Harmonic Reduction of Arc Furnaces Using D-Statcom

Similar documents
Investigation of D-Statcom Operation in Electric Distribution System

CHAPTER 6 UNIT VECTOR GENERATION FOR DETECTING VOLTAGE ANGLE

Comparison of Various Reference Current Generation Techniques for Performance Analysis of Shunt Active Power Filter using MATLAB Simulation

Voltage Flicker Mitigation in Electric Arc Furnace using D-STATCOM

Cascaded H-Bridge Five Level Inverter for Harmonics Mitigation and Reactive Power Control

INVESTIGATION OF HARMONIC DETECTION TECHNIQUES FOR SHUNT ACTIVE POWER FILTER

Modeling and Simulation of SRF and P-Q based Control DSTATCOM

Shunt Active Power Filter based on SRF theory and Hysteresis Band Current Controller under different Load conditions

Simulation and Comparison of DVR and DSTATCOM Used For Voltage Sag Mitigation at Distribution Side

SIMULATION OF D-STATCOM AND DVR IN POWER SYSTEMS

Mitigation of Flicker Sources & Power Quality Improvement by Using Cascaded Multi-Level Converter Based DSTATCOM

A Static Synchronous Compensator for Reactive Power Compensation under Distorted Mains Voltage Conditions

Modeling of Statcom. P.M. Sarma and Dr. S.V. Jaya Ram Kumar. Department of Electrical & Electronics Engineering GRIET, Hyderabad, India

Control Of Shunt Active Filter Based On Instantaneous Power Theory

HARMONIC ELIMINATION IN THREE PHASE SYSTEM BY MEANS OF A SHUNT ACTIVE FILTER

Power Quality Improvement using Shunt Passive Filter

CHAPTER 5 DESIGN OF DSTATCOM CONTROLLER FOR COMPENSATING UNBALANCES

Sinusoidal Current Control based Shunt Active Power Filter for Current Harmonics Reduction

PSPWM Control Strategy and SRF Method of Cascaded H-Bridge MLI based DSTATCOM for Enhancement of Power Quality

Power Control Scheme of D-Statcom

Design Strategy for Optimum Rating Selection of Interline D-STATCOM

ENHANCEMENT OF POWER QUALITY USING 9-LEVEL CASCADED H-BRIDGE BASED D-STATCOM WITH IRP THEORY SK. Meeravali* 1, Dr. K.

Synchronous Reference Frame Theory For Nonlinear Loads using Mat-lab Simulink

Space Vector PWM Voltage Source Inverter Fed to Permanent Magnet Synchronous Motor

5DESIGN PARAMETERS OF SHUNT ACTIVE FILTER FOR HARMONICS CURRENT MITIGATION

New Time Domain Electric Arc Furnace Model for Power Quality Study

Enhancement of Power Quality in Distribution System Using D-Statcom for Different Faults

Multi-Pulse Voltage Source Converter Statcom For Voltage Flicker Mitigation

IJSTE - International Journal of Science Technology & Engineering Volume 2 Issue 12 June 2016 ISSN (online): X

Power Quality enhancement of a distribution line with DSTATCOM

ABSTRACT I. INTRODUCTION

INSTANTANEOUS POWER CONTROL OF D-STATCOM FOR ENHANCEMENT OF THE STEADY-STATE PERFORMANCE

ISSN: ISO 9001:2008 Certified International Journal of Engineering Science and Innovative Technology (IJESIT) Volume 2, Issue 3, May 2013

Simulation And Comparison Of Space Vector Pulse Width Modulation For Three Phase Voltage Source Inverter

Mitigation of Line Current Harmonics Using Shunt Active Filter With Instantaneous Real and Reactive Power Theory

Comparison of Shunt Active Power Filter Control Strategies for Harmonic Compensation in a Paper Industrial Factory

Mitigation of voltage disturbances (Sag/Swell) utilizing dynamic voltage restorer (DVR)

Multi Level Inverter Based Active Power Filter for Harmonic Reduction

ISSN: Page 20. International Journal of Engineering Trends and Technology- Volume2Issue3-2011

