LED Driver Compact fixed output

Similar documents
PHASED OUT. LED Driver Compact fixed output. Driver LCI 20W 350mA 900mA TOP C TOP series

PHASED OUT. LED Driver Compact fixed output. Driver LCI 10W 150mA 400mA TOP C TOP series. Product description

PHASED OUT. LED Driver Compact fixed output. Driver LCI 10W 350mA 900mA TOP C TOP series

PHASED OUT. LED Driver Linear / area fixed output. Driver LCI 35W 350mA 900mA TOP lp TOP series

PHASED OUT. LED Driver Linear / area fixed output. Driver LCI 20W 150mA 400mA TOP lp TOP series. Product description

PHASED OUT. LED Driver Compact dimming. Driver LCAI 55W 900mA 1750mA ECO C ECO series

LED Driver Compact dimming

PHASED OUT. LED Driver Compact dimming. Driver LCAI 55W 900mA 1750mA ECO SR ECO series

LED Driver Linear / area fixed output

LED Driver Linear / area dimming

LED Driver Compact fixed output

PHASED OUT. LED Driver Compact dimming. Driver LCAI 20W 350mA 900mA ECO SR ECO series

PHASED OUT. LED Driver Linear / area dimming. Driver LCAI 100W 350mA 900mA ECO INDUSTRY sl ECO series

LED Driver Compact dimming

LED control gear Linear / area fixed output

PHASED OUT. LED Driver Linear / area dimming. Driver LCAI 20W 150mA 400mA ECO lp ECO series

LED Driver Linear / area fixed output

LED Driver Compact fixed output 4,5 83,5 93. Ordering data. Type

PHASED OUT. LED Driver Linear / area dimming. Driver LCAI 20W 350mA 550mA ECO lp ECO series

LED Driver Constant voltage. Driver LC 100W 24V lp SNC ESSENCE series

LED Driver Constant voltage. Driver LC 60W 24V lp SNC ESSENCE series

LED Driver Linear / area dimming. Udriver LCAI 20W 350mA 550mA ECO lp ECO series

LED Driver Compact fixed output

LED Driver Compact fixed output

LED Driver Linear / area dimming

LED Driver Constant voltage. Driver LC 100W 24V lp SNC ESSENCE series

LED Driver Compact fixed output. Udriver LC 25/30/35/40W 600/700/800/900mA fixc SC ADV ADVANCED series

LED Driver Compact dimming

LED Driver Compact fixed output

LED Driver Compact fixed output. Udriver LC 15/20/25W 350/500/700/600mA fixc C SNC ESSENCE series

LED Driver Compact fixed output

LED Driver Compact fixed output

LED Driver Compact dimming

LED Driver Compact fixed output

Emergency lighting units EM powerled

LED Driver Constant voltage

LED Driver Linear / area dimming

basicdim Wireless basicdim Wireless LED Drivers

LED Driver Compact dimming

LED Driver Constant voltage

LED Driver Constant voltage

LED Driver Constant voltage

LED Driver Linear / area dimming

Emergency lighting units EM powerled

LED control gear Compact fixed output. Uconverter LCI 20 W 350/500/700 ma TEC SR TEC series

LED Driver Constant voltage

LED Driver Constant voltage. Driver LC 100W 24V SC SNC ESSENCE series

LED Driver Constant voltage

LED Driver Compact fixed output

LED Driver Constant voltage

LED Driver Compact fixed output

PHASED OUT. LED Driver Compact fixed output. Driver LC 20W 500/700mA fixc SR SNC ESSENCE series

LED Driver Constant voltage. Udriver LCA 100W 24V one4all SC PRE PREMIUM series

LED Driver Constant voltage

LED control gear Compact dimming. Uconverter LCBI 10 W 180/350/500 ma phase-cut/1 10 V lp BASIC series

LED Driver Compact dimming

LED Driver Constant voltage

LED Driver Constant voltage. Udriver LCU 60W 12/24V IP67 EXC EXCITE outdoor IP67 series

