DESIGN AND ANALYSIS OF ELIMINATION OF HARMONICS USING WIND ENERGY CONVERSION SYSTEMS

Similar documents
Peteris Spels, ABB Inc., WMEA, November 18, 2011 HARMONICS. ABB Group December 14, 2011 Slide 1

Three Phase PFC and Harmonic Mitigation Using Buck Boost Converter Topology

Analysis of Harmonic Distortion in Non-linear Loads

P2 Power Solutions Pvt. Ltd. P2 Power Magnetics. Quality Power within your Reach. An ISO 9001:2008 Company

22.0 Harmonics in Industrial Power Systems

Voltage Regulated Five Level Inverter Fed Wind Energy Conversion System using PMSG

Harmonics Reduction in a Wind Energy Conversion System with a Permanent Magnet Synchronous Generator

Simulation of Three Phase Cascaded H Bridge Inverter for Power Conditioning Using Solar Photovoltaic System

Design and Development of MPPT for Wind Electrical Power System under Variable Speed Generation Using Fuzzy Logic

Modeling and Analysis of Common-Mode Voltages Generated in Medium Voltage PWM-CSI Drives

Improving Passive Filter Compensation Performance With Active Techniques

Understanding Harmonics

MODELLING & SIMULATION OF ACTIVE SHUNT FILTER FOR COMPENSATION OF SYSTEM HARMONICS

Harmonic Power. A VFDs.com Whitepaper Written by Ernesto Jimenez

Enhanced Performance of Multilevel Inverter Fed Induction Motor Drive

OPTIMAL DESIGN OF A SINGLE TUNED PASSIVE FILTER TO MITIGATE HARMONICS IN POWER FREQUENCY

Mitigation of Current Harmonics with Combined p-q and Id-IqControl Strategies for Fuzzy Controller Based 3Phase 4Wire Shunt Active Filter

Power Quality Analysis in Power System with Non Linear Load

HARMONICS THE BASICS H A R M O N I C M I T I G A T I O N A N D D I S P L A C E M E N T P O W E R F A C T O R C O R R E C T I O N

DESIGN AND DEVELOPMENT OF ACTIVE POWER FILTER FOR HARMONIC MINIMIZATION USING SYNCHRONOUS REFERENCE FRAME (SRF)

Harmonics Reduction using 4-Leg Shunt Active Power Filters

Analysis of Advanced Techniques to Eliminate Harmonics in AC Drives

MODELLING AND SIMULATION OF DIODE CLAMP MULTILEVEL INVERTER FED THREE PHASE INDUCTION MOTOR FOR CMV ANALYSIS USING FILTER

Design and Simulation of Passive Filter

Voltage and Current Waveforms Enhancement using Harmonic Filters

A SPWM CONTROLLED THREE-PHASE UPS FOR NONLINEAR LOADS

Harmonics and Their Impact on Power Quality. Wayne Walcott Application Engineering Manager June, 2017

POWER FACTOR CORRECTION AND HARMONIC CURRENT REDUCTION IN DUAL FEEDBACK PWM CONTROLLED AC/DC DRIVES.

New Direct Torque Control of DFIG under Balanced and Unbalanced Grid Voltage

A Novel Harmonics-Free Fuzzy Logic based Controller Design for Switched Reluctance Motor Drive

Design and Simulation of PFC Circuit for AC/DC Converter Based on PWM Boost Regulator

Power Quality enhancement of a distribution line with DSTATCOM

INSTANTANEOUS POWER CONTROL OF D-STATCOM FOR ENHANCEMENT OF THE STEADY-STATE PERFORMANCE

Improvement of Power Quality Using Hybrid Active Power Filter in Three- Phase Three- Wire System Applied to Induction Drive

Thyristorised Automatic Power Factor

Reduction of Power Electronic Devices with a New Basic Unit for a Cascaded Multilevel Inverter fed Induction Motor