A Novel Four Switch Three Phase Inverter Controlled by Different Modulation Techniques A Comparison

A Voltage Controlled D-STATCOM for Power Quality Improvement with DVR

Design and Simulation of Three Phase Shunt Active Power Filter Using SRF Theory

SIMULATION AND COMPARISON OF SPWM AND SVPWM CONTROL FOR TWO LEVEL UPQC

Application of Fuzzy Logic Controller in Shunt Active Power Filter

Improved Performance of STATIC Compensator for Grid Connected Wind System Using IRP Theory

Design and Simulation of DVR Used For Voltage Sag Mitigation at Distribution Side

Power Quality improvement of a three phase four wire system using UPQC

Vector Control of Three-Phase Active Front End Rectifier

A MATLAB-SIMULINK APPROACH TO SHUNT ACTIVE POWER FILTERS

Voltage Flicker Compensation using STATCOM to Improve Power Quality

Power Quality Improvement Using Hybrid Power Filter Based On Dual Instantaneous Reactive Power Theory With Hysteresis Current Controller

Current Control Technique for Three Phase Shunt Active Power Filter by Using Adaptive Hysteresis Current Controller

Performance of DVR under various Fault conditions in Electrical Distribution System

FUZZY CONTROLLED DSTATCOM FOR HARMONIC COMPENSATION

NEUTRAL CURRENT COMPENSATION USING FOUR LEG SHUNT ACTIVE POWER FILTER

ANALYSIS OF SYNCHRONOUS-REFERENCE-FRAME-BASED CONTROL METHOD FOR UPQC UNDER UNBALANCED AND DISTORTED LOAD CONDITIONS Salava Nagaraju* 1

Direct Power Control With Space Vector Modulation And Fuzzy DC- Voltage Control- PWM rectifier

MODELLING & SIMULATION OF ACTIVE SHUNT FILTER FOR COMPENSATION OF SYSTEM HARMONICS

Control of Shunt Active Power Filter for Improvement of Power Quality

ISSN: [Yadav* et al., 6(5): May, 2017] Impact Factor: 4.116

CHAPTER 3 COMBINED MULTIPULSE MULTILEVEL INVERTER BASED STATCOM

Harmonics Reduction of 3 Phase Diode Bridge Rectifier by Implementing P-Q Theory with Active Filter

Harmonics Elimination Using Shunt Active Filter

Enhancement of Power Quality in Distribution System Using D-Statcom

Devineni Gireesh Kumar Assistant Professor, M Tech, Department of Electrical and Electronics

Multilevel Inverter Based Statcom For Power System Load Balancing System

Chapter 2 Shunt Active Power Filter

A Five Level DSTATCOM for Compensation of Reactive Power and Harmonics

Simulation of Multi Converter Unified Power Quality Conditioner for Two Feeder Distribution System

Analysis the Modeling and Control of Integrated STATCOM System to Improve Power System

A Versatile Control Scheme for UPQC for Power Quality Improvement using fuzzy controller

Harmonics Reduction using 4-Leg Shunt Active Power Filters

Compare Stability Management in Power System Using 48- Pulse Inverter, D-STATCOM and Space Vector Modulation Based STATCOM

THD Minimization of a Cascaded Nine Level Inverter Using Sinusoidal PWM and Space Vector Modulation

[Mahagaonkar*, 4.(8): August, 2015] ISSN: (I2OR), Publication Impact Factor: 3.785

SPWM Switching Strategy for Compensation of Unbalanced and Non Linear Load Effects in Three Phase Four Wire System Using D-Statcom

Enhancement of Power Quality with Multifunctional D-STATCOM Operated under Stiff Source for Induction Motor Applications

IJSRD - International Journal for Scientific Research & Development Vol. 2, Issue 06, 2014 ISSN (online):

Analysis of Reference Current Generation for Shunt Active Power Filter Using SRF Algorithm to Compensate Harmonic Current


Kanuru; Krishna (Dt); A.P, India. DOI: / Page. 1 G. Aruna Jyothi, 2 DR. P. V. R. L.

