JorVet. Hand-Held Doppler. Operating Manual. Jorgensen Laboratories, Inc. Loveland, Colorado 80538

Similar documents
OPERATING MANUAL MINIDOP ES-100VX POCKET DOPPLER

: 0089 GTIN

J-470 ELECTROSURGE. Radio Frequency Electrosurgery Unit. Operation Instructions

GTIN:

servicing. Products will be repaired or replaced in a reasonable amount of time, to be determined by service personnel.

User Manual. Newman Medical

Headset Intercom System. Operating Instructions

MD9300 Metal Detector OWNER S MANUAL

Cleaning the cutter blade

Single Channel Radio Mic System USER MANUAL. WMU-116-H (Hand Held) WMU-116-B (Belt Pack) Single Channel Radio Mic System

DOPPLEX VASCULAR DOPPLERS. ...with people in mind

RU210. Dual Multi-UHF Wireless System. Item ref: UK, UK User Manual. Version 1.0

DX-395. FM/AM/SW1/SW2 PLL Synthesized Receiver OWNER S MANUAL. Cat. No Please read before using this equipment.

3-band Portable Radio ROBERTS. Sound for Generations. Please read this manual before use

High Intensity LED Stroboscope Digital Tachometer DT-361/365. Instruction manual. Be sure to read before use.

*Notebook is excluded

Lab: Blood Pressure. Goal: Design and test a bandpass filter that can isolate a blood pressure signal.

TRI-STAR PREAMP & TRI-STAR PRO PREAMP

ReSound Micro and Multi Mic

RING CUTTING SYSTEM OPERATION MANUAL. The lighter your touch, the faster GEM cuts

Golden Mask Deep Hunter LE

1. Blood pressure (BP) module and accessories

User Manual for LifeDop L350R Series (Tabletop Doppler)

ULTRASOUND DETECTOR D240x OPERATING INSTRUCTIONS. Pettersson. Phone: Fax:

18 Indoor/Outdoor Atomic Wall Clock

Controls. LCD display A B C D E F

MFJ-219/219N 440 MHz UHF SWR Analyzer TABLE OF CONTENTS

See Page 8 for Part Numbers

D C 01/2019 3

AM48 XT & AM48e XT Family of Products

Operator s Manual DLS-1. Diver s Locator Sonar Hand-Held Sonar Set. Ultra Electronics Ocean Systems 115 Bay State Drive Braintree, MA 02184

Congratulations! Quick start. Legend

IMPORTANT SAFETY INSTRUCTIONS:

H201 中文 GB Version 1

TWO-WAY RADIO MODEL CXR925

LDG TW-1 Talking Wattmeter

DIY KIT DIY KIT. User Manual CTK

SAFETY INFORMATION IMPORTANT FCC LICENSING INFORMATION

19'' Rack Mount 300 Watt Power Amplifier/ Mixer w/70v Output & Mic Talkover USER MANUAL

Transcutaneous Electrical Nerve Stimulator TENS 212. Instruction Manual. Read before using

MFJ-203 Bandswitched Dip Meter

rainbow ReSposable Pulse CO-Oximeter Sensor System Training Please see product s Directions for Use for more information 2012 Masimo Corporation

EHRLUND MICROPHONES EAP MANUAL. for. Ehrlund Acoustic Pickup Ehrlund Preamp Portable Ehrlund Preamp Phantom

PLA-240. Small Room Loop Amplifier System. USER Manual MAN 211A

Far End Device II Model 1342

Handheld Omnidirectional Laser Scanner

USER'S MANUAL DMR-6700

Fetal and Vascular Dopplers. User Manual for TR150 Series Units (Non-Display) and TR250 Series Units (Display)

Important safety instructions

Vevo770 Ultrasound. Quick Operation Guide

COJSAWBX Electric Jig Saw Assembly & Operating Instructions

Sonic Distance Sensors

(6) Changing the brightness of the illumination. 16 (7) Additional features Power saving mode Checking the battery status...

