III Lead ECG Pulse Measurement Sensor

Similar documents
Development of Electrocardiograph Monitoring System

Florida Atlantic University Biomedical Signal Processing Lab Experiment 2 Signal Transduction: Building an analog Electrocardiogram (ECG)

STM32 microcontroller core ECG acquisition Conditioning System. LIU Jia-ming, LI Zhi

A fully autonomous power management interface for frequency upconverting harvesters using load decoupling and inductor sharing

DESIGN OF A LOW COST EMG AMPLIFIER WITH DISCREET OP-AMPS FOR MACHINE CONTROL

BIOMEDICAL INSTRUMENTATION PROBLEM SHEET 1

Kanchan S. Shrikhande. Department of Instrumentation Engineering, Vivekanand Education Society s Institute of.

Bioelectric Signal Analog Front-End Module Electrocardiograph

Enhanced RF to DC converter with LC resonant circuit

Special-Purpose Operational Amplifier Circuits

CHAPTER 3. Instrumentation Amplifier (IA) Background. 3.1 Introduction. 3.2 Instrumentation Amplifier Architecture and Configurations

Design and Implementation of Digital Stethoscope using TFT Module and Matlab Visualisation Tool

A compact ultra wideband antenna with WiMax band rejection for energy scavenging

A new fuzzy self-tuning PD load frequency controller for micro-hydropower system

Design on Electrocardiosignal Detection Sensor

Lecture 4 Biopotential Amplifiers

1) Consider the circuit shown in figure below. Compute the output waveform for an input of 5kHz

DESIGN OF OTA-C FILTER FOR BIOMEDICAL APPLICATIONS

Wireless Transmission of Real Time Electrocardiogram (ECG) Signals through Radio Frequency (RF) Waves

Introduction (cont )

Inter-Ing INTERDISCIPLINARITY IN ENGINEERING SCIENTIFIC INTERNATIONAL CONFERENCE, TG. MUREŞ ROMÂNIA, November 2007.

Project 7: Seismic Sensor Amplifier and Geophone damping

ECG Project. Raphal Blanchet, Axel Boland, Thomas Donnay, Mario Jose Teles Varandas, University of Liege

Biomedical Instrumentation (BME420 ) Chapter 6: Biopotential Amplifiers John G. Webster 4 th Edition

Massachusetts Institute of Technology MIT

Influence of SDBD plasma aerodynamic actuation on flow control by AC power supply and AC-DC power supply

AD8232 EVALUATION BOARD DOCUMENTATION

EE 230 Experiment 10 ECG Measurements Spring 2010

BME 405 BIOMEDICAL ENGINEERING SENIOR DESIGN 1 Fall 2005 BME Design Mini-Project Project Title

Fuzzy Logic Controlled Solar Module for Driving Three- Phase Induction Motor

PORTABLE ECG MONITORING APPLICATION USING LOW POWER MIXED SIGNAL SOC ANURADHA JAKKEPALLI 1, K. SUDHAKAR 2

HUMAN DETECTION AND RESCUE USING BIO POTENTIAL SIGNALS

Assist Lecturer: Marwa Maki. Active Filters

Design of an insulator leakage current measurement system based on PLC

Bio-Potential Amplifiers

MAX44265 Evaluation Kit Evaluates: MAX44265

TRANSDUCER INTERFACE APPLICATIONS

Instrumentation amplifier

Ques on (2): [18 Marks] a) Draw the atrial synchronous Pacemaker block diagram and explain its operation. Benha University June 2013

EK307 Active Filters and Steady State Frequency Response

A Complete Analog Front-End IC Design for ECG Signal Acquisition

Chapter 15: Active Filters

Implementation of wireless ECG measurement system in ubiquitous health-care environment

A Dynamically Reconfigurable ECG Analog Front-End with a 2.5 Data-Dependent Power Reduction

In-depth Analysis of Cardiac Signals Using Novel Equipment and Software

Electrical current measurement system for energy harvesting applications

Design and Implementation of Low Cost ECG Monitoring System and Analysis using Smart Device