Power Quality Analysis of Non- Linear Loads for Industrial Power System

IJESR/Nov 2012/ Volume-2/Issue-11/Article No-21/ ISSN International Journal of Engineering & Science Research

International Journal of Research (IJR) e-issn: , p- ISSN: X Volume 2, Issue 09, September 2015

PERFORMANCE OF DISTRIBUTION STATIC COMPENSATOR IN LOW VOLTAGE DISTRIBUTION SYSTEM

Power Quality Improvement of Non-Linear Load by Using Instantaneous P-Q Theory

PI-VPI Based Current Control Strategy to Improve the Performance of Shunt Active Power Filter

Implementation of SRF based Multilevel Shunt Active Filter for Harmonic Control

Load Compensation at a Reduced DC Link Voltage by Using DSTATCOM with Non-Stiff Source

Application of Distribution Static Synchronous Compensator in Electrical Distribution System

D-STATCOM FOR VOLTAGE SAG, VOLTAGE SWELL MITIGATION USING MATLAB SIMULINK

A DSTATCOM-Control Scheme for Power Quality Improvement of Grid Connected Wind Energy System for Balanced and Unbalanced Non linear Loads

REDUCTION OF THD IN POWER SYSTEMS USING STATCOM

STATCOM with FLC and Pi Controller for a Three-Phase SEIG Feeding Single-Phase Loads

A New Control Scheme for Power Quality Improvement with STATCOM

Mitigation of Voltage Sag/Swell Using UPQC

Design of SVPWM Based Inverter for Mitigation of Harmonics in Power System

Simulation Results of a Shunt Active Power Filter with Control Based on p-q Theory

Improvement of Power Quality in Distribution System using D-STATCOM With PI and PID Controller

ACTIVE COMPENSATION OF HARMONICS IN INDUSTRIAL APPLICATIONS. Sergej Kalaschnikow, Steffan Hansen, Lucian Asiminoaei, Henrik Gedde Moos

Transcription:

IOSR Journal of Engineering (IOSRJEN) e-issn: 5-31, p-issn: 78-8719 Vol. 3, Issue 4 (April. 13), V4 PP 7-14 S.Pushpavalli, A. CordeliaSumathy 1. PG Scholar, Francis Xavier Engineering College,Vannarpettai,Tirunelveli. Associate Professor, EEE Department, Francis Xavier Engineering College,Tirunelveli Abstract: Arc furnaces are used in industries for induction heating and welding. Due to the rapid growth of nonlinear loads, such as power electronic control equipments and Electric arc furnace (EAF) power quality problems such as harmonics and voltage flicker are introduced in the power system. It occurs because of the time-varying and non-linear behaviour of the electric arc furnace operation. Hence an Electric arc furnace model is needed to analyze the power quality. In this paper, a time domain model called hyperbolic model for electric arc furnace is analyzed using MATLAB. The model is used to study its behaviour on the power system using MATLAB. To improve the power quality D-STATCOM is proposed, in which the control strategies used are Direct, Indirect control and Hysteresis controller. Direct control technique uses P-Q theory in which transformation is based on orthogonal reference frame. Indirect control technique uses d-q theory in which transformation is based on synchronous reference frame. Hysteresis controller uses Hysteresis Bandwidth to produce the switching signals. Control strategies used in D-statcom are simulated using MATLAB/SIMULINK. I. INTRODUCTION Usage of EAF results in voltage fluctuation which leads to the reduction in electrical equipment efficiency, interference in protection systems and grid. Hence power quality problem become a major concern for both power companies and customers. To quantify the problems, D-STATCOM is used. Distributed Static Synchronous Compensator (DSTATCOM), which consists of an IGBT-based voltage source inverter, uses advanced power switches to provide fast response and flexible voltage control at the connection for power quality improvement in distribution systems. Advantages of D-STATCOM: 1. Flexible voltage control. Improvement in Power factor 3. Harmonic contents can be reduced 4. Fast response EAF is described in Section II. Section III comprises of D-statcom and its control strategy. Section IV describes the simulation results. Section V describes about the conclusion. II. ARC FURNACES Its structure resembles to that of two electrodes with a charge placed inside a heating chamber. When the air-gap between the electrodes is subjected to maximum voltage stress, contacts between them ionized to make the flow of current which results in the form of arc. Since the electrical arc is a nonlinear and time varying phenomenon, description of its behaviour in the time domain is easier than in the frequency domain. There are different numbers of models for EAF such as 1. Harmonic voltage source model. domain model 3. Frequency model domain model is proposed here. domain models can be classified into V-I Characteristic (VIC), and Equivalent Circuit Methods (ECM). Based on the V-I characteristic of arc furnace, which is derived from the relationship between arc voltage and arc current VIC method is used. This method is widely used for modelling the static and the dynamic operation of EAF. This paper proposes a new model named as Hyperbolic model of EAF in the time domain. The proposed model of EAF is explained with a good approximation without need of the initial conditions of the EAF[1]. Also, it is used to describe different operating situation of the EAF and power system. The accuracy of the load model is increased by establishing random and sinusoidal noises to have a new model. An EAF flicker model based on a hyperbolic model is simulated in the first part. In the second part, the DSTATCOM with direct and indirect control is simulated. 7 P a g e

