R&S EM510 HF Digital Wideband Receiver Efficient and versatile solution for radiomonitoring

Similar documents
R&S EB500 Monitoring Receiver Specifications

R&S MNT100 RF Interference Locator Specifications

Monitoring Receiver R&S ESMB

R&S RSC Step Attenuator Specifications

R&S FSC Spectrum Analyzer Specifications

R&S FU129 Antenna Filter Unit Antenna switching, rotator control and signal attenuation, amplification and filtering

R&S ZN-Z5x Calibration Units Specifications. Data Sheet V03.00

R&S ZVT Vector Network Analyzer Specifications

R&S ESCI/ESCI7 EMI Test Receiver Specifications

R&S ZV-Z5x Calibration Units Specifications

R&S ZN-Zxxx Calibration Units Specifications. Data Sheet V04.00

Analog Modulation Analysis (AM/FM/φM) Specifications

EB200 Miniport Receiver

R&S ZNBT8 Vector Network Analyzer Specifications

R&S UMS175 Compact Radiomonitoring System High performance for outdoor deployment

R&S ZNC Vector Network Analyzer Specifications

R&S ZNB Vector Network Analyzer Specifications

Spectrum Analyzer FSL

Attenuators and Matching Pads, Terminations 75 mw to 1000 W, DC to 18 GHz

R&S EB500 Monitoring Receiver High-performance radiomonitoring from 9 khz to 6 GHz

R&S ZVT Vector Network Analyzer Specifications

R&S FSH4/8 Spectrum Analyzer Specifications

R&S ZV-Z5x Calibration Units Specifications

Product Brochure Version R&S EB510 HF Monitoring Receiver High-performance radiomonitoring from 8 khz to 32 MHz

R&S FPC Spectrum Analyzer Specifications

R&S SMC100A Signal Generator Specifications

R&S CLGD DOCSIS Cable Load Generator Multichannel signal generator for DOCSIS 3.1 downstream and upstream

R&S FS-K112PC NFC Measurement Software Specifications

R&S CBT/R&S CBT32 Bluetooth Tester Specifications

Noise Figure Measurement Applications Specifications

Radiomonitoring & Radiolocation Product Brochure R&S EM100 Digital Compact Receiver Compact radiomonitoring from 9 khz to 7.

R&S TS8997 Regulatory Test System for Wireless Devices

R&S MNT100 RF Interference Locator

Vector Network Analyzers ZVB

R&S ZVA-Zxx Millimeter-Wave Converters Network analysis up to 500 GHz

R&S ZV-Z3xx T-Checker Specifications

R&S EB500 Monitoring Receiver High-performance radiomonitoring from 9 khz to 6 GHz

R&S NRPM Over-the-Air (OTA) Power Measurement Solution For 5G, WLAN IEEE ad and IEEE ay

R&S ZV-Z135 Calibration Kit Specifications

Signal Generator SMA 100A

R&S EM100 Digital Compact Receiver Compact radiomonitoring from 9 khz to 7.5 GHz


Receiver requirements for a TDOA-based radiolocation system

R&S ESRP EMI Test Receiver Specifications

R&S ENV216 Two-Line V-Network For disturbance voltage measurements on single-phase EUTs

ESU EMI Test Receiver

Evolution of the Modern Receiver in a Crowded Spectrum Environment White Paper

R&S FSV Signal and Spectrum Analyzer Specifications

R&S ZVL Vector Network Analyzer Specifications

R&S FSV Signal Analyzer Specifications

LabWindows/CVI, VXIpnp driver history for the R&S Radio Tester

RF Signal Generator SM300

Signal Generator SML

Bring satellites into your lab: GNSS simulators from the T&M expert.

Guide Version Five techniques for fast, accurate power integrity measurements

Spectrum Analyzer R&S FS300

Measurement Setup for Phase Noise Test at Frequencies above 50 GHz Application Note

: Triple PLL, lowest reference frequency 10 khz. : ± 5 khz in 10 Hz steps, synthesized.

