B84143G/Q*R/S176. Date. Function. Please send back to EPCOS MAG PEMC or to your EPCOS sales representative

Similar documents
2 line filters for converters and power electronics

3 line sine wave EMC output filters for converters and power electronics

Surge arrester. 2-electrode arrester B88069X3433B251 V87A-A600XP1

EMC filters. Date: November 2012

Power line chokes. 3.4 µh / 1 MHz, 25 A, +110 C. Ordering code: B82116B2828A010. Date: Version: 01

PPD AB PD / PPD AB PM

Power Quality Solutions

ERU chokes. ERU 20, helically wound. Date: February 2016

PPD AB PD / PPD AB PM

Film Capacitors Power Factor Correction

Film Capacitors AC Capacitors

Surge arrester. 2-electrode arrester B88069X9761B201 H25-E70X

Surge Arrester. 3-Electrode-Arrester. T83-A230X B88069X8910B502 Date: Version: Issue 03. Series/Type: Ordering code:

Current-compensated ring core double chokes 250 V AC, mh, A, +70 C / +80 C

Data and signal line chokes

Power line chokes. Current-compensated frame core double chokes 300 V AC, A, mh, +40 C. Series/Type: B82733F/V Date: May 2015

B88069X1630T602 A80-C90XSMD PPD AB PD / PPD AB PM

Film Capacitors Power Factor Correction

SMT Push-Pull Transformers

Film Capacitors AC Capacitors

SMT inductors. SIMID series, SIMID 0603-C. Date: July 2016

Film Capacitors Power Factor Correction

Transformers. DC/DC converters E 6.3. Series/Type: B78304B*A003 Date: October 2012

Filter for 10 Mbit data lines with HEMP-Protection according to MIL-STD

Film Capacitors Power Factor Correction

B88069X3651T902 T20-A230XSMDN PPD AB PD / PPD AB PM

Current-compensated ring core double chokes 250 V AC, mh, A, +40 C / +50 C / +60 C

B3404 B39232-B3404-U410 April 08,

Film Capacitors AC Capacitors

Surge arrester. 2-electrode arrester B88069X1620T602 A80-A230XSMD

Power line chokes. Current-compensated ring core triple chokes 440/250 V AC, 12 A, 0.35 mh. Series/Type: B82745S6123N002 Date: July 2012

2 line filters SIFI F for normal insertion loss

Film Capacitors AC Capacitors

The following products presented in this data sheet are being withdrawn.

R880 B39431R 880H210 February 04,

Inductors. VHF chokes. Date: June 2012

Power line chokes. Current-compensated U core double chokes 300 V AC, A, mh, +40 C. Series/Type: B82730U/G Date: July 2012

Data and signal line chokes

B4402 B39781B4402P810 June 13,

B8831 B39242B8831P810 August 18,

Current-compensated frame core double chokes 250 V AC, A, mh, +40 C

SMT power inductors. Size (mm) Date: June 2012

Power line chokes. Current-compensated ring core double chokes 250 V AC, A, 1 82 mh. Series/Type: B82724A/J Date: July 2012

SMT power inductors. Size (mm) Date: June 2012

Film Capacitors Power Factor Correction

Switching spark gap. SSG with lead wires B88069X3440S102

Inductors. VHF chokes B82131, B82132, B82133, B Date: June 2012

B9522 B39182B9522P810 December, 12,

SMT inductors. SIMID series, SIMID 1812-A. Date: October 2012

SMT Inductors. Z-transponder coils, size 7.7 x 7.4 x 2.65 mm. Ordering code: Date: Version: 01

SMT current sense transformers. EE 5.0 core. Series/Type: B82801B Date: December 2012

B5235 B39141B5235Z810 Sep 23,

Surge arrester. 3-electrode arrester B88069X9701T702 T30-A250XFSMD

SMT Current Sense Transformers

SMT power inductors. Size 12.5 x 12.5 x 8.5 mm B82477D4 MAG IN PD

PPD AB PD / PPD AB PM

B8018 B39182B8018P810 February 25,

B5139 B39262B5139U410 June 18,

SAW Components. SAW RF filter for base stations. RF360 Europe GmbH. A Qualcomm TDK Joint Venture CDMA 450. Date: Mar 3, 2016 Version: 2.

Ferrites and accessories

SMT power inductors. Size (mm) Date: June 2012

SAW Components. SAW RF filter for base stations. RF360 Europe GmbH. A Qualcomm TDK Joint Venture. Band 29 downlink. Date: Mar 03, 2015 Version: 2.