International Journal of Advance Engineering and Research Development ANALYSIS AND MITIGATION OF HARMONICS IN MEDICAL FIELD

Power Factor & Harmonics

ARE HARMONICS STILL A PROBLEM IN DATA CENTERS? by Mohammad Al Rawashdeh, Lead Consultant, Data Center Engineering Services

ISSN Vol.03,Issue.07, August-2015, Pages:

Harmonic Analysis to Improve Power Quality

HARMONICS CAUSES AND EFFECTS

Indirect Current Control of LCL Based Shunt Active Power Filter

Literature Review for Shunt Active Power Filters

ISSN: ISO 9001:2008 Certified International Journal of Engineering Science and Innovative Technology (IJESIT) Volume 2, Issue 3, May 2013

Development of DC-AC Link Converter for Wind Generator

ISSN: X Impact factor: (Volume 3, Issue 6) Available online at Modeling and Analysis of Transformer

CHAPTER 4 HARMONICS AND POWER FACTOR

Design of SVPWM Based Inverter for Mitigation of Harmonics in Power System

Harmonic Mitigation for Variable Frequency Drives. HWEA Conference February 15, Kelvin J. Hurdle Rockwell Bus. Dev. Mgr.

Harmonic Solutions in Electrical Systems. Raed Odeh Application Specialist - Power Quality & Electrical Distribution

Harmonic Design Considerations for Wind Farms

Effects of Harmonic Distortion I

ISSN Vol.03,Issue.42 November-2014, Pages:

NJWA - Harmonics and Drives Proper System Design

p. 1 p. 6 p. 22 p. 46 p. 58

Low Pass Harmonic Filters

REDUCTION OF THD IN POWER SYSTEMS USING STATCOM

Three Phase Active Shunt Power Filter with Simple Control in PSIM Simulation

COMPARATIVE STUDY BETWEEN ACTIVE AND HYBRID POWER FILTERS FOR POWER QUALITY ENHANCEMENT

Pak. J. Biotechnol. Vol. 13 (special issue on Innovations in information Embedded and communication Systems) Pp (2016)

Bhavin Gondaliya 1st Head, Electrical Engineering Department Dr. Subhash Technical Campus, Junagadh, Gujarat (India)

Resonant Controller to Minimize THD for PWM Inverter

HARMONIC contamination, due to the increment of nonlinear

Power Quality Improvement of Distribution Network for Non-Linear Loads using Inductive Active Filtering Method Suresh Reddy D 1 Chidananda G Yajaman 2

CHAPTER 5 POWER QUALITY IMPROVEMENT BY USING POWER ACTIVE FILTERS

Sinusoidal Current Control based Shunt Active Power Filter for Current Harmonics Reduction

Voltage Sag and Swell Mitigation Using Dynamic Voltage Restore (DVR)

Enhancement of Power Quality using active power filter in a Medium-Voltage Distribution Network switching loads

VARIABLE FREQUENCY DRIVE

SINGLE PHASE THIRTY ONE LEVEL INVERTER USING EIGHT SWITCHES TOWARDS THD REDUCTION

Design of Shunt Active Power Filter by using An Advanced Current Control Strategy

Synchronous Reference Frame Theory For Nonlinear Loads using Mat-lab Simulink

SINGLE PHASE BRIDGELESS PFC FOR PI CONTROLLED THREE PHASE INDUCTION MOTOR DRIVE

A Novel H Bridge based Active inductor as DC link Reactor for ASD Systems

Emicon Engineering Consultants L.L.C.

Development of Multilevel Inverters for Control Applications

PRUDENT PRACTICES TO IMPROVE POWER FACTOR AND REDUCE POWER LOSS.

