MCR-C-UI-UI-DCI MCR 3-Way Isolation Amplifier, Configurable

Similar documents
Passive Current Transducers for Sinusoidal Alternate Currents From A/0...5 A MCR-SLP-1/5-UI-0(-SW)

MCR-VAC-UI-0-DC. Voltage transducer for AC voltages. INTERFACE Data sheet _en_02. 1 Description

MCR-C-UI-UI-DCI. Extract from the online catalog. Order No.:

MINI MCR-SL-UI-f(-SP)

MCR-T-UI(/NC) MCR-T-UI-E(/NC)

QUINT-PS-24DC/24DC/10

MINI MCR-SL-UI-I-LP-NC

MINI-PS AC/2X15DC/1

onlinecomponents.com

MINI-PS AC/24DC/1.3

QUINT-PS/ 3AC/24DC/10

QUINT-PS AC/24DC/40

MACX MCR-UI-UI-UP(-SP)(-NC)

Analog signal converters CC-E I/I

QUINT-PS/ 3AC/24DC/40

PHOENIX CONTACT - 05/2008. DANGER OF EXPLOSION! Remove an item only when it is not connected to power or if it is located in the non-explosive area.

Measuring and monitoring relays CM-SRS.1 Current monitoring relays, single-phase AC/DC

QUINT-PS/ 1AC/24DC/20

MCR-PSP MCR Threshold Value Switch, Programmable

MCR-SL-CUC Universal current transducer. Data sheet _en_05. 1 Description

PHOENIX CONTACT - 06/2008. Features. DANGER OF EXPLOSION! Only remove equipment when it is disconnected and not in the potentially explosive area.

Electronic timer CT-SDD.22

5 years! Modular Housings. VariTrans P Warranty

Signal conditioner - MACX MCR-UI-UI-NC

Electronic timer CT-SDS.22 Star-delta change-over with 2 n/o contacts Data sheet

MODEL IAMA - UNIVERSAL SIGNAL CONDITIONING MODULE

CONTA-ELECTRONICS. Converter Units

Medium Converter FL MC 10BASE-T/FO G850

Guidance and Declaration - Electromagnetic Compatibility (EMC) for the Delfi PTS ii Portable Tourniquet System

CM-MPS.11, CM-MPS-21, CM-MPS.31 and CM-MPS.41 Data sheet. UL 508, CAN/CSA C22.2 No.14 GL GOST CB scheme CCC

Current monitoring relays CM-SRS.2 for single-phase AC/DC currents

Type CP-S, CP-C & CP-A Switch mode

Liquid level monitoring relay CM-ENS.2x

Electronic timer CT-TGD.22

Three-phase monitoring relays

Power supply CP-D 24/1.3

High precision measurement system for current and voltage IHC-A/B-RM01/03

Voltage monitoring relays CM-ESS.1 for single-phase AC/DC voltages

UNO-PS/1AC/24DC/150W. Primary-switched power supply unit. Data sheet. 1 Description

STEP-UPS/24DC/24DC/3. Uninterruptible power supply. Data sheet. 1 Description. Features

Power supply CP-E 24/2.5

ABB NEW. Three-phase monitoring relays. CM-PVS.31 and CM-PVS.41 Data sheet. Features J. Approvals. Marks. Order data. Order data - Accessories

Power supply CP-E 24/20.0

Current monitoring relays CM-SRS.1 for single-phase AC/DC currents

MACX MCR-EX-SL-RPSSI-I-UP(-SP)

NOVOHALL Rotary Sensor touchless technology transmissive. Series RFC4800 analog

Power supply CP-E 24/2.5

Voltage monitoring relay CM-EFS.2 For single-phase AC/DC voltages

Power supply CP-E 12/10.0 Primary switch mode power supply Data sheet

Electronic timer CT-SDS.22

08/07/2015

Current monitoring relays CM-SRS.1 For single-phase AC/DC currents

ABB NEW. Multifunctional three-phase monitoring relays. CM-MPS.23 and CM-MPS.43 Data sheet. Features J. Approvals. Marks.

