Ordering Information. Application Example. New General-purpose Incremental. Rotary Encoder

Similar documents
Incremental Rotary Encoder

Supply voltage Output configuration Resolution (P/R) Model 12 to 24 VDC Complementary output 100, 200, 360, 500, or 600 E6F-CWZ5G 1,000

Incremental Rotary Encoder

Incremental Rotary Encoder E6B2

NPN PNP NPN PNP NPN PNP

Absolute Rotary Encoder E6C2-A

Absolute Rotary Encoder

Power supply voltage Output configuration Output code Resolution (pulses/rotation) Connection method Model

Resolution (divisions) 256, 360, , 360, 720, 1,024 Pre-wired Model

Label Sensor. Ordering Information. Application Example E3S-CD68/CD63. Ideal for Detecting Labels on Bottles. E3S-CD68/CD63 Label Sensor

Resolution (pulses/rotation) 100, 200, 300, 360, , 720, 800 1,000, 1,024, 1,200 1,500, 1,800, 2,000 2,048, 2,500, 3, , , 360, 500

Connections Appearance Sensing method Sensing distance Operating mode Model Plug-in connector Horizontal Through-beam 30 m Light-ON

Distance-setting Photoelectric Sensor

Resolution (pulses/rotation) 100, 200, 300, 360, , 720, 800 1,000, 1,024, 1,200 1,500, 1,800, 2,000 2,048, 2,500, 3, , , 360, 500

Basic principle features

MOS FET Relay. Ordering Information. SSR for Switching Analog Signals, with an Insulation Value of 2.5 kvac between Input and Output Terminals

Inductive Proximity Sensor

Distance-setting Photoelectric Sensor

Power supply voltage Output configuration Resolution (pulses/rotation) Model 720, 800, 1,000, 1,024, 1,200, 1,500, 1,800, 2,000

TRD-J Series Incremental Encoders

Digital Panel Meter. Ordering Information. Subminiature Digital Panel Meter that Accepts DC Input. Accessories (Order Separately)

Output configuration Resolution (pulses/rotation) Model. 10, 20, 30, 40, 50, 60, 100, 200, 300, 360, 400, 500, 600 E6C2-CWZ6C (resolution) 2M

TRD-N/NH Series Incremental Encoders

E6F-CWZ5C (1000P/R) 2M

Resolution (divisions) Pre-wired Model E6F-AB3C 360P/R 2M *2 Pre-wired Connector E6F-AB3C-C 360P/R 2M *2 Model (2 m) NPN open collector BCD 360

E6F-CWZ5C (1000P/R) 2M

E3S-C. Built-in Amplifier Photoelectric Sensor. Water- and Oil-resistive Photoelectric Sensor with Metal Housing Ensuring Long Sensing Distance

TL-W. Standard Flat Inductive Proximity Sensors. Ordering Information. Front and side facing surface IP67 DC 2-wire and DC 3-wire models

E6B2-C. General-purpose Encoder with External Diameter of 40 mm. Incremental 40-mm-dia. Rotary Encoder. Ordering Information

Self-powered Counter

Rectangular Proximity Sensor

Capacitive Proximity Sensor

Solid-state Twin Timer

TRD-J Series Incremental Encoders

Tactile Switch. Ordering Information. A Wide Range of Models: 6 x 6 mm, 12 x 12 mm, Vertical, and High-force.

Built-in Amplifier Photoelectric Sensor

Built-in Amplifier Photoelectric Sensor

High-precision Optical Switch

E2F. Cylindrical Proximity Sensor in Plastic Housing. Applications. Ordering Information. Sensors. Accessories (Order Separately)

Overtravel of 3.5 mm max. Power source DC D5C-1DS0 D5C-1DP0 D5C-1DA0 AC D5C-1AS0 D5C-1AP0 D5C-1AA0 Antenna only D5C-00S0 D5C-00P0 D5C-00A0

EE-SX770/771/772/870/871/872(A/P/R)

Model Number Structure. Ordering Information. Solid-state Power OFF-delay Timer H3DE-H. Model Number Legend. List of Models

E3S-CR62/67. Ideal for detecting transparent glass and plastic containers. Transparent bottle sensor. Features

Application Examples. Features. Ultrasonic Displacement Sensor E4PA-N. Now, more advanced with a new mutual interference prevention function.