INTERLINE UNIFIED POWER QUALITY CONDITIONER: DESIGN AND SIMULATION

Active Harmonic Filter (AF3)

Application of Fuzzy Logic Controller in Shunt Active Power Filter

Determination of EMI of PWM fed Three Phase Induction Motor. Ankur Srivastava

Performance Analysis of Three Phase Cascaded H-Bridge Multi Level Inverter for Voltage Sag and Voltage Swell Conditions

3/29/2012 MAIN TOPICS DISCUSSED ELECTRICAL SYSTEMS AND ELECTRIC ENERGY MANAGEMENT SECTION K ELECTRIC RATES POWER COMPUTATION FORMULAS.

Handling System Harmonic Propagation in a Diesel-Electric Ship with an Active Filter

Harmonics Elimination Using Shunt Active Filter

DRIVE FRONT END HARMONIC COMPENSATOR BASED ON ACTIVE RECTIFIER WITH LCL FILTER

Multi-Pulse Rectifier Solutions for Input Harmonics Mitigation Applicable Product: F7, G7, P7 and E7

Reducing Total Harmonic Distortion with Variable Frequency Drives

A Three Phase Seven Level Inverter for Grid Connected Photovoltaic System by Employing PID Controller

Enhancement of Power Quality in Distribution System Using D-Statcom for Different Faults

Current Control Technique for Three Phase Shunt Active Power Filter by Using Adaptive Hysteresis Current Controller

A Single Phase Single Stage AC/DC Converter with High Input Power Factor and Tight Output Voltage Regulation

ATYPICAL high-power gate-turn-off (GTO) currentsource

Course ELEC Introduction to electric power and energy systems. Additional exercises with answers December reactive power compensation

Three Phase Induction Motor Drive Using Single Phase Inverter and Constant V/F method

Power Factor Corrected Zeta Converter Based Switched Mode Power Supply

Generator Advanced Concepts

A Novel Single-Stage Push Pull Electronic Ballast With High Input Power Factor

International Journal of Research Available at

Transcription:

DESIGN AND ANALYSIS OF ELIMINATION OF HARMONICS USING WIND ENERGY CONVERSION SYSTEMS Dr.S.K.PURUSHOTHAMAN Associate Professor Department of EEE Sri Venkateswara College Of Engineering And Technology, Thirupachur 631203 E-mail : sreeradhakris@gmail.com ABSTRACT In this paper we describe design and analysis of elimination of harmonics using wind energy conversion systems. Distortion of the voltage waveforms i.e. harmonics may cause overheating of neutral conductors and electrical distribution transformers, the malfunction of electronic equipment and the distortion of communication systems. Doubly Fed Induction Generator (DFIG) applied to wind energy conversion system (WECS) using variable speed operation is being used more frequently in wind turbine application. Variable speed systems have several advantages over the traditional method of operating wind turbines, such as the reduction of mechanical stress and an increase in energy capture. AC-DC converter is used to convert variable voltage from the DFIG to DC voltage, thereby producing DC power. The DC is converted back to AC that is appropriate for electrical utilizations in the grid. However, the use of converters introduces high intensity of low frequency current harmonic content into the power system. This leads to reduction in efficiency in WECS and also decreases the life span of the generator. A case study on a 9 MW wind turbine is used to explain Harmonic Mitigation in Wind Turbine Energy Conversion Systems. In this paper, harmonic voltage and current measurements performed at different points of a wind farm comprising six DFIG wind turbines are analyzed and their most important characteristics are discussed. It presents a comparative simulation study between with and without three phase harmonic filters applied to power system model connected to wind farm. Keywords: Harmonics, Wind Energy, Inverter, Voltage, Filters, Rectifiers 1 INTRODUCTION Distortion of the voltage waveforms i.e. harmonics may cause overheating of neutral conductors and electrical distribution transformers, malfunction of electronic equipment, faulty operation of protective devices, nuisance tripping of sensitive load and the distortion of communication systems. Harmonics levels are increasing in power systems due to proliferation of non linear loads like rectifiers, variable frequency drives (VFD), uninterruptible power supplies (UPS), switched mode power supplies (SMPS) in appliances, arc and induction furnaces, fluorescent lamps with electronic ballasts, etc. Field surveys indicate that the harmonics are significant in many industries as reported in. Harmonic resonance occurs in a power system when the power system s natural frequency corresponds to the frequency of a source of harmonic current. Every power system has a natural frequency which is a function of the system reactance and the amount of power factor correction (PFC) capacitors connected to the system. In the event that there is a source of excitation with a frequency near or equal to the system s natural frequency, large resonant currents can result. The capacitors themselves are not a source of natural frequency excitation current, but can have the effect of magnifying such currents. It is common for power systems that are corrected with capacitors to near unity power factor to have a natural frequency in the vicinity of 300Hz or 350Hz or the fifth or seventh harmonics. This magnification has implications in two aspects: reduced effective power factor and unreasonable indication of harmonic indices. Harmonic magnification can be reduced by relocation of PFC capacitors. 1.1 Harmonics in Electrical Systems 515