LED Driver Compact dimming outdoor

LED Driver Compact dimming outdoor

LED Driver Constant voltage

LED Driver Compact dimming outdoor

LED Driver Compact dimming outdoor

LED converter Linear / area dimming. Uconverter LCAI 80 W 350 ma one4all V ECO

FL ballasts Electronic dimming. PCA T8 EXCEL one4all lp Y II, W EXCEL T8

FL ballasts Electronic dimming. PCA T8 ECO lp Y II, W ECO T8

TD - Power Supply LP DALI&Switch Dim Mono PRE (CV) MM-IP20 User Manual

FL ballasts Electronic dimming. PCA T5 EXCITE lp Y, 3 and 4x14/24 W EXCITE T5

FL ballasts Electronic dimming. PCA T8 ECO lp Y, 3x18 W and 4x18 W ECO T8

FL ballasts Electronic dimming. PCA T5 ECO lp Y, 3x14/24 W and 4x14/24 W ECO T5

LED converter Compact dimming. Uconverter LCAI 55 W 1400 ma O010 DALI ECO series Ø4,4. Ordering data

PCA ECO lp Y, W T8 fluorescent lamps

LED control gear Compact fixed output. Uconverter LCI 50 W 1050 ma N020 TOP series Ø4,5. Ordering data

ZITARES NCD FX-30 Non-SELV (isolated), constant current control gear, 1-channel, dimmable

LED catalogue Issue October 2013

AC modules LED compact

ZITARES CCD 2 nd Generation SELV constant current control gear, 1-channel, dimm- and adjustable

basicdim Wireless Casambi Ready

ZITARES NCD FX-30 Non-SELV (isolated), constant current control gear, 1-channel, dimmable

Tunable White LED linear / area

OT FIT 15/ /500 LT2 LP

ZITARES NCD 2 nd Generation Non-SELV, constant current control gear, 1-channel, dimmable

ZITARES CCD FX-20 25W SELV (isolated), adjustable functions and current, 1-channel, dimmable

ZITARES ICD SELV constant current control gear, 2-channel, dimm- and programmable

PCA T8 EXCEL one4all lp Y, W T8 fluorescent lamps

LC35/2-DA-iC. 35 W Dimmable two channel intelligent Colour LED driver. 35 W V 0 / Hz. Functional Description. Mains Characteristics

ZITARES CC Constant current control gear, 2-channel, dimmable

COMPACT LED DRIVERS. ComfortLine Selectable Current (LEDset) ComfortLine SELECTABLE CURRENT LEDset ,

PHASED OUT. Digital dimmable ballasts for fluorescent lamps EXCEL series. PCA TCL EXCEL one4all lp Y, 55 W Compact and T5c fluorescent lamps

ZITARES CC Constant current control gear, 1-channel, dimmable

ZITARES ICD SELV constant current control gear, 2-channel, dimm- and programmable

ZITARES NCS 2 nd Generation Non-SELV, Constant current control gear, 1-channel, non-dimmable

Lighting Controls and Connectivity basicdim. basicdim Wireless PWM CV 4CH Wireless module for basicdim

ZITARES LCS Non-SELV, Constant current control gear, 1-channel, non-dimmable

PHASED OUT. LED light engine / OLED LED compact. Module SLE G5 ADV Modules SLE ADVANCED

U LED modules, converters and systems CONVERTER. Uconverter LCAI 50 W 1050 ma N020 DALI uconverter REMOTE LCI

OPTOTRONIC Intelligent

OTi DALI 80/ / CH OTi DALI 50/ / CH

PHASED OUT. LED light engine / OLED LED linear / area. Umodule STARK INDI CLASSIC STARK INDI

Features. LED Driver RACT Watt. TRIAC Dimmable. Single Output RACT12- AC/DC Converter