08/07/2015

IB IL AI 2/SF. Function. INTERBUS Inline Terminal With Two Analog Input Channels. Data Sheet 5564A

ABB 1. Multifunctional three-phase monitoring relays. CM-MPS.11, CM-MPS-21, CM-MPS.31 and CM-MPS.41 Data sheet. Features. Approvals. Marks.

Notes: Note1: Efficiency is tested at nominal input and full load at +25 C ambient. Output Voltage 400VAC 400VAC

Power supply CP-E 48/5.0 Primary switch mode power supply Data sheet

Notes: Note1: Efficiency is tested at nominal input and full load at +25 C ambient. Output Voltage 400VAC 320VAC 360VAC 400VAC 400VAC

Current monitoring relays CM-SRS.2 For single-phase AC/DC currents

Electronic timer CT-ERS ON-delayed with 2 c/o contacts Data sheet

Analog signal converters CC range

EMD-FL-3V-400. Electronic monitoring relay for voltage monitoring in three-phase networks. INTERFACE Data sheet _en_03. 1 Description.

Note The module converts unipolar and bipolar input signals

Pressure Transmitter Type AKS 32 and AKS 33 REFRIGERATION AND AIR CONDITIONING. Technical leaflet

EMD-FL-C-10. Current Monitoring Relay. Data Sheet. Functions. Structure 08/2004

FieldIT Temperature Transmitter, rail mounted TH102/TH102-Ex

NOVOHALL Rotary Sensor non-contacting. Series RSC2800 analog

02/11/2015

Rail mounted Temperature Transmitter TH102/TH102-Ex

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

"Modular" versions designed for application-specific functions LCD with 4 lines of 18 characters and configurable backlighting

Modem 9600 baud 500FSD11 EDS500 series - FSK modems

Power supply CP-D 12/2.1

Power supply CP-D 24/4.2 Primary switch mode power supply

Datasheet. messtechnik gmbh. Torque ranges from 0,5 to 1000 Nm. Features. Extra Features DRBK-A. Torque Transducer DRBK + DRBK-A

Custom "Compact" range with display CD20 Custom Part number

Electronic timer CT-AHS.22 OFF-delayed with 2 c/o (SPDT) contacts

Electronic timer CT-EBE Flasher starting with OFF, 1 c/o (SPDT) contact

Power supply CP-E 24/0.75

Electronic timer CT-AWS Impulse-OFF with 1 c/o contact Data sheet

LS200 TEST DATA IEC61000 SERIES

Overcurrent Protection / 7SJ45

Electronic timer CT-MVS.12 Multifunctional with 1 c/o (SPDT) contact

Electromagnetic compatibility Guidance and manufacturer s declaration DIN EN :2007 (IEC :2007)

Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection)

REK 510 Current injection device for earth-fault protection of a synchronous machine rotor. User s Manual

NOVOHALL Rotary Sensor non-contacting. Series RSC-2800

TRIO-PS-2G/1AC/24DC/5

BIODEX MULTI- JOINT SYSTEM

Electronic timer CT-WBS.22 Impulse generating and flashing with 2 c/o (SPDT) contacts

Switching power supplies CP range, Linear power supplies CP-L range. Content

TMT Series, 10 to 50 Watt. Order Code Output Power Output 1 PCB-Mount Chassis Mount max.

Note1: Efficiency is tested at nominal input and full load at +25 C ambient Note2: Max Cap Load is tested at nominal input and full resisitive load

TPP 40 Series, 40 Watt. Order code Output voltage Output current max. Efficiency. max. screw terminal pin connector Vout 1 Vout 2 Vout 3

Current monitoring relays CM-SRS.M1 For single-phase AC/DC currents

Three-phase monitoring relays CM-PFE and CM-PFE.2

Electronic timer CT-MVS.23 Multifunctional with 2 c/o (SPDT) contacts

Programmable Universal Frequency Transducer

Isolated, Linearized Thermocouple Input 7B47 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

Transcription:

MCR-C-UI-UI-DCI MCR 3-Way Isolation Amplifier, Configurable 1. Short description configurable inputs and outputs signal conversion/amplification 3-way-isolation zero/span adjustment 17.5 mm ME housing The MCR 3-way modules are used for electrical isolation and conversion of analog signals. The modules guarantee electrical isolation of standard analog signals. The module input and ouput electronics are isolated by a DC/DC converter from the auiliary supply (3-way-isolation, fig. 2). U, I U, I Fig. 2 The required auiliary power supply is signalized via a green power LED. Thus it is clearly evident whether an auiliary power supply is available. The MCR modules ensure reliable decoupling of a sensor circuit from the processing circuit and thus also avoid cross-coupling of several sensor circuits. The 3-way isolation means that the modules can be used universally, both on site or in the vicinity of the controller for the conversion of signals and as electrical isolation, and along the transmission path to bridge apparent ohmic resistance. Two sealed potentiometers with front access allow an adjustment between zero and span in order to perform a measuring adjustment. The desired configuration to which the device is to be adapted (see ordering eample and combination table) must be indicated when ordering. If no information is given after the ordering eample provided (page 4), the devices are delivered with the standard configuration (input signal 0-10 V, output signal 0-10 V). Fig. 1 DIP switches allow a reconfiguration of the inputs and outputs of the isolation amplifiers so that more than 200 signal variations are possible. Signal conversion and the electrical isolation of the analog signals is carried out using an inductive transmission process. In addition, a filter downstream of the transmitter reduces interference. The MCR 3-way modules snap onto symmetrical mounting rails according to EN 50 022. The signal lines are securely connected to the module via pluggable screw connections and are clearly marked. Headquarters: Phoeni Contact GmbH & Co. Flachsmarktstraße 8 32825 Blomberg Germany Phone +49-(0) 52 35-3-00 Fa +49-(0) 52 35-3-4 1200 http://www.phoenicontact.com

114,5 MCR-C-UI-UI-DCI MCR 3-Way Isolation Amplifier, Configurable 99 17,5 Fig. 3 Fig. 4 IN U/I GND 1 GND 1 IN OUT 1 U, 7 2 U 8 3 9 OUT I OUT U GND 2 0! " 24VDC GND 3 GND 3 Aa (F )2) MCR-C-UI-UI-DCI with configurable input and output (IEC) rigid fleible [mm 2 ] solid rigid AWG Connection data 0.2-2.5 0.2-2.5 24-14 Fig. 5 2. Description Type Order No. MCR 3-way-isolator, for analog signal isolation MCR-C-UI-UI-DCI 1) 28 10 91 3 1 MCR 3-way-isolator, as above, however with a cut-off frequency of (3 db) 450 Hz MCR-C-UI-UI-450-DCI 1) 28 10 88 7 1 Pcs. Pkt. 2.1. Technical Data Input Input signal Possible adjustment: Ma. input signal Input resistance Output Output signal Ma. output signal Load zero span 0 10 V, indicate other setting in the order ± 2 % ± 2 % 30 V or 50 ma 1 MΩ at U-input 50 Ω at I-input 0 10 V, indicate other setting in the order 15 V or 30 ma 10 kω at U-output 500 Ω at I-output 2.2. General Data MCR-C-UI-UI-DCI MCR-C-UI-UI-450-DCI Supply voltage Current consumption (without load) Transmission error Temperature coefficient Cut-off frequency (3 db) Ascent time (10-90 %) Test voltage: Protection circuit Ambient temperature range Type of connection Installed position / mounting Dimensions (W / H / D) Conductor diameter Type of housing input/output auiliary power supply/signal 18 30 V 18 30 V < 30 ma < 30 ma 0.1 % of end value 0.1 % of end value 0.0075 %/K 0.0075 %/K 30 Hz 450 Hz 11 ms 0.8 ms 1.5 kv, 50 Hz, 1 min. 1.5 kv, 50 Hz, 1 min. 1 kv, 50 Hz, 1 min. 1 kv, 50 Hz, 1 min. transient protection transient protection -20 C to +65 C -20 C to +65 C pluggable screw terminal pluggable screw terminal COMBICON COMBICON as desired as desired (17.5 / 99 /114.5) mm (17.5 / 99 /114.5) mm 0.2-2.5 mm 2 (AWG 24-14) 0.2-2.5 mm 2 (AWG 24-14) polyamide PA unreinforced polyamide PA unreinforced 1) If no further details are given as to configuration, the device is supplied in the standard configuration (see order key, page 4)! 2) Only MCR-C-UI-UI-DCI Order No.: 28 10 91 3 PHOENIX CONTACT page 2 of 11

