Research Article Digital Radiography Using Digital Detector Arrays Fulfills Critical Applications for Offshore Pipelines

Similar documents
APPLICATION OF THE DIGITAL RADIOGRAPHY IN WELD INSPECTION OF GAS AND OIL PIPELINES

Film Replacement in Radiographic Weld Inspection The New ISO Standard

A COMPARATIVE STUDY ON THE PERFORMANCE OF DIGITAL DETECTOR SYSTEMS FOR HIGH ENERGY APPLICATIONS

Essential Parameters and Conditions for Optimum Image Quality in Digital Radiology

Minimum Requirements for Digital Radiography Equipment and Measurement Procedures by Different Industries and Standard Organizations

Computed Radiography

Performance evaluation of a photon counting detector for high energy NDT applications

Digital Radiology with Photon Counting Detectors

Moving from film to digital: A study of digital x-ray benefits, challenges and best practices

Pre Conference Workshop on Advanced Digital imaging

5th Pan American Conference for NDT 2-6 October 2011, Cancun, Mexico

» There are many possible techniques for making good radiographs. » Following a defined procedure will simplify technique

PERFORMANCE CHARACTERIZATION OF AMORPHOUS SILICON DIGITAL DETECTOR ARRAYS FOR GAMMA RADIOGRAPHY

ISO INTERNATIONAL STANDARD. Non-destructive testing of welds Radiographic testing Part 1: X- and gamma-ray techniques with film

17th World Conference on Nondestructive Testing, Oct 2008, Shanghai, China

Essential Parameters for the Visibility of IQIs and Small Indications in Digital Radiography

Strategies for Film Replacement in Radiography - a comparative study -

The HOIS recommended practice for in-service computed radiography of pipes. Dr Stephen F Burch, WCNDT 2012, Durban, SA. April 2012

Digital Radiography : Flat Panel

ISO INTERNATIONAL STANDARD. Non-destructive testing of welds Radiographic testing Part 2: X- and gamma-ray techniques with digital detectors

Radiographic testing: Increased detection sensitivity using optimum source to object distance

Advanced Digital Radiography for Field NDT

Digital Radiographic Inspection replacing traditional RT and 3D RT Development

COMPUTED RADIOGRAPHY THE STATE OF THE ART

Equivalent Penetrameter Sensitivity (EPS) for Performance Evaluation of Computed Radiography Systems Muzibur Khan * and Mike Brothers

This document is a preview generated by EVS

Minimum Requirements for Digital Radiography Equipment and Measurement Procedures by Different Industries and Standard Organizations

Migrating from traditional to Digital Radiography in Aerospace

ON THE WAY TO DIGITAL RADIOGRAPHY

ISO INTERNATIONAL STANDARD. Non-destructive testing of welds Radiographic testing of fusionwelded

Preliminary Modulation Transfer Function Study on Amorphous Silicon Flat Panel System for Industrial Digital Radiography

Tomographic 3D-Radiometry for the Visualisation and Measurement of the Defects of Girth Seams

Experiences of users in Digital Radiography

NON-DESTRUCTIVE EVALUATION UTILIZING IMAGING PLATES FOR FIELD RADIOGRAPHY APPLICATIONS

The HOIS recommended practice for in-service computed radiography of pipes

Fig.2: Scanner VistaScan for image plates

ScienceDirect. Evaluation of Pipe Wall Thickness Based on Contrast Measurement using Computed Radiography (CR)

Mobile digital radiography system for nondestructive testing of large diameter pipelines

Determination of Optimum X-Ray Tube Output Parameters kv and ma for Digital Radiography Testing of Welded Tubes

UNDERSTANDING THE CHALLENGES IN THE TRANSITION FROM FILM TO DIGITAL RADIOGRAPHY IN THE NUCLEAR POWER INDUSTRY

Photon Counting and Energy Discriminating X-Ray Detectors - Benefits and Applications

DOSE REDUCTION BY USE OF DIGITAL X-RAY DETECTORS. Bernhard REDMER

Investigation of the film Kodak MX 125 in Agfa NDT S eco processing

A Modified Detectability Criterion for Conventional Radiography Simulation

NEW POSSIBILITIES OF RADIATION CONTROL OF QUALITY OF WELDED JOINTS

Dürr NDT GmbH & Co. KG Höpfigheimer Straße 22 D Bietigheim-Bissingen Germany. Contract No. BAM ZBA Dürr

