RC-19A relay - Current monitoring

Similar documents
KCS-U200 relay - Latching, 2 pole

D4-U200 relay module - 4-pole

TTBCR 200 relay - Delay-on drop-out,

AG 400 relay - Gold plated, 4 contacts

TBSBAO 400 relay - Delay-on pull-in,

UBC 200 relay - Voltage monitoring

TDB4-U200 relay - Timer, delay-on, 4 pole

MTDV4-U200 relay - Voltage monitoring,

UB 001 relay - 1 level load shedding

UTC relay - Voltage monitoring & off delay

MTDV4 relay - Voltage monitoring,

UB 200 relay - Voltage monitoring

TELAU 400 relay - Delay-on pull-in or

C relay - Safety critical, 9 contacts

BD relay - Industrial latching power

407 relay - Latching, safety critical, 40 contacts Datasheet

CK relay - safety critical, 9 contacts

CM relay - 7 contacts + 2 gold contacts

D-U200 Instantaneous relay Part of D-platform

MSV200 - Hall effect transducer

D-B Power relay, high DC breaking capacity Part of D-platform

D Instantaneous relay Part of D-platform

BM 400 relay - Mixed load, 4 contacts

MSA Hall effect transducer

MSA500 - Hall effect transducer

Portable relay tester PRT-MS1 User manual

V88 socket - Spring clamp terminal,

Mors Smitt Industrial Technology. High performance plug-in relays

Mors Smitt Industrial Technology. Industrial current & voltage sensors. Hall effect current & voltage sensors

Mors Smitt Industrial Technology

Manual Signal calibration box (SCB)

Nieaf-Smitt Maritime. Analogue panel indicators

22 Series Relays. Technical Data...1. Specifications...2. Model Number Structure - Relays...3. Model Number Selection

AC/DC Current Probe GCP-100 QUICK START GUIDE ISO-9001 CERTIFIED MANUFACTURER

Mors Smitt Industrial Technology

2 Pole CO, 8 A Plug-in 2 CO (DPDT) 1 CO (SPDT) 8/15 16/25* 250/ /400 2,000 4, /0.5/ /0.5/ (5/5) 300 (10/5)

CONTENTS. SAFETY PRECAUTIONS: Before use, read the following safety precautions

OKT OKR Series APPLICATIONS. Shipbuilding

Zelio Control Measurement Relays

PCB relay for DC voltage, polarized, monostable or bistable

Relion 605 series Self-Powered Feeder Protection REJ603 Product Guide

INSTRUCTION MANUAL (ATEX / IECEx)

DM-45 Digital Multimeter

Ordering Information. PCB Relay G6RL. Model Number Legend: Low-profile power relay with maximum switching of 10 A

PROXIMITY SENSOR TERMINOLOGY

DM-46 Instruction Manual

Power PCB Relay. To Order: Select the part number and add the desired coil voltage rating (e.g., G6B-1114-US-DC6).

2 pole (1 NO + 1 NC) 1 NO + 1 NC 2 NO + 2 NC, 3 NO + 1 NC 4 NO + 2 NC Rated current / Max. peak current Rated load AC1

20 Series Power Relays

OMRON MK-I / -S RELAY

60 Series - General purpose relays 6-10 A. Features Plug-in mount 10 A General purpose relay

3.5 mm contact pin pitch 1 Pole 12 A PCB direct or via socket

Relays & Sockets. RF1V Force Guided Relays/SF1V Relay Sockets. Certification Organization/ File Number. UL/c-UL File No.