2.3. EMC Electromagnetic Compatibility c Complies with EMC guideline 89/336/EEC and low voltage directive 73/23/EEC Immunity to interference in acc. with EN 50082-2 Electrostatic discharge (ESD) Electromagnetic HF field: Amplitude modulation Pulse modulation EN 61000-4-2 EN 61000-4-3 Criterion B 8 kv discharge in air Criterion A 10 V/m 10 V/m Fast transients (Burst) Surge voltage capacities (Surge) Conducted disturbance EN 61000-4-4 EN 61000-4-5 EN 61000-4-6 Criterion B I/O/S 1) : 2 kv/5 khz Criterion B I/O 1) : 2 kv/42 Ω Criterion A I/O/S 1) : 10 V Noise emission in acc. with EN 50081 EN 55011 Class A EN 61000 corresponds to IEC 1000 EN 55011 corresponds to CISPR11 1) I= Input / O=Output / S=Supply Criterion A: Normal operating behavior within the defined limits. Criterion B: Temporary impairment to operational behavior that is corrected by the device itself. Class A: Area of application: industry, without special installation measures. 2.4. Connection Scheme MCR 3-way isolation amplifier, configurable 1 pluggable screw terminal blocks (supply, signal output) 2 ZERO/SPAN potentiometer 2 MCR-C-UI/UI-DCI ZERO SPAN I +24V GND3 GND3 OUT U GND2 1 3 pluggable screw terminal block (signal input) 4 upper part of housing can be slid open to set DIP switches 5 Metal latch for fiing to the mounting rail 4 3 4 5 6 1 2 3 U/I IN GND1 GND1 IN U, U MCR-C-UI/UI-DCI Art.-Nr.: 28 10 91 3 OUT 1 7 2 8 3 9 0! " 1 IN U/I OUT I 7 2 GND 1 OUT U 8 3 GND 1 GND 2 9 +24VDC 10 GND 3 11 GND 3 12 APPROBATIONEN / APPROVALS 5 Fig. 6 PHOENIX CONTACT page 3 of 11

PHOENIX CONTACT page 4 of 11 MCR-C-UI-UI-DCI MCR 3-Way Isolation Amplifier, Configurable 3. Order key 3.1. Combination table for input and output signals Further ranges are available on request! 3.2. Order key MCR-C-UI-UI-DCI Output Input 0-10 V ± 10 V 0-5 V ± 5 V 1-5 V 0-5 ma 0-10 ma 0-20 ma 4-20 ma 0-60 mv 0-100 mv 0-200 mv 0-300 mv 0-500 mv 0-1 V 0-2 V 0-2.5 V 0-5 V 0-10 V 0-20 V ± 60 mv ± 100 mv ± 200 mv ± 300 mv ± 500 mv ± 1 V ± 2 V ± 2,5 V ± 5 V ± 10 V ± 20 V 0-5 ma 0-10 ma 0-20 ma ± 5 ma ± 10 ma ± 20 ma 1-5 V 4-20 ma Input Output MCR-C-UI-UI-DCI / 0-10 V / 0-10 V for others, please refer to combination table for others, please refer to combination table

4. Notes on Connection 4.1. Standard setting: The 3-way isolation amplifier is supplied factory-adjusted, with sealed potentiometers. The set configuration is indicated in handwriting on the side label. 4.2. Configuration 4.2.1. Opening the device (Fig. 7) The snap lock of the upper part of the housing is released on both sides with the help of a screwdriver 1. The upper part of the housing and the electronics can now be pulled out by about 3 cm. 1 2 3 1 4 5 6 2 IN 1 2 3 U, U 3 2 1 IN U/I GND 1 GND 1 Fig. 7 4.2.2. Changing the configuration Setting of the required input range by means of switch DIP 1, and of the output range by means of DIP 2 (see Fig. 8) as indicated in the relevant table. HYBRID TV1 PHOENIX CONTACT DIP 1 DIP 2 Fig. 8 PHOENIX CONTACT page 5 of 11