Inductive Power Supply for On-line Monitoring Device

LOW VOLTAGE / LOW POWER RAIL-TO-RAIL CMOS OPERATIONAL AMPLIFIER FOR PORTABLE ECG

Lab E5: Filters and Complex Impedance

The influence of non-audible plural high frequency electrical noise on the playback sound of audio equipment (2 nd report)

Investigation of Passive Filter for LED Lamp

AN-671 APPLICATION NOTE One Technology Way P.O. Box 9106 Norwood, MA Tel: 781/ Fax: 781/

The Performance Of SISO In Wireless Open-Access Research Platform (WARP) Using QAM Modulation

Electromagnetic energy harvester for atmospheric sensors on overhead power distribution lines

Data acquisition and instrumentation. Data acquisition

A control strategy for PV stand-alone applications

Assignment 11. 1) Using the LM741 op-amp IC a circuit is designed as shown, then find the output waveform for an input of 5kHz

INTERFACE ELECTRONICS FOR PERIPHERAL NERVE RECORDING AND SIGNAL PROCESSING KANOKWAN LIMNUSON. Submitted in partial fulfillment of the requirements

Deepali Shukla 1 (Asst.Professor), Vandana Pandya 2 (Asst.Professor) Medicaps Institute of Technology & Management, Indore (M.P.

6.101 Introductory Analog Electronics Laboratory

Transmit filter designs for ADSL modems

Design and Implementation of a New Gain Control RF Amplifier

DESIGN OF LOW POWER SAR ADC FOR ECG USING 45nm CMOS TECHNOLOGY

Bio-Impedance Spectroscopy (BIS) Measurement System for Wearable Devices

EG medlab. Three Lead ECG OEM board. Version Technical Manual. Medlab GmbH Three Lead ECG OEM Module EG01010 User Manual

An active filter offers the following advantages over a passive filter:

Analog Circuits and Systems

Active Filters - Revisited

HEART RATE COMPUTATION IMPLEMENTED ON FIELD PROGRAMMABLE GATE ARRAY BOARD. Abstract

Research on Parallel Three Phase PWM Converters base on RTDS

Biomedical. Measurement and Design ELEC4623. Lectures 9 and 10 Practical biopotential amplifier design and multilead ECG systems

Lab: Using filters to build an electrocardiograph (ECG or EKG)

Portable, Low Cost, Low Power Cardiac Interpreter

IMPROVEMENTS IN ELECTROCARDIOGRAPHY SMOOTHENING AND AMPLIFICATION

International Journal of Electronics and Communication Engineering & Technology (IJECET), ISSN COMMUNICATION ENGINEERING & TECHNOLOGY (IJECET)

Instrumentation Amplifier and Filter Design for Biopotential Acquisition System CHANG-HAO CHEN

THE BENEFITS OF DSP LOCK-IN AMPLIFIERS

DESIGN OF A PROGRAMMABLE LOW POWER LOW DROP-OUT REGULATOR

Intruder Alarm Name Mohamed Alsubaie MMU ID Supervisor Pr. Nicholas Bowring Subject Electronic Engineering Unit code 64ET3516

Development control systems takeover: subject robotic arm on the example anthropomorhic robot AR-601

Development of an alternative method for the calibration of ECG simulators

Laboratory Activities Handbook

Electrocardiogram (ECG)

Name Kyla Jackson, Todd Germeroth, Jake Spooler Date May 5, 2010 Lab 3E Group 3 Experiment Title Project Deliverable 3

Baseband simulation model of the vector rf voltage control system for the J-PARC RCS

UNIVERSITI MALAYSIA PERLIS

A Design Of Simple And Low Cost Heart Rate Monitor

Computer Control System Application for Electrical Engineering and Electrical Automation

EKT 314 ELECTRONIC INSTRUMENTATION

Used to overcome ventricular fibrillation may be due to coronary occlusion, shock, or abnormalities in blood chemistry

EE ELECTRICAL ENGINEERING AND INSTRUMENTATION

VivoSense. User Manual - Equivital Import Module. Vivonoetics, Inc. San Diego, CA, USA Tel. (858) , Fax. (248)

