DSP-BASED INSTRUMENT FOR POWER QUALITY MONITORING ON SHIPS

Similar documents
DWT ANALYSIS OF SELECTED TRANSIENT AND NOTCHING DISTURBANCES

Frequency characteristic of transients and notching disturbances case study. Mariusz Szweda 1, Tomasz Tarasiuk 2

A POWER QUALITY INSTRUMENT FOR HARMONICS INTERHARMONICS AND AMPLITUDE DISTURBANCES MEASUREMENTS

Monitoring of Power Quality in Industry

Virtual FFT Analyser for identification of harmonics and inter-harmonics metrological aspects

On the methodologies for the calibration of static electricity meters in the presence of harmonic distortion

PLL AND NUMBER OF SAMPLE SYNCHRONISATION TECHNIQUES FOR ELECTRICAL POWER QUALITY MEASURMENTS

Measurement of RMS values of non-coherently sampled signals. Martin Novotny 1, Milos Sedlacek 2

UNIT-4 POWER QUALITY MONITORING

Wavelet Transform Based Islanding Characterization Method for Distributed Generation

Interharmonic Task Force Working Document

Power Quality Measurements the Importance of Traceable Calibration

Power Quality Notes 3-2 (MT)

Programming PC-Based Multi-Function Oscilloscopes: A User-Friendly Approach to Rapid Prototyping of Spectral Analysis Code

A NEW MOTOR SPEED MEASUREMENT ALGORITHM BASED ON ACCURATE SLOT HARMONIC SPECTRAL ANALYSIS

p. 1 p. 6 p. 22 p. 46 p. 58

HIGHLY ACCURATE CALIBRATION SYSTEM FOR ELECTRONIC INSTRUMENT TRANSFORMERS

CHARACTERIZATION ISSUE OF POWER QUALITY INSTRUMENTS

C.A Complete electrical network analysis at the tips of your fingers! Power Quality Monitor. Keeping up with the standards

A COMPARATIVE ANALYSIS IN TERMS OF CONDUCTED SUSCEPTIBILITY OF PC-BASED DATA ACQUISITION SYSTEMS

Power Quality Analysers

Techniques used for Detection of Power Quality Events a Comparative Study C. Venkatesh, Student Member, IEEE, D.V.S.S. Siva Sarma, Senior Member, IEEE

SIGNAL PROCESSING OF POWER QUALITY DISTURBANCES

The series allows users to compose. amplify the analog signal from arbitrary signal generator. Thus, it is capable of simulating the

METHOD OF TESTING AND CORRECTING SIGNAL AMPLIFIERS TRANSFER FUNCTION USING PRONY ANALYSIS

Power Quality and Digital Protection Relays

Realization and characterization of a smart meter for smart grid application

Digital microcontroller for sonar waveform generator. Aleksander SCHMIDT, Jan SCHMIDT

Detection, localization, and classification of power quality disturbances using discrete wavelet transform technique

H e s s o. Laboratory Experiments

Design Requirements for a Dynamic Voltage Restorer for Voltage Sags Mitigation in Low Voltage Distribution System

PQ Monitoring Standards

APPLICATION NOTE INTERHARMONICS

EFFECT OF INTEGRATION ERROR ON PARTIAL DISCHARGE MEASUREMENTS ON CAST RESIN TRANSFORMERS. C. Ceretta, R. Gobbo, G. Pesavento

MULTIFUNCTION POWER QUALITY MONITORING SYSTEM

Study on Reactive Automatic Compensation System Design

PROGRAMMABLE AC POWER SOURCE

2) APRV detects and records low frequency events (voltage drop, over-voltages, wave distortion) with a sampling frequency of 6400 Hz.

Detection and Localization of Power Quality Disturbances Using Space Vector Wavelet Transform: A New Three Phase Approach

We are IntechOpen, the world s leading publisher of Open Access books Built by scientists, for scientists. International authors and editors

VARIABLE-FREQUENCY PRONY METHOD IN THE ANALYSIS OF ELECTRICAL POWER QUALITY

Power Conditioning Equipment for Improvement of Power Quality in Distribution Systems M. Weinhold R. Zurowski T. Mangold L. Voss

COMPARATIVE ANALYSIS OF DIFFERENT ACQUISITION TECHNIQUES APPLIED TO STATIC AND DYNAMIC CHARACTERIZATION OF HIGH RESOLUTION DAC

Data Acquisition Systems. Signal DAQ System The Answer?

