Positron Emission Tomography - PET

Similar documents
PET Detectors. William W. Moses Lawrence Berkeley National Laboratory March 26, 2002

Chiara Secco. PET Performance measurements of the new LSO-Based Whole Body PET/CT. Scanner biograph 16 HI-REZ using the NEMA NU Standard.

LSO PET/CT Pico Performance Improvements with Ultra Hi-Rez Option

First Applications of the YAPPET Small Animal Scanner

PET: New Technologies & Applications, Including Oncology

PET Performance Evaluation of MADPET4: A Small Animal PET Insert for a 7-T MRI Scanner

Celesteion Time-of-Flight Technology

PET/CT Instrumentation Basics

Fundamentals of Positron Emission Tomography (PET)

Combined micropet /MR System: Performance Assessment of the Full PET Ring with Split Gradients 4.8

An innovative detector concept for hybrid 4D-PET/MRI Imaging

New Technology in Nuclear Medicine

LaBr 3 :Ce, the latest crystal for nuclear medicine

Simulation and evaluation of a cost-effective high-performance brain PET scanner.

APD Quantum Efficiency

CHAPTER 8 GENERIC PERFORMANCE MEASURES

Development of PET using 4 4 Array of Large Size Geiger-mode Avalanche Photodiode

Future directions in Nuclear Medicine Instrumentation

PET Performance Measurements for an LSO- Based Combined PET/CT Scanner Using the National Electrical Manufacturers Association NU Standard

Performance evaluation of a new highsensitivity time-of-flight clinical PET/CT system

Performance characterization of a novel thin position-sensitive avalanche photodiode-based detector for high resolution PET

William Hallet - PRIMA IV 1

Primer on molecular imaging technology

Design Studies of A High-Performance Onboard Positron Emission Tomography For Integrated Small Animal PET/CT/RT Radiation Research Systems

Monte Carlo Simulation Study of a Dual-Plate PET Camera Dedicated to Breast Cancer Imaging

Conceptual Study of Brain Dedicated PET Improving Sensitivity

Detector technology challenges for nuclear medicine and PET

Performance Assessment of Pixelated LaBr 3 Detector Modules for TOF PET

MPPC and Liquid Xenon technologies from particle physics to medical imaging

NM Module Section 2 6 th Edition Christian, Ch. 3

Designing an MR compatible Time of Flight PET Detector Floris Jansen, PhD, Chief Engineer GE Healthcare

Initial evaluation of the Indiana small animal PET scanner

Study of a Prototype VP-PET Imaging System Based on highly. Pixelated CdZnTe Detectors

2594 IEEE TRANSACTIONS ON NUCLEAR SCIENCE, VOL. 56, NO. 5, OCTOBER /$ IEEE

The Influence of Crystal Configuration and PMT on PET Time-of-Flight Resolution

A NOVEL CONCEPT FOR A POSITRON EMISSION TOMOGRAPHY SCANNER

A new operative gamma camera for Sentinel Lymph Node procedure

Attenuation Correction in Hybrid MR-BrainPET Imaging

Instructions for gg Coincidence with 22 Na. Overview of the Experiment

Journal of Radiology in press. Simultaneous PET/MR Images, acquired with a Compact MRI Compatible PET Detector in a 7 Tesla Magnet

Development of the LBNL Positron Emission Mammography Camera

Design of a High Resolution and High Sensitivity Scintillation Crystal Array with Nearly Perfect Light Collection

Performance measurements of a depth-encoding PET detector module based on positionsensitive

Focusing on high performance

Discovery ST. An Oncology System Designed For PET/CT. Revision: B Date: 30 Jan Page 1 of 47

LaBr 3 :Ce scintillation gamma camera prototype for X and gamma ray imaging

COMPUTED TOMOGRAPHY 1

Initial Certification

Currently, the spatial resolution of most dedicated smallanimal

Radionuclide Imaging MII 3073 RADIONUCLIDE IMAGING SYSTEM

Data. microcat +SPECT

Quality control of Gamma Camera. By Dr/ Ibrahim Elsayed Saad 242 NMT

... In vivo imaging in Nuclear Medicine. 1957: Anger camera (X;Y) X Y

A High-Resolution GSO-based Brain PET Camera

Investigation of low noise, low cost readout electronics for high sensitivity PET systems based on Avalanche Photodiode arrays