R&S TS-EMF EMF Measurement System Easy, frequency-selective measurement of EMF emissions

R&S CMU-Z10/-Z11 Antenna Coupler/ RF Shielding Cover Simple interference-free testing of all mobiles

Modulation Analyzer FMAB

R&S FSWP Phase Noise Analyzer Specifications

R&S DF-ATC-S ATC DF System Solution Accurate and reliable direction finding for civil and military air traffic control

R&S FSWP Phase Noise Analyzer Specifications

Keysight Technologies N9320B RF Spectrum Analyzer

HF Transmit/Receive Broadband System XB 2900

R&S SMB100N SIGNAL GENERATOR

Agilent N9320B RF Spectrum Analyzer

R&S FSx-K91/-K91n, R&S FSW/FSQ-K91ac WLAN Application Firmware WLAN TX measurements with Rohde & Schwarz analyzers

Spectrum Analyzer FSU

R&S ESR EMI Test Receiver Specifications

2026Q CDMA/GSM Interferer MultiSource Generator

Voltage Sensors URV5-Z

Modulation Accuracy Measurements of DVB-S2 and DVB-S2X Signals Application Note

Spectrum Analyzer FSU

Bring satellites into your lab

R&S ZNA Vector Network Analyzer Specifications

R&S ESRP EMI Test Receiver Specifications

Provided by R&S FSH4/FSH8 Spectrum Analyzer Specifications

R&S NRT Power Reflection Meter Family R&S NRT2 and R&S NRT-Zxx

Measuring Receiver FSMR

R&S PR100 Portable Receiver On-site radiomonitoring from 9 khz to 7.5 GHz

Signal Generator SMA100A

HZ530 Near-Field Probe Set

R&S ZVH Cable and Antenna Analyzer Specifications

Product Brochure Version R&S DDF5GTS High-Speed Scanning Direction Finder Fast, accurate direction finding

R&S FSUP Signal Source Analyzer Specifications

Handheld Spectrum Analyzer R&S FSH khz to 3 GHz

Spectrum Analyzer R&S FSP

EMI Test Receivers ESIB

Noise Figure Measurement in the 60 GHz Range Application Note

SIGNAL GENERATORS. MG3633A 10 khz to 2700 MHz SYNTHESIZED SIGNAL GENERATOR GPIB

R&S DDF1555 Compact Direction Finder Accurate direction finder for outdoor use

R&S SMB100A RF and Microwave Signal Generator Versatile, compact, up to 40 GHz; 170 GHz with upconverter

Audio Analyzer R&S UPV. Preliminary Specifications

Application Firmware for Phase Noise Measurements FS-K40

IZT R3000 Family Wideband Monitoring Receiver IZT R3000 IZT R3200 IZT R3301

FFT 3010 EMI TEST RECEIVER

Agilent N9320B RF Spectrum Analyzer

Audio Analyzers UP 300/UP 350

Transcription:

EM510_bro_en_5213-7731-32_v0200.indd 1 Product Brochure 02.00 Radiomonitoring & Radiolocation R&S EM510 HF Digital Wideband Receiver Efficient and versatile solution for radiomonitoring 27.05.2015 16:01:58

R&S EM510 HF Digital Wideband Receiver At a glance The EM510 is a fully digitized HF receiver and covers the frequency range from 9 khz to 32 MHz. Excellent RF characteristics and a wide dynamic range combined with powerful digital signal processing are the basis for optimal system solutions. The R&S EM510 HF digital wideband receiver is ideally suited for signal scans, spectrum monitoring in line with ITU recommendations. The EM510 is optimally prepared to meet future requirements in signal reception and analysis technology. It is software-compatible with the EB200/ESMB/EM550 instrument family and can thus be easily used to upgrade existing radiomonitoring systems. Key facts Wideband operation I/Q data up to 10 MHz bandwidth Demodulation up to 10 MHz bandwidth 30 IF filters (bandwidths from 100 Hz to 10 MHz) Panorama scan up to 34 GHz/s or 600 000 channels/s Frequency/memory scan up to 1500 channels/s IF panorama with up to 9.6 MHz span Video panorama, AM, FM Audio filters: notch, noise suppres sion, bandpass Dual-channel analog video output (AM, FM) ITU measurements LAN interface (SCPI) 2 EM510_bro_en_5213-7731-32_v0200.indd 2 27.05.2015 16:01:59