PRACTICAL CONSIDERATIONS AND EFFECTS OF METALLIC SCREEN FLUORESCENCE AND BACKSCATTER CONTROL IN GAMMA COMPUTED RADIOGRAPHY

Advancements In Digital Radiography: CR, DR, and DICONDE

Dürr NDT GmbH & Co. KG Höpfigheimer Straße 22 D Bietigheim-Bissingen Germany. Contract No. BAM ZBA Dürr

Recommended Training Curriculum For Digital Radiography Personnel (Level II)

ISO INTERNATIONAL STANDARD

THE CR SPECIALISTS HD-CR CR 35 NDT

Digital Radiography for the Inspection of Small Defects

Part 3: Image quality classes

Digital Detector Array Image Quality for Various GOS Scintillators

Hardware for High Energy Applications 30 October 2009

ISO INTERNATIONAL STANDARD

Introduction To NDT. BY: Omid HEIDARY

NDT-PRO Services expands service offering

digital radiography r High-energy DT Applications lior Pick, Ron Pincu and Ofra Kleinberger over film radiog- p P This advanced

Examination of Pipe Welds by Image Plate Based Computed Radiography System

IQI-Sensitivity and Applications of Flat Panel Detectors and X-Ray Image Intensifiers A Comparison

SINCE2011 Singapore International NDT Conference & Exhibition, 3-4 November 2011

Amorphous Selenium Direct Radiography for Industrial Imaging

Phased Array UT Application For Boiler Tube Inspection in Manufacturing And In-Service Anandamurugan S 1, Siva Sankar Y 2

Improved Inspection of CRA-Clad Pipeline Girth Welds with the Use of Accessible Advanced Ultrasonic Phased-Array Technology

International Standard

Philip Sperling. Sales Science and New Materials, YXLON International GmbH, Essener Bogen 15, Hamburg, Germany.

FOCUS. Quick Industrial X-ray Testing Without Intermediate Data Carriers of Information. by V.A. Troitskiy

Real Time Linear Array Imaging. Brian Caccamise

In-service inspections for primary coolant circuit components of light water reactors Part 6: Radiographic testing

D DAVID PUBLISHING. 1. Introduction

The Application of TOFD Technique on the Large Pressure Vessel

Engineering Policy & Procedure

Australian Journal of Basic and Applied Sciences

A True Innovation in Non-Destructive Testing System FUJIFILM COMPUTED RADIOGRAPHY. Series 4 CR

Digital Radiography and its Advantages in Field NDT Inspections Today

DETERMINATION OF INHERENT AND ADDITIONAL FILTRATION IN ORDER TO ESTABLISH RADIATION QUALITIES ACCORDING TO IEC 61267

Investigation of the film FUJIFILM IX 80 in TETENAL machine processing

X-ray Imaging. PHYS Lecture. Carlos Vinhais. Departamento de Física Instituto Superior de Engenharia do Porto

Gamex Lite 3.0 Program description and operating manual

international Standard 1106/l

10/3/2012. Study Harder

Digital Radiography Systems Techniques and Performance Evaluation for Space Applications

10/26/2015. Study Harder

RADIOGRAPHIC EXAMINATION PROCEDURE

Module 4 Design for Assembly IIT BOMBAY

A TUTORIAL FOR PERFORMING A RADIOGRAPHIC EXAMINATION

DACON INSPECTION SERVICES. Computed RADIOGRAPHY

Advancements in Pipeline Girth Weld Inspection

Center for Nondestructive Evaluation 304 Wilhelm Hall Iowa State University Ames, Iowa 50010

Projection Radiography. application on stream

The field deployable digital X-Ray solution for weld inspection in O&G

Welding Inspection Non-Destructive Testing Course Reference WIS 5

Ray Detection Digital Image Quality and Influential Factors

Automated Ultrasonic Inspection for Pipeline Girth Welds

Flash-Radiography Instead of Traditional Radiography with Intermediate Carriers of Information

GB/T Translated English of Chinese Standard: GB/T

Application Report 11/15/5471 Company: Kienle Spiess

Easy Ultrasonic Phased Array Inspection of Corrosion - Resistant Alloys and Dissimilar Weld Materials

Transcription:

