Operating manual handylab multi 12 g/l ARng ph/dissolved Oxygen/Conductivity Measuring Instrument

Handheld meter Oxi 3300i/3400i

Handheld meter Cond 330i/340i

Operating manual. handylab LF 12. Tref25 nlf C TP STO O RCL. Conductivity Meter. ba75367d04 01/2011

Operating manual. ph/oxi 3400i. mg/l. ARng. ph/oxygen measuring instrument. ba75686e01 01/2007

Operating manual. Multi 340i. mg/l. ARng. ph/dissolved Oxygen/Conductivity Measuring Instrument. ba52318e02 03/2004

Handheld meter Cond 3150i

Thermo Scientific Orion Star A329 Portable ph/ise/conductivity/rdo/do Meter. Reference Guide

Operating manual Cond 1970i Portable conductivity measuring instrument

Conductivity measurement

Operating manual. Oxi 1970i ON / OFF AUTO READ RUN / ENTER. RCL STO Oxi 1970i. Portable oxygen measuring instrument. ba75691e01 01/2007

COND 200. Conductivity/TDS/Salinity Meter Operating instructions. Meas Cal. Hold Rcl Store. On Off Menu

Operating manual. Oxi 197i ON / OFF AUTO READ RUN / ENTER. RCL STO Oxi 197i. Portable oxygen measuring instrument. ba75335e02 11/2004

Thermo Scientific Orion Star A111 ph Benchtop Meter

Multi 197i. Operating manual. Portable ph / oxygen / conductivity measuring instrument. ba75339e03 01/2005 ON / OFF AUTO READ RUN / ENTER

Thermo Scientific Orion Star A212 Benchtop and Star A222 and Star A322 Portable Conductivity Meters. Reference Guide

Colorado Series. CR-30 Portable Conductivity / Temperature / TDS / Salinity Meter Operation Manual

inolab Multi IDS ph, ISE, CONDUCTIVITY AND DISSOLVED OXYGEN MEASUREMENT ACCURATE, COMPLIANT, SECURE

HD HD HD HD HD

INSTRUCTION MANUAL DISSOLVED OXYGEN-METER MODEL CDO-01

OPERATING MANUAL. ba77043e02 10/2015 LF 413T IDS LF 413T 3M IDS CONDUCTIVITY CELL

GREISINGER electronic GmbH D Regenstauf, Hans-Sachs-Straße 26 phone: / , fax: / ,

Multi Water Quality Checker U-50 Series Instruction Manual CODE:GZ

200 us/2 ms/20 ms/200 ms, TDS ( PPM ) Real time data logger, Data logger no., RS232 CONDUCTIVITY METER Model : YK-2005CD

JUMO ecotrans Lf 03 Microprocessor Transmitter / Switching Device for conductivity or resistivity and temperature

Analytical Transmitters

Corporate Profile. needs and product demands. CON 08X /03 Rev 0

1000TR. Instructions

Denver Instrument Company

PH/ORP, DO CD/TDS METER Model : YK-2005WA

Please completely read through operating instructions! Do not discard! The warranty shall be invalidated by damage caused by operating errors!

Measuring and Controlling Unit Multronic OC

Please enter the identity code of your device here!

JUMO Wtrans E01. Measuring probe for humidity, temperature, and CO 2 with wireless data transmission. Brief description. Universal Wtrans receiver

ph, ORP, CD, TDS, DO, SALT METER

Signet 9950 Dual Channel Transmitter

The LEBOW 7554 Operator's Manual 7.2

Conductivity. Handheld conductivity meters

Please enter the identity code of your device here!

Thermo Scientific Orion Star A216 Benchtop and Star A326 Portable ph/rdo/do Meters. Reference Guide

High-quality digital indicator for panel mounting Model DI35-M, with multi-function input Model DI35-D, with two inputs for standard signals

- HD HD HD pag. 338 Portable ph meters. - HD HD pag. 342 Portable ph and conductivity meters

High-precision process calibrator Model CED7000

GOSSEN METRAWATT. Testers

Operating Instructions Liquiline To Go CYM290

ICAM. Electronics & Software. Industrial Charge Amplifier for Applications in Manufacturing. Type 5073A...