Modelling of Photovoltaic Module Using Matlab Simulink

REAL-TIME WIRELESS ECG AND ITS SIGNAL DISPLAY ON LABVIEW

Transmit filter designs for ADSL modems

E40M. Instrumentation Amps and Noise. M. Horowitz, J. Plummer, R. Howe 1

Reliability and availability analysis for robot subsystem in automotive assembly plant: a case study

Differential Amplifier : input. resistance. Differential amplifiers are widely used in engineering instrumentation

Instrumentation Amplifiers

Transcription:

IOP Conference Series: Materials Science and Engineering PAPER OPEN ACCESS III Lead ECG Pulse Measurement Sensor To cite this article: S K Thangaraju and K Munisamy 2015 IOP Conf. Ser.: Mater. Sci. Eng. 88 012047 View the article online for updates and enhancements. Related content - An OTA-C filter for ECG acquisition systems with highly linear range and less passband attenuation Duan Jihai, Lan Chuang, Xu Weilin et al. - Microprocessor-based simulator of surface ECG signals A E Martínez, E Rossi and L Nicola Siri - Intracavity power addition with a closeended composite four-mirror cavity Lei Ming, Gong Ma-Li, Liu Qiang et al. This content was downloaded from IP address 46.3.205.71 on 04/12/2017 at 13:36

IOP Conf. Series: Materials Science and Engineering 88 (2015) 012047 doi:10.1088/1757-899x/88/1/012047 1 III Lead ECG Pulse Measurement Sensor S K Thangaraju, K Munisamy 1 College of Engineering, Universiti Tenaga Nasional, Jalan IKRAM-UNITEN, 43009, Kajang, Malaysia Email: savithry@uniten.edu.my Abstract - Heart rate sensing is very important. Method of measuring heart pulse by using an electrocardiogram (ECG) technique is described. Electrocardiogram is a measurement of the potential difference (the electrical pulse) generated by a cardiac tissue, mainly the heart. This paper also reports the development of a three lead ECG hardware system that would be the basis of developing a more cost efficient, portable and easy to use ECG machine. Einthoven s Three Lead method [1] is used for ECG signal extraction. Using amplifiers such as the instrumentation amplifier AD620BN and the conventional operational amplifier Ua741 that would be used to amplify the ECG signal extracted develop this system. The signal would then be filtered from noise using Butterworth filter techniques to obtain optimum output. Also a right leg guard was implemented as a safety feature to this system. Simulation was carried out for development of the system using P-spice Program. 1. INTRODUCTION Monitoring of cardiovascular pulse is widely used in health care, sport training; sleep studies and psycho-physiological (polygraph) examinations. Various contact measurement methods have been developed to estimate a subject s cardiovascular pulse. The golden standard for pulse measurement is Electro-Cardio- Graphy (ECG). ECG signal is the measurement of the potential difference of pulse waves that are generated from heart cells called the pacemaker cells. ECG recording requires the use of a signal amplifier and at least three electrodes. ECG readings can be used to monitor the conditions of heart (detect diseases such as Parkinson disease, Myocarditis, etc). There are many type of ECG machine in the market today such as 3 Lead, 12 Lead and 15 Lead ECG machine. However, these machine are expensive, not portable and not user friendly. These ECG machine cost from a minimum price of USD 620 (RM 2200) and are big and bulky therefore not portable. Moreover the 12 lead ECG system usually requires the patient to remove his or her clothes to enable 6 electrode placement on the chest and 3 electrode placement on the limbs, making it difficult an uncomfortable for patients. Hence, this thesis elaborates on the development of three lead ECG pulse measurement system for Electrocardiogram (ECG) signal extraction. The system develop also produces an ECG signal of the same quality however smaller therefore the hardware is more portable than a standard 3 lead ECG machine available in the market today. The Einthoven s 3 Lead Methods is used for ECG signal acquisition and the hardware designed comprises of amplifiers to amplify the signal and filters to remove noise as shown in Figure 1. P-spice simulations are run on all stages of development before any hardware implementation. 1 To whom any correspondence should be addressed. Content from this work may be used under the terms of the Creative Commons Attribution 3.0 licence. Any further distribution of this work must maintain attribution to the author(s) and the title of the work, journal citation and DOI. Published under licence by Ltd 1