Description Operation The EM510 is a modern direct receiver. After the antenna signal has passed through preselection with highpass/lowpass filters, it is fed directly into the A/D converter. This concept offers a variety of advantages: Extremely high scan speed No image or IF frequencies (no mixers or local oscillators) No local oscillator phase noise Excellently suited for wideband applications No interference signals from local oscillators or mixers High linearity and simultaneously low power consumption High MTBF due to low number of critical components The receiver is controlled via the LAN interface (TCP/IP) on the basis of SCPI syntax and operates in the following modes: Fixed frequency mode (FFM) Memory scan (MScan) Frequency scan (FScan) Panorama scan (PScan) (option) Test The EM510 covers the frequency range from 9 khz to 32 MHz. A large number of IF bandwidths are available for processing the different signals with optimum signal-tonoise ratio. The use of cutting-edge digital signal processing ensures superlative results. The receiver features digital IF filters with 30 different bandwidths from 100 Hz to 10 MHz. The filter characteristics are optimized for radiomonitoring tasks, allowing topquality processing of signals up to 10 MHz bandwidth. Data can be output in the following formats: Baseband signal (I and Q) in digital form via LAN (bandwidth = 1 MHz) max FPDP (bandwidth = 10 MHz) max Video analog, DC up to ½ bandwidth, two channels (AM/FM or I/Q), or IF analog, gain control, variable center frequency 0 Hz to 21.4 MHz, two channels Video digital via LAN, two channels, AM/FM (bandwidthmax = 250 khz) or I/Q (bandwidthmax = 500 khz) AES3 for recording audio data Audio digital via LAN Audio analog (600 Ω line and headphones) Rohde & Schwarz R&S EM510 HF Digital Wideband Receiver 3 EM510_bro_en_5213-7731-32_v0200.indd 3 27.05.2015 16:01:59

Operating modes In fixed frequency mode, the receiver is set to a fixed frequency at which the signal is received, filtered and demodulated. The following parameters and functions can be selected: Frequency: setting range from 9 khz to 32 MHz with 1 Hz resolution Demodulation modes: FM AM Pulse (AM Pulse) φm USB LSB ISB CW I/Q Bandwidth: selectable in 30 steps between 100 Hz and 10 MHz Measurement time: automatic or adjustable between 0.5 ms and 900 s Detector modes: continuous or periodic Squelch: adjustable in steps of 1 db in the range from 30 dbµv to +130 dbµv Automatic frequency control (AFC): if AFC is on, the receiver frequency is retuned within the IF bandwidth Level detector: for level measurements, the detector can be switched to AVG (average), peak, RMS or fast Frequency offset detector Attenuator: manual mode (0 db to 40 db) or automatic mode Gain control (GC): automatic (AGC) and manual (MGC); MGC covers an input signal range from 30 dbµv to +130 dbµv Video panorama: spectrum of demodulated signal with analysis functions (AM2, FM2) IF panorama (option): span from 10 khz to 9.6 MHz ITU measurements (option): AM modulation index (AM+, AM, AM) FM deviation: FM+, FM, FM φm deviation: 0 π to 4 π Bandwidth: 0 Hz to 9.6 MHz In memory scan mode, the receiver settings for monitoring up to 10 000 channels can be configured. These channels can be scanned using the Memory Scan command. A single channel can be called with the Recall command. The squelch threshold serves as a criterion for dwelling on a frequency or switching to the next channel. If the signal level exceeds the threshold, the receiver stops for the set dwell time. The following parameters can be set for each channel: Memory location status Frequency Demodulation mode Bandwidth Attenuation AFC settings Squelch threshold Antenna selection In frequency scan mode, the start and stop frequency and the step width for monitoring a frequency range are specified. The squelch threshold acts in the same way as with the memory scan. The receiver settings apply to the entire scan range. In memory scan or frequency scan mode, different selectable measurements (e.g. level offset, AM modulation index, FM deviation, bandwidth) are performed in parallel. In panorama scan mode, the receiver is tuned from the start to the stop frequency in steps of approx. 10 MHz and performs a high-resolution FFT at each step, allowing extremely high scan speeds of up to 34 GHz/s. The resolution bandwidth can be selected in the range from 125 Hz to 100 khz. 4 EM510_bro_en_5213-7731-32_v0200.indd 4 27.05.2015 16:01:59