Photoelectric Sensors with Separate Digital Amplifiers (Laser-type Amplifier Units) E3C-LDA Series

Ratchet Relay. Ordering Information. Unique Ratchet Mechanism Assures Positive Alternate Transfer/Switching Operation. G4Q-jjjj

256, 360, 720, 1,024. E6C3-AN1E 256P/R 1M Voltage output Binary VDC E6C3-AN2E 256P/R 1M

Application Examples. Features. Ultrasonic Displacement Sensor E4PA-N. Now, more advanced with a new mutual interference prevention function.

E3Z-LS. Distance-settable Photoelectric Sensor. Ordering Information. Sensors. Accessories (Order Separately)

Ordering Information. Rotary Encoder (Incremental/Absolute) E6C3. Incremental Rotary Encoders. An Encoder That Offers Durability and Convenience

Ordering Information. Ratchet Relay G4Q. Model Number Legend

Z4D-F. LED-type Micro Displacement Sensor with Many Features in a Compact Body. Micro Displacement Sensor. Ordering Information.

Express Delivery. Axial. Connection

E3X-NL. Employs OMRON's Unique Free Angle Optics Technology for Detecting Minute Differences in Glossiness. Optical Fiber Glossy Object Sensor

Digital Counter. DIN 72 x 72 mm Counters with Easy-to-use Functions

EE-SPX303/403. Ordering Information. Large Slot Width (13 mm) Not Influenced by External Light. H Easy adjustment and optical axis monitoring

Product Discontinuation Notices

E3S-CL. Distance setting photoelectric sensor in metal housing. Features

Sensing method Through-beam Retroreflective Diffuse reflective Convergent-beam Appearance Side-view Flat Side-view Flat Side-view

Non-Ferrous-Metal-Detecting Proximity Sensor (Separate Amplifier Type)

Encoders. Up-to-date price list: FREE Technical Support:

CompoBus/D-type Digital Controller

Light-ON/Dark-ON* Approx. 3.5 g EE-SY671

TL-W5MD1 2M *1 *3 TL-W5MD2 2M

10 to 30 VDC (10% max. permissable ripple peak-to-peak)

Diameter ø50mm Shaft type Absolute Multi-turn Rotary Encoder

Tactile Switch. Ordering Information. A Wide Range of Models: 6 6 mm, mm, Side-operated, High-force, and Gold-plated.

Ordering Information. Stepping Relay Unit G9B. Model Number Legend

E2B PROXIMITY SENSORS

Cylindrical type proximity sensor

Operating mode. distance. 7 m Light ON Dark ON (selectable) 2 m [100 mm] (See note 1.) 100 mm (wide view)

Phase-sequence Phase-loss Relay

Safety Relay Unit. OFF-delay time

Inductive Proximity Sensor

LED Displacement Sensor

Material: Weight: Bearing Life: Shaft Speed: Starting Torque: Mass Moment of Inertia: Shaft Loads:

D7F. Detects Changes in Machine. Vibration. Vibration Sensor with Linear Output or Manual Setting. Ordering Information

Diameter Ø50mm Shaft Type Magnetic Multi-Turn Absolute Rotary Encoder MGAM50S B F PN 24

Solid-state Timer. Operation/resetting system Time-limit contact Time ranges Model

Solid-state Timer H3DE

Photoelectric Sensor

QR12. Output. A = Line Driver B = Line Driver ABZ/ Open Collector UVW C = Sin/Cos/ Line Driver UVW D = Sin/Cos/Open Collector UVW

Type Sealing Poles Contacts Rated voltage Model 5PST-NO, SPST-NC 24 VDC *1

Type Sealing Poles Contacts Rated voltage Model Standard Flux-tight 4 poles 3PST-NO, SPST-NC 24 VDC G7SA-3A1B. Type LED indicator Poles Rated voltage