One of the biggest problems in power quality aspects is the harmonic contents in the electrical system. Generally, harmonics may be divided into two types: 1) voltage harmonics, and 2) current harmonics. Current harmonics is usually generated by harmonics contained in voltage supply and depends on the type of load such as resistive load, capacitive load, and inductive load. Both harmonics can be generated by either the source or the load side. Harmonics generated by load are caused by nonlinear operation of devices, including power converters, arc-furnaces, gas discharge lighting devices, etc. Load harmonics can cause the overheating of the magnetic cores of transformer and motors. On the other hand, source harmonics are mainly generated by power supply with non-sinusoidal voltage waveform. Voltage and current source harmonics imply power losses, Electromagnetic Interference (EMI) and pulsating torque in AC motor drives. Any periodic waveform can be shown to be the superposition of a fundamental and a set of harmonic components. By applying Fourier transformation, these components can be extracted. The frequency of each harmonic component is an integral multiple of its fundamental. There are several methods to indicate of the quantity of harmonics contents. The most widely used measure in North America is the total harmonics distortion (THD), which is defined in terms of the amplitudes of the harmonics, Hn, at frequency nw0, where Wo is frequency of the fundamental component whose amplitude of H1 and n is integer. The THD is mathematically given by 1.2 Harmonics ILL Effects loads, nuisance breaker tripping, incorrect meter functioning, failure of protection relays, increased system losses as heat, etc. 2 STANDARDS FOR HARMONICS Harmonic voltages have to be kept within acceptable limits; the limits depend on network specification, such as harmonic impedance and voltage level. IEC 61000-3-6 can be used as a guide to find these limits. Table 1 shows indicative planning levels for the normal harmonics in a power grid and the ones considered in this paper, planning levels are equal to or lower than compatibility levels. The indicative planning levels for the total harmonic distortion for MV are THDMV=6.5%. Table 1: Indicative planning levels for harmonic voltages (in percent of the fundamental voltage) for medium level voltages (<35 kv) Harmonic order h Harmonic voltage % 5 5 7 4 11 3 13 2.5 3 NEED FOR HARMONIC REDUCTION Resonance is the point where the inductive impedance of the connected object equals the capacitive impedance of the capacitors at a given frequency. The typical scenario in a grid is that resonance is most significant at the 3rd, 5th and 7th harmonic. Although the voltages are low at these harmonics the very small resistances can cause destructive currents. Figure 1 shows a nonlinear load supplied by a voltage source ES. The voltage source has an impedance XS and is connected to a transformer with leakage reactance XT. The load is equipped with a capacitor bank XC. Harmonics produce many ill effects such as: very high neutral currents in 3P-4W system, high neutral to ground voltages, over heating of neutral conductor, reduced power factor, failure of PFC capacitors, overloading of distribution transformers, distorted voltage waveforms to other 516