Transcription:

w LED Driver Driver LCI 100W 900mA 1750mA TOP C TOP series Product description Fixed output built-in LED Driver Constant current LED Driver Output current settable 900 1,750 ma Max. output power 100 W Suitable for mains voltage peaks (burst/surge) up to 4 kv (L N) respectively 3 kv (L/N PE) Nominal life-time up to 100,000 h For luminaires of protection class I and protection class II 5-year guarantee Properties Casing: polycarbonate, white Type of protection IP20 Functions Intelligent Temperature Guard (overtemperature protection) Intelligent Temperature Management (temperature monitoring of LED module) Short-circuit proof Overload protection Suitable for emergency escapge lighting systems acc. to EN 50172 È Standards, page 5 www.tridonic.com 1

EL Driver LCI 100W 900mA 1750mA TOP C TOP series Technical data Rated supply voltage 220 240 V AC voltage range 198 264 V DC voltage range 176 280 V (start 198 V DC) Mains frequency 0 / 50 / 60 Hz Overvoltage protection 320 V AC, 48 h Leakage current (PE) < 0.5 ma Max. input power 108.7 W Efficiency (at 230 V, 50 Hz, full load) 92 % THD (at 230 V, 50 Hz, full load) < 10 % Output current tolerance ± 5 % Output LF current ripple (< 120 Hz) < 3 % Max. peak output current Output current + 20 % Max. output voltage (no-load voltage) 120 V Time to light < 0.5 s Hold on time at power failure or switch-off < 15 ms Switchover time (AC/DC) < 0.5 s Burst / surge peaks output side against PE 2 kv Dimensions L x W x H 140 x 100 x 30 mm 5 tc 18 Ordering data Type 130 140 5 30 80 90 100 Article number 4.2 Packaging carton Packaging pallet Weight per pc. LCI 100W 900mA-1750mA TOP C 28000203 10 pc(s). 500 pc(s). 0.28 kg Specific technical data Type LCI 100W 900mA-1750mA TOP C Output current Min. forward voltage 1 Max. forward Max. output voltage power Input power (at 230 V, 50 Hz, full load) Input current (at 230 V, 50 Hz, full load) λ (at 230 V, 50 Hz, full load) tc point Ambient temperature ta tc/ta for 50.000 h I sel resistor value 900 ma 50 V 85.0 V 76.5 W 83.2 W 369 ma 0.98 70 C -25... +55 C 70 / 55 C open circuit 950 ma 47 V 85.0 V 80.8 W 87.8 W 389 ma 0.98 70 C -25... +55 C 70 / 55 C 69.80 kω 1,000 ma 45 V 85.0 V 85.0 W 92.4 W 410 ma 0.98 70 C -25... +55 C 70 / 55 C 64.90 kω 1,050 ma 43 V 85.0 V 89.3 W 97.0 W 430 ma 0.98 75 C -25... +50 C 75 / 50 C 56.00 kω 1,100 ma 41 V 85.0 V 93.5 W 101.6 W 451 ma 0.98 75 C -25... +50 C 75 / 50 C 47.50 kω 1,150 ma 39 V 85.0 V 97.8 W 106.3 W 471 ma 0.98 75 C -25... +50 C 75 / 50 C 43.20 kω 1,200 ma 38 V 83.3 V 100.0 W 108.7 W 482 ma 0.98 75 C -25... +50 C 75 / 50 C 40.20 kω 1,250 ma 36 V 80.0 V 100.0 W 108.7 W 482 ma 0.98 75 C -25... +50 C 75 / 50 C 36.50 kω 1,300 ma 35 V 76.9 V 100.0 W 108.7 W 482 ma 0.98 75 C -25... +50 C 75 / 50 C 32.40 kω 1,350 ma 33 V 74.1 V 100.0 W 108.7 W 482 ma 0.98 75 C -25... +50 C 75 / 50 C 28.70 kω 1,400 ma 32 V 71.4 V 100.0 W 108.7 W 482 ma 0.98 75 C -25... +50 C 75 / 50 C 22.00 kω 1,450 ma 31 V 69.0 V 100.0 W 108.7 W 482 ma 0.98 75 C -25... +50 C 75 / 50 C 17.80 kω 1,500 ma 30 V 66.7 V 100.0 W 108.7 W 482 ma 0.98 75 C -25... +50 C 75 / 50 C 15.00 kω 1,550 ma 29 V 64.5 V 100.0 W 108.7 W 482 ma 0.98 75 C -25... +50 C 75 / 50 C 12.10 kω 1,600 ma 28 V 62.5 V 100.0 W 108.7 W 482 ma 0.98 75 C -25... +50 C 75 / 50 C 9.30 kω 1,650 ma 27 V 60.6 V 100.0 W 108.7 W 482 ma 0.98 75 C -25... +50 C 75 / 50 C 6.49 kω 1,700 ma 26 V 58.8 V 100.0 W 108.7 W 482 ma 0.98 75 C -25... +50 C 75 / 50 C 3.83 kω 1,750 ma 26 V 57.1 V 100.0 W 108.7 W 482 ma 0.98 75 C -25... +50 C 75 / 50 C short circuit 1 Min. output voltage LED Driver is 26 V by using the accessory LCF 12V FAN DRIVER. www.tridonic.com 2