ARM BASED WAVELET TRANSFORM IMPLEMENTATION FOR EMBEDDED SYSTEM APPLİCATİONS

A Power Quality Survey on a 22 kv Electrical Distribution System of a Technical Institution as per Standards

New Features of IEEE Std Digitizing Waveform Recorders

Metrol. Meas. Syst., Vol. XIX (2012), No. 4, pp METROLOGY AND MEASUREMENT SYSTEMS. Index , ISSN

Field Programmable Gate Array-Based Pulse-Width Modulation for Single Phase Active Power Filter

Chapter 2 Analog-to-Digital Conversion...

FFT Analyzer. Gianfranco Miele, Ph.D

ANALYSING PERFORMANCE OF SUPER-CAPACITOR AND BATTERY IN LOW VOLTAGE ELECTRICAL DISTRIBUTION SYSTEMS

Approaching E_Learning on Three-Phase System Measurements

EEE508 GÜÇ SİSTEMLERİNDE SİNYAL İŞLEME

Advanced Software Developments for Automated Power Quality Assessment Using DFR Data

MITIGATION OF POWER QUALITY DISTURBANCES USING DISCRETE WAVELET TRANSFORMS AND ACTIVE POWER FILTERS

Active Elimination of Low-Frequency Harmonics of Traction Current-Source Active Rectifier

Specification for a Fully Automatic Meter Test Equipment for testing Three-phase/Single/Transformer operated/ reference Standard energy meters.

EXPERIMENTAL RESEARCH OF AN INDUCTIVE DYNAMIC DRIVE FOR DIFFERENT COIL POWER SUPPLY SYSTEMS

SITE-TO-SITE REPRODUCIBILITY IN CONDUCTED IMMUNITY TESTS ON PC-BASED DATA ACQUISITION SYSTEMS

Low distortion signal generator based on direct digital synthesis for ADC characterization

Voltech PM3000ACE UNIVERSAL POWER ANALYZER

Application of Instrument Transformers in Power Quality Assessment

REGENERATIVE GRID SIMULATOR MODEL SERIES MODEL SERIES. Regenerative Grid Simulator. Key Features

Alexandre A. Carniato, Ruben B. Godoy, João Onofre P. Pinto

Power Meter PW3335. Ken Sakai Engineering Division 4, Engineering Department. Power Meter PW3335

Application of Hilbert-Huang Transform in the Field of Power Quality Events Analysis Manish Kumar Saini 1 and Komal Dhamija 2 1,2

Interference assessment: Comparison of reed track circuit computer model and DFT based analysis

Power Quality Improvement using Hysteresis Voltage Control of DVR

MEASUREMENT METHODS OF THE CHARACTERISTICS AND TARGET VALUES OF THE VOLTAGE QUALITY SUPPLIED BY HYDRO-QUEBEC SYSTEM

Advanced Digital Signal Processing Part 2: Digital Processing of Continuous-Time Signals

Theory and praxis of synchronised averaging in the time domain

Corona Current Data Acquisition Card Based on USB Bus in Extra High Voltage Environment

Wavelet Transform for Classification of Voltage Sag Causes using Probabilistic Neural Network

Modelling and Simulation of PQ Disturbance Based on Matlab

CHAPTER 4 HARDWARE DEVELOPMENT OF STATCOM

Fluke Three-Phase Power Quality Recorder Topas. Class-A compliance for the most demanding power quality tests

Developer Techniques Sessions

The Fluke 6100A. Electrical Power Standard. The most accurate, comprehensive and flexible source of electrical power signals

Electrical appliances testing platform

HV / MV / LV electrical network quality analyzers Class A. Communication port: local, modem, integrated Ethernet, multi-point

THE BENEFITS OF DSP LOCK-IN AMPLIFIERS

Comparison of Lamination Iron Losses Supplied by PWM Voltages: US and European Experiences

Inter Harmonics of Cycloconveter Excited Induction Motor and Design its Filter Circuit

Selection of Mother Wavelet for Processing of Power Quality Disturbance Signals using Energy for Wavelet Packet Decomposition

CHAPTER 2 VSI FED INDUCTION MOTOR DRIVE

Improved digital phase measurement

Power Quality Improvement By Using DSTATCOM Controller

Power quality report. A Manufacturing Plant

CHAPTER 2 A SERIES PARALLEL RESONANT CONVERTER WITH OPEN LOOP CONTROL

REGENERATIVE GRID SIMULATOR MODEL SERIES MODEL SERIES PRELIMINARY. Regenerative Grid Simulator. Key Features :

