Signal-to-Noise Ratio (SNR) discussion

Similar documents
SNR IMPROVEMENT FOR MONOCHROME DETECTOR USING BINNING

Detailed Scientific Barrier Filter Discussion

Improving the Collection Efficiency of Raman Scattering

Hyperspectral goes to UAV and thermal

PhysicsAndMathsTutor.com 1

A collection of hyperspectral images for imaging systems research Torbjørn Skauli a,b, Joyce Farrell *a

GUIDE TO SELECTING HYPERSPECTRAL INSTRUMENTS

BASLER A601f / A602f

Preliminary Characterization Results: Fiber-Coupled, Multi-channel, Hyperspectral Spectrographs

Reikan FoCal Aperture Sharpness Test Report

OPAL Optical Profiling of the Atmospheric Limb

Benchtop System Quick Start

Reikan FoCal Aperture Sharpness Test Report

LASP / University of Colorado

Photons and solid state detection

Reikan FoCal Aperture Sharpness Test Report

Name: Date: Math in Special Effects: Try Other Challenges. Student Handout

Reikan FoCal Aperture Sharpness Test Report

What Makes Push-broom Hyperspectral Imaging Advantageous for Art Applications. Timo Hyvärinen SPECIM, Spectral Imaging Ltd Oulu Finland

Camera Test Protocol. Introduction TABLE OF CONTENTS. Camera Test Protocol Technical Note Technical Note

Chapter 17: Wave Optics. What is Light? The Models of Light 1/11/13

White Paper on SWIR Camera Test The New Swux Unit Austin Richards, FLIR Chris Durell, Joe Jablonski, Labsphere Martin Hübner, Hensoldt.

Infrared Illumination for Time-of-Flight Applications

Exam 4. Name: Class: Date: Multiple Choice Identify the choice that best completes the statement or answers the question.

GRENOUILLE.

DESIGN NOTE: DIFFRACTION EFFECTS

Sharpness, Resolution and Interpolation

Criteria for Optical Systems: Optical Path Difference How do we determine the quality of a lens system? Several criteria used in optical design

High Speed Hyperspectral Chemical Imaging

Observational Astronomy

Remote Sensing Calibration Solutions

IMAGE SENSOR SOLUTIONS. KAC-96-1/5" Lens Kit. KODAK KAC-96-1/5" Lens Kit. for use with the KODAK CMOS Image Sensors. November 2004 Revision 2

Multispectral. imaging device. ADVANCED LIGHT ANALYSIS by. Most accurate homogeneity MeasureMent of spectral radiance. UMasterMS1 & UMasterMS2

Advanced Camera and Image Sensor Technology. Steve Kinney Imaging Professional Camera Link Chairman

Variable microinspection system. system125

Single Slit Diffraction

e2v Launches New Onyx 1.3M for Premium Performance in Low Light Conditions

Ground Truth for Calibrating Optical Imagery to Reflectance

Back-illuminated scientific CMOS camera. Datasheet

Basler aca km. Camera Specification. Measurement protocol using the EMVA Standard 1288 Document Number: BD Version: 03

LSST All-Sky IR Camera Cloud Monitoring Test Results

Basler aca gm. Camera Specification. Measurement protocol using the EMVA Standard 1288 Document Number: BD Version: 01

Spectral Analysis of the LUND/DMI Earthshine Telescope and Filters

Point Spread Function Estimation Tool, Alpha Version. A Plugin for ImageJ

Basler aca640-90gm. Camera Specification. Measurement protocol using the EMVA Standard 1288 Document Number: BD Version: 02

Technical Notes. Integrating Sphere Measurement Part II: Calibration. Introduction. Calibration

BTS2048-UV. Product tags: UV, Spectral Data, LED Binning, Industrial Applications, LED.

Resampling in hyperspectral cameras as an alternative to correcting keystone in hardware, with focus on benefits for optical design and data quality

Color Measurement with the LSS-100P

Solid State Luminance Standards

CHAPTER 6 Exposure Time Calculations

The Hyperspectral UAV (HyUAV) a novel UAV-based spectroscopy tool for environmental monitoring

Supplementary Materials

Wide Field-of-View Fluorescence Imaging of Coral Reefs

Spectroscopy Lab 2. Reading Your text books. Look under spectra, spectrometer, diffraction.