Rotary Measurement Technology Incremental Encoders

Lexium integrated drives

JR12 Jam Nut Mount Optical Encoder

Electrical data Units FVS 58, FHS 58. Operating voltage (PELV) [VDC] Current consumption at 24 VDC [ma] 85

Self-Powered Counters H7ET

Ordering Information. Latching Relay MMK. Available Models. Models Conforming to Auxiliary Power Relay Specifications

EE-SPX613. Ordering Information. An Ideal Photomicrosensor for Detecting Liquid Levels in Transparent Pipes

847H. Description. Features. Specifications

EE-SPY311/411/312/412

Digital Panel Meter K3TE. Model Number Structure. Model Number Legend. Easy-to-use, Low-cost Digital Panel Meter that Accepts DC Input K3TE

Silicon Wafer Mapping Sensor F3M-S. Ordering Information. Application Examples. Allows Simultaneous Mapping of up to 25 Silicon Wafers

EE-SPY311/411/312/412

Rotary Encoders Catalog Vol.5.0

Sensing method Through-beam Retroreflective Diffuse reflective Convergent-beam Appearance Side-view Flat Side-view Flat Side-view

The World of Motion Control

Laser Displacement Sensor

Transcription:

Rotary Encoder New General-purpose Incremental Rotary Encoder A wide operating voltage range of 5 to 24 VDC (open collector model). Resolution of 2,000 pulses/revolution in 40-mm housing. can be adjusted with ease using the origin indicating function. A large load of 29.4 N (3 kgf) in the radial direction and 19.6 N (2 kgf) in the thrust direction is permitted. The load short-circuit and reversed connection protecting circuit assures highly reliable operation. A line driver output model is available. (Cable extends up to 100 m.) Ordering Information Supply voltage Output configuration Resolution (P/R) Model 5 to 24 VDC NPN open collector output 10/20/30/40/50/60/100/200/300/360/400/500/ -CWZ6C 600/1,000/1,200/1,500/1,800/2,000 12 to 24 VDC PNP open collector output 100/200/360/500/600/1,000/1,200/1,500/1,800/ -CWZ5B 2,000 5 to 12 VDC Voltage output 10/20/30/40/50/60/100/200/300/360/400/500/ 0/30/ 0/50/60/ 00/ 00/300/360/ 00/500/ -CWZ3E 5 VDC ine driver output 600/1,000/1,200/1,500/1,800/2,000 -CWZ1X Note: 1. Pre-wired models are also available. 2. When ordering, specify the resolution together with the model number. Accessories (Order Separately) Coupling Flange Name Mounting Bracket Model E69-C06B (attachment) E69-C68B E69-C610B E69-C06M E69-FBA E69-FBA02 E69-2 (provided with the E69-FBA02) Application Example 1

Filling Control Filling material Valve opening Rotary Encoder Counter Specifications Ratings/Characteristics Electrical Item -CWZ6C -CWZ5B -CWZ3E -CWZ1X Power supply voltage 5 VDC 5% to 12 VDC 10% to 5 VDC 5% to 5 VDC ±5% 24 VDC +15% 24 VDC +15% 12 VDC +10% Current consumption (see note 3) Resolution 10/20/30/40/50/60/100/ 200/300/360/400/500/6 00/ 1,000/1,200/1,500/1,80 0/2,000 P/R 80 ma max. 100 ma max. 160 ma max. 100/200/360/500/600/ 1,000/2,000 P/R 10/20/30/40/50/60/100/200/300/360/400/500/600/ 1,000/1,200/1,500/1,800/2,000 P/R Output phases A, B, and Z (reversible) A, A, B, B, Z, Z Output configuration Open collector Open collector Voltage ine driver (see note 2) Output capacity 30 VDC max. 35 ma max. 20 ma max. AM26S31 equivalent 35 ma max. Residual voltage: Residual voltage: Output current: Residual voltage: 0.4 V max. 0.4 V max. igh level = I 0.4 V max. o = 20 ma ow level = I s = 20 ma Output voltage: igh level = V o = 2.5 V min. ow level = V s = 0.5 V max. Max. response frequency (see note 1) 100 kz 50 kz 100 kz Phase difference on 90 ±45 between A and B (1/4T±1/8T) output Rise and fall times of output Insulation resistance Dielectric strength Note: 1 s max. (control output voltage: 5 V; load resistance: 1 k ; cord length: 0.5 m) 1 s max. (cord length: 2 m; I sink : 10 ma max.) 100 M min. (at 500 VDC) between carry parts and case 500 VAC, 50/60 z for 1 min between carry parts and case 1 s max. (cord length: 0.5 m; I sink : 10 ma max.) 0.1 s max. (cord length: 0.5 m; I o : 20 ma; I s : 20 ma) 1. The maximum electrical response revolution is determined by the resolution and maximum response frequency as follows: Maximum electrical response frequency (rpm) = Maximum response frequency/resolution x 60 This means that the Rotary Encoder will not operate electrically if its revolution exceeds the maximum electrical response revolution. 2. The line driver output is a data transmission circuit compatible with the RS-422A and long-distance transmission is possible with a twisted-pair cable. 3. An inrush current of approximately 9 A will flow for approximately 0.3 ms when the power is turned ON. 2

