Installation Guidelines, 10Gig SFP+ Direct Attach Copper Cable Assembly PN533A

Similar documents
SFP+ Active Copper Cable. Datasheet. Quellan Incorporated F e a t u r e s A P P L I C A T I O N S. O r d e r i n g

25G SFP28 Active Optical Cable OPSF28-F-xx-AKT Datasheet

TPP3XGDS0x000E2G 850nm SFP+ Transceiver

1550nm 40km SFP+ Transceivers

This 1310 nm DFB 10Gigabit SFP+ transceiver is designed to transmit and receive optical data over single mode optical fiber for link length 10km.

Features. Compliance. Applications. Warranty: GigaTech Branded Cables- Lifetime Warranty

10GBase LR-Lite SFP+ Optical Transceivers (I-Temp)

Hybrid Passive Copper 100GE QSFP28 to 4x 25GE SFP28 GQS-4P28+PC-XXXXC

1550nm 40km SFP+ Transceiver

SFP-10G-M 10G Ethernet SFP+ Transceiver

10Gb/s SFP+ Optical Transceiver Module 10GBASE-SR/SW

LEG. 10Gbs SFP+ Transceiver

FCOPPER-SFP BASE-TX Copper SFP Transceiver

Features. Compliance. Applications. Warranty: GigaTech Branded Cables- Lifetime Warranty

Product Specification

DWDM 80km SFP+ Transceiver

Part Number Transmitter Output Power Receiver Sensitivity Reach Temp DDM RoHS

2.5Gbps SFP Transceiver

LTF8506 SFP+ AOC 10G Ethernet SFP+ Active Optical Cable

4.25Gbps SFP Transceiver

Product Specification

Optical Transceiver Module - SFP

SFP+ Cable Assemblies, 0.5m/1m/2m/3m/4m/5m/6m/7m/8m/9m/10m/11m/12m/15m Reach RoHS6 Compliant. Lengt

SO-QSFP28-4xSFP28-AOCxM

T A S A 1 N H 1 P 1 1

PT (2)-1W. OC-3 SR/IR-1 / STM S-1.1 SFP Transceiver

SNR-SFP-LX 1.25Gbps. Features. Applications. Product Description

QFX-SFP-10GE-SR (10G BASE-SR SFP+) Datasheet

10Gb/s CWDM SFP+ Optical Transceiver TR-LXxxL-N00

10GBase SR/SW SFP+ Optical Transceivers WST-SFP+SR-C

EMPOWERFIBER 10Gbps 300m SFP+ Optical Transceiver EPP SRC

PROLABS QSFP-4x10G-AC7M-C QSFP+ to 4 SFP+ Active Copper Cable Assembly

PT (2)-1W(+) GbE 1000Base-LX 10 km SFP Transceiver

SFP-1.25G-LX 1.25Gbps SFP Optical Transceiver, 10KM Reach

XTS31U-10Lx. 10 G Ethernet 10 km SFP+ Transceiver 10GBASE-LR/10GBASE-LW. XTS31U-10Lx 10 G 10 km SFP+ Transceiver. Applications.

Parameter Minimum Maximum Units Supply voltage V Data input voltage V Control input voltage V

SFP+ Dual LC 10G SMF 10Km 1310nm Transceiver. Features. Applications. Ordering Information APPLIED OPTOELECTRONICS, INC.

SFP+ Copper 10GBase-T SL-SFP-10G-T

407-BBOS-A 407-BBOS-A. Features. Up to 1.25Gb/s bi-directional data links. Hot-pluggable SFP footprint

PT0-M3-4D33Q-I. Product Overview. Absolute Maximum Ratings.