4.3.Setting of the signal ranges 4.3.1.Input signal range (DIP 1) Select one of the possible input signal ranges by configuring the switch DIP 1 according to table 1. Eception: Bipolar input signals are not allowed for the output signal ranges 4 20 ma and 1 5 V (see tables 4/6, page 9/10)! Table 1 Switch DIP 1 Input 1 2 3 4 5 6 7 8 0 60 mv ON ON ON ON 0 100 mv ON ON 0 200 mv ON ON 0 300 mv ON ON ON 0 500 mv ON ON 0 1 V ON ON 0 2 V ON ON 0 2.5V ON 0 5 V ON 0 10 V ON 0 20 V ON HYBRID TV1 PHOENIX CONTACT DIP 1 Fig. 9 ± 60 mv ON ON ON ON ± 100 mv ON ON ± 200 mv ON ON ± 300 mv ON ON ON ± 500 mv ON ON ± 1 V ON ON ± 2 V ON ON ± 2.5 V ON ± 5 V ON ± 10 V ON ± 20 V ON 0 5 ma ON ON ON ON ON 0 10 ma ON ON ON 0 20 ma ON ON ON ± 5 ma ON ON ON ON ON ± 10 ma ON ON ON ± 20 ma ON ON ON 1 5 V ON 4 20 ma ON ON ON PHOENIX CONTACT page 6 of 11

4.3.2. Output (DIP 2) with single adjustment (0 5 V / 0 10 V output) Set the output range by means of switch DIP 2. Take the selected input range into account! Set the lower range value and the upper range (full-scale) value of the input signal, using a calibration source. Adjust the respective output value with a digital multimeter (see table 2). HYBRID TV1 PHOENIX CONTACT DIP 2 Fig. 10 Table 2 Output 0 5 V 0 60 mv ON ON 0 100 mv ON ON 0 200 mv ON ON 0 300 mv ON ON 0 500 mv ON ON 0 1 V ON ON 0 2 V ON ON 0 2.5 V ON ON 0 5 V ON ON 0 10 V ON ON 0 20 V ON ON ± 60 mv ON ON ON ± 100 mv ON ON ON ± 200 mv ON ON ON ± 300 mv ON ON ON ± 500 mv ON ON ON ± 1 V ON ON ON ± 2 V ON ON ON ± 2.5 V ON ON ON ± 5 V ON ON ON ± 10 V ON ON ON ± 20 V ON ON ON 0 5 ma ON ON 0 10 ma ON ON 0 20 ma ON ON ± 5 ma ON ON ON ± 10 ma ON ON ON ± 20 ma ON ON ON 1 5 V ON 4 20 ma ON Output 0 10 V 0 60 mv ON ON ON 0 100 mv ON ON ON 0 200 mv ON ON ON 0 300 mv ON ON ON 0 500 mv ON ON ON 0 1 V ON ON ON 0 2 V ON ON ON 0 2.5 V ON ON ON 0 5 V ON ON ON 0 10 V ON ON ON 0 20 V ON ON ON ± 60 mv ON ON ON ON ± 100 mv ON ON ON ON ± 200 mv ON ON ON ON ± 300 mv ON ON ON ON ± 500 mv ON ON ON ON ± 1 V ON ON ON ON ± 2 V ON ON ON ON ± 2.5 V ON ON ON ON ± 5 V ON ON ON ON ± 10 V ON ON ON ON ± 20 V ON ON ON ON 0 5 ma ON ON ON 0 10 ma ON ON ON 0 20 ma ON ON ON ± 5 ma ON ON ON ON ± 10 ma ON ON ON ON ± 20 ma ON ON ON ON 1 5 V ON ON 4 20 ma ON ON Adjustment after set value of the lower or upper range value to: Output 0 5 V Output 0 10 V ZERO pot 0 V ± 0.5 mv 0 V ± 0.5 mv SPAN pot 5 V ± 0.5 mv 10 V ± 0.5 mv PHOENIX CONTACT page 7 of 11