IOP Conf. Series: Materials Science and Engineering 88 (2015) 012047 doi:10.1088/1757-899x/88/1/012047 2 2. METHOD 2.1 Amplification Stage 1 Figure 2 is a circuit diagram used for the 1 st stage using an AD620BN instrumentation amplifier A 100mV sinusoidal sign was chosen to be the input voltage, Vin and fed to amplifier. The variable resistor was then adjusted slowly to provide a minimum output voltage, Vo1 of 10V. The value of the variable resistor for a gain 100 is calculated as below [1]: RV = (+R2)/(A1-1) Where and R2 are the internal resistance of the in amp Assuming = R2 = 24.7k And choosing A1 = 100 Rv = 500 The output results are as follows The gain A1 = Vo1 / Vin = 10.78 V / 100.0mV = 107.8 which is approximate to the minimum desired gain of A1 desired = 100 2.2 Filter Stage 1 This filter was built using the Sallen Key architecture method[2] in order to have Butterworth 4 th order response. In order to achieve the 4 th order response, two 2 nd order low pass filters were cascaded together. The cut off frequency was chosen to be 0.05 Hz as it the minimum frequency of the ECG signal. To design this filter, considerations on cut off frequency, gain and quality were taken into account. The transfer function of a 2 nd order high pass filter is described as below, Vo/Vin = 1/[1-fc 2 /f 2-2jfc/f] The gain, A f1 for the filter is described as, A f1 = (Vo/Vin) = 1/ [(1 fc 2 /f 2 ) 2 + 2(fc2/f2)] Equation above can further be simplified in term of resistance of R3 and R4, A f1 = 1 + (R4/R3) The cut off frequency F c1 can be related as per equation below, F c1 = 1 / [ 2π (*R2*C1*C2)] The quality, Q of the filter is, Q = (*R2*C1*C2) / [*C1 + R2*C1 + *C2* (1 A f1 )] Thus, the calculated value for 4 th Order High Pass Filter parameters are shown in Table 1. 2

IOP Conf. Series: Materials Science and Engineering 88 (2015) 012047 doi:10.1088/1757-899x/88/1/012047 3 2.3 Amplification Stage 2 For this stage, an active amplification filter was designed to have a gain of 10 and a cut off frequency of 0.05Hz. the filter was designed using a UA741 operational amplifier. The 2 nd Stage Amplifier gain is estimated based on the correlations describe in equations below[2]. f 3dB = 1/ 2 π R 1 C With gain calculation, A2 = R 2 /R 1 Thus, at f 3dB = 0.05 Hz, the calculated gain is, A2 = 20 2.4 Filtering Stage 2 This filter was built using the Sallen Key architecture method[2] in order to have Butterworth 4 th order response. In order to achieve the 4 th order response, two 2 nd order low pass filters were cascaded together. To design this filter, considerations on cut off frequency, gain and quality were taken into account. The transfer function of a 2 nd order low pass filter is described as below, Vo/Vin = 1/[1-fc 2 /f 2-2jfc/f] The gain, A f1 for the filter is described as, A f1 = (Vo/Vin) = 1/ [(1 fc 2 /f 2 ) 2 + 2(fc2/f2)] Equation above can further be simplified in term of resistance of R3 and R4, A f1 = 1 + (R4/R3) The cut off frequency F c1 can be related as per equation below, F c1 = 1 / [ 2π (*R2*C1*C2)] The quality, Q of the filter is, Q = (*R2*C1*C2) / [*C1 + R2*C1 + *C2* (1 A f1 )] Thus, the calculated value for 4 th Order Low Pass Filter parameters are shown in Table 2. 2.5 Right Leg Guard Placement of electrodes on the human body is an excellent path for current flow and since the ECG runs on a 15V power supply, the user must be protected by placing a right leg guard in the ECG system. The right leg guard is placed at the input terminal of the instrumentation amplifier and also connected to the right leg of the user. The buffering circuit is chosen is the right leg guard [3]. This is because it is easy to design and low cost. In case of leakage current, the right leg guard will direct the leakage current to the ground and the user would be protected from getting electrocuted. The circuit diagram that could be use s a right leg guard is shown in Figure 3. Furthermore, the right leg guard also improves the impedance of an instrumentation amplifier. This is because the right leg guard reduces capacitive losses that reduce the input impedance of the in-amp. The Right Leg Guard was also being tested using ammeter at output node which gives the reading of Iout = 0 Amp 3