SFP+ Series. 1550nm SFP+ single-mode Transceiver, With Diagnostic Monitoring Duplex SFP+ Transceiver RoHS 6 Compliant

SFP+ BIDI Series GigaStream BIDI-10G-SFP-40A & BIDI-10G-SFP-40B

Part Number Transmitter Output Power Receiver Sensitivity Reach Temp DDM RoHS

MODULETEK DAC-QSFP10-QSFP10-A-M-xxAWG-aa.aaM-C0C0C QSFP+ to 4 SFP+ Active Copper Cable Assembly. DAC-QSFP10-QSFP10-A-M-xxAWG-aa.

SFP-10G-SR-LEG. 10Gbs SFP+ Transceiver

10GBase SFP+ LR/LW Optical Transceivers Series WST-SFP+LR-C

Part No. Data Rate Media type Distance

10Gb/s SFP+ BX LC DDMI Optical module Tx:1330nm/Rx:1270nm 10km transmission distance

SFP-CWDMxx.60. CWDM* Wavelength (0 to 70 o C)

SFP+ Series SFP-10G-SR

T A S A 5 N B 1 F A H

LEG. 10Gbps SFP+ Transceiver

SO-SFP28-LR. SFP28, 25GBASE-LR, 1310nm, SM, DDM, 10km OVERVIEW PRODUCT FEATURES APPLICATIONS ORDERING INFORMATION DATASHEET 4.1

6Gbps SFP+ Optical Transceiver,10 Km (OP3B10D ) Hot Pluggable, Duplex LC, +3.3V 1310nm DFB-LD. Features

10G CWDM SFP+ 40km ER Transceiver Hot Pluggable, Duplex LC, +3.3V, 1470~1610nm CWDM EML, DDMI PSFP10-1C41SF-XX

1.25Gbps Single Fiber Bi-directional SFP, ONU Transceiver

SFP+ BIDI Series JB1270-SFP-LC.S20

NBASE-T Copper Transceiver Small Form Factor Pluggable (SFP+), 3.3V 100M/1G/2.5G/5G/10Gbps Ethernet. Features

XTBxxA-20LY 10 Gbps SFP+ Bi-Directional Transceiver, 20 km Reach

SFP- 10G- GIG- SR- AO. 10Gbs SFP+ Transceiver

GBP-XXXX192-L2C 10Gbps SFP+ Bi-Directional Transceiver, 20km Reach 1270/1330nm TX / 1330/1270 nm RX

SFP+ Dual LC 10G MMF 300m 850nm Transceiver. Features. Applications. Ordering Information APPLIED OPTOELECTRONICS, INC.

AXGE Gbps Single-mode 1310nm, SFP Transceiver

10Gb/s DWDM Single-mode SFP+ Transceiver

SFP+ BIDI Series JB1270-SFP-LC.S40. Features. Applications. Ordering information

SFP-1020-WA/B 10Gbps SFP+ Bi-Directional Transceiver, 20km Reach 1270/1330nm TX / 1330/1270 nm RX

SFP+ ER TDM 1550nm 10G SMF 40km Transceiver. Features. Applications. Ordering Information APPLIED OPTOELECTRONICS, INC.

Features. Compliance. Applications. Warranty: GigaTech Branded Cables- Lifetime Warranty. SFP-10G-AOCxM-GT 10GBASE-AOC SFP+ Cable Cisco Compatible- xm

10G SFP+ SR/SW Transceiver Hot Pluggable, Duplex LC, 850nm VCSEL, Multi Mode, 300M, DDM. Overview:

125Mbps~155Mbps Multimode 850nm, SFP Transceiver

EOLS-1312-XXXX 1.25Gbps SFP Transceiver

SFP28 Series Preliminary EOLP-8525G-02-R. Features. Applications. Ordering information

SFP+-CWDM-xx-40D. 10Gbps CWDM SFP+ Optical Transceiver, 40km Reach

SFP+-DWDM-xx-80D. 10Gbps DWDM SFP+ Optical Transceiver, 80km Reach

DWDM SFP+ Series DWDM EML

OCTECH 1.25Gbps SFP Transceiver

DATASHEET 4.1. SFP+, 10GBase-ZR, Multirate Gbps, C Tunable, DWDM, C-Band, 50GHz, 22dB, 80km, ind. temp.