4.3.3. Output with adjustment point calculation (±5 V / ±10 V/1 5 V/0...5;10;20 ma/4 20 ma ) Set the output range by means of switch DIP 2. Take the selected input range into account! Set the lower range value and the upper range (full-scale) value of the input signal, using a calibration source. Note down the output value measured with a digital multimeter. Output signal range: ± 5 V, ± 10 V,1 5 V, 4 20 ma, 0 20 ma Set value (input) Lower range value Measured value (output) MW 1 Upper range (full scale) value MW 2 Set value (input) Lower range value +10% of the range Measured value (output) MW 1 Upper range (full scale) value MW 2 Calculation of the F.S. adjustment point A A = MW 2 constant MW2 - MW 1 Refer to the following tables 3-5, page 8-9 for the values for the constant, the output upper range value and adjustment tolerance! Adjustment: Set the upper range (full-scale) value of the input signal range using a calibration source. SPAN pot: FS adjustment point A ± adjustment tolerance ZERO pot: output upper range (full-scale) ± adjustment tolerance Table 3 Output ± 5 V Output ± 10 V 0 60 mv ON ON ON ON ON 0 100 mv ON ON ON ON ON 0 200 mv ON ON ON ON ON 0 300 mv ON ON ON ON ON 0 500 mv ON ON ON ON ON 0 1 V ON ON ON ON ON 0 2 V ON ON ON ON ON 0 2.5 V ON ON ON ON ON 0 5 V ON ON ON ON ON 0 10 V ON ON ON ON ON 0 20 V ON ON ON ON ON ± 60 mv ON ON ± 100 mv ON ON ± 200 mv ON ON ± 300 mv ON ON ± 500 mv ON ON ± 1 V ON ON ± 2 V ON ON ± 2.5 V ON ON ± 5 V ON ON ± 10 V ON ON ± 20 V ON ON 0 5 ma ON ON ON ON ON 0 10 ma ON ON ON ON ON 0 20 ma ON ON ON ON ON ± 5 ma ON ON ± 10 ma ON ON ± 20 ma ON ON 1 5 V ON ON ON 4 20 ma ON ON ON 0 60 mv ON ON ON ON ON ON 0 100 mv ON ON ON ON ON ON 0 200 mv ON ON ON ON ON ON 0 300 mv ON ON ON ON ON ON 0 500 mv ON ON ON ON ON ON 0 1 V ON ON ON ON ON ON 0 2 V ON ON ON ON ON ON 0 2.5 V ON ON ON ON ON ON 0 5 V ON ON ON ON ON ON 0 10 V ON ON ON ON ON ON 0 20 V ON ON ON ON ON ON ± 60 mv ON ON ON ± 100 mv ON ON ON ± 200 mv ON ON ON ± 300 mv ON ON ON ± 500 mv ON ON ON ± 1 V ON ON ON ± 2 V ON ON ON ± 2.5 V ON ON ON ± 5 V ON ON ON ± 10 V ON ON ON ± 20 V ON ON ON 0 5 ma ON ON ON ON ON ON 0 10 ma ON ON ON ON ON ON 0 20 ma ON ON ON ON ON ON ± 5 ma ON ON ON ± 10 ma ON ON ON ± 20 ma ON ON ON 1 5 V ON ON ON ON 4 20 ma ON ON ON ON PHOENIX CONTACT page 8 of 11