Operation using standard software and PC The receiver comes with comprehensive operating software. The software is easily and quickly installed on the control PC, after which the receiver can be operated with full functionality. Depending on the options installed, the following results are displayed on the PC in realtime: Level, offset, modulation parameters, bandwidth Frequency scan Memory scan Spectra RF panorama IF panorama Video panorama Waterfall display of spectra The windows for spectra and waterfall can be adapted to suit different tasks. RF panorama, IF panorama and waterfall. Rohde & Schwarz R&S EM510 HF Digital Wideband Receiver 5 EM510_bro_en_5213-7731-32_v0200.indd 5 27.05.2015 16:01:59

Uses Due to its high scan speed, the receiver is ideally suited for fast, reliable detection of all signal types in the vast field of civil radiomonitoring. From fixed-frequency emissions and signals with rapidly changing frequency to periodically or nonperiodically pulsed emissions, nothing in the scenario is left undetected. The receiver s functionality encompasses the following: Detection of signals in the RF spectrum Memory scan of up to 10 000 memory channels Frequency scan in specified fre quency ranges Visualization of the signal and the signal environment Recording of baseband and audio data Demodulation of the signal Audio monitoring of AM, FM, CW and SSB transmissions Signal analysis Pulse detection and measurements Civil monitoring in line with ITU guidelines Owing to its performance, the EM510 meets all requirements for measurements in line with the ITU-R specifications (ITU Spectrum Monitoring Handbook, 2002). If the EM510IM option is installed, the following measurements can be performed: Frequency and frequency deviation in line with ITU-R SM377 Field strength in line with ITU-R SM378 Modulation in line with ITU-R SM328 Spectrum occupancy on the control PC in line with ITU-R SM182/SM328 Bandwidth in line with ITU-R SM443 The video panorama with AM, FM, AM2, FM2, I/Q and I/Q2 functions makes it possible to visualize the demodulated spectrum. In the AM2 and FM2 modes, most digi tally modulated signals can be identified, and further measurements performed as, for example, the following: Symbol rate Chip rate of DSSS transmissions FSK transmission. 6 EM510_bro_en_5213-7731-32_v0200.indd 6 27.05.2015 16:02:00

Customer-specific systems Wideband and narrowband The LAN control interface of the EM510 makes the receiver perfectly suited for configuring customer-specific system solutions. All interfaces are open and well documented. The protocol on the LAN interface is compliant with the standard commands for progammable instruments (SCPI) command syntax. All special functions, such as panorama scan, IF panorama, video panorama and ITU measurements, are integrated in the receiver and therefore require no additional hardware. The EM510 is a wideband receiver for high-speed scanning, monitoring and analysis tasks. Due to its design, it is also ideally suited for narrowband a pplications. Rohde & Schwarz also offers the EM010 digital VXI HF receiver. Due to its design (1 VXI slot), the EM010 is predestined for multichannel narrowband receive systems (see EM010 data sheet, PD 5213.5816.32). IF spectrum (zoomed) for measurements. Reception of a digital radio mondial (DRM) signal. Rohde & Schwarz R&S EM510 HF Digital Wideband Receiver 7 EM510_bro_en_5213-7731-32_v0200.indd 7 27.05.2015 16:02:00