[Nayak, 3(2): February, 2014] ISSN: Impact Factor: 1.852

An Introduction to Power Quality

Design Requirements for a Dynamic Series Compensator for Voltage Sags Mitigation in Low Voltage Distribution System

Smart Energy & Power Quality Solutions. Portable energy measurement devices COMPACT FLEXIBLE PRECISE

POWER QUALITY REPORT

Current based Normalized Triple Covariance as a bearings diagnostic feature in induction motor

Teaching digital control of switch mode power supplies

AN ALGORITHM TO CHARACTERISE VOLTAGE SAG WITH WAVELET TRANSFORM USING

Validation of Frequency- and Time-domain Fidelity of an Ultra-low Latency Hardware-in-the-Loop (HIL) Emulator

Transcription:

XIX IMEKO World Congress Fundamental and Applied Metrology September 6 11, 2009, Lisbon, Portugal DSP-BASED ISTRMET FOR POWER QALITY MOITORIG O SHIPS Janusz Mindykowski 1, Tomasz Tarasiuk 2 1 Gdynia Maritme niversity, Gdynia, Poland, janmind@am.gdynia.pl 2 Gdynia Maritme niversity, Gdynia, Poland, totar@am.gdynia.pl Abstract The paper is to present the new DSP-based device shown in the wake of hitherto development of power quality instrumentation for power quality assessment in ship systems. The basic features of the new power quality estimator-analyser are described. Further, the design of its new commercial version is shown and discussed. Keywords: power quality, measurement instrumentation 1. ITRODCTIO The term power quality has various meaning but usually it should be understood as supply voltage quality completed but current quality [1-2]. The proper assessment of power quality requires determining of many different parameters. Therefore, instrumentation designed for the aim is multiparameter device and utilizes numerous methods and algorithms of signal processing [2]. The most time consuming task is waveform assessment. This requires the appropriate methods and tools if on-line measurement capabilities are desired. There are quite a few methods of waveform parameters estimation but, arguably, the most popular tools is discrete Fourier transform DFT, especially its fast algorithm called fast Fourier transform FFT. nfortunately, FFT has commonly known downside. On the one hand, it requires the particular number of samples, usually power of two. On the other hand the input data set should contain integer number of cycles of all signal components in order to avoid consequences of spectrum leakage. This can be a problem if fundamental frequency of signal fluctuates. During last twenty years various techniques were developed for dealing with variations of input signal parameters. The most discussed solutions concern the interpolation in time or frequency domain [3] or synchronization of sampling frequency [4]. In some papers application of other tools for voltage waveform assessment has been proposed. First of all discrete wavelet transform DWT has to be mentioned. The tool is widely used for transient states detection and evaluation but some authors proposed its application in the form of wavelet packet decomposition WPD for harmonics assessment [6]. However, it seems that instruments based on other principles of waveform assessment lack simplicity and/or do not enable comparable frequency resolution. Therefore, the most of commercial power quality devices still utilizes FFT as the basic algorithm for harmonics and interharmonics assessment. 2. STADARDS AD ISTRMETATIO FOR POWER QALITY ASSESSMET The recommended methods of measurement of power quality parameters were defined in IEC Standard 61000-4- 30 [7] and IEC Standard 61000-4-7 [8]. The latter standard deals with problem of waveform assessment in the frequency range up to 9 khz. Especially, a following structure measurement instrument was proposed [8]: input circuits with anti-aliasing filter, with sample-and-hold unit, synchronisation and window shaping unit if necessary, DFT-processor. The recommended width of measurement window is 10 cycles for 50 Hz systems and 12 cycles for 60 Hz systems. Therefore synchronisation of sampling frequency is proposed [8]. The window shall be synchronized with integer number of input signal cycles in such a way that the time between the first sampling pulse in considered window and the first sampling pulse in the next window is to be equal to duration of previously specified number of cycles, with maximum permissible error of ±0,03% [8]. The rectangular window shall be used. Hanning window is allowed only in the case of loss of synchronisation. Further, it was assumed that normally FFT algorithm will be used [8]. The above described method of harmonics and interharmonics assessment is commonly applied in various commercial power quality analyzers, e.g. Fluke 434/435 three phase power quality analyzer [9] or PowerVisa TM power quality analyzer [10]. nfortunately, the method lacks of versatility and should not be used in some systems, especially isolated power systems like ship systems. The proper synchronisation of sampling frequency is nearly impossible and application of Hanning window can lead to dubious results in these systems. It is caused by relatively fast fluctuations of power quality parameters. The concept of harmonics and interharmonics grouping proposed in IEC Standard 61000-4-7 [8] is no solution as well. The details can be found in [11]. Therefore, discarding FFT as basic tool of power quality analysis was suggested [12] and other methods and algorithms were developed. Especially, application of DWT, DFT and chirp z-transform CZT in complementary way was proposed [13-15]. It was behind prototype of low cost, original measurement device, developed for scientific purposes in Gdynia Maritime