ACCES- SORIES I-SELECT PLUG Product description Ready-for-use resistor to set output current value Resistor is base isolated Resistor power 0.25 W Resistor value tolerance ± 1 % 5,5 3,5 xxxx 13,5 6 9 3,5 Ordering data Type Article number Colour Marking Resistor value Packaging bag Weight per pc. I-SELECT PLUG 950mA BR 28000370 Brown 0950 69.80 kω 10 pc(s). 0.001 kg I-SELECT PLUG 1000mA BR 28000459 Brown 1000 64.90 kω 10 pc(s). 0.001 kg I-SELECT PLUG 1050mA BR 28000279 Brown 1050 56.00 kω 10 pc(s). 0.001 kg I-SELECT PLUG 1100mA BR 28000460 Brown 1100 47.50 kω 10 pc(s). 0.001 kg I-SELECT PLUG 1200mA BR 28000461 Brown 1200 40.20 kω 10 pc(s). 0.001 kg I-SELECT PLUG 1300mA BR 28000462 Brown 1300 32.40 kω 10 pc(s). 0.001 kg I-SELECT PLUG 1400mA BR 28000280 Brown 1400 22.00 kω 10 pc(s). 0.001 kg I-SELECT PLUG 1500mA BR 28000464 Brown 1500 15.00 kω 10 pc(s). 0.001 kg I-SELECT PLUG 1600mA BR 28000465 Brown 1600 9.30 kω 10 pc(s). 0.001 kg I-SELECT PLUG 1700mA BR 28000466 Brown 1700 3.83 kω 10 pc(s). 0.001 kg I-SELECT PLUG MAX GR 28000274 Grey MAX 0 Ω 10 pc(s). 0.001 kg www.tridonic.com 3

ACCES- SORIES LCF 12V FAN DRIVER Product description Fan driver module with 12.4 V output voltage Drives the fan permanently (independent of the optional temperature sensor) Terminal IN1 / IN2: stranded wires 0.2 mm², stripped wire endings twisted and tin-plated Terminal FAN+ / FAN and OUT1 / OUT2: 0.2 0.75 mm² solid or stranded wires twisted and tin-plated, strip wires 6 7 mm Max. output power of the LED Driver will be reduced by the power consumption of the fan and LCF 12V FAN DRIVER Technical data Input voltage, DC 25 120 V Output voltage DC 12.4 V Max. output current (input voltage 25 49 V) 50 ma Max. output current (input voltage 50 120 V) 70 ma Max. power consumption incl. fan (at 30 ma) 0.55 W Max. power consumption incl. fan (at 50 ma) 0.90 W Max. power consumption incl. fan (at 70 ma) 1.25 W tc point 75 C Ambient temperature ta (at life-time 50,000 h) -25... +65 C Dimensions LxWxH 45 x 23 x 14 mm 23 21 41 15 FAN+ IN1 FAN tc red OUT1 shrink tube OUT2 IN2 black 45 7 4 Ordering data Type Article number Packaging carton Packaging pallet Weight per pc. LCF 12V FAN DRIVER 28000932 50 pc(s). 1,200 pc(s). 0.01 kg 58 www.tridonic.com 4