Mechanical Shaft loading Moment of inertia Starting torque Max. permissible revolution Item -CWZ6C -CWZ5B -CWZ3E -CWZ1X Vibration resistance Shock resistance Radial: 29.4 N (3 kgf) Thrust: 19.6 N (2 kgf) 1 x 10 6 kg m 2 ( 10 gf cm 2) max.; 3 x 10 7 kg m 2 (3 gf cm 2 ) max. at 600 P/R max. 980 N m (10 gf cm) max. 6,000 rpm Destruction: 10 to 500 z, 150 m/s 2 (15G) or 2-mm double amplitude for 11 min 3 times each in X, Y, and Z directions Destruction: 1,000 m/s 2 (100G) 3 times each in X, Y, and Z directions Weight Approx. 100 g max. (cord length: 0.5 m) Environmental Item -CWZ6C -CWZ5B -CWZ3E -CWZ1X Ambient temperature Ambient humidity Degree of protection Operating: 10 C to 70 C (with no icing) Storage: 25 C to 85 C (with no icing) Operating: 35% to 85% (with no condensation) IEC60529 IP50 (The Rotary Encoder is not watertight or oil resistive.) Operation Output Circuits -CWZ6C -CWZ5B Main circuit 3.3 NPN transistor 35 ma max. 30 VDC max. Brown Black, white, orange Output signal (Black: phase A, white: phase B, orange: phase Z) (Shielded) 5 VDC 5% to 24 VDC +15% 0 V Ground Main circuit 3.3 PNP transistor 35 ma max. Brown Black, white, orange (Shielded) 12 VDC 10% to 24 VDC +15% Output signal (Black: phase A, white: phase B, orange: phase Z) 0 V Ground -CWZ3E -CWZ1X Main circuit 2 k 3.3 NPN transistor 20 ma max. Brown Black, white, orange Output signal (Black: phase A, white: phase B, orange: phase Z) (Shielded) 5 VDC 5% to 12 VDC +10% 0 V Ground Main circuit AM26S31 or equivalent 20 ma max. Brown Black, white, orange Non-reversed output (Black: phase A, white: Black, white, orange (with red stripes) (Shielded) 5 VDC±5% phase B, orange: phase Z) Reversed output (Black/red: phase A, white/red: phase B, orange/red: phase Z) 0 V Ground 3