Hindawi Publishing Corporation Volume 2010, Article ID 894643, 7 pages doi:10.1155/2010/894643 Research Article Digital Radiography Using Digital Detector Arrays Fulfills Critical Applications for Offshore Pipelines Edson Vasques Moreira, 1, 2 JoséMaurício Barbosa Rabello, 3 Marcelo dos Santos Pereira, 4 Ricardo Tadeu Lopes, 5 and Uwe Zscherpel 6 1 Nondestructive Testing Laboratory of TenarisConfab, 475 Av. Dr. Gastão Vidigal Neto, Pindamonhangaba, 124-900, SP, Brazil 2 Universidade Estadual Paulista (UNESP)-FEG, 333 Av. Doutor Ariberto Pereira da Cunha, Guaratinguetá, 12516-410, SP, Brazil 3 Petrobras/Engenharia/SL/SEQUI/CI, Km 3 Rodovia Presidente Dutra, São José dos Campos, 12220-840, SP, Brazil 4 Department of Materials and Technology, UNESP, FEG, 333 Av. Doutor Ariberto Pereira da Cunha, Guaratinguetá, 12516-410, SP, Brazil 5 Nuclear Instrumentation Laboratory, COPPE, Universidade Federa do Rio de Janeiro, Rio de Janeiro, Brazil 6 BAM, Federal Institute for Materials Research and Testing, Radiological Methods, 87 Unter den Eichen, 12205, Berlin, Germany Correspondence should be addressed to Edson Vasques Moreira, edsonvasques@uol.com.br Received 11 November 2009; Revised 10 February 2010; Accepted 27 April 2010 Academic Editor: João Manuel R. S. Tavares Copyright 2010 Edson Vasques Moreira et al. This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. Digital radiography in the inspection of welded pipes to be installed under deep water offshore gas and oil pipelines, like a presalt in Brazil, in the paper has been investigated. The aim is to use digital radiography for nondestructive testing of welds as it is already in use in the medical, aerospace, security, automotive, and petrochemical sectors. Among the current options, the DDA (Digital Detector Array) is considered as one of the best solutions to replace industrial films, as well as to increase the sensitivity to reduce the inspection cycle time. This paper shows the results of this new technique, comparing it to radiography with industrial films systems. In this paper, 20 test specimens of longitudinal welded pipe joints, specially prepared with artificial defects like cracks, lack of fusion, lack of penetration, and porosities and slag inclusions with varying dimensions and in 06 different base metal wall thicknesses, were tested and a comparison of the techniques was made. These experiments verified the purposed rules for parameter definitions and selections to control the required digital radiographic image quality as described in the draft international standard ISO/DIS 10893-7. This draft is first standard establishing the parameters for digital radiography on weld seam of welded steel pipes for pressure purposes to be used on gas and oil pipelines. 1. Introduction Industrial radiographic films have been utilized for many years in the quality control by NDT of a variety of products; however, the use of digital radiography has recently been implemented in several sectors, for example, the medical, aerospace, security, automotive and petrochemical sectors. In addition to the technological trend it has been demonstrated that digital radiography sometimes offers a series of benefits in terms of productivity, sensitivity, environmental aspects, image treatment tools, cost reduction, security, POF improvement [1], and so forth. Among the current options, the digital detector array, DDA, Varian 2520V, 127 μm, employed in this paper is considered one of the best solutions to use online in plants that produces pieces in series and for obtaining digital images in place of films and reducing the inspection cycle time thanks to its high degree of automation [2]. Therefore, the work reported here involved the testing and evaluation of results achieved with this new technique, comparing them with those obtained by conventional film radiography. In this paper, test specimens of longitudinal welded pipes by the submerged-arc welding, process, especially prepared with artificial defects of the most varied dimensions, were tested and a comparison was made of the sensitivity of the techniques employed. After conducting several experiments to evaluate the highest contrast sensitivity using wire-type Image Quality