Time-of-flight PET with SiPM sensors on monolithic scintillation crystals Vinke, Ruud

2/14/2019. Nuclear Medicine Artifacts. Symmetric energy windows

Pitfalls and Remedies of MDCT Scanners as Quantitative Instruments

Noise Characteristics of the FORE+OSEM(DB) Reconstruction Method for the MiCES PET Scanner

arxiv: v1 [physics.med-ph] 29 Nov 2018

Performance Evaluation of SiPM Detectors for PET Imaging in the Presence of Magnetic Fields

PD233: Design of Biomedical Devices and Systems

16 Instrumentation and Data Acquisition

Recent Advances in Hybrid Molecular Imaging Systems

Investigation of Multiple Head Registration / Center of Rotation for SPECT Gamma Cameras

How Gamma Camera s Head-Tilts Affect Image Quality of a Nuclear Scintigram?

Design of a High-Resolution and High-Sensitivity Scintillation Crystal Array for PET With Nearly Complete Light Collection

Recovery and normalization of triple coincidences in PET

PET has evolved from a research tool for studying

The PennPET Explorer Scanner for Total Body Applications

2010 Philips BrightView XCT SPECT/CT

Introduction. Chapter 16 Diagnostic Radiology. Primary radiological image. Primary radiological image

Photomultiplier Tube

UCLA UCLA Previously Published Works

764 IEEE TRANSACTIONS ON NUCLEAR SCIENCE, VOL. 51, NO. 3, JUNE 2004

Design, Calibration, and Evaluation of Depth-of- Interaction-Capable PET Detector Modules

Attenuation length in strip scintillators. Jonathan Button, William McGrew, Y.-W. Lui, D. H. Youngblood

Image Quality Assessment of Pixellated Systems

Usefulness of noise adaptive non-linear Gaussian filter in FDG-PET study

Study of Silicon Photomultipliers for Positron Emission Tomography (PET) Application

Cross-Strip Multiplexed Electro-Optical Coupled Scintillation Detector for Integrated PET/MRI

Positron Emission Tomography

Time-of-flight PET with SiPM sensors on monolithic scintillation crystals Vinke, Ruud

Scintillation Counters

Assessment of Image Quality of a PET/CT scanner for a Standarized Image situation Using a NEMA Body Phantom

Lightburst Digital Detector

VISTA-CT USER MANUAL. GE Healthcare 3000 N. Grandview Blvd Waukesha, WI USA

Gamma Ray Spectroscopy with NaI(Tl) and HPGe Detectors

PET is a noninvasive, diagnostic imaging technique that

4 Time walk correction for TOF-PET detectors based on a monolithic scintillation crystal coupled to a photosensor array

GS Introduction to Medical Physics IV Laboratory 5 Gamma Camera Characteristics

Robert Pagnanelli BSRT(R)(N), CNMT, NCT, FASNC Chief Technologist, Nuclear Imaging Duke University Medical Center. Thursday September 8, 2011

IEEE TRANSACTIONS ON NUCLEAR SCIENCE, VOL. 52, NO. 3, JUNE Investigation of the Block Effect on Spatial Resolution in PET Detectors

12/21/2016. Siemens Medical Systems Research Agreement Philips Healthcare Research Agreement AAN and ASN Committees

Design of a Static Full-Ring Multi-Pinhole Collimator for Brain SPECT

Radionuclide Imaging MII Single Photon Emission Computed Tomography (SPECT)

SOLID state photodiode and avalanche photodiode scintillation

Multimodal Co-registration Using the Quantum GX, G8 PET/CT and IVIS Spectrum Imaging Systems

Study of the performance of a novel 1 mm resolution dual-panel PET camera design dedicated to breast cancer imaging using Monte Carlo simulation