Timing Charts Open Collector Output -CWZ6C -CWZ5B Direction or resolution: CW (As viewed from the end of the shaft) Direction or resolution: CCW (As viewed from the end of the shaft) T (360 ) CW T (360 ) CCW ON OFF ON OFF ON OFF 1/4T±1/8T (90 ±45 ) ON OFF ON OFF ON OFF 1/4T±1/8T (90 ±45 ) Note: is 1/4±1/8T faster than phase B. The ONs in the above timing chart mean that the output transistor is ON and the OFFs mean that the output transistor is OFF. Note: is 1/4±1/8T slower than phase B. Voltage Output -CWZ3E Direction or resolution: CW (As viewed from the end of the shaft) Direction or resolution: CCW (As viewed from the end of the shaft) T (360 ) CW T (360 ) CCW 1/4T±1/8T (90 ±45 ) 1/4T±1/8T (90 ±45 ) Note: is 1/4±1/8T faster than phase B. Note: is 1/4±1/8T slower than phase B. ine Driver Output -CWZ1X Direction or resolution: CW (As viewed from the end of the shaft) Direction or resolution: CCW (As viewed from the end of the shaft) T (360 ) CW T (360 ) CCW 1/4T±1/8T (90 ±45 ) 1/4T±1/8T (90 ±45 ) Note: The line driver output circuit is an RS-422A data transmission circuit consisting of two balanced output lines. The relationship between the two output lines is on an equal status. This means that if the level of the signal on a line is, the level of the signal on the other line is. The noise-resistive line driver output circuit assures high-speed data transmission. 4

Input to More than One Counter from Encoder (with Voltage Output) Use the following formula to obtain the number of counters to be connected to a single Rotary Encoder. Number of counters (N) = R1 (E V) V x R2 E: Voltage supplied to Rotary Encoder V: Minimum input voltage of the counter R2: Output resistance of the Rotary Encoder R1: Input resistance of the counter R2 + V 0 V + E Encoder output stage R1 Counter R1 Counter Connectable number: N Origin Indication It is easy to adjust the position of phase Z with the origin indication function. The following illustration (on the left-hand side) shows the relationship between phase Z and the origin. Set cut face D to the origin as shown in the illustration (on the right-hand side). Origin of phase Z 120 120 Origin Cut face D 30±0.2 dia. Output Protection Circuit The (open collector model with voltage output) incorporates a circuit preventing the from damage due to a short-circuited load and reversed connection. 5

Dimensions Note: All units are in millimeters unless otherwise indicated. Origin of phase Z Three, M3 holes Depth: 7 mm 15 5 39 10 120 120 6 0 0.012 dia. 40 dia. 1 Coupling E69-C06B (Included) 2.8 22 5.5 (11) 5.5 (16.4) 2.8 Four, M3 hexagon socket heat setscrews 30±0.2 dia. 20 0 0.021 dia. E69-C68B (Sold Separately, Different Diameter ) 24.8 Brass bush 6.8 6.8 Four, M4 hexagon socket heat 3.5 3.5 setscrews 7.5 5-dia. 5-conductor insulated round PVC shielded cord (18 x 0.12 dia.); standard length of 50 cm (8 conductors for the line driver) 8 E69-C610B (Sold Separately, Different Diameter) 25.6 7.1 7.1 Four, 4 hexagon Brass bush socket heat setscrews 3.6 3.6 68 dia. 15 dia. 68 dia. 88 dia. 19 dia. 68 dia. 108 dia. 22 dia. Note: The coupling is made of glass-reinforced PBT. E69-C06M (Sold Separately, Different Diameter) 19.1 2.4 2.4 Four, M3 hexagon socket head setscrews 68 dia. 19.1 dia. Note: The coupling is made of super super duralumin. Flange (Sold Separately) E69-FBA 42 33±0.2 Four, R3 33±0.15 42 E69-FBA02 Four, 3.3-dia. holes Three, 3.5-dia. holes with 30 dia. 6.5-dia. countersinking 20.2-dia. hole 46 dia. 20.2±0.1 dia. Three, 3.5-dia. holes with 6.5-dia. countersinking The flange is made of SPCC. t = 3.2 The flange is made of SPCC t = 3.2 Mounting Bracket (Three Pieces as a Set) E69-2 (One Set Provided with the E69-FBA02) 2 5.5-dia. hole (18) 16 9 ÉÉ ÉÉ 120 120 58±0.2 dia. 20 dia. Panel Two, C1 8 16 3.1 +0.1 0 (5.1) 120 Three, M5 6