SMT power inductors. Size 12.5 x 12.5 x 8.5 mm B82477R4 MAG IN PD

Inductors. RF chokes, LBC+ series B82144B2 SZ MAG PD IN/T

EMC filters. 3-line filters for converters and power electronics. Date: May 2012

SMT gate drive transformer

B9898 B39272B9898P810 May 15,

B7943 B39262B7943P810 November 7,

SAW Components. SAW RF filter for base stations. RF360 Europe GmbH. A Qualcomm TDK Joint Venture. Band 3 uplink. Date: Jul 14, 2015 Version: 2.

B82462G2*

SMT Power Inductors. ERU 20, helically wound B82559*A020

Inductors. RF chokes, LBC series. Date: June 2012

SAW Components. SAW IF filter for base stations. RF360 Europe GmbH. A Qualcomm TDK Joint Venture. Date: Mar 21, 2016 Version: 2.3

B9513 B39202B9513L310 May 27,

Inductors. RF chokes, LBC series. Date: June 2012

SMT inductors. SIMID series, SIMID 2220-A. Date: October 2012

SMT inductors. SIMID series, SIMID 1210-T. Date: October 2012

B3520 B39162B3520U410 February 22,

LTE Band 17 (lower 700MHz band, blocks B and C) B8566 B39741B8566P810 February 06,

B8313 B39162B8313P810 February 12,

SAW Components. SAW filter. Automotive telematics. B3519 B39162B3519U410 May 08, Series/type: Ordering code: Date: Version:

Power line chokes. Current-compensated D core double chokes 250 V AC, mh, A, +40 C. Series/Type: B82731M/H Date: December 2016

Inductors. VHF chokes B82114 MAG IN PD

SMT inductors SIMID series

B3725 B39871B3725U410 May 16,

B8094 B39212B8094P810 April 03,

B3710 B39431B3710U410 December 17,

Power line chokes. Current-compensated frame core double chokes 250 V AC, A, mh, +40 C. Series/Type: B82733F Date: March 2011

SAW Components. SAW RF filter for base stations. RF360 Europe GmbH. A Qualcomm TDK Joint Venture TETRA. Date: Aug 24, 2015 Version: 2.

B1653 B39122-B1653-B510 December 18,

B4401 B39941B4401P810 June 13,

B3913 B39162B3913U410 January 31,

SAW Components. SAW RF filter for base stations. RF360 Europe GmbH. A Qualcomm TDK Joint Venture R-GSM. Date: Dec 23, 2015 Version: 2.

Filters for shielded rooms

B82471B*

Data and signal line chokes

B8810 B39172B8810P810 February 6,

Inductors. 3D transponder coils Size (mm) Series/Type: B82453C*A Date: June 2017

B9474 B39162B9474P810 October 19,

Film Capacitors AC Capacitors

Transcription:

Datasheet 3-line LCL-filters 305/530 V, 50/60 Hz, 801140 A, 50 C Ordering code: Date: 2015-12-15 Version: 07 Customer release Company Date Name Function Signature Please send back to EPCOS MAG MC or to your EPCOS sales representative EPCOS AG 2015. Reproduction, publication and dissemination of this publication, enclosures hereto and the information contained therein without EPCOS prior express consent is prohibited. EPCOS AG is a TDK Group Company Page 1 of 23

Typical circuit diagram B84143G0008R176, B84143G0016R176, B84143G0030R176 L1/3 L 46 / L1 L2 L3 L1 L2 L3 r s t Line C1...C3 R1...R3 Load B84143G0043R176, B84143G0058R176 L1/3 L 46 / L 79 / L1 L2 L3 L1 L2 L3 r s t Line C1...C3 R1...R3 Load -07-7659 Page 2 of 23

B84143G0086R176 L1 L2 L3 L1/3 L4/6 L1 L2 L3 r s t 10% choke module Line C1...C3 R1...R3 harmonic filter Load B84143G0145R176 L1 L2 L3 L1/3 L7/9 L4/6 L1 L2 L3 r s t 10% choke module Line C1...C3 R1...R3 harmonic filter Load B84143G0210S176, B84143G0300S176 L1 L2 L3 L1/3 L7/9 L4/6 L1 L2 L3 r s t 10% choke module Line C1...C3 R1...R3 harmonic filter C4...C6 R4...R6 Load -07-7659 Page 3 of 23

B84143G0410S176 L1 L2 L3 L1/3 L4/6 L1 L2 L3 r s t L7...L9 C4 C5 C6 10% choke module Line 3% choke module C1...C3 R1...R3 Load capacitor module B84143G0560S176 L1 L2 L3 L1/3 L4/6 L1 L2 L3 r s t L7...L9 10% choke module Line 3% choke module C1...C3 R1...R3 Load capacitor module -07-7659 Page 4 of 23