niversity. This new solution is shortly described in the Section 3. However, the main aim of the current paper is to describe and shortly discuss reasons for the estimatoranalyser development as well as proposed hardware structure of the expanded version. This will be described in Section 4. 3. THE PROTOTYPE OF ESTIMATOR-AALYSER OF POWER QALITY The prototype of the new device for power quality assessment called estimator-analyser was developed in Gdynia Maritime niversity in co-operation with Institute of Power Engineering, Gdansk Division. The most important feature of the unit is its ability to correct operation under condition of great changeability of input signal parameters and it does not require synchronisation of sampling frequency. The estimator-analyser is two-processor device, including digital signal processor ADSP 21364, and it is capable of working in stand alone condition or in cooperation with external device, e.g. PC computer. The instrument can operate in two basic modes: estimator and analyser. In the former mode only parameters which current values exceed user defined limits are determined, whereas in the latter mode all defined parameters are calculated. In the estimator mode less computational power is required, so it enables increase in sampling frequency (currently sampling frequency equal to 148917.8 Hz is utilized). The feature was achieved due to implementation of original distortion band factors DBF for rough waveform assessment in the estimator mode [14]. Finally, estimator-analyser is capable of determining the following voltage quality parameters [12]: r.m.s. value, frequency, unbalance, newly introduced distortion band factors DBF, voltage dip estimation (value and duration), harmonic subgroups measurement up to 50 th harmonic, interharmonic centered subgroups measurement in the range up to 50 th harmonic, sub-harmonic, dc component, groups of high frequency components with bandwidths approximately 200 Hz in the range from 50 th harmonic up to 9 khz, transient and notching detection and assessment, power quality temperature factor for assessment of additional temperature rise of windings of induction motors [16]. The picture of the estimator-analyser is shown in Fig. 1 [12]. Fig. 1. Front panel of the estimator-analyzer of power quality. The prototype of estimator-analyser uses several screen types in order to present various measurement results in both operation modes as well as setting of basic parameters of the device. The exemplary photograph of the device display is shown in Fig. 2. Fig. 2. An example of screen of estimator-analyser prototype; analyser mode and display of harmonic and interharmonic subgroups up to 4 th harmonic. The estimator-analyser was tested under laboratory conditions for several various testing signals as well as in ship environment [17]. The positive results of the experimental verification were premises for manufacturing of the second piece of estimator-analyser. The total cost of the manufacturing did not exceed 2000 ER, including taxation. The details of methods and algorithm applied in the prototype of this new device for power quality assessment will be published in separate papers together with results of its experimental verification. This paper is focused on the planned device further development and motivation for the undertaken work. 4. DESIG OF THE EXPADED VERSIO OF ESTIMATOR-AALYSER OF POWER QALITY The complete assessment of power quality in ship systems requires an estimation of more parameters than current estimator-analyser is capable of. Therefore, new version of the estimator-analyser was designed and it is now under construction. First of all, it is capable of current and power parameters monitoring. Especially, the later should be underlined since system for power quality estimation on ships is to control power distribution between generating sets working in parallel. The improper power and current