Installation Connection Be sure to connect the external terminals correctly or the -CWZ1X Rotary Encoder may be damaged. Color Terminal -CWZ6C/-CWZ5B/-CWZ3E Brown Power supply (+V CC ) Color Terminal Black Output phase A Brown Power supply (+V CC ) White Output phase B Black Output phase A Orange Output phase Z White Output phase B Black/red stripes Output phase A Orange Output phase Z White/red stripes Output phase B 0 V (common) Orange/red stripes Output phase Z 0 V (common) Note: Receiver: AM26S32 equivalent Note: 1. The external conductor (shield) of the shielded cord is not connected to the internal conductors nor to the case. 2. All the phases A, B, and Z are in the same circuit. 3. Connect the GND to the 0-V line or to the ground terminal. Conversion from E6B to Refer to the following table for conversion from the E6B to the. E6B Resolution: 10 to 600 P/R E6B-CWZ3C E6B-CWZ3E Resolution: 10 to 2,000 P/R -CWZ6C -CWZ3E --- -CWZ1X (line driver output) Connections with Peripheral Devices Coupling Specification Resin, standard type Resin, non-standard opening diameter Internal shaft diameter (mm) 4 (8), 13 6 (8), 15 8 (8), 19 10 (8), 22 6/8 (8), 19 6/10 (8), 22 Metal 6 (8), 19.1 10 (8), 25.4 Rotary Encoder Model E69-C04B E69-C06B E69-C08B E69-C10B E69-C68B E69-C610B E69-C06M E69-C10M, 6 mm diameter C A C C B B B C Note: A: Possible to connect directly in most cases. B: Possible to connect, but an independent power supply or pull-up resistor will be required. C: Impossible to connect. Connection Examples Connection to 7CR-CW Counter -CWZ6C White Black Features of 7CR DIN-sized (DIN 48) counter incorporating a prescale function converting the measured value to the actual value. Synchronized output and ± indication are available (± area models). Models with a general-purpose six-digit display and four-digit display are available. 0 V CP2 6 8 9 CP1 12 VDC (100 ma) 7CR-CW Brown 11 1 2 48 48 7

Connection to K3NR-NB /K3NP-NB Rotary Intelligent Signal Processor Features of K3NR/K3NP Each model incorporates a prescale function with an input range of 50 kz and the measurement accuracy is 0.006%. A variety of outputs including relay, transistor, BCD, linear, and communications outputs are available. 144.6 48 96 8

Precautions Mounting Mounting Procedure 1. Insert the shaft into the coupling. Do not secure the coupling and shaft with screws at this stage. 2. Secure the Rotary Encoder. Refer to the table on the right for the maximum insertion length of the shaft into the coupling. Coupling E69-C06B E69-C610B E69-C06M Insertion length 5.5 mm 7.1 mm 8.5 mm 3. Secure the coupling. Coupling E69-C06B E69-C610B E69-C06M E69-C10M Tightening torque 0.25 N m {2.5 kgf cm} 0.44 N m {4.5 kgf cm} 0.7 N m {7 kgf cm} 3.5 N m {36 kgf cm} 4. Connect the power and I/O lines. Turn OFF the Rotary Encoder when connecting the lines. 5. Turn ON the Rotary Encoder and check the output. Installation Be careful not to spray water or oil onto the Rotary Encoder The Rotary Encoder consists of high-precision components. andle it with utmost care and do not drop the Rotary Encoder, otherwise malfunctioning may result. When the Rotary Encoder is used in reversing operation, pay utmost attention to the mounting direction of the Rotary Encoder and the directions of increment and decrement rotation. To match phase Z of the Rotary Encoder and the origin of the device to be connected to the Rotary Encoder, conform the phase Z output when connecting the device. Do not impose an excessive load on the shaft if the shaft is connected to a gear. If the Rotary Encoder is mounted with screws, the tightening torque must be approximately 0.49 N m (5kgf cm). Refer to the following illustrations when using a standard coupling. Eccentricity tolerance Declination tolerance Displacement tolerance in the shaft direction 0.15 mm max. 2 max. 0.05 mm max. If the eccentricity or declination value exceeds the tolerance, an excessive load imposed on the shaft may damage the Rotary Encoder or shorten the life of the Rotary Encoder. 9