Standard-compliant design The receiver is designed for stationary and mobile use. Thorough shielding and filtering of all input and output lines ensure extremely low EMI as well as high electromagnetic immunity. For use in vehicles, the receiver can be powered directly from the vehicle s battery via the DC input. Self-diagnosis The receiver is continuously monitored by automatic builtin tests (BITs). If deviations from the nominal values are detected, an error message with a code for displaying the error type is generated. For detailed information, the values of the internal test probes, including the upper and lower limits, can be output on the user interface. All outof-tolerance values are marked. The complete signal path between the antenna input and the demodulated output can be checked by means of a user-triggered loop test. This test is executed with internally generated and modulated signals. 8 EM510_bro_en_5213-7731-32_v0200.indd 8 27.05.2015 16:02:00

Specifications Specifications Frequency Frequency range Frequency resolution 9 khz to 32 MHz, < 1 MHz and > 30 MHz with reduced performance 1 Hz Frequency accuracy 1 10 7 Aging per year 1 10 7 Input for external reference 10 MHz Phase noise 130 dbc (1 Hz) at 1 khz offset, typ. 140 dbc (1 Hz) 0 Hz to ±8 khz BFO settable Antenna input BNC socket, 50 Ω VSWR Input level 2.5 f = 400 khz to 32 MHz 137 dbm to +10 dbm ( 30 dbµv to +117 dbµv) f < 400 khz 137 dbm to +6 dbm ( 30 dbµv to +113 dbµv) 9 khz to 400 khz lowpass filter 400 khz to 32 MHz switchable highpass/lowpass filters Max. input level (nondestructive) Preselection +15 dbm Input attenuation automatically or manually switchable Immunity to interference Aliasing suppression Inherent spurious signals 90 db, typ. 120 db normal mode 110 dbm LOW DIST 6 dbm Linearity Measurement level NORM 17 dbm Second order intercept point low distortion mode > 70 dbm, typ. 80 dbm, f = 1 MHz to 32 MHz normal mode > 50 dbm, typ. 65 dbm, f = 1 MHz to 35 MHz Third order intercept point low distortion mode 30 dbm, typ. 35 dbm, f = 1 MHz to 32 MHz normal mode 20 dbm, typ. 25 dbm, f = 1 MHz to 32 MHz Noise figure low distortion mode 26 db, typ. 22 db, f = 400 khz to 30 MHz normal mode 15 db, typ. 12 db, f = 400 khz to 30 MHz Sensitivity normal mode AM bandwidth = 6 khz, SINAD = 10 db fmod = 1 khz, m = 0.5 bandwidth = 15 khz, SINAD = 20 db fmod = 1 khz, deviation = 5 khz bandwidth = 2.4 khz, SINAD = 10 db measurement with telephone filter in line with ITU-T 1 µv ( 107 dbm), f = 400 khz to 30 MHz 1 µv ( 107 dbm), f = 400 khz to 30 MHz 0.5 µv ( 113 dbm), f = 400 khz to 30 MHz CW bandwidth = 600 Hz, SINAD = 10 db 0.25 µv ( 119 dbm), f = 400 khz to 30 MHz Demodulation modes all IF bandwidths AM, FM, PM, pulse, I/Q IF bandwidth 9 khz USB, LSB, CW IF bandwidth 1 khz ISB For demodulation, level and offset measurement (3 db bandwidth) 30 filters Shape factor (3 db:60 db) for 100 Hz to 5 MHz filters 100/150/300/600 Hz 1/1.5/2.1/2.4/2.7/3.1/4/4.8/6/9/12/15/30/50/120/ 150/250/300/500/800 khz 1/1.25/1.5/2/5/10 MHz 1:1.6 for 10 MHz filter 1:1.3 Audio filters 300 Hz to 3.3 khz notch/noise suppression/bandpass FM LSB/USB IF bandwidths Squelch (level squelch) 30 dbµv to +130 dbµv, settable in 1 db steps Gain control AGC, MGC, 30 dbµv to +130 dbµv AGC modes: fast/default/slow MGC settable in 1 db steps automatic retuning for frequency-unstable signals ± ½ IF bandwidth 16 bit Automatic frequency control (AFC) ADC resolution 100 Hz to 10 MHz Rohde & Schwarz R&S EM510 HF Digital Wideband Receiver 9 EM510_bro_en_5213-7731-32_v0200.indd 9 27.05.2015 16:02:00