10G SFP+ CWDM 20km Transceiver Hot Pluggable, Duplex LC, +3.3V, 1270~1350nm CWDM DFB, DDMI PSFP-2C41SF-XX

Product Features. Applications. Descriptions. Ordering Information. LX432xCDR 10GEthernet 40km CWDM SFP+ Transceiver 10GBASE-LR / 10GBASE-LW

SFP BIDI 2.5Gbps 40Km Tx1310/Rx1550nm / Tx1550/Rx1310nm

SFP+-10GB-ZR. 10Gbps SFP+ Optical Transceiver, 80km Reach

SFP-10G-LR-TX. Product Features. Applications. Product Selection. Cisco Compatible 10GBase-LR SFP TurboX

SFP Series IOLS-1348-XXXX. 4.25Gbps up to 30 km transmission. version 0.1 FEATURES PRODUCT DESCRIPTION

1000BASE-T SFP Copper Transceiver Hot Pluggable, Cat-5 UTP Cable, 100m

PERFORMANCE SPECIFICATIONS - ELECTRICAL

XBR C. 8Gbs SFP+ Transceiver

10Gb/s CWDM SFP+ 20Km RT-P10LCM-C00-xx. Optical Transceiver

Preliminary Product Specification Quadwire 40 Gb/s Parallel Breakout Active Optical Cable FCBN510QE2Cxx APPLICATIONS

Regulatory Compliance Electrostatic Discharge (ESD) to the Electrical Pins Electrostatic Discharge to the enclosure Electromagnetic Interference (EMI)

AXM762-A AXM762-A. Features. Up to 11.1Gbps Data Links. Up to 10km transmission on SMF. DBF Laser and PIN receiver. Metal enclosure, for lower EMI

Pluggable Input / Output Solutions

Parameter Symbol Min Typ Max Unit Remarks Data Rate DR 1.25 GBd IEEE Bit Error Rate BER Input Voltage V CC

SO-SFP-100Base-T. SFP, 125Mbps FE to 10/100Base-T convert SO-SFP-100BASE-T OVERVIEW PRODUCT FEATURES APPLICATIONS ORDERING INFORMATION DATASHEET 4.

155Mbps Single-mode 1310nm, SFP Transceiver

10Gbps 1550nm 80KM SFP+ Optical Transceiver 10Gbps 850nm 300M SFP+ Optical Transceiver

PRODUCT SPECIFACTION

OCTECH 1.25Gbps SFP Transceiver

SFP 4.25G 850nm Multi mode Optical Transceiver

High Speed Interconnects

XGSPON ONU Optical Module

Transcription:

Installation Guidelines, 10Gig SFP+ Direct Attach Copper Cable Assembly Introduction As virtualization, consolidation, and convergence initiatives continue to expand in Data Centers, so do the demands placed on the physical infrastructure. To meet the needs for higher bandwidth along with lower power interconnects, Panduit offers 10Gig SFP+ Direct Attach Copper Cable Assemblies. This high speed data transport capability is ideal as server virtualization becomes more prevalent. 10Gig interconnects are needed to facilitate effective server utilization to run multiple virtual machines as well as server consolidation. By incorporating 10Gig SFP+ Copper Cable Assemblies into the physical infrastructure, organizations can achieve 10Gig performance without additional signal processing or conversion. This provides an ideal low power, low latency 10 Gbps server interconnect option for top of rack switching deployments. Passive 10Gig SFP+ Copper Cable Assemblies generally have a reach limitation of 7 meters (23 feet), and many network deployments will consist of a mixed copper/fiber solution with Panduit 10Gig OM3 fiber. Panduit 10Gig SFP+ Direct Attach Copper Cable Assemblies Panduit 10Gig SFP+ Copper Cable Assemblies are factory terminated and constructed of high-speed twin-axial shielded cable with SFP+ modular connectors on each end. The cables are compliant to the SFF-8431 specification. The Small Form Factor committee approved and published SFF-8431 in July of 2009, with Panduit as a member and a signee. The document covers host ports, optical transceivers, and copper cables. Appendix E specifies direct attach copper cable assemblies. These passive cable assemblies offer a low power, low latency, low cost option for a 10Gig interconnect. They may be plugged into SFF-8431 SFP+ compliant ports and are interchangeable with fiber optic transceivers. (Note: some system vendors have designed copper-only or fiber-only SFP+ ports, so be sure to confirm host port capabilities with the active equipment vendor) The Panduit 10Gig SFP+ Direct Attach Cable Assemblies are constructed with high frequency 10 GHz 100 ohm parallel shielded pairs, with two wire pairs in the cable. Panduit uses 30AWG for cables less than 4 meters in length and uses 24AWG for 4 meter and longer cables. The connector consists of a paddle card with patent pending circuitry to ensure superior high frequency signal integrity, is housed in a die cast backshell, and incorporates a latching mechanism that allows insertion and de-insertion into the mechanical cage of a host port on the active equipment. The same host port cage can accept optical transceivers or direct attach cable assemblies. The back of the paddle card has pads which form the contacts to the 20 pin host connector inside the cage. The connector has an EMI shroud that provides 360 degrees of contact with the host cage to ensure excellent EMI immunity. Cross-section 2-pair twin-axial cable Panduit SFP+ connector Panduit Corporation, 2010 Page 1 of 7

Standard Cable Part Numbers Part Number Length* Cable Gauge Nominal Cable O.D. Weight/pc PSF1PXA0.5M** 0.5 m (1.6 ft) 30AWG 4.1 mm (0.16 in) 0.10 lb. PSF1PXA1M** 1.0M (1.6ft) 30AWG 4.1 mm (0.16 in) 0.13 lb. PSF1PXA1.5M** 1.5 m (4.9 ft) 30AWG 4.1 mm (0.16 in) 0.16 lb. PSF1PXA2M** 2.0 m (6.6 ft) 30AWG 4.1 mm (0.16 in) 0.19 lb. PSF1PXA2.5M** 2.5 m (8.2 ft) 30AWG 4.1 mm (0.16 in) 0.22 lb. PSF1PXA3M** 3.0 m (9.8 ft) 30AWG 4.1 mm (0.16 in) 0.25 lb. PSF1PXA3.5M** 3.5 m (11.5 ft) 30AWG 4.1 mm (0.16 in) 0.28 lb. PSF1PXD4M** 4.0 m (13.1 ft) 24AWG 5.6 mm (0.22 in) 0.49 lb. PSF1PXD5M** 5.0 m (16.4 ft) 24AWG 5.6 mm (0.22 in) 0.60 lb. PSF1PXD6M** 6.0 m (19.7 ft) 24AWG 5.6 mm (0,22 in) 0.70 lb. PSF1PXD7M** 7.0 m (23.0 ft) 24AWG 5.6 mm (0,22 in) 0.81 lb. * Panduit 10Gig SFP+ copper cables have a length tolerance of +.15-0 m ** Add cable color code to end of part number, BU for Blue, WH for White, BL for Black. Cable Length Deployment Note Note that the Panduit 10Gig SFP+ Direct Attach Cable Assembly lengths are measured from cable connector tip- to-tip. However, much of the connector is inserted into the host port. Therefore one may wish to add approximately 47mm or 1.87 inches to each end or approximately 0.1m total to port-to-port length and cord routing calculations. Connector EEPROM Panduit 10Gig SFP+ Direct Attach Copper Cable Assemblies are intelligent cables. The connector has an integrated EEPROM with information populated in registers that is provided to the active equipment when queried through an I 2 C bus Most active equipment port allow for interchangeable types of me to be plugged into its ports. The registers in the EEPROM provide a method for the connector to identify itself as an SFP+ passive copper module to allow the active equipment to operate in the proper mode. Other information contained in the memory registers includes vendor name (Panduit), part number, serial number, and cable length in meters. Panduit Corporation, 2010 Page 2 of 7