Instruction Manual PMR-101TX. Private Mobile Radio. TTI Tech. 446MHz, 8 Channels

DSTS-3B DEPTHSOUNDER TEST SET OPERATOR S MANUAL

Star Trac Group Cycling Computer Owner s Manual and Installation Guide

900 MHz Digital Wireless Indoor/Outdoor Speakers

WIRELESS STEREO WOODEN PANEL SPEAKER SYSTEM

Instructions to Convert a 4-foot Florescent Fixture to LEDs Using 60W Power Supply Using 2 or 3 strips 30Dec15

Chapter 4. Pulse Echo Imaging. where: d = distance v = velocity t = time

1. Initial Precautions 2. Technical Precautions and Suggestions 3. General Information and Cure Stages 4. Understanding and Controlling Cure Time

Centurion Laser Shower

ME6000 Sensor guide for MegaWin

Read Me First! PICKUP INSTALLATION MATRIX INFINITY VT MATRIX INFINITY MIC BLEND INSTALLATION GUIDE. *Minimum 20⁰ string break angle

Weatheradio Alert ( ) Features Faxback Doc. # 47648

RING CUTTING SYSTEM OPERATION MANUAL

Stride / Stride Dual

5. Carefully remove the printer from the lower boxed foam support and place it on a solid, level base where it will be used

Instructions to Convert a 4-foot Florescent Fixture to LEDs Using a SS 25W Power Supply and a 4 LED strip 30Dec15

Exercise 2: Distance Measurement

Ai1 OWNER S MANUAL. Getting Started:

Preface. This manual is applicable to the following product: PD70X/70XG Digital Portable Radio (X may represent 2, 5, 6 or 8)

Ultrasonic Diagnostic Tool. Users Manual. Read this manual thoroughly before use

User Manual and Installation Instructions

Read Me First! PICKUP INSTALLATION MATRIX INFINITY VT MATRIX INFINITY MIC BLEND INSTALLATION GUIDE. *Minimum 20⁰ string break angle

UHF WIRELESS MICROPHONE WM-5320A WM-5320H

SP980. Cordless Stereo 863MHZ. Speaker System. User s Manual INTRODUCTION FEATURES. Please read before using the equipment

OWNER S MANUAL. SimmonsDrums.net

Ultra / Ultra Dual. Waterproof & Rechargeable Dog Training Collar. Note: Picture shown is Ultra Dual

User Manual. Digital Compound Binocular LED Microscope. MicroscopeNet.com

TW Operating Manual F I S H E R R E S E A R C H L A B O R A T O R Y. Digital Line Tracer

DIAGNOSTIC SCANNER HS-1600V. Convex/Linear Ultrasonic System

Instructions to Convert a 4-foot Florescent Fixture to LEDs Using 100W Power Supply Using 1-4 strips 30Dec15

Sound n Lights Monitor

Microflow-S User s Documentation

Central Blood Pressure Meter Model cbp301. Operating Manual

DE1103 PLL FM STEREO/SW.MW.LW DUAL CONVERSION SYNTHESIZED WORLD RECEIVER OPERATION MANUAL

Mirrorcraft Project Especially for Dogs

Aeon CLR Series EDGE FREE CLR Fixed Frame Screen w/ StarBright CLR (Ceiling Light Rejecting ) Front Projection Material

On-Line Cardio Theater Wireless Digital Transmitter Installation and Instruction Manual

METAL DETECTOR INSTRUCTION GUIDE

INSTRUCTION MANUAL. 200 Main Street Elmwood WI Phone: Toll Free: Fax:

Treasure Cove Metal Detector

Building the Sawdust Regenerative Receiver

iphone 4S Dismantling Instructions

Table of Contents. Wall Mount Installation Page 2 Double Mount Installation Page 3. Wiring Information... Page 4. Operational Instructions Pages 5-8

INTRODUCTION. 4 SAFETY INSTRUCTIONS. 5 ABOUT THIS DEVICE. 6 FIRST OPERATION. 7 THE DISPLAY. 8 ATTACHING THE WRIST SLEEVE. 9 CORRECT MEASUREMENT.