SGD-EEM «MEDUSA» GEOELECTRICAL MULTIFUNCTION RECEIVER

PH METER OPERATION MANUAL. Model : PH-208

U S E R S M A N U A L

Multi-parameter measurement

Temperature head transmitter itemp PCP TMT 181

Stratos Evo. Power supply for external 2-wire transmitters

dtrans Az 01 µp Indicator/Controller for analytical measurement

Dial-type digital bar graph. LEDs for Open Collector, Relays and Warning Indicator

Technical Information Orbipac CPF81D/CPF82D and CPF81/CPF82

Conductivity-Converter

JUMO Wtrans Receiver Universal Receiver for JUMO Wireless Measuring Probes

Fluke Fluke-Direct.ca. Three-Phase Power Logger. Technical Data

Wireless Data Logger RTR-500 Series Data Loggers Features and Specs

ION450. Reference Manual. Ion Analyser D21M079

SPECIFICATION SHEET DISSOLVED OXYGEN ANALYZER/TRANSMITTER SYSTEM CONFIGURATION

Drinking water monitoring

METRISO. Analog Insulation, Low Resistance and Voltage Measurement Instrument /9.14

Bedienungsanleitung. Instructions d utilisation Emetteur HS 1 BiSecur / HS 4 BiSecur. Bedieningshandleiding

Technical Information Condumax CLS21D/CLS21

( F L O W I Z F A M I L Y )

Model. Instruction Manual. Digital ph Pen. reedinstruments. REED Instruments

JUMO Wtrans Receiver with Wireless Data Transmission

GRUNDFOS DATA BOOKLET DIP. Measuring amplifiers and controllers, preassembled systems. Up to 3 parameters (Cl 2, ClO 2, O 3, ph, ORP)

Instruction manual SMART 96-2 / WG-2 ph

HZJF-9007 Fully Functional Partial Discharge Inspector USER MANUAL. Huazheng Electric Manufacturing(Baoding) Co.,Ltd

Fluke 125. Getting Started. Industrial ScopeMeter

TDT Biological Amplifier User s Guide? TDT

Heat meter Q heat 5 US

WATERPROOF CONDUCTIVITY METER CC- 411 USER S MANUAL

B850 Boiler House Energy Monitor

DTI-1000 & STS-100/102. Digital Temperature Indicator & STS Reference Sensor

Thermo Scientific Orion Star A214 Benchtop and Star A324 Portable ph/ise Meters. Reference Guide

Thermo Scientific Orion Star A211 Benchtop and Star A221 and Star A321 Portable ph Meters. Reference Guide

JUMO dtrans T01 HART / T01T HART / T01 Junior / T01 Ex / T01 HART Ex Programmable 2-wire transmitter

Instruction manual SMART 96-2 / WG-2 LF

} Max. Load Resistance : 750Ω when power supply voltage is 24V DC (Max. load resistance (Ω) = 50x Power Supply Voltage -450 ).

Please enter the identity code of your device here!

Instruction also available on

MXD70 Series. Multi-parameter Monitor. Modbus RS485 Interface Operating Guide

Signet 9900 Transmitter

USER MANUAL DOCUMENT # REF. ProDSS USER MANUAL

Instruction Manual COND METER DS-72

Seven2Go. Everywhere You Measure ph Quality Measurement Made Mobile. Seven2Go. ph / ORP Conductivity Ion Concentration Dissolved Oxygen

For reliable and continuous measurement of water quality insist on Aqua SMARTPro Transmitters

vscan Data Sheet V1.0

SonoMeter 31 Energy Meters

Signet 9950 Dual Channel Transmitter

Maintenance: Check the measurement signal: regularly required once a month Calibration: typically 6 to 12 months after installation

ecotrans Lf 01/02 Transmitter / Switching Device for Conductivity Type B Operating Instructions 02.07/

MEAS CAL ALARM CONF APT2000 TC

Operating Instructions. Indication and adjustment module PLICSCOM

OEM pressure transmitter for general industrial applications Models O-10 (T), O-10 (5)