2 Indicator (IQI), Basic Spatial Resolution (BSR), and Signal Noise Ratio (SNR) normalized by the Basic Spatial Resolution and comparing artificial defects, the digital method showed better results and advantages compared with conventional film technique. These experiments were carried out to support the voting and the development of the first ISO document applicable to digital radiography using DDA for weld seam inspection on welded pipes for pressure, the ISO/DIS 10893-7 specification [3]. 2. Digital Radiography Digital radiography systems offer the possibility of obtaining images with much less strict exposure requirements than those of conventional film systems. Exposure imprecision normally leads to radiographs that are dark, light or show little contrast, which are easily improved and enhanced using digital techniques. Some the advantages of digital radiographic systems include: image display, reduction of X-ray doses, image processing, automated acquisition, partially or completely automated evaluation, image storage, and the retrieval is significantly reduced. The entire operation is simplified, from obtaining the image to the cycle time involved in obtaining, evaluating and storing each image with ensured traceability [4], as illustrated in Figure 2. Different to industrial films, a fully integrated environment for digital radiographic images adds even other advantages [5] to these of the DDAs, for example: productivity and sensitivity are increased resulting in fast decisions using remote access, meetings, training, Level 3 supervision, process control monitoring, and so forth. 3. Materials and Method For this investigation a Digital Detector Array, PaxScan 2520 V from Varian was used with a 25 20 cm 2 input screen of a scintillator DRZ Plus (GdO2S), and 127 μm pixel size, resulting in a Basic Spatial Resolution (SRb) of 0 μm. The data transfer to the computer via GBit Ethernet interface allows an image transfer rate of 10 frames per second in full resolution. The software Image 3500DD from YXLON was used for data acquisition, image integration, DDA calibration and data storage [6]. The image evaluation was done using the BAM Software, ISee!, see http://www.kb.bam.de/ic. Figure 3(a) shows an inside photo of the DDA and Figure 3(b) shows details of the DDA construction, which consists of a matrix of millions of light sensitive photo s direct into contact to the scintillator screen, not shown. 3.1. Materials Involved. The pipes are manufactured with laminated carbon steel plates, according to the requirements established by API 5L and ISO 3183 specifications [7, 8]. For high-strength pipes, microalloyed steels are produced with a high level of control of the fundamental parameters throughout the manufacturing process, comprising a specific set of steels whose chemical composition and other parameters are especially developed to attain high values of mechanical properties. ThesamplesofsteelAPI5L,gradeX65weremanually welded by welding process SMAW (Shielded Metal Arc Welding). The manufacturing and selection of samples was done at TenarisConfab, they contain a huge number of introduced critical artificial welding flaws such as longitudinal and transversal cracks, lack of penetration, lack of side wall fusion, and porosities and slag inclusions. 3.2. Technique. The currently applied conventional technique using industrial films of class 1, in accordance with ASTM 1815, was evaluated and compared with the digital technique using the described DDA. For these investigations a High Power X-ray tube Y.TU 225 D04: was used, with max. 225 kv and a small focus 0.4 mm with 800W and a large focus of 1 mm with max. 1.8 kw (certified according to EN 12543-2), anode angle 11, and 4 mm inherent Aluminum filter at tube exit window [9]. The setup for digital radiography is shown in Figure 4 and the source to detector distance (SDD) and the object to detector distance (ODD) were varied to change the magnification factor (a max. of 1,2 was used) in accordance with the focal size used (0,4 or 1,0 mm) and the wall thickness to be inspected. The diaphragm at the tube port was adjusted that only the length to be inspectioned was exposed by X-rays to reduce the amount of scattered radiation 3.3. Compensation Principle. In accordance with ISO/DIS 10893-7 purpose it is possible to apply the compensation principle if duplex IQI required by the mentioned standard cannot be achieved by the used detector system. A visibility increase in the contrast IQI single wire can compensate too high unsharpness values. If ISO/DIS 10893-7 requires to show, that is, the duplex wire number D12 and the contrast sensitivity wire number, W, but they are not achieved at the same time for a specific detector setup, an increased contrast sensitivity W16 but a larger unsharpness D10 provides equal detection sensitivity (compensation principle) [10, 11]. The contrast sensitivity depends for DDA on the used integration time and X-ray tube setting used for acquisition of the radiographic images. An increased exposure time or dose of the DDA allows or increase the contrast sensitivity to values higher than reachable with industrial films [3, 10]. 3.4. Magnification Technique. The pixel size of this DDA systems is large (127 μm) compared with the small grain size in the film [9]. As a result the Basic Spatial Resolution is limited to 0 μm, which corresponds to the duplex wire D9. This difficulty was circumvented by the following two possible approaches: (1) increase the Signal to Noise Ratio (SNR) in the image for higher wire sensitivity to compensate the reduced duplex wire resolution,