General-purpose Relay

NGM Snubber Capacitors

Classification Contact form Enclosure rating Terminal shapes Model Minimum packing unit Standard. SPST-NO (1a) Fully sealed PCB terminal

Reyrolle Protection Devices. 7PG21 Solkor R/Rf Pilot Wire Current Differential Protection. Answers for energy

SAFETY PRECAUTIONS: Before use, read the following safety precautions

Classification Enclosure rating Contact form Contact material

38 Series - Relay interface modules A. Features /

3.5 mm contact pin pitch 1 Pole 12 A PCB direct or via socket

C20.en. Power contactors for AC and DC CT1115 and CT1130. Connect - Contact - Control

Model Number Structure

Original operating instructions Fail-safe inductive sensor GG507S / / 2013

Original operating instructions Fail-safe inductive sensor GG507S

MK-S (New Models) General-purpose Relays. New Super MK Relays. Models with Latching Lever Added to the Series. Features. Model Number Structure

Mors Smitt Group - Serving Safety

Compact size 2 Form A and 2 Form A 1 Form B 35A power relays for energy management and industrial equipment. Conditions. Mirror contact mechanisms

SLIM COMPACT SAFETY RELAY

AC / DC STROOMTANG MULTIMETER NI 30 AC / DC CLAMP MULTIMETER NI 30. Handleiding / Manual

MK-S (New Models) General-purpose Relays. New Super MK Relays. Models with Latching Lever Added to the Series. Features. Model Number Structure

48 SERIES. Relay interface modules 8 A CO forcibly guided contacts relay interface modules,15.8 mm wide Type 48.12

99 Washington Street Melrose, MA Fax TestEquipmentDepot.com # # AAC Clamp Meter. Instruction Manual

Model: &

AMM-1022 Digital Multimeter USER`S MANUAL

Relay interface modules A

Original operating instructions Fail-safe inductive sensor GM504S / / 2010

38 Series - Relay Interface Modules A

DPDT MY2N-D2 MY2IN-D2 --- (DC only) 4PDT MY4N-D2 MY4IN-D PDT (bifurcated) MY4ZN-D2 MY4ZIN-D2 --- With built-in CR

FALL-OF-POTENTIAL GROUND RESISTANCE TESTER

PCB Relay. Contact form Terminal Single-side stable Single-winding latching Double-winding latching

The Best Relaytion. Cradle Relay W Rev. B EC-JM ECOC: JM10 1. Aug. 04

Snap Action Switches Technical Guide

48 Series - Relay interface modules A. Features

G70R-SOC08 CSM_G70R-SOC08_DS_E_2_1

Characteristics 5 TeSys k contactors and reversing contactors

Instantaneous Overcurrent Relay

SPAC265-8W. AC-DC power supply module. Features. Description. Applications

MI-10kV. Technical specifications Operating instructions. Supplier:

40 Series - Miniature P.C.B. Relays A

AM-510 Commercial / Residential Multimeter. AM-510-EUR Digital Multimeter. Users Manual

LEAK CURRENT HiTESTER ST5540/ST Washington Street Melrose, MA Phone Toll Free

SERIES KC RELAY NONLATCH 3PDT, 25 AMP

Original operating instructions Fail-safe inductive sensor GM705S

ELECTRONIC SHEAR PIN MODEL ESP 1 & 2 INSTRUCTION MANUAL

Slim compact safety relay

G6C. Miniature High Capacity Relays with SPST-NO 10A and SPST-NO + SPST-NC 8A. Model Number Legend. Application Examples.

3. Contact Form A: SPST-NO

D7F. Detects Changes in Machine. Vibration. Vibration Sensor with Linear Output or Manual Setting. Ordering Information

CONVENTIONAL TYPE REED RELAY EDR0 SERIES

Transcription:

- Current monitoring Datasheet Features AC current monitoring relay Compact design 1 C/O contact Easy installation High continuous overcurrent possible Protection against short circuit and low impedance Also suitable for earth fault protection Benefits Description Current monitoring railway relay with one change-over contact. Suitable for AC currents. The input consists of a ring core saturation transformer: place the wire with current to monitor simply through the transformer. Ease of installation and high continuous overcurrent possible. Protection against short circuit and low impedance. The relay is also suitable for earthfault protection. Adjusting the pull-in current for lower values by multiple threading through the transformer. The construction of the relay and choice of materials makes the RC-19A relay suitable to withstand low and high temperatures, shock & vibrating and dry to very humid environments. No external socket necessary, the relay can be mounted on any surface via 2 screws. Application These relay series are designed for demanding rolling stock applications. The RC-19A is used in applications for current monitoring or earth fault protection. Proven reliable Long term availability Easy to maintain Low life cycle cost No maintenance Railway compliancy EN 50155 Electronic equipment used on rolling stock for railway applications IEC 60571 Electronic equipment used on railway vehicles IEC 60077 Electrical equipment for rolling stock in railway applications IEC 60947 Low voltage switch gear and control gear IEC 61373 Rolling stock equipment - Shock and vibration test EN 50121 Electromagnetic compatibility for railway applications NF F 16-101/102, EN 45545-2 Fire behaviour - Railway rolling stock IEC 60529 European standard describes the protection class (IP-code) NF F 62-002 On-off contact relays and fixed connections 1