B84143G1140S176 L1 L2 L3 L1/3 L4/6 L1 L2 L3 r s t L 10...L12 L 79 / L1 L2 L3 3% choke module C1...C3 R1...R3 Line capacitor module 10% choke module Load Technical data and measuring conditions Rated voltage U R [L / L L] 305/530 V AC (50/60 Hz) Test voltage line to line for 2 s U test 2280 V DC Test voltage line to case for 2 s U test 3000 V DC Rated temperature T R 50 C Climatic category (IEC 60068-1: 1992) 25/100/21 Degree of protection (IEC 60529: 2013) IP 00 Degree of protection (IEC 60529: 2013) in combination with optional cover B84143Q*R176 IP 20-07-7659 Page 5 of 23

Characteristics and ordering codes I R Terminal cross section 3) Power R typ Approx. weight Ordering code Converter losses 1) type CIMR- Approvals 2) A mm 2 W mω kg 8 4 75 268 9 B84143G0008R176 Dx4A0005xxx D D D 16 4 140 98 18 B84143G0016R176 Dx4A0010xxx D D D 30 10 165 38 28 B84143G0030R176 Dx4A0020xxx D D D 43 16 240 26 37 B84143G0043R176 Dx4A0030xxx D D D 58 35 260 17 64 B84143G0058R176 Dx4A0040xxx D D D Harmonic filter 10%-choke 86 50 300 10 20 55 B84143G0086R176 Dx4A0060xxx D D D 145 70 515 6 30 69 B84143G0145R176 Dx4A0100xxx D D D 210 busbar 665 3 39 98 B84143G0210S176 Dx4A0130xxx D D D 300 busbar 855 2.3 42 149 B84143G0300S176 Dx4A0185xxx D D D 3%- choke 10%- choke Capacitor module 410 busbar 1398 1.3 45 163 12 B84143G0410S176 Dx4A0270xxx D D D 560 busbar 1970 1.25 55 185 25 B84143G0560S176 Dx4A0370xxx D D D 1140 busbar 4015 0.64 115 2 x185 50 B84143G1140S176 Dx4A0630xxx D D D 1) Power losses at nominal current and 20 C winding temperature with harmonics 2) = approval granted P = pending D = designed with reference to - = none 3) 2.5 mm² terminal cross section for D1000 voltage detection IEC 60939 UL 1283 CSA C22.2 No.8 Ordering codes for optional covers Ordering code cover Material Suitable for filter Weight kg B84143Q0008R176 inc plated sheet metal B84143G0008R176 1.5 B84143Q0016R176 inc plated sheet metal B84143G0016R176, B84143G0030R176 2.5 B84143Q0043R176 inc plated sheet metal B84143G0043R176, B84143G0058R176 3.7 Covers for filter B84143G0086R176 up to B84143G1140S176 not available. -07-7659 Page 6 of 23

Dimensional drawings B84143G0008R176 B84143G0016R176-07-7659 Page 7 of 23

B84143G0030R176 B84143G0043R176-07-7659 Page 8 of 23

B84143G0058R176-07-7659 Page 9 of 23

B84143G0086R176 Harmonic filter 10%-choke -07-7659 Page 10 of 23

B84143G0145R176 Harmonic filter 10%-choke -07-7659 Page 11 of 23

B84143G0210S176 Harmonic filter 10%-choke -07-7659 Page 12 of 23

B84143G0300S176 Harmonic filter 10%-choke -07-7659 Page 13 of 23

B84143G0410S176 3%-choke Capacitor box -07-7659 Page 14 of 23

10%-choke -07-7659 Page 15 of 23

B84143G0560S176 3%-choke Capacitor box -07-7659 Page 16 of 23

10%-choke -07-7659 Page 17 of 23

B84143G1140S176 3%-choke Capacitor box -07-7659 Page 18 of 23

10%-choke -07-7659 Page 19 of 23

3-line LCL-filters Dimensional drawings for optional covers B84143Q0008R176 B84143Q0016R176-07-7659 Page 20 of 23

3-line LCL-filters B84143Q0043R176 Mounting and convection space convection space mounting direction keyholes on top side mandatory convection space with and without cover keyholes on top side illustration with optional cover -07-7659 Page 21 of 23

convection space for floor mounted design mounting direction for floor mounted design convection space for wall mounted design mounting direction for wall mounted design -07-7659 Page 22 of 23