Hyperbolic Model: Basically there are two models such as Static and Dynamic model. Simulation of arc is the important issue in the modelling of EAF. There are several methods used to describe the electric arc. Here, Hyperbolic model of EAF is discussed and simulated in the first part [4] and D-statcom with indirect,direct,hysteresis control is proposed and simulated. The below figure (Fig.1) represents the VI characteristics of EAF and actual linear piecewise model [1,, 3 and 5]. But the Hyperbolic model discussed is a non-linear one and is modelled according to equation (.1) & (.). VI Characetristics of EAF Fig.1 For static model the VIC of the EAF is considered to be in the form of V=V (i) and it can described as: V(i)=V at +(C/D)+i (.1) Where, V - arc voltage, i - arc current per phase. V at - threshold magnitude. V at is the magnitude of threshold voltage to which the voltage approaches as current increases. Its value depends on the arc length which is defined by constants C and D which are of arc power and arc current respectively. Dynamic EAF model is required for real time analysis of the effect of the arc. The dynamic arc characteristic is simulated by varying arc conductance. In general, the variation is of random nature. Two types of variation are considered for the studysinusoidal and random. In order to study the effect of voltage flicker on the system of EAF, Vat is varied sinusoidally and randomly. In this regard Vat is modulated as follows: The sinusoidal variation is assumed as: V at (t) = V at [1+m.sin(ω f t)] (.) Where, m is modulation index and ω f is a flicker frequency. For random flicker generation V at is modulated with a random signal with the mean of zero. Thus V at is written as: V at (t)=v at [1+m.N(t)] (.3) where, N(t) is a band limited white noise with zero mean and variance of one. Problems of EAF: Due to the usage of EAF, it creates problems as follows: 1. Harmonics. Fluctuations 3. Flickering 4. Low power factor Hence the other loads connected also gets affected and also the source voltage. Hence EAF is considered to be the main cause of power quality degradation. Therefore we have to find a solution to improve power quality because at the load point production process gets more complicated and requirement of a bigger reliability level will occur. Hence we have to avoid this by providing energy without interruptions, without harmonic distortion and keeping the voltage in a very narrow margin. The devices which can fulfil these requirements are the Custom Power devices among wihch D-statcom is proposed here. III..PROPOSED METHOD: IEEE defines Static Synchronous Generators as self-commutated switching power converters supplied from an appropriate electric energy source and operated to produce a set of adjustable multiphase voltages, which may be coupled to an ac power system for the purpose of exchanging independently controllable real and reactive power. D-STATCOM compensates by generating or absorbing reactive power by using power electronic switching converters. However, in STATCOM systems, the reactive power is determined by the switching converter part and reactive power can be kept constant irrespective of the supply voltage fluctuations. STATCOM systems are used in distribution and transmission systems for different purposes. STATCOMs are used in transmission systems to control reactive power and to supply voltage support to buses. STATCOM is 8 P a g e