ModelSG-789L 10 BANDS HANDY RADIO. Operating Instructions Mode 'Demploi ~Bed;enungsanle;tung

Bio-Tuner Model BT7. A Consumer Product

Model 526T Series II Super Punch Microphone User Guide

Transcription:

JorVet Hand-Held Doppler Operating Manual Jorgensen Laboratories, Inc. Loveland, Colorado 80538

Thank You! for choosing the JorVet Hand-Held Doppler! This choice acknowledges the many advantages of the JorVet Hand-Held Doppler: Small, Hand-Held Size Great Sensitivity Convenient Probe Activation Button (turns Doppler On and Off) Automatic Power Off Two Cuff Sizes: 2.5 cm and 5 cm Index of Pages: Parts of Your MiniDop........................ 2 Operating Instructions........................ 4 Directions for Use........................... 6 Cleaning Instructions......................... 8 Warranty.................................. 8 Cautions.................................. 9 Package Contents............................ 10 Specifications............................... 11 Principles of Doppler Flow..................... 12

Parts of Your Minidop FRONT 4 5 3 2 1 1. Probe Connector: To connect probe. 2. Headset: To connect headset. (not included) 3. Volume Control: To adjust volume control. 4. Power Indicator: Indicates power On/Off. 5. Speaker: Outputs Doppler sounds. 2

BACK 8 7 6 PROBE 9 6. Probe Holder: For probe placement when not in use. 7. Strap Holes: To connect strap. 8. Battery Cover: For battery replacement. 9. Probe Button: To turn unit On/Off. 3

Operating Instructions 1. Open the battery cover as pictured on the left. Set a 9 volt alkaline square type battery in the unit ensuring that the positive and negative electrodes correspond to the + and marks on the label in the battery box. + - 2. Connect the probe with the small dot up on the probe connector (12 o clock), and depress the probe button to turn the unit ON. Power Indicator Volume Control 3. Make sure the power indicator on the unit is on. Turn the volume control to minimum, then slowly turn the volume up. 4

4. Put the ultrasonic gel on the probe top or the patient s skin. 5. Put the probe on the measurement area and move it slowly to locate the point where maximum Doppler sounds are heard. The flat probe should be 90 degrees placed flat on the animal s skin over vessel. 6. Connect the headset when necessary. Headset can be used to listen to Doppler sounds. It will cut off the speaker to the room. 7. Depress the probe button again to turn the unit OFF. If the unit is left on, the power automatically shuts off in about 5 minutes. Note: The auto-off time depends on room temperature. 8. Replace the battery with a new one if the power indicator becomes dark. Use a 9 volt ALKALINE square type battery. A non-alkaline battery may cause a short. 5

Directions for Use Indirect Arterial Blood Pressure Monitoring With the Doppler Unit 1. Clip the palmer aspect of the foot just proximal to the metacarpal pad. It is important to clip the fur as short as possible. Rub a small amount of ultrasound gel into the skin in the midline area where the palmer arterial arch is located. It can be palpated on large dogs and is actually just slightly medial to the midline. 2. Place a large globe of ultrasound gel on the non-numbered side of the Doppler flow probe. Place the probe in the location of the artery described in step one and tape it in place tightly. (Turn on the Doppler unit with the flow probe plugged into the unit. The flow probe should not be frequently disconnected from the unit as this loosens the connectors and wires in the unit). 3. Ensure that the unit is charged. A swishing sound should be heard each time the blood flows through the artery. If it is not heard use the probe as a locator and move slightly until the swishing sound is heard and then re-tape in place. 4. Make a loop in the cord of the flow probe and tape the cord to the foot/metacarpal loop is right over the tape used to fixate the flow probe to the skin initially (as described in step two). 5. The blood pressure cuff is now placed. The cuff s width should approximate the width and be up to two times that of the forearm (mid-radial region). It is applied so that the mid-section on the rubber blade inside the cuff is directly over the posterior medial aspect (where the radial artery is located). This can be located by digitally occluding the area and hearing the swishing sounds of the Doppler stop indicating the artery is at that location because its flow is now temporarily blocked. 6. When the cuff is applied the INDEX line on the end of the cuff should fall within the RANGE on the cuff, which is diagrammed on the inside. If outside this range the reading will be either falsely low (with cuffs too big for the size of the limb it is surrounding), 6