Mounting When connecting the shaft of the Rotary Encoder with a chain timing belt or gear, connect the chain timing belt or gear with the shaft via the bearing and coupling as shown in the following illustration. Chain Coupling sprocket Bearing Rotary Encoder Do not hit the shaft or coupling with a hammer when inserting the shaft into the coupling. No shock must be applied to the shaft or coupling. When connecting or disconnecting the coupling, do not bend, press, or pull the coupling excessively. Bearing ife The following graph shows the life expectancy values (theoretical values) of the bearings with the radial and thrust loads imposed on the bearings. ife (x 10 9 revolutions) Ws: 2.5 kgf Ws: 3.0 kgf Ws: 4.0 kgf Wr: Radial load Ws: Thrust load Wr Ws: 2.0 kgf Encoder Ws Radial load Wr (kgf) Shaft Wiring If the Rotary Encoder is mounted in a panel, do not pull the cord with more than a force of 29.4 N (3 kgf). Mounting plate Cord Rotary Encoder 29.4 N (3 kgf) max. Do not pull the cord of the rotary Encoder after the Rotary Encoder is mounted to a panel. Do not apply any shock to the hollow shaft or the body. Connections When extending the cord, select the kind of cord with care, taking the response frequency into consideration. The longer the cord is, the more the residual voltage increases due to the resistance of the cord and the capacitance between the wires. As a result, the waveform will be distorted. OMRON recommends models with a line driver output if the cord needs to be extended. To reduce inductive noise, the cord must be laid the shortest distance, especially when the signal is input to an IC. Insert a surge absorber between the power supply terminals if there is any surge. To reduce noise, the total cord length must be as short as possible. Incorrect pulses may be generated when the Rotary Encoder is turned ON or OFF. Do not use the connected device for 0.1 s after the Rotary Encoder is turned ON and for 0.1 s before the Rotary Encoder is turned OFF. Cord Extension The rise time of each output waveform will increase when the cord is extended. This will affect the phase difference characteristics of phases A and B. The rise time varies with the resistance of the cord, the kind of cord, and the length of the cord. The residual output voltage will increase according to the length of the cord. E6C2-CWZ6C (µs) Output rise time t Cord length (m) Measurement example Power supply voltage: 5 VDC oad resistance: 1 kω (Residual output voltage was measured at a load current of 35 ma.) Cord: Dedicated cord Preventing Miscounting If the operation of the Rotary Encoder is stopped near a signal rising or falling edge, incorrect pulses may be generated, in which case the Rotary Encoder will miscount. Use an incrementdecrement counter to prevent miscounting. Extension of ine Driver Output Use twisted-pair cable to extend the line driver cord. Recommended cable: Tachii Densen s TKVVBS4P-02A Use an RS-422A receiver. The twisted-pair wires shown in the following illustration are suitable for RS-422A signal transmission. Normal mode noise can be eliminated by twisting the wires because the generated electrical forces on the lines cancel each other. E E E E Ouput residual voltage Vol (V) Twisted-pair wires Check that the is supplied with 5 VDC when a line driver output is used. There will be an approximately 1 V voltage drop if the cable length is 100 m. 10

Others Input to More than One Counter from Rotary Encoder (with Voltage Output) Use the following formula to obtain the number of counters to be connected to a single Rotary Encoder. Number of counters (N)= R1(E V) V R2 Encoder output stage Counter Counter Connectable number: N E: Voltage supplied to Rotary Encoder V: Minimum input voltage of the counter R1: Input resistance of the Rotary Encoder R2: Output resistance of the Rotary Encoder 11

The product has been produced at OMRON Ayabe which obtained ISO9001-approval for its quality system and ISO14001-approval for its environmental management system from international certification bodies. A DIMENSIONS SOWN ARE IN MIIMETERS. To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527. Cat. No. Q085-E1-1C OMRON Corporation Industrial Automation Company In the interest of product improvement, specifications are subject to change without notice. Industrial Sensors Division Sensing Devices and Components Division.Q. 28th Fl., Crystal Tower Bldg., 1-2-27, Shiromi, Chuo-ku, Osaka 540-6028 Japan Tel: (81)6-6949-6012/Fax: (81)6-6949-6021 Printed in Japan 0100-0.3M (1092) 12