Standards EN 55015 EN 61000-3-2 EN 61000-3-3 EN 61347-2-13 EN 62384 EN 61547 According to EN 50172 for use in central battery systems According to EN 60598-2-22 suitable for emergency lighting installations Housing fulfils requirements for reinforced insulation according EN 60598-1. Output current setting Output current can be set by connecting a resistor between the 2 I sel terminals. Relationship between output current and resistor value can be found at the table Specific technical data. Resistor values specified from standardised resistor value ranges. Resistor value tolerance has to be 1 %. Resistor power has to be 0.1 W. If the resistor is connected with wires a max. wire length of 2 m may not be exceeded and possible interferences have to be avoided. Resistor detection at each start. Change of the resistor value during the operation will be not considered. Resistors for the main output current values can be ordered from Tridonic (see accessories). DC emergency operation The LED Driver is designed for operation on DC voltage and pulsed DC voltage. Light output level in DC operation: 100 % The voltage-dependent input current of Driver incl. LED module is depending on the used load. The voltage-dependent no-load current of Driver (without or defect LED module) is for: AC: < 30 ma DC: < 5 ma Overload protection LED Driver will switch off at overload operation. Mains reset is required to restart the LED Driver. Underload operation LED Driver will switch off at underload operation. Mains reset is required to restart the LED Driver. Overtemperature protection The LED Driver will reduce output current at temporary thermal over-heating (exceeding max. tc point). On DC operation this function is deactivated to fulfill emergency requirements. Short-circuit behaviour LED Driver will switch off in case of short-circuit of LED output. Mains reset is required to restart the LED Driver. No-load operation or load loss during operation LED Driver will detect a load loss during operation. In this case and no-load operation the max. output voltage can apply at the LED output for max. 5 s before LED Driver shuts down. Mains reset is required to restart the LED Driver. Hot plug-in Hot plug-in is not recommend within 5 s after shutdown due to output voltage of > 0 V. Mains reset is required to restart the LED Driver if LED module is connected to the LED Driver after these 5 s. Intelligent Temperature Management (ITM) ITM offers the possibility to protect the LED module against thermal overload. Therefore it is necessary to connect the temperature sensor (KTY81/210, KTY82/210) to the corresponding terminals. If the limit temperature wil be exceeded the LED output current will be reduced respectively switched off. After achieving the nominal temperature the LED output current will be encreased to the set value again. Using NTC or PTC resistors is not permitted. The LED Driver can be used without sensor as well. Conditions of use and storage Humidity: 5 % up to max. 85 %, not condensed (max. 56 days/year at 85 %) Storage temperature: -40 C up to max. +80 C The devices have to be within the specified temperature range (ta) before they can be operated. Glow-wire test according to EN 61347-1 with increased temperature of 960 C passed. Temperature range The LED Driver life duration is related to the ambient temperature ta. The relation of tc to ta temperature depends also on the luminaire design. If the measured tc temperature is approx. 5 K below tc max. or higher, ta temperature should be checked and eventually critical components (e.g. ELCAP) measured. Detailed information on request. Expected life-time Type Output current ta 40 C 50 C 55 C 60 C LCI 100W 900mA-1750mA TOP C x = not permitted 900 1,000 ma 1,050 1,750 ma tc 55 C 65 C 70 C x Life-time > 100,000 h > 100,000 h > 100,000 h x tc 65 C 75 C x x Life-time > 100,000 h > 100,000 h x x The LED Driver is designed for a life-time stated above under reference conditions and with a failure probability of less than 10 %. Maximum loading of automatic circuit breakers Automatic circuit breaker type C10 C13 C16 C20 B10 B13 B16 B20 Inrush current Installation Ø 1,5 mm 2 1,5 mm 2 2,5 mm 2 2,5 mm 2 1,5 mm 2 1,5 mm 2 2,5 mm 2 2,5 mm 2 I max time LCI 100W 900mA-1750mA TOP C 12 18 28 30 6 9 14 15 50 A 200 μs Harmonic distortion in the mains supply (at 230 V / 50 Hz and full load) in % THD 3. 5. 7. 9. 11. LCI 100W 900mA-1750mA TOP C < 10 3 2 2 2 2 www.tridonic.com 5