3 Ocean Layer of salt Pre-salt Figure 1: Pipeline in deep water. Presalt in Brazil. Meetings Video conference R&D Supervision Level 3 inspector Process control monitoring Training Welding Repairs Interpreter Level 2 inspector Outside inspector Costumers Auditors Backup Electronic comunication Remote access Laboratory Figure 2: Full integrated environment for digital radiographic image [4]. (2) increase the X-Ray geometric magnification. In these experiments the magnifications were between 1.1 to 1.2. 4. Results The basic parameters for evaluation of the image quality are the following: the normalized Signal-to-Noise Ratio (SNRn) at base material, the Basic Spatial Resolution (SRb) and the Contrast Sensitivity (CS) by the wire type IQI. Finally, the defect visibilities obtained with DDA were compared with those obtained with digitalized films. 4.1. Normalized Signal-to-Noise Ratio, SNRn. The normalized SNRn (see ASTM E 2597 for details) for the DDA system is a function of the number of integrated image frames during the exposure time. This is a basic difference to film exposures with their limited density range of 2.3 < D < 4.2 and a fixed exposure time resulting from the film sensitivity (ISO film speed) of the selected film system class and the density requirements. DDA allow varying the SNRn by the overall image integration time in the computer in a much wider range, the maximum achievable SNRn is limited only by the quality of detector calibration. In Figure 5 curves of SNRn are shown as function of the integration time in different points. The normalized SNRn measurement was made on the base material near to the wire IQI. The ROI (Region of Interest) size for calculation of SNRn was 20 55 pixels, 1100 points.

4 (a) of DDA from backside (b) Scheme of light sensitive detector matrix Figure 3: Digital Detector Array DDA. SDD DDA Varian PaxScan 2520 V ODD Sample Diaphragm Sample X-ray tube Y.TU 225-D04 DDA X-ray tube (a) (b) Figure 4: Arrangement: (a) Basic scheme, (b) Detailed view [9]. For short exposure times the SNRn is proportional to the square root of the exposure time (number of integrated frames) because of the SNRn limitation by quantum noise generated by the X-ray photons [10, 12]. With longer exposure time the noise in the calibration data limits the achievable SNRn in the integrated image. Therefore it is necessary to use at minimum a double number of frames for the detector calibration as later during the real image acquisition of the inspected samples. The dependence of SNRn and wire perceptibility at 32,3 mm steel and 225 kv, 8 ma tube settings and a geometric setup of 700 mm SDD/80 mm ODD in the central region of the sample is shown in Figure 6. The integration time was varied between 1 s and 512 s (with 1 s frame time), the gain calibration was done with 250 s integration time and 32,3 mm steel, the offset image with 500 s. 4.2. SRb and Contrast IQI. In Figures 7 and 8 the performance of digital radiography is shown in terms of contrast sensitivity (single wire IQI read-out) as function of integration time of 1, 2, 4, 8, 16 and 32 seconds. The requirements of ISO/DIS, using the compensation principle as indicated, is shown as blue line. Figure 7 shows that the minimum requirements of ISO/DIS 10893-7 can be reached with a minimum integration time of 4 s (W18, diameter 63 μm), 2 s (W17, diameter 80 μm) and 1 s (W15, diameter 0 μm) for the wall thickness of 4,9 mm to 9,7 mm [10]. In addition, the recognized single wire IQI is given for all exposure times. The single wire number W11, is recognized for SNRn values above 100, as required by ISO/DIS 108937, the maximum contrast sensitivity reachable with this calibration is W. In Figure 8 it is possible to see that the requested sensitivities were obtained with an integration time of 1 s (W, diameter 160 μm), 2 s (W12, diameter 250 μm) and 4 s (W11, diameter 320 μm) for the wall thickness of 19,2 mm, 25,3 mm or 32,3 mm, respectively [10]. For the integration time of 32 s wire sensitivities were obtained: W19 for a wall thickness of 4,9 mm and 6,4 mm, W18 for a wall thickness of 9,7 mm, W16 (wire diameter 100 μm) and W15 for a wall thickness of 19,2 mm, W