SFP+ Cable Assembly Connector Pin Out SFP+ Pin Assignment Definitions SFP Connector Module Contact Assignments (Top and Bottom are backwards) Contact Logic(1) Symbol Power Description Note Sequence Order Case Case Note 2 Module case 2 1 VeeT 1 st Module transmitter ground 3 2 LVTTL-O Tx_fault 3 rd Module transmitter fault (N/A) 4 3 LVTTL-I Tx_disable 3 rd Transmitter disable (N/A) 4 4 LVTTL-I/O SDA 3 rd 2-wire serial interface data line, same as MOD-DEF2 5 5 LVTTL-I/O SCL 3 rd 2-wire serial interface clock, same as MOD-DEF1 5 6 Mod_ABS 3 rd Module absent, connected to VeeT or VeeR in module 6 7 LVTTL-I RSO 3 rd Rate select 0, optionally controls SFP+ receiver (N/A) 4 8 LVTTL-O Rx_LOS 3 rd Receiver loss of signal indication (N/A) 4 9 LVTTL-I RS1 3 rd Rate select 1, optionally controls SFP+ transmitter (N/A) 4 10 VeeR 1 st Module receiver ground 3 11 VeeR 1 st Module receiver ground 3 12 CML-O RD- 3 rd Receiver inverted data output 13 CML-O RD+ 3 rd Receiver non-inverted data output 14 VeeR 1 st Module receiver ground 3 15 VccR 2 nd Module receiver 3.3V supply 16 VccT 2 nd Module transmitter 3.3V supply 17 VeeT 1 st Module transmitter ground 3 18 CML-I TD+ 3 rd Transmitter non-inverted data output 19 CML-I TD- 3 rd Transmitter inverted data output 20 VeeT 1 st Module Transmitter Ground 3 Notes: 1. Labeling as Input (I) and Output (O) are from perspective of the module (cable connector) 2. The case makes electrical contact to the host cage before any board edge contacts are made 3. The module signal grounds, VeeR and VeeT, should be isolated from the module case 4. Tx-fault, Tx_disable, rate select, and loss of signal functions are not implemented in passive copper cable assemblies 5. SDA and SCL are the data and clock pins for the I2C interface to the EEPROM on board the module. The registers are defined in SFF-8472. 6. Mod_ABS is an output pin to indicate if the module is present in the host port It is connected to ground in the module (cable connector) Panduit Corporation, 2010 Page 3 of 7

Installing and Removing 10Gig SFP Copper Cable Assemblies To attach a cable assembly, remove the purple protective EMI cap. Then simply insert the connector end into the cage of the SFP+ host port in the active equipment. Make sure the cable is fully inserted and engaged. ATTENTION: Observe precautions for handling electrostatic sensitive electronic devices when installing this product. Ensure that you are properly grounded with a wrist strap or equivalent while installing 10Gig SFP+ Copper Cables. To disengage, gently pull the latch release and the cable assembly will easily disengage the port. The Panduit 10Gig SFP+ Direct Attached Copper Cable Assemblies have been designed to fit into highdensity belly-to-belly faceplates. Panduit Corporation, 2010 Page 4 of 7