A PET detector module using FPGA-only MVT digitizers

Transcription:

Positron Emission Tomography - PET Positron Emission Tomography Positron Emission Tomography (PET): Coincidence detection of annihilation radiation from positron-emitting isotopes followed by tomographic reconstruction of 3-D activity distribution. Some unique features of PET: Use of electronic collimation instead of lead collimation. High detection efficiency Uniform resolution Accurate attenuation correction Absolute Quantification Use of short-lived biologically active radio-pharmaceuticals: 11 C-glucose 13 N-ammonia 15 O-water 18 FDG 18 FDOPA M. Dahlbom M284B Winter 2016 1

Coincidence Detection Amp. Amp. PHA 511 kev? 511 kev? PHA Coinc. Counter M. Dahlbom M284B Winter 2016 2

PET Gantry ECAT HR+ PET Gantry M. Dahlbom M284B Winter 2016 3

Siemens Hi-Rez / Biograph 16 Hi-Rez Bernard Bendriem, Ph.D. Vice-President, R&D March 19, 2004 LSO 13x13 elements/block 4x4x20mm 2 detector elements Coincidence Detection M. Dahlbom M284B Winter 2016 4

Coincidence Detection # of possible LORs: N = number of detectors N = LOR NN ( -1) 2 Spatial Resolution The spatial resolution in PET is primarily determined by: Detector size Physics of positron decay System geometry Detector material M. Dahlbom M284B Winter 2016 5

Spatial Resolution For a source placed at the midpoint between two scintillation detectors with a width w d, the geometric line spread function has a triangular shape with a FWHM of w d /2. w d w d w FWHM= d 2 FWHM = w d /2 Spatial Resolution -Tangential For sources located between the midpoint and the detector surface the LSF will have a trapezoidal shape with width varying from w d /2 (at the center) and w d at the detector surface. M. Dahlbom M284B Winter 2016 6

Spatial Resolution - Radial Transaxial Resolution or ECAT EXACT HR Axial section Radial FWHM (mm) Tangential 8 7 6 5 4 FWHM tang FWHM rad R=0 3 2 1 0 0 5 10 15 20 R (cm) Small Lesion Detection: A Phantom Study Bernard Bendriem, Ph.D. Vice-President, R&D March 19, 2004 All spheres contain the same activity concentration 17 13 10 22 37 28 Profile (10 mm) Recovery (%) 100 50 17 22 28 37 13 Standard 8 x 8 detector 0 10 Sphere diameter Recovery coefficients HI-REZ 13 x 13 detector M. Dahlbom M284B Winter 2016 7

Spatial Resolution Although the most energetic positrons can travel several mm before annihilating, only a few of these are emitted. The average positron energy emitted is approximately 1/3-1/2 of the maximum energy. The total path length the positrons travel is not along a straight path. Through inelastic interactions with electrons in the positrons path is deflected. The distance from the mother nucleus is therefore much shorter. Positron Range From Levin & Hoffman PMB 44, 1999 M. Dahlbom M284B Winter 2016 8

Positron Range ~65% ~50% 18 F 635 kev 124 I 1.53 & 2.14 MeV Non-colinearity ~0.3 FWHM 100 cm Ø ~ 2.5 mm FWHM 15 cm Ø ~ 0.3 mm FWHM M. Dahlbom M284B Winter 2016 9

Spatial Resolution The measured resolution (intrinsic resolution) of the system is a convolution of the various resolution components. If the different resolution components are assumed to be Gaussian in shape and are described by a FWHM then the combined resolution is the squared sum of the individual resolution components: FWHM = FWHM + FWHM + FWHM 2 2 2 total det ector positron angulation 3D Acquisition PET 2D Acquisition PET 3D Acquisition PET M. Dahlbom M284B Winter 2016 10

3D vs. 2D PET The main advantage of the 3-D acquisition in PET is an improved sensitivity of ~5-7 times the 2-D sensitivity. The drawback is that the scatter fraction increases by a factor of 3. Non-uniform axial sensitivity Higher Randoms Rates Increased Noise (offsets sensitivity gain) Dead-time problems when using slow detectors Image reconstruction is more complex More data M. Dahlbom M284B Winter 2016 11