5 SNRn 450 400 350 300 250 200 150 100 50 Sample 25.3mm-ODD73mm 0 0 5 10 15 20 25 30 35 Integration time (s) Required ISO 10893-7 class B P1 P2 P3 P4 P5 P6 Figure 5: SNRn for WT 25,3 mm, image quality class B. Contrast IQI-wire type 16 15 12 11 10 9 8 Digital radiography-iso 10893-7 (base metal) 19.2mm 19.2mm ODD 125 ODD 66 25.3mm 25.3mm ODD 7 ODD 73 32.3mm ODD 155 WT-object detector distance (ODD) 1s 2s 4s Required ISO 10893-7 Focal spot 0.4mm 8s 16 s 32 s Figure 8: IQI wire sensibility 19,2 mm to 32,3 mm. 32.3mm ODD 80 SNRn Contrast IQI-wire type 600 SNR and wire perceptibility depending on exposure time 500 400 300 200 12 12 100 11 10 0 0 5 10 15 20 25 SQR exposition time ( s) 20 19 18 17 16 15 Required ISO 10893-7 Figure 6: SNRn and wire perceptibility [10]. (+2 wires) 4.9mm ODD 100 Digital radiography-iso 10893-7 (base metal) Focal spot 0.4mm 4.9mm ODD 55 (+1 wire) 6.4mm ODD 103 Using compensation principle 9.7mm ODD 108 WT-object detector distance (ODD) 1s 8s 2s 16 s 4s 32 s Required ISO 10893-7 Figure 7: IQI wire sensibility 4,9 mm to 9,7 mm. (+1 wire) 9.7mm ODD 57 for a wall thickness of 25,3 mm and W (wire diameter of 200 μm) for a wall thickness of 32,3 mm. All these sensitivities are 2 wires higher than requested by ISO/DIS 10893-7. 4.3. Defects Visibilities. In this section comparisons are made between radiographic images obtained from digitalized films and the corresponding image from digital radiography using the DDA. The critical defects shown in the welds were artificially generated during the welding process for the purpose of comparison of indications. The images shown in Figures 9 and 10 were generated with the program ISee! and were displayed in negative mode (like film). They are results of high-pass filtering using the filter Enhance Detail in ISee! [6]. This special 2D-FFT filter did not require any adjustable parameter and is optimized for optimum presentation of welds on 8 bit displays with only very weak filter artifacts [10]. At none of the shown examples the reduced total image unsharpness of the DDA system limits the visibility of fine indication details when compared to the film images. Quite contrary, the detail visibility with DDA is even improved by the limitation of high-frequency image noise as observed on the digitized film images. The minimum time indicated was the specific integration time that fulfilled the defects visibilities compared with film. Figure 9 shows a performance comparison for a base metal wall thickness of 4,9 mm: (a) digitized AGFA D4 film (b) and (c) digital radiography with 1 s and 32 s integration time. In terms of defects visibility, they are better. In this case of 4,9 mm wall thickness the requirements of ISO/DIS for a minimum SNRn > 100 for class B was fulfilled already with an integration time of 1 s and the IQI requirement was fulfilled with 4 s integration time. In Figure 10 the performance of digital radiography is compared, for a wall thickness of 25,3 mm, base metal. The DDA with 1 s (b) and 32 s (c) integration time is shown in

6 (a) 4.9 mm-cp04-film D4 (b) 4.9 mm-cp04-1 s Crack (c) 4.9 mm-cp04-32 s Figure 9: WT of 4,9 mm: (a) Film D4, DDA with (b) 1 s and (c) 32 s of integration time. (a) 25.3 mm-cp03-film D4 (b) Lack of penetration 25.3 mm-cp03-8 s (c) 25.3 mm-cp03-32 s Figure 10: WT of 25,3 mm: (a) Film D4, DDA with (b) 8 s and (c) 32 s of integration time. SQRT (exposition time/s) ( s) 100 for class B was fulfilled with an integration time of 8 s, and the IQI requirement was fulfilled with 4 s integration time, as reported previously. Time comparation between film and digital 18 16 KODAK M100 12 10 Film 5. Integration Time of DDA Versus Exposure Time of Films AGFA D4 8 6 4 ISO 10893-7 2 Digital DNV, API 5L and ISO 3183 0 4.9 6.4 9.7 19.2 WT (mm) 25.3 32.3 Figure 11: Film KODAK M100 and AGFA D4 in comparison with DDA. comparison to the AGFA D4 film (a) in terms of defects visibilities. Independent of the noise, it is possible to see better details on the digital radiographs (b) and (c) than in the film (a). In this case of 25,3 mm wall thickness, the requirement of ISO/DIS 10893-7 for a minimum SNRn > The integration time of digital radiography and the exposure time of conventional film technique using 2 different films were compared in Figure 11. The advantage of reduced inspection time of DDA compared to films is clearly shown in the complete wall thickness range tested. It is important to note that the integration times used for the digital technique are very small in comparison with the practicable exposure times used with traditional films, while fulfilling all requirements of the investigated standards. For Kodak M100 film, Class 1, for the wall thickness of 4,9 mm this variation is 7 times and for the rest of wall thickness the variation is between 22 to 40 times. For AGFA D4 film, Class 1, for the wall thickness of 4,9 mm this variation is 5 times and for the rest of wall thickness the variation is between 15 to 28 times.