HG G B. Gyroscope. Gyro for AGV. Device Description HG G B. Innovation through Guidance. Autonomous Vehicles

Signet 9900 Transmitter

Transcription:

Bedienungsanleitung Operating manual Mode d emploi Instrucciones de operación ba7542defs M PRT CAL STO O ESC Universal-Taschenmessgerät Seite 3 Universal Pocket Meter Page 7 Instrument de poche universel Page 3 Instrumento manual de medición universal Página 45 ba7542defs02 0/2004

Contents - Contents Safety........................................... 8 Display and socket field............................. 8 Line power....................................... 9 Switching on the meter.............................. 9 Overview of the functions............................ 20 Navigation in menus................................ 2 Measuring functions................................ 22 Calibration....................................... 22 Measuring menus.................................. 23 System menu..................................... 26 Technical data.................................... 27 Note The process of consistently improving our products includes the continuous further development of instrument firmware. The current firmware is available on the Internet. It can easily be downloaded on your meter using the enclosed AK 340/B cable and a PC. For more detailed information, refer to the appendix of the detailed operating manual or to the Internet under http://www.wtw.com. 7

Safety Safety Safety instructions The individual chapters of this operating manual use safety instructions such as the label shown below to indicate various hazards or dangers: Caution indicates instructions that must be followed precisely in order to avoid the possibility of slight injuries or damage to the instrument or the environment. Display and socket field Display Measured parameter Measured value (with unit) ph 6.949 24.0 C O 2 7.29 mg/l 24.0 C [SAL] 73 µs/cm 24.0 C [nlf][tr25] 05.09.03 09:25 Temperature display Sensor symbol Status line Socket field 5 4 DO sensor or conductivity measuring cell or combined conductivity / DO sensor 2 ph electrode, ISE electrode or ISE combination electrode 3 ph temperature sensor, reference electrode 4 Power pack 5 RS232 serial interface 2 3 8

Line power Line power The power pack supplies the measuring instrument with low voltage (9 V DC). At the same time, the rechargeable batteries are charged (approx. 36 hours). The LoBat display indicator appears if the batteries are nearly empty. Caution The line voltage at the operating site must lie within the input voltage range of the original power pack (see TECHNICAL DATA). Caution Only use original power packs (see TECHNICAL DATA). 4 2 3 If necessary, replace the Euro plug () on the power pack (2) by the country-specific plug suitable for your country. Connect the plug (3) to the socket (4) of the meter. Connect the power pack (2) to an easily accessible power socket. Switching on the meter Press the < > key. An opening screen with instrument identification data appears on the screen for a short time. Subsequently, the measured value display appears. The meter displays the measuring windows of all connected sensors. 9

Overview of the functions Overview of the functions Measuring menu Settings / actions (inter alia): - Calibration procedure - Calibration interval - Manual temperature input - Sensor settings - Measuring options - Reset sensor settings ESC MENU ENTER (shortly) Measured value display Select measuring window with M Select measured variable with : ESC ph - mv - ISE mg/l O2 - % O2 - p O2 - - TDS - Sal ESC MENU ENTER CAL Menu-guided calibration for the current measuring mode (for a longer time) System menu Settings/ actions (inter alia): - View stored measuring data and transmit them to the interface - Erase stored measuring data - View calibration records and transmit them to the interface - Interface parameters - Display, language, date, time - Reset system settings Data storage and print functions: PRT Press shortly: Transmit current measuring data to the interface. Transmit the displayed calibration record to the interface Press for a long time: Configure the automatic download at intervals to the interface STO Press shortly: Press for a long time: Transmit current measuring data to the data storage and interface Configure the automatic download at intervals to the data storage and interface 20