distribution increases a risk of overloading of generating set (generator and prime mover) and, as consequence, increases a risk of black-out in whole ship s system. The consequences are easy to predict. The purposes of power quality assessment in ship s system are to be taken into account as well. Basically there are two aims of the monitoring of power quality in these systems: evaluation of conformity with respective standards and trouble-shooting applications. The first task is carried out mainly by surveyors of ship classification societies, whereas the second one is carried out by ship s crew. The surveys carried out by ship classification societies are carried out during ship classing and portable devices would be appreciated. The monitoring carried out by ship crew is carried out on continuous everyday basis and device built in main switchboard can be used. Further, the device structure and applied algorithms should be as versatile as possible in order to increase scope of possible applications. Simply put, designing a device dedicated only to ship s application would be economically unjustified. Therefore, the software and hardware of the expanded version of estimator-analyser should enable its application in various power systems, isolated or not. First of all, the estimator-analyser is to monitor power quality in three-phases three-wires and four-wires networks. Moreover, it should be capable of measurement currents as well as active and reactive powers in these both networks. But in the case of ship systems the load distribution between generating sets working in parallel. It was assumed that at least three generating sets are to be monitored concurrently. Taking into account the above described reasons and minimal requirements as well as the results of the prototype investigation, the structure of the expanded version of estimator-analyser was determined. The simplified hardware structure of the new instrument is depicted in Fig. 3. The signal conditioning unit will consist of programmable antialiasing filters LTC1564. The cut-off frequency of the former estimator analyser was 60 khz but it will be significantly increased, due to increase in sampling frequency in the new version. The increase of considered frequency band is planned up to 100 khz (planned sampling frequency 250 ks/s). As a result, an enhancement of transient monitoring capabilities will be achieved. It should be added that the sampling frequency is sufficient for determining parameters of quite a number of transients and notching observed in real ship power systems [18]. In the case of voltage channels a voltage divider and isolation amplifiers AD215 will be used. The estimatoranalyser will be supplied with six external current probes. The expanded version of estimator-analyser will be twoprocessor device. Such a solution was positively tested in above mentioned prototype of estimator-analyser. DSP is to carry out all signal processing tasks and control of ADC s, whereas GPP is to control remaining peripherals and communicate with external devices. Due to such a solution the resources of DSP are reserved for the most time-consuming procedures of signal processing, without unnecessary interruptions (user or external devices). Therefore, it is easy to design software for real-time gapless power quality monitoring. But it should be mentioned that more powerful processors (especially DSP) will be used. bus bars of main switchboard L 1 L 2 L 3 I G11 I G13 I G21 I G23 I G31 I G33 Signal conditioning unit Signal conditioning unit SB Ethernet Estimator-analyser of power quality AD7656 AD7656 RAM Flash memory keyboard DSP TigerSHARC GPP LCD display Fig. 3. Simplified hardware structure of the new version of estimator-analyser of power quality; DSP digital signal processor, GPP general purpose processor. The depicted in Fig. 3 hardware configuration enables an evaluation of power distribution between three generating sets working in parallel in three-phase and three-wire systems. It should be mentioned that it is typical configuration of ship networks. The exemplary connection of one generating set with instrument under construction is shown in Fig. 4. The calculation of active power can be carried out by following formula [19]: P = 1 ( u12k i1k + u32k i3k ) (1) The reactive power can be calculated on the basis of the very same algorithm (it means that the same sun-routine can be used) but it requires shifting starting address of voltage samples by T/4, where T is a period of input signal. In fact it means shifting the voltage signal by 90 o. The solution can lead to flawed results in the case of distorted signals [20]. Fortunately, it seems that in the case of ship systems chiefly reactive power of fundamental components is to be considered (diagnostics of voltage controller operation). Therefore, the simple solution is taking into account only fundamental component of currents. It requires low-pass

