Data sheet www.sbc-support.com S pulse counter with S-Bus interface The S-S-Bus coupler module is a device for the collection of S pulses. With this module the consumption data of any measurement device with a S output becomes bus capable and can be accessed by every Saia PCD or Energy Manager through the S-Bus. Main features: Up to S-S-Bus Modules on the same bus 4 S pulse inputs (S+... S4+) per S-S-Bus Module Up to 4 S devices on the same S-Bus The inputs comply with the S standard 6253-3 Integrated RS-485 termination resistor LED for bus activity indication Order number PCD7.H4SE Technical Data Protection type as DIN45 Operating voltage Un Current draw Power draw IP 4 connections IP 2 23 VAC (-2/+5%) < 2 ma < 3 W Temperature - Operation -25 C +55 C - Storage -25 C +7 C EMC / noise immunity Insulation characteristics LEDs - Surge voltage according to IEC6-4-5 on main electric circuit, 4 kv.2 / 5 μs - Surge voltage according to IEC6-4-5 at S inputs, kv.2/5 μs - Burst voltage according to IEC6-4-4 - Main electric circuit 4 kv direct - S inputs 2 kv capacitive - S-Bus connections kv capacitive - ESD according to IEC6-4-2, - Contact 8 kv, air 8 kv - 4 kv / 5 Hz test according to VDE435-6 kv.2 / 5 μs surge voltage according to IEC6-4-5 - Device protection class II - Run indication by green LED (On) - Function indication by red LED when bus active Mounting Mounting Connections On 35 mm DIN top-hat rail (EN522) any mounting position - For Pozidrive, Philips or slot-head screwdriver N - Sx, S-Bus, 23 VAC.5 2.5 mm 2
Dimensioned drawings 43 28 85 45 35 58 Display elements / settings Switch for RS-485 bus termination resistor Rotary switches for S-Bus address selection Comm LED: indicates bus activity On LED: power indicator S inputs Comply with S standard EN6253-3 Counts pulses as when R < 8 Ω Counts pulses as when R > MΩ Voltage max. (GND-S) 3 VDC Current max. ( with Ω) 6 ma Pulses low min. 3 ms Pulses high min. 3 ms Frequency max. 7 Hz Changing the S-Bus-Address Switch o 23 VAC Set new address Switch on 23 VAC Note: The address setting will only be read when the module supply (23 VAC) is switched on. 2 www.sbc-support.com PCD7.H4SE S pulse counter with S-Bus interface Datasheet
F 5 E E E Wirings Diagram D /D S-Bus, pair of wires, twisted 554 Example Addressing Address high 3 6 23 VAC max. 2 m 3 9 6 S- GND (common) 9 Address low Address low R R R R Address 5 Ω < R < 8 Ω S+ S+ S2+ S3+ S4+ GND Note: If the S-S-Bus module is used in the S-Bus as last device, then the sliding switch «RS-485 Terminate» need to be in the position «On». Technical data S-Bus Bus system S-Bus Transmission rate 24-48-96-9 2-38 4-57 6-5 2. The transmission Baud rate is automatically detected Transmission mode Data Bus length (max.) 2 m (without repeater) Response time: Write: 3 ms Read: 2 ms The communication is ready 3 s after the Power On For a description of the used Registers please look at the Register Page Data transmission Only «read/write» register instructions are recognized. Only one register can be written at a time. The device will respond «NAK» if more than register is written. Up to 2 Registers could be read at a time. The device will respond «NAK» if more than 2 registers are read. The device will not respond to any unknown query. The device has a voltage monitoring system. In case of voltage loss, registers are stored in EEPROM (transmission rate» etc.) Datasheet PCD7.H4SE S pulse counter with S-Bus interface www.sbc-support.com 3
Register R Read Write Description Unit or Value X Firmware-Version Ex: = FW. X S-Bus com. number of supported registers will give «38» 2 X S-Bus com. number of supported flags will give 3 X Baudrate BPS 4 Not used will give a 5 X Type/ASN Function will give «PCD7» 6 X Type/ASN Function will give «H4» 7 X Type/ASN Function will give «SE» 8 X Type/ASN Function will give 9 X HW Vers. Modif Ex: = HW. Not used will give a Not used will give a 2 X serial number will give the serial number 3 Not used will give a 4 X Status/Protect = no Problem = Problem with last communication request 5 X S-Bus Timeout ms 6 X S-Bus Address -99 7 Not used will give a 8 Not used will give a 9 Not used will give a 2 X X Counter S Ex: 9235= 9235/2 = 456.2 kwh 2 X X Counter S2 Ex: 9235= 9235/2 = 456.2 kwh 22 X X Counter S3 Ex: 9235= 9235/2 = 456.2 kwh 23 X X Counter S4 Ex: 9235= 9235/2 = 456.2 kwh 24 X X Impulses per unit for S Ex: 2 = 2 Imp/kWh 25 X X Impulses per unit for S2 Ex: 2 = 2 Imp/kWh 26 X X Impulses per unit for S3 Ex: 2 = 2 Imp/kWh 27 X X Impulses per unit for S4 Ex: 2 = 2 Imp/kWh 28 X X ID for S User defined identification number 29 X X ID for S2 User defined identification number 3 X X ID for S3 User defined identification number 3 X X ID for S4 User defined identification number 32 Not used will give a 33 Not used will give a 34 Not used will give a 35 Not used will give a 36 X X Transmission speed : 5 2 2: 57 6 3: 38 4 4: 9 2 5: 96 6: 48 7: 24 37 X X Auto-Baud ON : Auto-Baud detect OFF : Auto-Baud detect ON 4 www.sbc-support.com PCD7.H4SE S pulse counter with S-Bus interface Datasheet
Datasheet PCD7.H4SE S pulse counter with S-Bus interface www.sbc-support.com 5