Utility AC AC Isabc PCC Ilabc Ilabc Isabc Arc Furnace Vdc + - Vdc installed in distribution systems or near the loads to improve power factor and voltage regulation. This type of STATCOM is called D-STATCOM. DSTATCOM (Distributed static Synchronous compensator) is the proposed model to improve the power quality[]. Multifunctions preformed by D-statcom are: regulation and compensation of reactive power; Correction of power factor and Elimination of current harmonics. Here, such a device is employed to provide continuous voltage regulation using an indirectly controlled converter[3]. Single diagram of D-statcom is shown in Fig3.1 Single diagram of D-statcom - Fig3.1 Description of the proposed system: The main circuit of the DSTATCOM system with Arc Furnace load connected to 3-phase, 3-wire distribution system together with the measurements needed by the control system is shown in Fig.(3.). The Arc Furnace is modelled as a Hyperbolic model. Under operation without D-statcom, EAF results in fluctuating load currents and voltage fluctuation at PCC. To compensate the fluctuating load currents and to mitigate it, algorithms based upon Indirect control (d-q theory), Direct control (P-Q theory) [5], Hysteresis Controller is proposed. [IL]abc Electric Magnetic Interface [Vs]abc S1 S3 S5 S S4 S6 [Iref]abc Control System [Vs]abc Main Circuit of DSTATCOM with EAF load Fig. (3.) Compensation strategies: A.Direct control of EAF using D-statcom: Instantaneous reactive power theory (P-Q theory): P-Q theory transforms the three phase system of voltages and currents from phase co-ordinates to -αβ coordinates by means of Clark-Concordia transformation, which is represented by the following matrix equation (3.1) and (3.). V V V β = 3 I I Iβ = 3 1 1 1 1 1 1 3 3 1 1 1 1 1 1 3 3 V a V b V c (3.1) I a Ib Ic (3.) In the case of three-phase three-wire systems V o = and i o =. In the new co-ordinate system using stationary orthogonal reference frame theory, the instantaneous real and imaginary powers are expressed by the following matrix equation (3.3) & (3.4), which finally allows expression of currents as a function of the power quantities. 9 P a g e

p q = V V β I V β V α Iβ (3.3) I 1 V V β p Iβ = V +V β V β V α q (3.4) The control algorithm based on pq theory compensation is outlined here under. The three phase source voltages [V sa,v sb,v sc ] are transformed to stationary orthogonal reference frame variables [V sα,v sβ ]. Reference currents (i α *, i β *) are evaluated based on equation (3.4) by using V sα,v sβ and p ref and q ref. The instantaneous active power (p ref ) for maintaining dc link voltage constant is obtained by comparing actual dc link voltage with a preset value and by processing the error voltage through a PI controller. The instantaneous reactive power reference (q ref ) is set to zero. With the evaluated reference currents in orthogonal frame, the actual source currents in the same frame are compared and processed through PI controllers and reference voltages are obtained in stationary frame which are transformed to abc frame using Clark s reverse transformation for generating gate pulses for the IGBT based voltage source inverter. B. Indirect control of EAF using D-Statcom: Synchronous reference frame theory: (d-qtheory) The synchronous reference theory is based on the transformation of the stationary reference frame three phase variables (a,b,c) to synchronous reference frame variables(d,q,o ) whose direct (d)and quadrature (q) axes rotate in space at the synchronous speed e. e is the angular electrical speed of the rotating magnetic field of the three phase supply, given by e =πf s, where f s is the frequency of the supply. If θ is the transformation angle, then the current transformation from abc to d-q- frame is defined as in the following equations: I d Iq I = 3 cos θ cos θ π 3 sin θ sin θ π 3 1 1 cos θ + π 3 sin θ + π 3 1 I a I b Ic (3.5) C. Hysteresis Controller: Using this control, rapid switching of each switch is done by using the comparison of the measurement of D-Statcom current with the reference current. Basic principle behind this is to produce the switching signals by using the comparison of error signal with the fixed value of hysteresis bandwidth. Advantages: Simple Technique Robust Fast Response Good stability Generation of Switching signals using Hysteresis controller: Reference current signals are generated by using d-q transformation. Here the three phase current variables are transformed into synchronous reference frame to synchronize the ac main voltage with the reference frame variables. The above transformation is done by converting the three phase supply variables into d-q variable by using the matrix equation (3.5) I d Iq I = 3 cos θ cos θ π 3 sin θ sin θ π 3 1 1 cos θ + π 3 sin θ + π 3 1 I a I b Ic (3.5) Reference currents produced by transformation are compared with the D-Statcom current which gives the output as error signal. This signal is compared with the hysteresis bandwidth [6] to generate the switching signals. Tolerable bandwidth is taken as + % of reference value of current. Upper switch of that leg will be turned ON, but the lower switches will be in OFF condition when the value of the phase current exceeds the 1 P a g e