filtration. Finally, the reactive power of fundamental components can be calculated as follow: Q 1 1 = ( u12k T / 4 ifund1k + u32k T / 4 ifund3k ) (2) The proposed solution simplifies hardware structure and software for active and reactive power calculation as much as possible. G 3 I I DSP Fig. 4. The scheme for determining the power parameters for one generating set in the three-phase and three-wire system. 5. FIAL REMARKS owadays used analysers for power quality assessment display some disadvantages in relation to application in isolated electrical power networks. It concerns used methods of measurement of power quality parameters as well as their hardware. Typically, these analysers are equipped with four current input channels. It is insufficient for assessment of power distribution in ship systems. Their hardware structure enables a calculation of respective parameters only for two generating sets working in parallel, whereas in many cases three generators are connected together in ship systems. Obviously, the software of commercial analysers is inappropriate as well. Finally, the new solution for power quality assessment in ship systems was proposed. Comparing with current solutions, it utilizes the new methods of waveform assessment and it has increased number of current input channels. Due to the latter feature, the device will be capable of determining active and reactive power distribution between up to three generating sets working in parallel. Although it was designed for marine applications, the applied methods and algorithms can be utilized for other systems as well. Simply put, the ship power system can be treated as the hardest case from power quality assessment point of view. The additional input for neutral line will be provided in order to increase instrument versatility. L 1 L 2 L 3 Obviously, device s software has to be designed accordingly. Finally, the device will be capable of power quality assessment in one-phase two-wire systems, three-phase treewire systems and three-phase four-wire systems. ACKOWLEDGMETS This work was financially supported by the Ministry of Sciences and Higher Education, in Poland, in years 2007-2010 (Project o. R01 027 03). REFERECES [1] M. Bollen, What is power quality?, Electric Power Systems Research, no. 66, pp. 5-14, 2003. [2] A. Ferrero, Measuring electric power quality: Problems and perspectives, Measurement, vol. 41, no 2, pp. 121-129, 2008. [3] M. Sedláček, M. Titěra, Interpolations in frequency and time domains used in FFT spectrum analysis, Measurement, vol. 23, no. 3, 1998, pp. 185-193. [4] M. Aiello, A. Cataliotti, V. Cosentino, S. uccio, Synchronization techniques for power quality instruments, IEEE Transactions on Instrumentation and Measurement, vol. 56, no 5, pp. 1511-1519, 2007. [5] S. Santoso, W. Grady, E. Powers, J. Lamoree, S. Bhatt Characterization of distribution power quality events with Fourier and wavelet transforms, IEEE Transactions on Power Delivery, vol. 15, no 1, pp. 247-254, January 2000. [6] L. Eren L., M. nal, M. Devaney, Harmonic analysis via Wavelet Packet Decomposition using special elliptic half-band filters, IEEE Transactions on Instrumentation and Measurement, vol. 56, no 6, pp. 2289-2293, 2007. [7] IEC Std. 61000-4-30, 2003. Testing and Measurement Techniques Power Quality Measurement Methods. [8] IEC Std. 61000-4-7, 2002. General guide on harmonics and interharmonics measurements for power supply systems and equipment connected thereto. [9] Fluke 43B power quality analyzer. sers manual. Fluke Corporation, 2005. [10] PowerVisa TM. ser s guide. Dranetz-BMI 2005. [11] T. Tarasiuk, Comparative study of various methods of DFT calculation in the wake of IEC Standard 61000-4- 7, IEEE Transactions on Instrumentation and Measurement, in press. [12] T. Tarasiuk, A few remarks about assessment methods of electric power quality on ships present state and further development, Measurement, doi:10.1016/j.measurement.2008.02.003, in press, available on-line: www.sciencedirect.com.

[13] T. Tarasiuk, Hybrid wavelet-fourier spectrum analysis, IEEE Transactions on Power Delivery, vol. 19, o 3, pp. 957-964, July 2004. [14] T. Tarasiuk, The method based on original DBFs for fast estimation of waveform distortions in ship systems Case Study, IEEE Transactions on Instrumentation and Measurement, Vol. 57, no 5, pp. 1041-1050, May 2008. [15] T. Tarasiuk, Application of CZT transform for spectrum analysis in systems with varying frequency. IEEE 4 th IDAACS 2007, pp. 329-334, 6-8 September 2007, Dortmund, Germany. [16] P. Gnaciński, J. Mindykowski, T. Tarasiuk, A ew Concept of the Power Quality Temperature Factor and Its Experimental Verification, IEEE Transactions on Instrumentation and Measurement, vol 57, no 8, pp. 1651-1660, August 2008. [17] T. Tarasiuk, M. Tarasiuk, M. Szweda, Elaboration of the new method and measurement instrumentation for fast estimation of power quality (Opracowanie nowej metody i instrumentarium pomiarowego do szybkiej oceny jakości energii elektrycznej), Final Rep. Grant 3T10C02027 for Polish Ministry of Sciences and Higher Education, Gdynia 2007 (in Polish). [18] Szweda M., Tarasiuk T.: Frequency characteristic of transients and notching disturbances case study. 16 th IMEKO TC4 Symposium, Sept. 22-24, 2008, Florence, Italy, s. 272-277. [19] M. ovotny, M. Sedlacek, Measurement of active power by time domain digital signal processing, Measurement, 2008, doi:10.1016/j.measurement.2008.02.002, in press, available on-line: www.sciencedirect.com. [20] P. Filipski, P. Labaj, Evaluation of reactive power meters in the presence of high harmonic distortion, IEEE Transactions on Power Delivery, Vol. 7, o. 4, pp. 1793-1799, December 1992.