Fig 1 : Voltage Source And Transformer Connected To Nonlinear Load 4 WIND TURBINE MODEL The wind turbine consists of a rotor that extracts energy from the wind and converts it into mechanical power. In practice, the characteristics of a wind turbine can be represented in a simplified form of power performance coefficient (Cp ) and tip speed ratio (λ ). The Cp λ curve is usually used in industry to describe the characteristics of a wind turbine. The tip speed ratio of a wind turbine is given by: The value of the harmonic inductive reactance XLH increases in proportion with harmonic order, while the harmonic reactance XCH of the capacitor bank decreases inversely with the harmonic order. Perfect resonance occurs at XLH = XCH but even partial resonance XLH XCH can have important effects. Table 2 shows several XCH/XLH ratios in the vicinity of resonance and corresponding IC/IH and IL/IH multipliers, illustrating the danger of overheating the capacitor and primary and secondary windings of the transformer, and ultimately the importance of controlling and reducing the harmonics. Table 2: Amplification Of Current IH XCH/XLH IC/IH I IL/IH 0.7 3.33 2.33 0.9 10 9 1 >20 >20 1.1 10 11 1.3 3.33 4.33 Where: R - the turbine rotor radius in meters (m); ωr - turbine rotor speed in radians per second (rad/s); V - the wind speed in meters per second (m/s). 5 POWR SYSTEM MODEL - WIND FARM USING DFIG The WECS considered for analysis consist of a DFIG driven by a wind turbine, rotor side converter, DC to DC intermediate circuit and grid side converter. Fig.2 shows a schematic of the wind energy conversion system having DFIG and power electronic interface that will be discussed in this paper. The turbine output power is controlled in order to follow a pre-defined power-speed characteristic, named tracking characteristic. The electrical output power at the grid terminals of the wind turbine is added to the power losses and is compared with the reference power obtained from the tracking characteristic. 517

Fig.2 Power System Model In rotor side converter system, AC voltage and VAR are regulated. DC to DC intermediate circuit consists of two converters: Converter 1 (DC to AC) and Converter 2 (AC to DC). The control system of DC to DC intermediate circuit consists of DC voltage and current regulation and pitch control system. The pitch angle is regulated at zero degree by pitch angle regulator until the speed reaches desired speed of the tracking characteristic. The DC voltage output from intermediate circuit is applied to grid side converter, which consists of an Insulated Gate Bipolar Transistor (IGBT) two-level inverter, generating AC voltage at 50 Hz. The IGBT inverter uses Pulse Width Modulation (PWM) at 2000 Hz carrier frequency. A 9 MW wind farm 518