IOP Conf. Series: Materials Science and Engineering 88 (2015) 012047 doi:10.1088/1757-899x/88/1/012047 4 This result was matched with the desired current output of 0 Amp. 3. RESULT AND DISCUSSION The 4 th Order ECG System was designed using the 4 th order high pass and low pass filters which was integrated with the 1 st and 2 nd stage amplifiers together with the right leg guard. The designed system was simulated by putting a sinusoidal input of 20 mv 15 Hz into the system. The system then tested with the acquired ECG signal. The output signal then observed to make sure the signal displayed from the ECG system was creating noise. Figure 4 shows the integrated circuit diagram for the 4 th Order ECG System. Figure 5 shows the output result from the oscilloscope output of the integrated 4 th Order ECG System. From the output result, we can calculate the heart rate variability in beats per minutes by using Barros and Ohnishi method[4]. They define a compose time series formed by the time difference (in seconds) between two consecutive R-waves as x = [t1, t2,..,tn] it can be written as hrv=[60/t1,60/t2,,60/tn]. The overall output gain is, A = 929.5.The III lead ECG system design could be used as basis to develop a heart beat detector for monitoring purpose. The 4th order ECG system may not be accurate but may still be used to develop a heart beat detector where the QRS complex signal is the main concern. Since the QRS complex wave can be seen clearly in the ECG signal produced by the 4th order ECG system, it can be used to calculate the heart beat rate per minute hence be used as a beat detector. The objective to develop a low cost, portable and easy to use III Lead ECG System was successfully accomplished. The 4th Order ECG System output is suitable for application concerning heartbeat detection. REFERENCES [1] J. Bhattacarya and P.P Kanjilal, Assesing determination in ECG signal, IEEE Trans. Syst. Man. Cybern. Part A, vol. 29, pp. 406-410, July 1999 [2] George Clayton and Steve Winder, Operational Amplifiers, 4 th Edition, Philadelphia, PA : W.B Saunders Company, 2000, Chapter 11 [3] Arpad Barna and Dan I. Porat, Operational Amplifiers, 2 nd Edition, Boston, MA: Little, Brown, 1989, Chapter 4 [4] Darold Wobschall Circuit Design For Electronic Instrumentation, 2 nd Edition, Armonk, NY: Futura, 1995 [5] Charles Kitchin and Lew Counts, A Designer s Guide to Instrumentation Amplifiers, Report Input ECG Signal Amplification Stage 1 AD620BN 1 st stage filtering Butterworth filter Amplification Stage 2 ua741 Right leg guard Buffer 2 nd stage filtering Butterworth filter Output ECG signal Oscilloscope Right Leg of patient Figure 1. Block Diagram of III Lead ECG Pulse Measurement Sensor. 4

IOP Conf. Series: Materials Science and Engineering 88 (2015) 012047 doi:10.1088/1757-899x/88/1/012047 5 Figure 2. AD620BN Instrumentation Amplifier Circuit Diagram Table 1: Calculated value of 4 th Order High Pass Filter Parameters Af1 Q Fc (Hz) R2 R3 C1 C2 Stage 1 3 0.5412 0.05 5000 10000 1 2 1 1 Stage 2 1 1.3065 0.05 5000 10000 0 1 1 Table 2: Calculated value of 4 th Order Low Pass Filter Parameters Af2 Q Fc (Hz) R2 R3 C1 C2 Stage 1 1 0.5412 50 1125 1125 0 1 2 Stage 2 1 1.3065 50 1125 1125 0 1 2 Figure 3. Right Leg Guard Circuit Diagram \ 5

IOP Conf. Series: Materials Science and Engineering 88 (2015) 012047 doi:10.1088/1757-899x/88/1/012047 6 Figure 4. Integrated Circuit Diagram for the 4 th Order ECG System R-R interval Figure 5. Output Result from Oscilloscope for the 4 th Order ECG System 6