or falsely high (with the cuff too small). An estimate can be arrived at that will indicate how far off, in percentage, the cuff reading will be, taken by observing the amount of length the cuff is too small or too large compared to the entire length of the indexed area. 7. A small amount of adhesive tape is added around the cuff to prevent it from popping the Velcro and showing a falsely high reading. 8. The cuff is inflated by squeezing the rubber bulb with the airoutlet nozzle closed until the manometer reading is 20-30 mm Hg above when the swishing sound stopped. The air-outlet nozzle is slowly opened and the cuff is allowed to slowly deflate. When the swishing sound is first heard again this marks the flow of blood through the artery corresponding to SYSTOLIC PRESSURE on the sphygmomanometer. The sound should be a shorter choppier sound than was heard when the cuff was not inflated. 9. The cuff deflation is continued slowly as the characteristics of the swishing sound are carefully monitored. A light backward sound or diastolic swish sound is again heard (or as it is again sounded prior to any cuff inflation) corresponding to DIASTOLIC PRESSURE when a very mild amount of backflow in the artery occurs. The diastolic pressure is not always evident. 10. Diastolic pressure can be detected by closely watching the dial of the manometer. If it oscillates reproducibly at certain times on the deflation cycle, this corresponds to within 10mm Hg of the diastolic pressure (by sound). For accuracy, when the diastolic sound cannot be heard, pressure is simple recorded as systolic all the way down. This is especially frequent during periods of high stress when the vessels are under significant catecholamine influence and are acting stiff, or in very small or cold patients where the vessels are simple to small to allow sound change detection. Normal systolic values of dogs and cats range from 110-160mm Hg. 7

Cleaning Instructions 1. Probe Remove the Doppler gel from the probe head after use. Clean or disinfect the probe using a cotton ball soaked in alcohol. Consult manufacturer before using any other chemical disinfectants. 2. Main Unit To clean main unit, use a little water and wipe with a soft dry cloth. Warranty This equipment is guaranteed for a period of one year after the date of purchase when used under normal conditions. In the event of any trouble during the warranty period, please contact the dealer from whom you purchased the unit. In case the warranty period is over, please contact the dealer for a charged service THE WARRANTY CARD MUST BE RETURNED WITHIN TWO WEEKS OF PURCHASE! 8

Cautions Probe The standard probe is for transcutaneous use only. The probe transducer is a very thin and delicate part. Please take care not to drop or hit the probe tip. The probe cover also prevents against switching On when storing unit after use. Ultrasound Gel Always use an ultrasound gel. Using other materials such as baby oil or cream may not produce the correct Doppler sounds and may damage the probe. Battery When battery is low, the power indicator becomes dark. Also there will be no speaker sounds. Replace the battery if these conditions exist. Use a 9 volt alkaline square type battery. A non-alkaline battery may cause a shortage of power. 9

Package Contents The JorVet Hand-Held Doppler package includes the following items: Flat probe (includes probe tip holder).......... J-563D1 Mini Doppler Detector Unit................ J-563D2 Sphygmomanometer for Mini Doppler........ J-563D3 2.5 cm Cuff............................. J-563D4 5.0 cm Cuff............................. J-563D5 Headset for Doppler....................... J-563D8 Hadeco Carrying Case 9 volt Alkaline Battery Adjustable Strap Ultrasonic Gel Operating Manual Use of the Doppler for the Feline Patient Booklet Warranty Card 10

Specifications Probe: Model: Freq.: J-563D1 Flat probe 8 mhz Battery: Battery Life: Auto Shut-Off: Probe Button: Speaker Output: DC 9 volts, Alkaline square type Approximately 3 hours (Alkaline) Automatic after approximately 5 minutes of inactivity. Varies with room temperature. Power On/Off 200 mw or more External Outputs: -Headset Cuts off speaker (3.5mm jack) Dimensions: Main Unit: 75mm(w) x 140mm(d) x 25mm(h) Weight: Probe: 20mm (diam.) x 105mm (L) Approximately 270 grams (includes battery and probe) 11

Principles of Doppler Flow The JorVet Doppler is designed to receive blood flow velocity information by ultrasound. A specific frequency is transmitted from the probe to the patient. Technically the transceiver amplifies a high frequency oscillation output for transmission to the transducer. The voltage is converted by a piezoelectric crystal (transducer) to ultrasound. The ultrasound beam is transmitted to blood cells flowing through the arteries or to beating fetal hearts. The ultrasound beam is reflected by the red blood cells or by moving structures, and received by the crystal in the transducer which converts the ultrasound into a voltage. A Doppler shift occurs between the emission and reception of the ultrasound beam. Advantages of using Doppler flow detectors include ease of application, portability, applicability to hypotensive animals, and usefulness as an audible monitor of the arterial pulse and peripheral blood flow. 12

Jorgensen Laboratories, Inc. Loveland, Colorado 80538 1450 N. Van Buren Avenue Loveland, Colorado 80538 1-800-525-5614