Technical specifications Functional and connection diagrams Timing diagram Relay pin correspondence I pull-in I drop-out Connection diagram 2

Technical specifications Coil characteristics Pull-in time Release time Bounce time Power consumption 3-15 ms 3-15 ms < 1 ms 100 Hz 60 Hz 50 Power [ VA ] 10 1 0,1 1 10 100 1000 Ampere-turns Type Inom (ampere-turns) Ipull-in (ampere-turns) Idrop-out (ampere-turns) RC-19A 4.8 4.8 3.1-3.8 1.9-3.4 RC-19A 14 14 9.0-11.0 3.5-5.0 RC-19A 35 35 22.5-27.5 9.0-11.0 Example: Type RC-19A 4.8 with the current wire through the relay ring (no windings): Ipull-in is between 3.1-3.8 A. After activating the relay Idrop-out is between 1.9-3.4 A Type RC-19A 4.8 with the current wire going through the relay ring 3 times (2 windings): Ipull-in is between 1.0-1.3 A. After activating the relay Idrop-out is between 0.6-1.1 A Contact characteristics Amount and type of contacts 1 C/O Maximum make current 15 A Maximum continuous current 6 A (AC1 ; IEC 60947) Maximum switching voltage 300 VDC (then max. current = 300 ma) 250 VAC (then max. current = 2.6 A) Minimum switching voltage 12 V Minimum switching current 10 ma Maximum contact resistance 15 mω Maximum switching capacity See graph page 5 Material Contact gap Contact force Ag +0.2 µm Au (gold flash is only for storage purposes) 0.3 mm > 20 cn 3

Technical specifications Electrical characteristics Dielectric strength EN 50155 IEC 60255-5 Cont-coil IEC 60077 3 kv, 50 Hz, 1 min Mechanical characteristics Mechanical life Maximum switching frequency Weight 10 x 10 6 operations Mechanical 3600 ops/h Electrical 1200 ops/h 370 g Environmental characteristics Environmental EN 50125-1 and IEC 60077-1 Vibration IEC 61373, Category I, Class B, Body mounted Shock IEC 61373, Category I, Class B, Body mounted Operating temperature -25 C...+70 C Humidity 90%, temporary permitted condensation Damp heat IEC 60068-2-30, Test method Db variant 1 Protection IEC 60529, IP40 (relay), IP20 (contacts) Fire & smoke NF F 16-101, NF F16-102, EN 45545-2 Dimensions (mm) 4

Power (W) RC-19A relay Technical specifications Switching capacity and contact life Maximum switching capacity Electrical life expectancy 1000 100 AC % of maximum switching capacity DC resistive 100 10 DC inductive DC AC resistive AC inductive 10 10 100 1000 1 0,10 1,00 10,00 100,00 Voltage (V) No of operations (x10 6 ) Step 1: Determine switching voltage out of the application. Step 2: Select the maximum switching capacity (in Watt) at this voltage in graph Maximum switching capacity. Step 3: Calculate the actual switched load (in Watt) out of the application. Step 4: Calculate the % of maximum switching capacity: Actual load Max switching capacity Step 5: Pick the life at this load out of the graph Electrical life expectancy. 5