7 6. Conclusions Based on the above results, it can be concluded that the direct digital radiographic technique using DDAs is more sensitive than the conventional film technique, both in terms of visible wires of the Image Quality Indicators and in the detection of small real defects in the welds []. Hence, as foreseen in the purposed ISO/DIS 10893-7, digital radiography using DDAs can be employed directly on the productionlines of oil and gas pipelines, with important advantages over the conventional technique. This digital technique therefore represents an advance in the quality of radiographic testing currently employed, in addition to its high degree of automation, which will allow for improved productivity and greater environmental friendliness. [10] E. Moreira, R. Lopes, M. Pereira, J. M. B. Rabello, U. Zscherpel, and D. Oliveira, Real application stage of DR in weld seam of pipes for gas and oil linepipes, in 10a COTeq, Conferência de Tecnologia, Salvador, Brasil, 2009. [11] U. Ewert, K. Bavendiek, J. Robbins, et al., New compensation principles for enhanced image quality in industrial radiology with digital detector arrays, Materials Evaluation, vol. 68, no. 2, pp. 163 168, 2010. [12] D. F. Oliveira, Análise da Radiografia Computadorizada em Condições de Águas Profundas, Dissertação (Mestrado em Engenharia Nuclear), COPPE Universidade Federal do Rio de Janeiro, Rio de Janeiro, Brazil, 2007. [] U. Zscherpel and K. Bavendiek, High quality radiography with digital detector arrays, in Digital Imaging VIII Conference, Foxwoods, Conn, USA, 2005. Acknowledgments The authors are indebted to the company XYLON International for carrying out the tests, as well as the staff responsible for the Post-graduation s program at the UNESP, Universidade Estadual Paulista-FEG. The authors would also like to thank TenarisConfab for its support in terms of technical and financial resources, which enabled this paper to be carried out. References [1] L. Pick and O. Kleinberger, Technical highlights of digital radiography for NDT, Materials Evaluation, vol. 67, no. 10, pp. 1111 1116, 2009. [2] E. V. Moreira, H. R. Simões, J. M. B. Rabello, J. R. De Camargo, and M. Dos Santos Pereira, Digital radiography to inspect weld seams of pipelines better sensitivity, Soldagem einspecao, vol., no. 3, pp. 227 236, 2008. [3] ISO/DIS 10893-7, Non-destructive testing of steel tubes part 7: digital radiographic testing of the weld seam of welded steel tubes for the detection of imperfections, Geneva, Switzerland, 2009. [4] A. G. Farman, C. M. Levato, D. Gane, and W. C. Scarfe, In practice: how going digital will affect the dental office, Journal of the American Dental Association, vol. 9, 2008. [5] R. Pincu and O. Kleinberger, Portable X-ray in the service of art, Materials Evaluation, vol. 68, no. 3, pp. 311 318, 2010. [6] U. Ewert, U. Zscherpel, C. Bellon, G. R. Jaenish, J. Beckmann, and M. Jechow, Flaw size dependent contrast reduction and additional unsharpness by scattered radiation in radiography film and digital detectors in comparison, in Proceedings of the 17th World Conference on Non-Destructive Testing, Shanghai, China, 2008. [7] API 5L, Specification for Line Pipe, American Petroleum Institute, Washington, DC, USA, 2007. [8] ISO 3183, Petroleum and natural gas industries steel pipes for pipeline transportation systems, Geneva, Switzerland, 2007. [9] E. Moreira, M. C. Fritz, H. R. Simoes, J. M. B. Rabello, and J. R. Camargo, Flat-panel detectors are accepted for digital radiography in place of conventional radiography in pipeline weld inspection, in Proceedings of the 4th Conferencia Panamericana de END, Buenos Aires, Argentina, 2007.