LED Driver Installation instructions Wiring type and cross section The wiring can be in stranded wires with ferrules or solid with a cross section of 0.5 1.5 mm² for mains wires and 0.2 1.5 mm² for secondary wires. Strip 9.5 mm of insulation from the cables to ensure perfect operation of the push-wire terminals. Use one wire for each terminal connector only. Circuit diagram 220 240 V 0/50/60 Hz L N wire preparation: 0.2 1.5 mm² 8.5 9.5 mm Release of the wiring Press down the push button and remove the cable from front. PRI SEC + LED LED I sel 1 I sel 2 ITM 1 ITM 2 KTY81/210 KTY82/210 R 220 240 V 0/50/60 Hz L N Mounting of device Max. torque for fixing: 0.5 Nm/M4 Wiring guidelines All connections must be kept as short as possible to ensure good EMI behaviour. Earthing is not required for the device to operate but will improve the EMI behaviour. If LCI TOP C will be earthed protection earth (PE) has to be used. Mains leads should be kept apart from LED Driver and other leads (ideally 5 10 cm distance) Max. length of output and I sel wires is 2 m. Secondary switching is not permitted. Incorrect wiring can demage LED modules. The wiring must be protected against short circuits to earth (sharp edged metal parts, metal cable clips, louver, etc.). Earth connection The earth connection is conducted as protection earth (PE). If the LED Driver will be earthed, protection earth (PE) has to be used. There is no earth connection required for the functionality of the LED Driver. Earth connection is recommended to improve following behaviour. Electromagnetic interferences (EMI) Transmission of mains transients to the LED output In general it is recommended to earth the LED Driver if the LED module is mounted on earthed luminaire parts respectively heat sinks and thereby representing a high capacity against earth. PRI Isolation and electric strength testing of luminaires Electronic devices can be damaged by high voltage. This has to be considered during the routine testing of the luminaires in production. According to IEC 60598-1 Annex Q (informative only!) or ENEC 303-Annex A, each luminaire should be submitted to an isolation test with 500 V DC for 1 second. This test voltage should be connected between the interconnected phase and neutral terminals and the earth terminal. The isolation resistance must be at least 2 MΩ. As an alternative, IEC 60598-1 Annex Q describes a test of the electrical strength with 1500 V AC (or 1.414 x 1500 V DC). To avoid damage to the electronic devices this test must not be conducted. SEC IN2 LCF 12V FAN DRIVER IN1 + LED LED I sel 1 I sel 2 ITM 1 ITM 2 OUT2 OUT1 FAN FAN+ KTY81/210 KTY82/210 R + FAN Additional information Additional technical information at www.tridonic.com Technical Data Guarantee conditions at www.tridonic.com Services Life-time declarations are informative and represent no warranty claim. No warranty if device was opened. www.tridonic.com 6

Diagrams LCI 100W 900mA-1750mA TOP C Efficiency vs load Power factor vs load 93 0,99 92 91 0,98 Efficiency [%] 90 89 88 87 Power factor 0,97 0,96 0,95 86 85 0,94 Input power vs load Input current vs load 120 600 100 500 Input power [W] 80 60 40 Input current [ma] 400 300 200 20 100 0 0 THD vs load 9 8 THD 7 6 5 4 900 ma 1050 ma 1400 ma 1750 ma 3 2 1 0 www.tridonic.com 7