Mag (% of Fundamental) Current Current upper bandwidth. Reverse operation will take place when the phase current value falls below the lower bandwidth. IV. SIMULATION RESULTS This deals about the simulation results and THD comparison for different controls of D-Statcom. Simulated THD output was tabulated and viewed in bar chart Fig. 4.1 shows the EAF voltage and current. Fig 4. shows the source output voltage and current without D-statcom. Fig. 4.3 shows the THD output without D- statcom. Fig 4.4 shows the output of source output voltage and current with Direct control of D-statcom. Fig 4.5 shows the THD output of direct control using D-statcom. Fig 4.6 and Fig.4.7shows the instantaneous active and reactive power with direct control of d-statcom. Fig. 4.8 shows the source output voltage and current using Indirect control of D-statcom. Fig 4.9 shows the THD output of Indirect control of D-statcom. Fig 4.1 and Fig.4.11 shows the instantaneous active and reactive power with Indirect control of d-statcom. Fig 4.1 shows the output of source output voltage and current with Hysteresis controller of D-statcom. Fig 4.13 shows the THD output of Hysteresis control using D-statcom. Fig 4.14 and Fig.4.15 shows the instantaneous active and reactive power with Hysteresis controller of d-statcom. 4 and Current Output of EAF -.1..3.4.5.6.7.8.9 1 1 and Current Output of EAF -1 - -3.1..3.4.5.6.7.8.9 1 3 Phase Eaf And Current Output- Fig (4.1) 5 Source Output and Current without D-Statcom -5.5.1.15..5.3.35.4.45.5 1-1 - -3.5.1.15..5.3.35.4.45.5 3 Phase Source Output Without D-Statcom- Fig 4. 5 15 1 5 Output Without D-Statcom Fundamental (5Hz) =.1473, THD= 1.64% 1 3 4 5 6 7 8 9 1 Harmonic order Thd Output Without D-Statcom- Fig 4.3 11 P a g e

Current Active Power 8 6 4 - -4-6 Current Mag (% of Fundamental) -8.5.1.15..5.3.35.4.45.5 Mag (% of Fundamental) Instantaneous Active Power with pq theory using D-Statcom 5 Source output and Current with D-Statcom using pq theory -5.5.1.15..5.3.35.4.45.5 4 -.5.1.15..5.3.35.4.45.5 3 Phase Source Output With Direct Control Of D-Statcom- Fig 4.4 Fundamental (5Hz) = 1.14, THD= 1.7% 3 1 1 3 4 5 6 7 8 9 Harmonic order Thd Output With Direct Control Of D-Statcom - Fig 4.5 1 x 16 Instantaneous Active Power Output With Direct Control Of D-Statcom Fig 4.6 x 16 Instantaneous Reactive Power with pq theory using D-Statcom - -4-6 -8-1 -1-14 -16.5.1.15..5.3.35.4.45.5 Instantaneous Reactive Power Output With Direct Control Of D-Statcom Fig 4.7 5 Source output voltage and current with D-statcom using d-q theory -5.5.1.15..5.3.35.4.45.5 - Selected signal: 5 cycles. FFT window (in red): 1 cycles -4.5.1.15..5.3.35.4.45.5-3 Phase Source Output With Indirect Control Of D-Statcom - Fig 4.8.5.1.15..5.3.35.4.45.5 (s) Fundamental (5Hz) =.365, THD= 1.9% 4 3 1 1 3 4 5 6 7 8 9 Harmonic order Thd Output With Indirect Control Of D-Statcom - Fig 4.9 1 P a g e