Navigation in menus Navigation in menus The menus for settings and dialogs in courses contain further submenus. The selection is made with the <> <> keys. The current selection is displayed in reverse video. Submenus The name of the submenu is displayed at the upper edge of the frame. Submenus are opened by confirming with <MENU/ENTER>. Example: System General Interface Clock function Reset Settings Settings are indicated by a colon. The current setting is displayed on the right-hand side. The setting mode is opened with <MENU/ENTER>. Subsequently, the setting can be changed with <> <> and <MENU/ENTER>. Example: System Language: Deutsch Beep: Off Illumination: On Contrast: 48 % Temperature unit: C Switchoff time: 30 min Functions Functions are designated by the name of the function. They are immediately carried out by confirming with <MENU/ENTER>. Example: Display the Calibration record function. ph Calibration type: Calibration interval: Unit for slope: Calibration record : i 2.00 4.0 7.00 0.0 TEC 7 d mv/ph Messages (i) Information or operating instructions are designated by the i symbol. They cannot be selected. 2

Measuring functions Measuring functions AutoRead (drift control) Temperature measurement in ph and ISE measurements Salt content correction in DO measurements Temperature compensation and reference temperature of conductivity measurements The AutoRead function indicates the stability of the measurement signal. It is active during all measurements. The display of the measured parameter flashes as long as the specified stability of the measured value is not kept. When using electrodes without an integrated temperature sensor you can use the temperature sensor of a DO sensor or a conductivity measuring cell. The meter recognizes suitable sensors and switches on the temperature measurement. If the instrument measures the temperature, it is displayed with a high resolution (0. C); if the temperature is entered manually, it is displayed with a low resolution ( C). The temperature is entered manually in the measuring menu. When measuring the concentration of solutions with a salt content of more than g/l, a salt content correction is required. When using the ConOx double sensor, you can measure the salinity in the solution simultaneously and include it in the DO measurement automatically. When the salt content correction is switched on, the [SAL] indicator appears in the measuring window. The salt content correction is set in the DO measuring menu. You can select from the following settings: Nonlinear temperature compensation [nlf] according to EN 27 888 Linear temperature compensation [lin] with selectable coefficients of 0.000... 3.000 %/K No temperature compensation The setting of the temperature compensation and entry of the reference temperature are carried out in the conductivity measuring menu. Calibration Procedure AutoRead (drift control) Calibration result Select the required measured parameter with <> <> and <M>. Ensure that the correct calibration procedure is set in the relevant measuring menu (e.g. buffer sets for ph calibration). Then switch to the measured value display and press <CAL>. The guides you through the course of the calibration step by step. With automatic calibration, the measured value is only accepted when the stability criterion is met. This can be terminated prematurely and the current measured value taken over with <MENU/ENTER> at any time. When a calibration is finished, the new calibration values are displayed as an informative message (i symbol) first. Then you can decide whether you want to take over these values of the new calibration or whether you want to continue measuring with the old calibration data. After accepting the new calibration values the calibration record is displayed. 22

Measuring menus Measuring menus Measuring menu: ph/orp Menu item Possible setting Description Calibration interval... 999 d Calibration interval for the ph electrode (in days). The meter reminds you to calibrate regularly by the flashing sensor symbol. Calibration type Unit for slope TEC NIST/DIN ConCal mv/ph % Buffer sets for ph calibration: TEC: 2.00 / 4.0 / 7.00 / 0.0 NIST/DIN:.679 / 4.006 / 6.865 / 9.80 / 2.454 ConCal: ph 7.0 ± 0.5 and any other buffer solution Unit of the slope. The % display refers to the Nernst slope of -59.6 mv/ph (00 x determined slope/nernst slope). Calibration record - Displays the calibration record of the last calibration. Man. temperature -20... +30 C Entry of the manually determined temperature. For measurements without temperature sensor only. Reset - Resets all sensor settings to the delivery condition. High resolution On Off Resolution of the ph display: On = 0.00 Off = 0.0 Measuring menu: ISE Menu item Possible setting Description Calibration record - Displays the calibration record of the last calibration. Man. temperature -20... +30 C Entry of the manually determined temperature. For measurements without temperature sensor only. 23