Cautions and warnings Please note the advices in our data book EMC Filters (latest edition); attention should be paid to the chapter General safety notes. It shall be ensured that only qualified persons (electricity specialists) are engaged on work such as planning, assembly, installation, operation, repair and maintenance. They must be provided with the corresponding documentation. Danger of electric shock. filters contain components that store an electric charge. Dangerous voltages can continue to exist at the filter terminals for longer than five minutes even after the power has been switched off. The protective earth connections shall be the first to be made when the filter is installed and the last to be disconnected. Depending on the magnitude of the leakage currents, the particular specifications for making the protective earth connection must be observed. Impermissible overloading of the filter, such as with circuits able to cause resonances, impermissible voltages at higher frequencies etc. can lead to bodily injury and death as well as cause substantial material damages (e.g. destruction of the filter housing). Filters must be protected in the application against impermissible exceeding of the rated currents by overcurrent protective devices. In case of leakage currents > 3.5 ma you shall mount the conductor stationary with the required cross section before beginning of operation and save it against disconnecting. For leakage currents I L a) 10 ma the conductor must have a KU value b) of 4.5; for leakage currents I LK > 10 ma the conductor must have a KU value of 6. Output chokes and output filters must be protected in the application against impermissible exceeding of the component temperature. The converter output frequency must be within the specified range to avoid resonances and uncontrolled warming of the output chokes and output filters. a) IL = Leakage current let go b) The KU value (symbol KU) is a classification parameter of safety referred failure types designed to ensure protection against hazardous body currents and excessive heating.(din VDE 0800-1, 0800-8, 0800-9) A value of KU = 4.5 with respect to interruptions is attained: with a permanently connected protective earth connections 1.5 mm 2 with a protective earth connection 2.5 mm 2 via connectors for industrial equipment (IEC 60309 2). KU = 6 with respect to interruptions is achieved for fixed-connection lines 10 mm 2, where the type of connection and installation is conform to the specification for N conductors according to DIN VDE 0100-540. Display of ordering codes for EPCOS products The ordering code for one and the same EPCOS product can be represented differently in data sheets, data books, other publications, on the EPCOS website, or in order-related documents such as shipping notes, order confirmations and product labels. The varying representations of the ordering codes are due to different processes employed and do not affect the specifications of the respective products. Detailed information can be found on the Internet under www.epcos.com/orderingcodes Important notes The following applies to all products named in this publication: 1. Some parts of this publication contain statements about the suitability of our products for certain areas of application. These statements are based on our knowledge of typical requirements that are often placed on our products in the areas of application concerned. We nevertheless expressly point out that such statements cannot be regarded as binding statements about the suitability of our products for a particular customer application. As a rule, EPCOS is either unfamiliar with individual customer applications or less familiar with them than the customers themselves. For these reasons, it is always ultimately incumbent on the customer to check and decide whether an EPCOS product with the properties described in the product specification is suitable for use in a particular customer application. 2. We also point out that in individual cases, a malfunction of electronic components or failure before the end of their usual service life cannot be completely ruled out in the current state of the art, even if they are operated as specified. In customer applications requiring a very high level of operational safety and especially in customer applications in which the malfunction or failure of an electronic component could endanger human life or health (e.g. in accident prevention or life-saving systems), it must therefore be ensured by means of suitable design of the customer application or other action taken by the customer (e.g. installation of protective circuitry or redundancy) that no injury or damage is sustained by third parties in the event of malfunction or failure of an electronic component. 3. The warnings, cautions and product-specific notes must be observed. 4. In order to satisfy certain technical requirements, some of the products described in this publication may contain substances subject to restrictions in certain jurisdictions (e.g. because they are classed as hazardous). Useful information on this will be found in our Material Data Sheets on the Internet (www.epcos.com/material). Should you have any more detailed questions, please contact our sales offices. 5. We constantly strive to improve our products. Consequently, the products described in this publication may change from time to time. The same is true of the corresponding product specifications. Please check therefore to what extent product descriptions and specifications contained in this publication are still applicable before or when you place an order. We also reserve the right to discontinue production and delivery of products. Consequently, we cannot guarantee that all products named in this publication will always be available. The aforementioned does not apply in the case of individual agreements deviating from the foregoing for customer-specific products. 6. Unless otherwise agreed in individual contracts, all orders are subject to the current version of the General Terms of Delivery for Products and Services in the Electrical Industry published by the German Electrical and Electronics Industry Association (VEI). 7. The trade names EPCOS, Alu-, CeraDiode, CeraLink, CeraPad, CeraPlas, CSMP, CSSP, CTVS, DeltaCap, DigiSiMic, DSSP, ExoCore, FilterCap, FormFit, Leaield, MiniBlue, MiniCell, MKD, MKK, MotorCap, PCC, PhaseCap, PhaseCube, PhaseMod, PhiCap, PQSine, SIFERRIT, SIFI, SIKOREL, SilverCap, SIMDAD, SiMic, SIMID, SineFormer, SIOV, SIP5D, SIP5K, TFAP, ThermoFuse, WindCap are trademarks registered or pending in Europe and in other countries. Further information will be found on the Internet at www.epcos.com/trademarks. -07-7659 Page 23 of 23