consisting of six 1.5 MW wind turbines connected to 440V distribution system through power electronic interface. The wind speed is maintained constant at 15 m/s. The reactive power produced by the wind turbine is regulated at 0 MVAR. This model is well suited for observing harmonics and control system dynamic performance over relatively short periods of times. Fig.2 shows power system model used. The harmonic filters are connected to buses B1 to B4 as shown in Fig.2. other harmonic filters i.e. 24th to B3 and 1st, 11th/13th and 24th to B4 distort the results or harmonic distortion is increased. 6 HARMONIC MITIGATION BY HARMONIC FILTERS Harmonic filters reduce distortion by diverting harmonic currents in low impedance paths. In order to achieve an acceptable distortion, several banks of filters of different types are usually connected in parallel. The total harmonic distortion (THD) can be calculated as follows: One Double-Tuned Filter to 11/13th harmonic of 100 MVAR and -One High-Pass Filter Tuned to the 24th harmonic of 100 MVAR The total MVAR rating of the filters set is then 400 MVAR. Fig.3 shows three phase harmonic filters connected to grid, which are used to improve power quality and reduce harmonic distortion. The entire harmonic filter set, 1st, 3rd, 11th/13th and 24th, are connected to bus B1 and B2. Harmonic filters 1st, 3rd and 11th/13th are connected to B3. Only harmonic filter 3rd is connected to B4. This is done because it is observed that connection of Fig.3 Three Phase Harmonic Filters 7 RESULTS AND DISCUSSIONS In this section the simulated results for the grid connection of three phase harmonic filters described above are presented. Two cases are considered to investigate the impact of harmonic filters on power grid connected with wind energy. One case (Case 1) is that harmonic filters are not connected to power grid and another case (Case 2) is taken as harmonic filters connected to AC power grid. The comparison of magnitude of voltage THD having range 0-1 is presented in Fig.5-Fig.8. Table 3 shows the effect of adding harmonic filters in terms of voltage THDs in the existing integrated wind energy power system model. The %reduction in peak value of voltage THD with harmonic filters at busbar locations B1, B2, B3 and B4 are 80%, 80.36%, 90% and -0.8% respectively. Thus reduction in THD is significant at B1, B2 and B3. Although peak value of voltage THD rises at B4, but it is clear from Fig.8 that values of voltage THD is less in Case 2 as compared to Case 1 at other times. Table 4 presents the effect of adding harmonic filters in terms of current THDs in the existing integrated wind energy power system model. The %reduction in peak value of current THD with harmonic filters at busbar locations B1, B2, B3 and B4 are 76.5%, 35.5%. 28.6% and 95.7% respectively. The peak value at B4 with harmonic filters increase or % reduction is - 0.8% because as we keep on adding harmonic filters in 519

power system starting from lowest voltage, a stage level. will come when it will cause increase in harmonic Table3: Effect Of Adding Harmonic Filters In Terms Of Voltage Thds Busbar Location / Peak Value Without Peak Value With % Reduction Voltage THD Harmonic Filters Harmonic Filters B1 0.8 0.16 80% B2 0.82 0.161 80.36% B3 1.5 0.15 90% B4 0.253 0.255-0.8% Table 4: Effect Of Adding Harmonic Filters In Terms Of Current Thds Busbar Location/ Peak Value Without Peak Value With % Reduction Current THD Harmonic Filters Harmonic Filters B1 0.98 0.23 76.5% B2 0.4 0.258 35.5% B3 0.7 0.5 28.6% B4 3.5 0.15 95.7% Fig. 5. Comparison Of Voltage THD At Bus B1 Fig. 6. Comparison Of Voltage THD At Bus B2 520

Fig. 7. Comparison of Voltage THD at Bus B3 Fig. 8. Comparison of Voltage THD at Bus B4 8. CONCLUSION AND FUTURE WORK Harmonics analysis is an essential part of the grid impact studies needed for new wind farms. That can lead to the earlier detection of potential series and parallel resonance problems. Consequently, a harmonics mitigation solution is examined in this paper. The simulated results on transients of a power system grid integrated with wind power are presented. In this paper, we attempted to compare the impact, in terms of voltage THDs and currents THDs, of adding three phase harmonic filters to wind integrated power system consisting of DFIG. Two different cases are considered examining the influence of adding harmonic filters. The results have clearly demonstrated the ability of harmonic filters to reduce transients and harmonic distortion in power system. It has been proven that with the inclusion of harmonic filters THD reduces noticeably and hence power quality improves significantly. Wind turbines in the model base on the topology of the induction generator with backto-back converters. The model comprises the wind farm from the DC-link of the wind turbine converters to the 132 kv transmission grid. Demonstrations are done showing that the model functions as required, regulating itself at the respective set points. The model is also proven to work in different park configuration. The model is used for experimenting for the development of a method that can reduce voltage harmonics in a wind farms internal electrical network using the wind turbine inverters. The development was successful and a method is produced. Basing on the theory behind series active filters the inverter control circuit is modified, by adding an additional 521