Instructions Installation, operation & inspection Installation Before installation or working on the relay: disconnect the power supply first! Install relay and and connect wiring according to the terminal identification. Relays can be mounted tightly together to save space. Warning! - Never use silicon in the proximity of the relays. - Do not use the relay in the presense of flammable gas as the arc generated from switching could cause ignition. Operation After installation always apply the rated current to the product to check correct operation. Before actual use of relays, it is advised to switch the load several times with the contacts. The contacts will both be electrically and mechanically cleaned due to the positive wiping action. Sometimes a contact can build up increased contact resistance (< 15 mw when new). When using silver contacts one can clean the contact by switching a contact load a few times using >24 VDC & ~2 A. Increased contact resistance is not always problematic, as it depends on circuit conditions. In general a contact resistance of 1 Ω is no problem, consult Mors Smitt for more information. Condensation in the relay is possible when the coil is energised (warm) and the outside, environmental temperature is cold. This is a normal phenomenon and will not affect the function of the relay. Materials in the relay have no hygroscopic properties. Inspection Correct operation of the relay can easily be checked as the transparent cover provides good visibility of the moving contacts. If the relay does not seem to operate correctly, check for presence of the appropriate coil voltage and polarity using a suitable multimeter. If coil voltage is present, but the relay does not operate, a short circuit of the suppression diode is possible (This may be due to the coil connection having been reversed). If the relay doesn t work after inspection, replace the relay unit with a similar model. Do not attempt to open the relay cover or try to repair. Contacts are calibrated and in balance, touching can affect proper operation. Also resoldering may affect correct operation. Since 2009 relays have tamper proof seals fitted and once broken, warranty is void. Most relay defects are caused by installation faults such as overvoltage, spikes/transients, high/short current far exceeding the relay specifications. When returning the relays for investigation, please provide all information on the RMA form. Send defective relays back to the manufacturer for repair or replacement. Normal wear and tear or external causes are excluded from warranty. 6

Ordering scheme Configuration: RC-19A 4.8 1. Relay model 2. AC current This example represents a RC-19A 4.8 Description: RC-19A relay, Inom: 4.8 AAC 1. Relay model RC-19A 2. AC current 4.8 4.8 ampere-turns 14 14 ampere-turns 35 35 ampere-turns 7

Mors Smitt France SAS Tour Rosny 2, Avenue du Général de Gaulle, F - 93118 Rosny-sous-Bois Cedex, FRANCE T +33 (0)1 4812 1440, F +33 (0)1 4855 9001 E sales.msf@wabtec.com Mors Smitt Asia Ltd. 29/F., Fun Towers, 35 Hung To Road Kwun Tong, Kowloon, HONG KONG SAR T +852 2343 5555, F +852 2343 6555 E sales.msa@wabtec.com Mors Smitt B.V. Vrieslantlaan 6, 3526 AA Utrecht, NETHERLANDS T +31 (0)30 288 1311, F +31 (0)30 289 8816 E sales.msbv@wabtec.com Mors Smitt Technologies Inc. 1010 Johnson Drive, Buffalo Grove, IL 60089-6918, USA T +1 847 777 6497, F +1 847 520 2222 E salesmst@wabtec.com Mors Smitt UK Ltd. Graycar Business Park, Barton under Needwood, Burton on Trent, Staffordshire, DE13 8EN, UK T +44 (0)1283 722650 F +44 (0)1283 722651 E sales.msuk@wabtec.com RMS Mors Smitt Ltd. 6 Anzed Court, Mulgrave, VIC 3170, AUSTRALIA T +61 (0)3 8544 1200 F +61 (0)3 8544 1201 E rms@rmspl.com.au (c) Copyright 2015 All rights reserved. Nothing from this edition may be multiplied, or made public in any form or manner, either electronically, mechanically, by photocopying, recording, or in any manner, without prior written consent from Mors Smitt. This also applies to accompanying drawings and diagrams. Due to a policy of continuous development Mors Smitt reserves the right to alter the equipment specification and description outlined in this datasheet without prior notice and no part of this publication shall be deemed to be part of any contract for the equipment unless specifically referred to as an inclusion within such contract. Mors Smitt does not warrant that any of the information contained herein is complete, accurate, free from potential errors, or fit for any particular purpose. Mors Smitt does not accept any responsibility arising from any party s use of the information in this document.