Coincidence Detection Amp. Amp. PHA 511 kev? 511 kev? PHA Coinc. Counter Timing Resolution 160 64 ns Counts 120 80 FWHM 6 ns 40 0 0 20 40 60 80 100 120 Channel Timing spectrum showing the PHA trigger time variation for a pair of BGO detectors in coincidence. The two peaks corresponds to two separate measurements where an additional delay of 64 ns of the stop pulse for channel-to-time calibration. M. Dahlbom M284B Winter 2016 12

Coincidence Detection All coincidence detection systems have a finite time resolution BGO ~6 ns FWHM NaI ~4 ns FWHM GSO ~2 ns FWHM LSO ~0.5 ns FWHM Coincidence Detection Amp. Amp. PHA 511 kev? 511 kev? PHA Coinc. Counter M. Dahlbom M284B Winter 2016 13

Random Coincidences Because of the finite width of the logic pulses that are fed into the coincidence circuit, there is a probability for random or accidental coincidences between unrelated events. True Single Coinc. Event Random Coinc. Detector 1 Detector 2 Time τ True Coinc. Single Event Random Coincidences If N 1 and N 2 are the individual average count rates of detector 1 and 2, respectively, then it can be shown that the random coincidence rate for the pair of detectors is: N R = 2τ N 1 N 2 Where 2τ is the coincidence window (or τ is the width of the singles pulses) M. Dahlbom M284B Winter 2016 14

Event Types True Event Scattered Event Random Event Multiple Event Signal-to-Noise True Coincidences ~ Activity Good events! / ~ T S N T M. Dahlbom M284B Winter 2016 15

Signal-to-Noise Random Coincidences ~ Activity 2 Can be accurately corrected for Correction increases image noise Detector material dependent S/ N ~ T T + 2R Signal-to-Noise Scattered Coincidences ~ Activity Reduces Image Contrast Requires correction Analytical estimation Correction increases image noise S/ N ~ T T + S+ 2R M. Dahlbom M284B Winter 2016 16

Signal-to-Noise Multiple Coincidences: ~ Activity 3 Never saved Source of Dead time Improvements in PET Image Quality PET III 1975 NaI ECA T II 1976 NeuroECAT 1978 ECA T 931 1985 BGO ECA T EXACT HR+ 1994 CTI/Siemens M. Dahlbom M284B Winter 2016 17

PET Detectors Most modern PET system use a different detector technology where a large number of scintillation crystals are coupled to a smaller number of PMTs. In the block detector, a matrix of cuts are made into a solid block of scintillator material to define the detector elements. The depth of the cuts are adjusted to direct the light to the PMTs. The light produced in each crystal, will produce a unique combination of signals in the PMTs, which will allow the detector to be identified. The Technology : HiRez Bernard Bendriem, Ph.D. Vice-President, R&D March 19, 2004 Standard Detector 6.4 mm x 6.4 mm 64 crystals/block 144 blocks/scanner 9216 crystals/scanner 3.4 mm slice width 47 slices HI-REZ Detector 4.0 mm x 4.0 mm 169 crystals/block 144 blocks/scanner 24336 crystals/scanner 2 mm slice width 81 slices M. Dahlbom M284B Winter 2016 18

Scintillator Materials NaI (Tl) BGO GSO LSO LYSO LaBr 3 Density [g/ml] 3.67 7.13 6.71 7.35 7.1 5.29 1/µ [cm] 2.88 1.05 1.43 1.16 1.2 ~2 Index of Refraction 1.85 2.15 1.85 1.82 1.81 1.9 Hygroscopic Yes No No No No Yes Rugged No Yes No Yes Yes Yes Peak Emission [nm] 410 480 430 420 420 380 Decay Constant [ns] 230 300 60 40 41 25 Light Output 100 15 35 75 75 >100 Energy Resolution 7.8 20 8.9 <9 11 7.5 56 Presentation Title Goes In This Area M. Dahlbom M284B Winter 2016 19