Mag (% of Fundamental) Current 16 x 14 Instantaneous Active Power Output using dq theory of D-Statcom 14 1 1 8 6 4.5.1.15..5.3.35.4.45.5 Instantaneous Active Power Output With Indirect Control Of D-Statcom Fig 4.1 -.8 x 15 Instantaneous Reactive Power Output using dq theory of D-Statcom -1-1. -1.4-1.6-1.8 - -..5.1.15..5.3.35.4.45.5 Instantaneous Reactive Power Output With Indirect Control Of D-Statcom Fig 4.11 5 Source output voltage & current using Hysteresis Controller of D-Statcom -5.5.1.15..5.3.35.4.45.5 - -4.5.1.15..5.3.35.4.45.5 3 Phase Source Output With Hysteresis Controller Of D-Statcom- Fig 4.1 Fundamental (5Hz) =.4, THD=.5% 5 4 3 1 1 3 4 5 6 7 8 9 Harmonic order Thd Output With Hysteresis Controller Of D-Statcom - Fig 4.13 16 x 14 Instantaneous Active power using Hysteresis Controller of D-statcom 14 1 1 8 6 4..4.6.8 1 1. 1.4 1.6 1.8 Instantaneous Active Power Output With Hysteresis Controller Of D-Statcom Fig 4.14 -.8 x 15 Instantaneous Reactive Power Output using Hysteresis controller of D-Statcom -1-1. -1.4-1.6-1.8 - -...4.6.8 1 1. 1.4 1.6 1.8 Instantaneous Reactive Power Output With Hysteresis Controller Of D-Statcom Fig 4.15 13 P a g e

V. CONCLUSION Electric Arc furnace used in industries is concluded as one of the major power quality degradation. Compensation technique provided with the Direct, Indirect control and Hysteresis controller of D-Statcom is discussed here. In this, D-STATCOM controller is derived by using orthogonal reference frame theory, synchronous reference frame theory and Hysteresis controller. The model is simulated using Matlab simulink and D-STATCOM controller s performance is evaluated using Direct, Indirect and Hysteresis control for Total Harmonic Distortion. All the controllers are proven to be effective with improved response. From the results obtained for Total Harmonic Distortion, Hysteresis control of D-statcom is the best one. Future scope is to simulate the D-statcom with the different control technique to have further reduction in harmonics for the new model of EAF. REFERENCES [1]. K.Anuradha, B.P.Muni Modeling of Electric Arc Furnace & Control Algorithms for voltage flicker mitigation using DSTATCOM, IEEE 9 []. Y. Najafi Sarem, M. H. Amrollahi, M. Babanejad, Sh. Mounesirad & M. Abbasi Layegh and Davood habibinia, Electric Arc Furnace Power Modeling for STATCOM Controller Application, International Symposium on Power Electronics,Electrical Drives, Automation and Motion 1 [3]. A. Alzate, A. Escobar, J. J. Marulanda, Application of a D-STATCOM to Mitigate Arc Furnaces Power Quality Problems, I EEE Trondheim Power Tech, 11. [4]. C. Bhonsle, R.B. Kelkar, Simulation of Electric Arc Furnace Characteristics for Flicker study using MATLAB, International Conference on Recent Advancements in Electrical, Electronics and Control Engineering, 11 [5]. M.NagaRaju, Dr.K.Anuradha, Dr. G. R. K. Murthy, A.Santha Kumari, flicker mitigation by DSTATCOM for voltage source Arc furnace model IEEE 11 [6]. Genzhong, Combined hysteresis current-controlled PWM inverter and robust control for a permanentmagnet synchronous motor, IEEE 11 [7]. NareshK.Kumari, Comparitive Evaluation of D-statcom Control Algorithms for Load compensation,ieee 1 14 P a g e