pc. For application support, call our engineers at 800-809-2772, option 4, sub-option 2. For details, visit www.eaton.com/pc. Eaton 1000 Eaton Boulevard Cleveland, OH 44122 United States Eaton.com 2014 Eaton All Rights Reserved Printed in USA Publication No. BR158001EN / Z14617 March 2014 Eaton is a registered trademark. All other trademarks are property of their respective owners.