57 Presentation Title Goes In This Area Improvements in PET Image Quality LSO ECAT HRRT CTI/Siemens M. Dahlbom M284B Winter 2016 20

Corrections in PET In most nuclear medicine procedures, the goal is to produce an image in which the gray scale or count density is directly proportional to the regional isotope concentration. In order to achieve this in PET it is necessary to apply a number of corrections: Attenuation of photons in tissue Non-uniform response of detector elements Random coincidence events Detection of scattered events Loss of counts at high count rates - dead-time Isotope decay Absolute Calibration & cross calibration with other instruments How accurate these corrections are will have a direct impact on the quantitative measurement. Attenuation Correction M. Dahlbom M284B Winter 2016 21

Attenuation Correction Attenuation Correction In PET imaging of the brain, the shape of the head can be approximated with an ellipse. The dimensions of the fitted ellipse can be estimated by first reconstructing the data without attenuation correction. Then an ellipse is drawn onto the image from which the attenuation correction can be derived. The attenuation correction is the applied to the data and the image is reconstructed again. This method can be fairly time consuming, especially on system producing a large number of transaxial slices. Atten. Corr.. = e µd M. Dahlbom M284B Winter 2016 22

Attenuation Correction 68 Ge Source Blank Scan Transmission Scan Without Image Segmentation With Image Segmentation M. Dahlbom M284B Winter 2016 23

A Early frame non-ac EM Original TX Fused TX-EM (Match) Early frame AC EM B Late frame non-ac EM Original TX Fused TX-EM (Mismatch) Late frame AC EM (before MC) C Late frame non-ac EM TX after MC Fused TX-EM (Match) Late frame AC EM (after MC) M. Dahlbom M284B Winter 2016 24

PET/CT GE Philips Siemens x 0.495 H.U. µ 70 kev x 0.406 M. Dahlbom M284B Winter 2016 25

Time-of-flight PET R R Det 2 Det 1 x R - x R + x s = v t R + x = vt 1 R x = vt 2 2x = v(t 2 t 1 ) x = cδt 2 M. Dahlbom M284B Winter 2016 26

Time-of-flight PET For ideal detectors, TOF would eliminate the need for image reconstruction, since the measurement would allow each event to be accurately positioned in space. All detectors have a finite time resolution, or uncertainty in timing. This translates to an uncertainty in positioning. BGO ~ 5 ns NaI ~ 1.5 ns CsF, LaBr 3 ~ 0.45 ns BaF 2, LSO, LYSO ~ 0.3 ns 75 cm 22.5 cm 6.7 cm 4.5 cm Time-of-flight PET Figure 1. Image elements contributing to a LOR, for conventional PET (left) and TOF PET (right). M. Dahlbom M284B Winter 2016 27

Time-of-flight PET Even with a finite time resolution, using the TOF information an improvement in signal-to-noise ratio (S/N) can be achieved: 2 D D SNR SNR = SNR Δx cδt TOF conv. conv. Time-of-Flight vs. Conventional PET Better information sent to reconstruction Truth Conventional PET Image Formation Time-of-Flight Image Formation More precise localization of annihilation event improves image quality M. Dahlbom M284B Winter 2016 28

Time-of-flight PET - 1980 s Problems with TOF in the 80 s Poor detection efficiency of available scintillators TOF Gain did not offset the poor efficiency To improve the efficiency, large detector modules were used A more significant gain in S/N could be achieved by using high resolution detectors and conventional detection methods (Phelps, Hoffman, Huang, 1982). Time-of-flight PET - 2006 Scintillators: CsF, BaF 2 LSO, LYSO - fast, high light, and dense Detectors/PMTs: 1:1 coupling 100:1 crystal encoding - spatial resolution Geometry: 2D (septa) 3D with large axial FOV - sensitivity Reconstruction: Analytic (FBP) iterative (list-mode) - system modeling Electronics: Accurate and stable M. Dahlbom M284B Winter 2016 29