Measuring menus Measuring menu: DO Menu item Possible setting Description Calibration interval... 999 d Calibration interval for the DO sensor (in days). The meter reminds you to calibrate regularly by the flashing sensor symbol. Comparison meas. On Off Enables to adjust the measured value with the aid of a comparison measurement, e.g. Winkler titration. Calibration record - Displays the calibration record of the last calibration. Reset - Resets all sensor settings to the delivery condition. Sal automatic Sal correction On Off On Off Automatic salt content correction for concentration measurements. Note: This function is available with the ConOx double sensor only. Manual salt content correction for concentration measurements. Salinity 0.0... 70.0 Salinity or salinity equivalent for the salt content correction. This function is only available if the manual salt content correction is switched on. 24

Measuring menus Measuring menu: conductivity Menu item Possible setting Description Calibration interval Calibration record... 999 d Calibration interval for the measuring cell (in days). The meter reminds you to calibrate regularly by the flashing sensor symbol. - Displays the calibration record of the last calibration. Reset - Resets all sensor settings to the delivery condition. Temp. comp. (TC) / Reference temp. Temp. comp. (TC) / Compensation Temp. comp. (TC) / Linear coeff. Measuring cell 20 C 25 C nlf lin Off 0.000... 3.000 %/K Cal LR325/00 Reference temperature. This setting is only available when the conductivity or specific resistance display is set. Procedure for temperature compensation. This setting is only available when the conductivity or specific resistance display is set. Coefficient of the linear temperature compensation. This setting is only available when the linear temperature compensation is set. Measuring cell used Measuring cells the cell constant of which is determined by calibration in the KCL control standard solution. Calibration ranges: 0.450 to 0.500 cm - and 0.800 to.200 cm - The currently valid cell constant is displayed in the status line. LR 325/00 measuring cell, nominal cell constant 0.00 cm -. The cell constant is permanently set. 25

System menu Measuring menu: conductivity (continued) Menu item Measuring cell Possible Setting Description Measuring cell used LR325/0 LR 325/0 measuring cell, nominal cell constant 0.00 cm -. The cell constant can be adjusted in the range from 0.090 to 0.0 cm -. man Any measuring cells with freely adjustable cell constants in the range from 0.250 to 25.000 cm -. Cell constant Man. cell const. 0.090 to Display and setting option of the 0.0 cm - cell constant of the LR 325/0 measuring cell. 0.250 to 25.000 cm - Display and setting option of the cell constant of any measuring cells (man). System menu The following settings and functions are available in the system menu and its submenus: Viewing, transmitting and erasing stored measuring data Viewing and transmitting calibration records Display illumination and contrast Changing the unit of the temperature display ( C <-> F) Setting the automatic switchoff Configuring the data interface Setting the menu language, date and time Resetting all sensor-independent system settings to the default condition 26

Technical data Technical data General data Dimensions approx. 72 x 80 x 37 mm Weight approx. 0.3 kg (without power pack) Mechanical structure Type of protection IP 66 Electrical safety Protective class III Test certificates cetlus, CE Ambient conditions Storage - 25 C... + 65 C Operation -0 C... + 55 C Climatic class 2 Power supply Rechargeable batteries Operational life Power pack (charging device) 4 x.2 V nickel metal hydride (NiMH), type AA up to 500 h with one battery charging FRIWO FW7555M/09, 5.432.500-00 Friwo Part. No. 883259 Input: 00... 240 V ~ / 50... 60 Hz / 400 ma Output: 9 V = /,5 A Connection max. overvoltage category II Primary plugs contained in the scope of delivery: Euro, US, UK and Australian. Serial interface Guidelines and norms used Connection of the cable AK 340/B or AK 325/S Baud rate Adjustable: 200, 2400, 4800, 9600, 9200 baud Type RS232, data output Data bits 8 Stop bits 2 Parity None Handshake RTS/CTS Cable length Max. 5m EMC EC guideline 89/336/EEC EN 6326-:998 EN 6000-3-2 A4:2000 EN 6000-3-3:995 FCC Class A Instrument safety E.C. guideline 73/23/EEC EN 600- A2:995 Climatic class VDI/VDE 3540 IP protection EN 60529:99 27