control loop for the harmonics, enabling the inverter and its control circuit to detect and counteract the harmonics. In simulations, an average of 50-60% harmonic reduction for the 5th, 7th, 11th, and 13th harmonic was achieved. There is also done a wind farm application of the harmonic reducing inverters. Different park configurations are tried out as regards to the effect on the harmonics, and the harmonic reducing inverters. Cable length from turbines to main transformer station, length from main transformer to nearest connection point onshore and number of turbines in wind farm are configurations tried out for application. The method is shown to be an effective harmonic filter in most applications. It would be very interesting to try and implement the harmonic control structure developed in this paper in a laboratory demonstration. Experiments with different grid properties, for instance with a load on the high voltage side, could be done. Also further studies should be done when the transmission cable is situated on the high voltage side. Further development on the model could be to ad a generator and a rectifier. Experiments with applying the harmonic control structure in the rectifier to try and reduce low frequency harmonics from the generator could be done. The structure itself could also be developed to give a faster response and also reduce the harmonics further or even eliminate them completely. REFERENCES [1] Birk, J., & Andresen, B. (2007). Parallelconnected converters for optimizing efficiency, reliablility and grid harmonics in a wind turbine. EPE. Aalborg. [2] Calderaro, V., Galdi, V., Piccolo, A., & Siano, P. (2007). Design and implementation of a fuzzy controller for wind generators performance optimisation. EPE. Aalborg. [3] Hansen, A. D. (2005). Generators and Power Electronics for Wind Turbines. In T. Ackermann, Wind Power in Power Systems (pp. 53-78). John Wiley. [4] Harmonic phase sequences. (n.d.). Retrieved May 12, 2008, from All About Circuits: http://www.allaboutcircuits.com/vol_2/chpt_ 10/8.html [5] Larsson, A. (2005). Practical Experience with Power Quality and Wind Power. In T. Ackermann, Wind Power in Power Systems (pp. 349-363). John Wiley & Sons, Ltd. [6] H. M. Kojabadi, L. Chang, T. Boutot, Development of a novel wind turbine simulator for wind energy conversion systems using as inverter-controlled induction motor, IEEE Transactions on Energy Conversion, vol. 19, no. 3, pp. 547-552, Sept.2004. [7] L. Mihet-Popa, F. Blaabjerg, I. Boldea, Wind turbine generator modeling and simulation where rotational speed is the controlled variable, IEEE Transactions on Industry Applications, vol. 40, no. 1, pp. 3-10, January/February 2004. [8] Francis M. Fernandez, P. S.Chandramohanan Nair,.Influence of Power Factor Compensating Capacitors on Estimation of Harmonic Distortion., 9th Int. conference on Electrical Power quality and Utilisation, Barcelona, 2007. [9] Mark Mcgranaghan Scott Peele and Dan Murray,.Solving Harmonic Resonance Problems On The Medium Voltage System., CIRED, 19th International Conference on Electricity Distribution, Vienna, 21-24 May 2007. [10] Zhang, S Tseng, K Vilathgamuwa, M. Nguyen, D., Design of a Robust Grid Interface System for PMSG-based Wind Turbine Generators. In: IEEE Transactions on Industrial Electronics, Issue 99, 2010. [11] H. Akagi, "Active Harmonic Filter," In: Proceedings of the IEEE, 2005, pp. 2128-2141. [12] J. Arrillaga and N. R. Watson, Power System Harmonics, 2nd ed. NJ:Wiley, 2003. [13] R. S. Herrera, P. Salmeron, and H. Kim, Instantaneous Reactive Power Theory Applied to Active Power Filter Compensation: Different Approaches, Assessment, and Experimental Results, In: IEEE Trans. Ind. Electron., Jan. 2008, Vol. 55, No. 1, pp. 184 196. [14] J. Rodriguez, S. Bernet, B. Wu, J. O. Pontt and S. Kouro, Multilevel Voltage-Source- Converter Topologies for Industrial Medium- Voltage Drives, In: IEEE Trans. Ind. Electron., Dec. 2007, Vol. 54, No. 6, pp. 2930 2945. 522