Output ±5 V Output ±10 V Table 5 Output 0 10 ma Constant 10 V 20 V Output upper range v. 5 V 10 V Adjustment tolerance ± 0.5 mv ± 0.5 mv Table 4 Output 1 5 V 0 60 mv ON ON 0 100 mv ON ON 0 200 mv ON ON 0 300 mv ON ON 0 500 mv ON ON 0 1 V ON ON 0 2 V ON ON 0 2.5 V ON ON 0 5 V ON ON 0 10 V ON ON 0 20 V ON ON 0 5 ma ON ON 0 10 ma ON ON 0 20 ma ON ON 4 20 ma ON ON 1 5 V ON ON Output 1...5 V 0 60 mv ON ON 0 100 mv ON ON 0 200 mv ON ON 0 300 mv ON ON 0 500 mv ON ON 0 1 V ON ON 0 2 V ON ON 0 2.5 V ON ON 0 5 V ON ON 0 10 V ON ON 0 20 V ON ON ± 60 mv ON ON ON ± 100 mv ON ON ON ± 200 mv ON ON ON ± 300 mv ON ON ON ± 500 mv ON ON ON ± 1 V ON ON ON ± 2 V ON ON ON ± 2.5 V ON ON ON ± 5 V ON ON ON ± 10 V ON ON ON ± 20 V ON ON ON 0 5 ma ON ON 0 10 ma ON ON 0 20 ma ON ON ± 5 ma ON ON ON ± 10 ma ON ON ON ± 20 ma ON ON ON Constant Output upper range v. Adjustment tolerance 4 V 5 V ± 1 mv 1 5 V ON 4 20 ma ON Table 5 Output 0 5 ma 0 60 mv ON ON ON 0 100 mv ON ON ON 0 200 mv ON ON ON 0 300 mv ON ON ON 0 500 mv ON ON ON 0 1 V ON ON ON 0 2 V ON ON ON 0 2.5 V ON ON ON 0 5 V ON ON ON 0 10 V ON ON ON 0 20 V ON ON ON 0 5 ma ON ON ON 0 10 ma ON ON ON 0 20 ma ON ON ON PHOENIX CONTACT page 9 of 11

Table 6 Output 0 20 ma 0 60 mv ON ON ON 0 100 mv ON ON ON 0 200 mv ON ON ON 0 300 mv ON ON ON 0 500 mv ON ON ON 0 1 V ON ON ON 0 2 V ON ON ON 0 2.5 V ON ON ON 0 5 V ON ON ON 0 10 V ON ON ON 0 20 V ON ON ON ± 60 mv ON ON ON ON ± 100 mv ON ON ON ON ± 200 mv ON ON ON ON ± 300 mv ON ON ON ON ± 500 mv ON ON ON ON ± 1 V ON ON ON ON ± 2 V ON ON ON ON ± 2.5 V ON ON ON ON ± 5 V ON ON ON ON ± 10 V ON ON ON ON ± 20 V ON ON ON ON 0 5 ma ON ON ON 0 10 ma ON ON ON 0 20 ma ON ON ON ± 5 ma ON ON ON ON ± 10 ma ON ON ON ON ± 20 ma ON ON ON ON 1 5 V ON ON 4 20 ma ON ON Output 4 20 ma 0 60 mv ON ON ON 0 100 mv ON ON ON 0 200 mv ON ON ON 0 300 mv ON ON ON 0 500 mv ON ON ON 0 1 V ON ON ON 0 2 V ON ON ON 0 2.5 V ON ON ON 0 5 V ON ON ON 0 10 V ON ON ON 0 20 V ON ON ON ± 60 mv ± 100 mv ± 200 mv ± 300 mv ± 500 mv ± 1 V ± 2 V ± 2.5 V ± 5 V ± 10 V ± 20 V 0 5 ma ON ON ON 0 10 ma ON ON ON 0 20 ma ON ON ON ± 5 ma ± 10 ma ± 20 ma 1 5 V ON ON ON 4 20 ma ON ON ON Output 0 20 ma Output 4 20 ma Constant 18 ma 16 ma Output upper range v. 20 ma 20 ma Adjustment tolerance ± 1 µa ± 1 µa PHOENIX CONTACT page 10 of 11

4.4. Adjustment Adjustment of the module by means of two potentiometers (see Fig. 11) ZERO pot: 0-point adjustment SPAN pot: upper range (full-scale) adjustment I +24V GND3 GND3 OUT U GND2 Allow a module warm-up time of 2 minutes before the adjustment! MCR-C-UI/UI-DCI SPAN ZERO U/I IN 5. Application eample: PH measurement of a liquid (Fig. 12) 0...100mV electrode measurement solution 1 U/I 2 GND 1 3 GND 1 M CR- C- UI/UI- DCI Pow er SPAN ZERO GND1 GND1 OUT U GND 2 7 8 9 (+) 24V GND 3 GND 3 0! " 0...10V control MCR-C-UI/UI-DCI Nr : 28 10 91 3 24V mains voltage Fig. 11 Fig. 12 PHOENIX CONTACT 15.08.98 TNR: 5087125-00 http://www.phoenicontact.com PHOENIX CONTACT page 11 of 11