Can we see TOF improvement? non TOF TOF 5 min 3 min 1 min 6-to-1 contrast; 35-cm phantom J. Karp, U of Penn Noticeable improvement with TOF with large size phantom Gemini TF - patient study Rectal carcinoma, metastases in mesentery and bilateral iliac chains 114 kg; BMI = 38.1 12 mci; 2 hr post-inj 3min/bed non-tof TOF J. Karp, U of Penn Lesion contrast (SUV) improves with TOF reconstruction M. Dahlbom M284B Winter 2016 30

ME Phelps et. al. DH Silverman et. al. M. Dahlbom M284B Winter 2016 31

DH Silverman et. al. DH Silverman et. al. M. Dahlbom M284B Winter 2016 32

Low Grade Brain Tumor MRI FDG FDOPA FLT SUV 3.0 FDOPA Uptake Patterns 2.5 2.0 1.5 1.0 0.5 0.0 Striatum Tumor Cerebellum 0 20 40 60 minutes 80 Tumor reaches maximum before striatum M. Dahlbom M284B Winter 2016 33

Integrated PET/MRI System Images courtesy Bernd Pichler Opportunities: direct and accurate registration of molecular PET signal with high resolution anatomy Anatomically guided analysis of PET data Improved quantification of PET data Good soft tissue contrast, no additional radiation dose time correlation of PET and MRI or MRS signal Interventional, therapeutic studies Dual-labeled agents ( 64 Cu, Gd) Positrons in Magnetic Field M. Dahlbom M284B Winter 2016 34

MR Compatible PET System Animal MR System Concept PET Detectors Magnet Gradient Coils RF coil Simultaneous PET/MRI Imaging Shao Y, Cherry SR, Farahani K, et al. Phys Med Biol 42: 1965-1970; 1997 56 mm ring diameter 72 2x2x25 mm LSO scintillators 200 g Rat - 18 F-FDG Brain Study M. Dahlbom M284B Winter 2016 35

Challenges in Combining PET and MR imaging PET Detectors affected by: Static magnetic field Rapidly changing gradient field Radiofrequency signals MR affected by PET detectors and electronics B. Pichler et. al., 2008 M. Dahlbom M284B Winter 2016 36

Solutions for combining PET-MR MR-Compatible PET Detector Module scintillator array optical fiber bundle PSAPD preamplifiers M. Dahlbom M284B Winter 2016 37

PMT vs. APD/SiPM PET Insert preamplifiers PSAPDs optical fibers scintillator ring M. Dahlbom M284B Winter 2016 38

MR phantom images: GE (left) and SE (right) sequences of a gadopentetate dimeglumine/h2o phantom (T1 = 250 ms) without PET insert (first row) and with PET insert unpowered (second row) and powered (third row). Catana et.al., JNM 47 (12), 2006 Catana et.al., JNM 47 (12), 2006 M. Dahlbom M284B Winter 2016 39

MR/PET brain scanner prototype (conceptual design) detector 6-detector module (32 modules) gantry patient bed head coil bed rails M. Dahlbom M284B Winter 2016 40

Test Setup n Concentric MR and PET n MR: n CP-TXRX-Head coil inner Diameter 27 cm n RF Shield id 36 cm n PET: n 512 LSO crystals in 2 modules n FOV 3.2 cm n Imaging by phantom rotation n MR/PET phantom n 1.0 mm - 3.5 mm diameter holes n Filled with water and 1.25 g NiSO 4 / litre and about 50 MBq FDG M. Dahlbom M284B Winter 2016 41

SUPPLEMENTAL FIGURE 1 Diagram of the Biograph mmr, depicting how the PET detectors are located within the MR coils. M. Dahlbom M284B Winter 2016 42

PET-MRI Attenuation Correction M. Dahlbom M284B Winter 2016 43

FIGURE 7. mmr PET/MR (A) and Biograph PET/CT (B) fused views of whole-body 18F-fluoride scan of same patient. mmr (C) and Verio (D) T2- weighted coronal views of healthy volunteer. M. Dahlbom M284B Winter 2016 44