Specifications Level and offset measurement Signal level 30 dbµv to +130 dbµv, resolution 0.1 db Indication errors max. ±1.5 db, typ. ±1.0 db Level indication mode Offset AVG, peak, fast, RMS 100 Hz to 10 MHz up to ± ½ IF bandwidth, resolution 1 Hz 10 khz to 9.6 MHz 10/25/50/100/150/256/300/400/600/800 khz/ 1.2/2.4/4.8/9.6 MHz IF panorama (with EM510SU option) Span internal FFT (2048 points), typ. 20 pictures/s Modulation measurement (with EM510IM option) AM (modulation index) AM, AM+, AM m = 0 % to 999.9 %; resolution 0.1 % fmax = 4 MHz < 5 % with bandwidth 1 MHz < 7 % with bandwidth > 1 MHz (S/N > 40 db, AF = 1 khz, measurement time <1 s) FM, FM+, FM f = 0 Hz to 4 MHz, resolution 0.001 khz fmax = 4 MHz (fmod + deviation) < 2 % of used IF bandwidth (absolute) (S/N > 40 db, AF = 1 khz, measurement time < 1 s) φ = 0 rad to 12.5 rad; resolution 0.01 rad fmax = 4 MHz (fmod + deviation) < 0.1 rad (S/N > 40 db, AF = 1 khz, measurement time < 1 s) up to 9.6 MHz automatic; > 9.6 MHz with external software, x db and ß % method Indication error FM (FM deviation) Indication error φm Indication error Bandwidth measurement Scan characteristics Memory scan Frequency scan Panorama scan with EM 510PS option 10 000 programmable memory locations, scan speed up to 1500 channels/s user-selectable start/stop frequency and step width, 100 frequencies suppressible, scan speed up to 1500 channels/s RF spectrum with user-selectable start/stop frequency, step width 125/250/500/625 Hz/ 1.25/2.5/3.125/6.25/12.5/25/50/100 khz, scan speed up to 34 GHz/s Inputs/outputs Inputs antenna input 9 khz to 32 MHz, 50 Ω, BNC socket external reference input 10 MHz, BNC socket input level 0 dbm to +10 dbm video analog AM (A) and FM (B), DC up to ½ IF bandwidth IF analog, controlled, two channels Outputs Video A, video B Video digital bandwidth 500 khz settable center frequency 0 Hz to 21.4 MHz, bandwidth up to 5 MHz, depending on IF filter and center frequency, level 0 dbm LAN bandwidth 5 MHz FPDP I/Q digital bandwidth 1 MHz LAN bandwidth 10 MHz FPDP 10 EM510_bro_en_5213-7731-32_v0200.indd 10 27.05.2015 16:02:01