Cable Management The weight of large bundles of SFP+ twin-axial cables can exert a significant force along the horizontal plane, and specifically on the host port of the active equipment. If the cable emerges from the rear of the connector at too sharp an angle, excess mechanical stress may be transmitted both along the cable and into the circuit board located inside the connector. Excessive side forces exerted by the cable can also misalign the plug in the equipment-mounted receptacle. These forces may degrade performance or even possibly damage the connector and lead to failure. It is important to observe and maintain proper cable bend radius and equally important to provide adequate and secure strain relief on the cable. In order to help maintain proper bend, it is recommended to pre-form the strain relief bend on the cable before installing. The minimum recommended bend radius is 5X the cable outside diameter (O.D.) for a single time bend and 10X the OD for repeated bends. Minimum Bend Radius Guide Cable Wire Gauge O.D. Min. Bend Radius (r) AWG30 4.1 mm (0.16 in) 20.5 mm (0.80 in) AWG24 5.6 mm (0.22 in) 28 mm (1.10 in) r To help manage the weight of bundled cable and ensure they do not sag over time, a cable manager or strain relief bar should be installed to support SFP+ Copper Cable Assemblies and provide strain relief along the horizontal plane. Strain relief bars facilitate the correct alignment of cable and connector into the port, and help installers observe manufacturer and bend radius requirements of cable close to the connector. The strain relief bars also help keep cables routed clear from spaces directly behind server and switch equipment, reducing thermal resistance through the equipment and promote effective cooling and airflow. To ensure long-term reliability, it is recommended to use a rack with integral cable management features such as the Panduit Net-Access Cabinets. Tak-Ty Hook and Loop Cable Ties should be used to bundle the cables together and tie them to the strain relief bars and cable managers. This should be done carefully to ensure the cables are firmly in place and will not move, but not so tight as to deform or stress the cable jacketing. Cable Installation Tips and Best Practices There are a few practical steps that can be taken during installation to optimize the effectiveness of the layout. For overhead cable routing, place the switches near the top of the racks For under floor cable routing, place the switches near the bottom of the racks Do not route SFP+ Cable Assemblies parallel to power cables, they should only cross at right angles Do not route cables in front of fans or air ventilation areas of the rack Do not kink cables Do not twist connectors Use Tak-Ty Hook and Loop Cable Ties to secure cables, do not use plastic cable ties Slack Management Standard cables come in 1-meter (3.3 ft) increments. Often installers will standardize on a small number of standard lengths to simplify the bill of material. One cannot always anticipate possible infrastructure obstacles on site so it is good practice to estimate long when defining cable lengths. Therefore, it is possible that there will be cable slack and this needs to be managed properly to ensure reliable long term performance. The slack in the cable should be shaped and looped so as not to violate bend radius. Slack or loops should be securely tied in place so they do not slip or sag over time. Panduit Corporation, 2010 Page 5 of 7

General Deployment Topology Guidelines Within a single 84 inch 45 RU cabinet, conservatively the longest connection will be 7 ft or 2.1 meters to reach from the top U to the bottom and approximately 1.5 ft or 0.45 m to route to any port on either end. A 3 meter cable should be adequate to connect any two ports within a cabinet 84 inches = 7ft = 2.1 m Example cabinet with 2 top of rack switches (ToR) and 20 2U servers with Dual SFP+ NICs total of 40 SFP+ cables Conservatively, longest cable required to reach farthest port is 2.1 + 2.x 0.45 3m Example of 3 cabinet Pod with 40 2 RU servers distributed over 3 cabinets with 2 ToR switches in center cabinet requires 80 SFP+ cables with longest cable of 4m Example of 5 cabinet Pod with 80 2 RU servers distributed over 5 cabinets with 4 ToR switches in center cabinet requires 160 SFP+ cables with longest cable of 5m Panduit Corporation, 2010 Page 6 of 7

Using Middle of Row switching topology, an 8 cabinet row may be achieved with 7m cables. This has two switch cabinets in the center and 3 server cabinets on each side. If all switching were placed in a single center cabinet, a 9 cabinet row with 8 server cabinets may be covered. To enable longer row, fiber and SFP+ optical transceivers are required. A hybrid solution of Panduit 10Gig SFP+ copper for the inner cabinets and Panduit 10Gig OM3 fiber to the outer cabinets will be the cost effective solution. For Instructions in Local Languages and Technical Support: www.panduit.com/resources/install_maintain.asp www.panduit.com Page 7 of 7 E-mail: cs@panduit.com Fax: (708) 444-6993