Technical data Measuring ranges, resolution, accuracy ph/orp Measuring ranges, resolution Manual temperature input Variable Measuring range Resolution ph - 2.000... + 20.000-2.00... + 20.00 U [mv] - 999.9... + 999.9-2000... + 2000 0.00 0.0 0. T [ C] - 5.0... + 05.0 0. Variable Range Increment T manual [ C] - 20... + 30 Accuracy (± digit) Variable Accuracy Temperature of sample ph * ± 0.004 + 5 C... + 35 C U [mv] / range - 999.9... + 999.9 ± 0.2 + 5 C... + 35 C - 2000... + 2000 ± + 5 C... + 35 C T [ C] / temperature sensor NTC 30 ± 0.2 0 C... + 55 C PT 000 ± 0.3 0 C... + 55 C * when measuring in a range of ± 2 ph around a calibration point ISE Measuring ranges, resolution Manual temperature input Variable Measuring range Resolution ISE [mg/l] 0.000... 0.000 0.00... 00.00 0.0... 00.0 0... 2000 0.00 0.0 0. Variable Range Increment T manual [ C] - 20... + 30 Dissolved oxygen Measuring ranges, resolution Note: The values quoted in brackets apply especially for the DurOx 325 sensor. Variable Measuring range Resolution DO concentration [mg/l] 0... 20.00 (0... 20.0) 0... 90.0 (0... 90) 0.0 (0.) 0. () 28

Technical data Measuring ranges, resolution (continued) Variable Measuring range Resolution DO saturation [%] 0... 200.0 (0... 200) 0... 600 DO partial pressure [mbar] 0... 200.0 (0... 200) 0... 250 T [ C] 0... 50.0 0. 0. () 0. () Accuracy (± digit) Variable Accuracy DO concentration [mg/l] DO saturation [%] DO partial pressure [mbar] ± 0.5 % of measured value at ambient temperature + 5 C... + 30 C ± 0.5% of measured value when measuring in the range of ± 0 K around the calibration temperature ± 0.5 % of measured value at ambient temperature + 5 C... + 30 C Correction functions Temperature compensation Salinity correction Air pressure correction Accuracy better than 2 % at 0... + 40 C 0... 70.0 SAL Automatic through integrated pressure sensor in the range of 500... 00 mbar Conductivity Measuring ranges, resolution Variable Measuring range Resolution [µs/cm] 0.000... 2.000* 0.00... 20.00** 0.0... 200.0 0... 2000 [ms/cm] 0.00... 20.00 0.0... 200.0 0... 2000 Specific resistance [kohm*cm] Specific resistance [MOhm*cm] 0.000... 2.000 0.00... 20.00 0.0... 200.0 0... 2000 0.00... 20.00 0.0... 200.0 0... 2000 SAL 0.0... 70.0 according to the IOT table 0.00 0.0 0. 0.0 0. 0.00 0.0 0. 0.0 0. 0. 29

Technical data Measuring ranges, resolution (continued) Variable Measuring range Resolution TDS [mg/l] 0... 2000 Factor can be set between 0.40 and.00 T [ C] - 5.0... + 05.0 0. * only possible with cells of the cell constant, 0.00 cm - ** only possible with cells of the cell constant, 0.00 cm - or 0.090... 0.0 cm - Cell constants Cell constant C Values Can be calibrated in the ranges Adjustable 0.450... 0.500 cm - 0.800....200 cm - 0.00 cm - (fixed) 0.090... 0.0 cm - 0.250... 25.000 cm - Reference temperature Reference temperature Adjustable Values 20 C (Tr20) 25 C (Tr25) Accuracy (± digit) Variable Accuracy Temperature of sample / Temperature compensation None (Off) ± 0.5 % Nonlinear (nlf) ± 0.5 % 0 C... + 35 C according to EN 27 888 ± 0.5 % + 35 C... + 50 C Extended nlf function according to WTW measurements Linear (lin) ± 0.5 % + 0 C... + 75 C SAL / range 0.0... 42.0 ± 0. + 5 C... + 25 C ± 0.2 + 25 C... + 30 C TDS [mg/l] ± T [ C] / temperature sensor NTC 30 ± 0.2 0 C... + 55 C PT 000 ± 0.3 0 C... + 55 C 30