Specifications Audio analog headphone connector: 0 V to 2 V Ri = 100 Ω f = 10 Hz/300 Hz to 12.5 khz (depending on IF filter and modulation) AF line: 0.5 V ± 0.3 V (m = 0.5) Ri = 100 Ω f = 10 Hz/300 Hz to 12.5 khz (depending on IF filter and modulation) AF symmetrical: 0.4 V ± 0.2 V (m = 0.5) Ri = 600 Ω f = 100 Hz to 12.5 khz LAN AES/EBU interface (ANSI 4.40) 10 MHz, output level 7 dbm to 13 dbm Audio digital Internal reference output Built-in test monitoring of test signals by means of loop test as short or long test, continuous monitoring of test points Data and control interfaces LAN Ethernet 10/100BASE-T Optical data interface FPDP, 1 Gbit/s General data Climatic conditions Temperature in line with EN 60068-2-1, EN 60068-2-2 operating temperature range 0 C to +50 C permissible temperature range 10 C to +55 C storage temperature range 40 C to +70 C Humidity max. 95 %, cycl. test at +25 C/+55 C, in line with EN 60068-2-30 40 g/11 ms, in line with EN 60068-2-27, MIL-STD-810E, method 516.4 in line with EN 60068-2-6, EN 61010-1 MIL-T-28800D, class 5 in line with EN 60068-2-64 Shock Vibration sinusoidal noise Electromagnetic compatibility (EMC) in line with EN 300339, ETSI EN 301489-1, ETSI EN 301489-22 MIL-STD-461E, CE 102, RE 102, RS 103 30 000 h (IEC 1709) MTBF Power supply Dimensions AC 100 V to 240 V (47 Hz to 63 Hz), typ. 45 VA DC 12 V/24 V, typ. 33 VA W H D 19", 2 HU, 426.7 mm 87.6 mm 450 mm (16.80 in 3.45 in 17.72 in) (without feet or handles) 8.5 kg (18.74 lb) Weight Ordering information Designation Type Order No. HF Digital Wideband Receiver EM510 4065.7728.02 Panorama Scan (RF spectrum) EM510PS 4065.8430.02 IF Panorama (IF spectrum) EM510SU 4065.8499.02 ITU Measurement Software 1) EM510IM 4065.8401.02 SEL CALL Analysis EM510SL 4065.8460.02 Options 1) R&S EM510SU IF panorama option is included in the R&S EM510IM option. Rohde & Schwarz R&S EM510 HF Digital Wideband Receiver 11 EM510_bro_en_5213-7731-32_v0200.indd 11 27.05.2015 16:02:01

Service that adds value Worldwide Local and personalized Customized and flexible Uncompromising quality Long-term dependability About Rohde & Schwarz The Rohde & Schwarz electronics group is a leading supplier of solutions in the fields of test and measurement, broadcast and media, secure communications, cyber security, and radiomonitor ing and radiolocation. Founded more than 80 years ago, this independent global company has an extensive sales network and is present in more than 70 countries. The company is headquartered in Munich, Germany. Sustainable product design Environmental compatibility and eco-footprint Energy efficiency and low emissions Longevity and optimized total cost of ownership Certified Quality Management ISO 9001 Certified Environmental Management ISO 14001 Rohde & Schwarz GmbH & Co. KG www.rohde-schwarz.com R&S is a registered trademark of Rohde & Schwarz GmbH & Co. KG Trade names are trademarks of the owners PD 5213.7731.32 Version 02.00 May 2015 (fi) R&S EM510 HF Digital Wideband Receiver Data without tolerance limits is not binding Subject to change 2007-2015 Rohde & Schwarz GmbH & Co. KG 81671 Munich, Germany 5213.7731.32 02.00 PDP 1 en Regional contact Europe, Africa, Middle East +49 89 4129 12345 customersupport@rohde-schwarz.com North America 1 888 TEST RSA (1 888 837 87 72) customer.support@rsa.rohde-schwarz.com Latin America +1 410 910 79 88 customersupport.la@rohde-schwarz.com Asia Pacific +65 65 13 04 88 customersupport.asia@rohde-schwarz.com China +86 800 810 82 28 +86 400 650 58 96 customersupport.china@rohde-schwarz.com 5213773132 EM510_bro_en_5213-7731-32_v0200.indd 12 27.05.2015 16:02:01