Exercise 8: Interference and diffraction

Digital Camera Technologies for Scientific Bio-Imaging. Part 2: Sampling and Signal

Acquisition. Some slides from: Yung-Yu Chuang (DigiVfx) Jan Neumann, Pat Hanrahan, Alexei Efros

Radiometric Use of WorldView-3 Imagery. Technical Note. 1 WorldView-3 Instrument. 1.1 WorldView-3 Relative Radiance Response

ECEN. Spectroscopy. Lab 8. copy. constituents HOMEWORK PR. Figure. 1. Layout of. of the

Radiometric and Photometric Measurements with TAOS PhotoSensors

High Resolution BSI Scientific CMOS

Improved Spectra with a Schmidt-Czerny-Turner Spectrograph

GPI INSTRUMENT PAGES

PHY385H1F Introductory Optics. Practicals Session 7 Studying for Test 2

BTS2048-BS. Product tags: VIS, Spectral Data, Industrial Applications, Laser.

Chapter 5 Nadir looking UV measurement.

Reikan FoCal Aperture Sharpness Test Report

DEFENSE APPLICATIONS IN HYPERSPECTRAL REMOTE SENSING

NOTES/ALERTS. Boosting Sensitivity

Introduction to Remote Sensing. Electromagnetic Energy. Data From Wave Phenomena. Electromagnetic Radiation (EMR) Electromagnetic Energy

Basler ral km. Camera Specification. Measurement protocol using the EMVA Standard 1288 Document Number: BD Version: 01

Image acquisition. In both cases, the digital sensing element is one of the following: Line array Area array. Single sensor

Hyperspectral Imager for Coastal Ocean (HICO)

UltraGraph Optics Design

Lecture Notes 10 Image Sensor Optics. Imaging optics. Pixel optics. Microlens

WHITE PAPER. Guide to CCD-Based Imaging Colorimeters

OCT Spectrometer Design Understanding roll-off to achieve the clearest images

Measuring intensity in watts rather than lumens

Camera Calibration Certificate No: DMC III 27542

Welcome to: LMBR Imaging Workshop. Imaging Fundamentals Mike Meade, Photometrics

Norsk Elektro Optikk AS (NEO) HySpex Airborne Sensors System Overview

ISS-30-VA. Product tags: Integrating Sphere Source. Gigahertz-Optik GmbH 1/5

MUSKY: Multispectral UV Sky camera. Valentina Caricato, Andrea Egidi, Marco Pisani and Massimo Zucco, INRIM

Radiometric Solar Telescope (RaST) The case for a Radiometric Solar Imager,

Camera Selection Criteria. Richard Crisp May 25, 2011

HYPERSPECTRAL NIR CAMERA. Technical Note, ver by Morten Arngren

DOING PHYSICS WITH MATLAB COMPUTATIONAL OPTICS. GUI Simulation Diffraction: Focused Beams and Resolution for a lens system

The Importance of Wavelengths on Optical Designs

panda family ultra compact scmos cameras

Diffraction. Interference with more than 2 beams. Diffraction gratings. Diffraction by an aperture. Diffraction of a laser beam

PIKA SERIES IMAGING SPECTROMETERS AND SPECTRONON SOFTWARE

EE-527: MicroFabrication

CCDs for Earth Observation James Endicott 1 st September th UK China Workshop on Space Science and Technology, Milton Keynes, UK

WHITE PAPER MINIATURIZED HYPERSPECTRAL CAMERA FOR THE INFRARED MOLECULAR FINGERPRINT REGION

Digital camera. Sensor. Memory card. Circuit board

DECISION NUMBER FOURTEEN TO THE TREATY ON OPEN SKIES

Application Note (A13)

Hyperspectral Sensor

Opto Engineering S.r.l.

Transcription:

Signal-to-Noise Ratio (SNR) discussion The signal-to-noise ratio (SNR) is a commonly requested parameter for hyperspectral imagers. This note is written to provide a description of the factors that affect SNR. We begin by examining the signal collected by a hyperspectral imager, Φ(λ), in units of Joules, collected by each detector element (which is a unique spatial and spectral channel), and is calculated to a good approximation using the formula: Φ(λ) = πl(λ)a Dε(λ)(Δλ)(Δt) 4(f #) 2 + 1 Each factor in this equation is discussed below: L(λ) is the at-sensor spectral radiance at wavelength λ in units of W/(m 2 sr nm). In layman s terms, this tells you the brightness of the light coming into the imager. If you have very bright light, your signal will increase as you would expect. Thus, in general, you can increase your signal (and thus your SNR) with brighter illumination. Generally, the illumination changes with wavelength. For example the solar spectrum in typical atmospheric conditions is shown below. Note that illumination becomes weaker at both short (~4 nm) and long wavelengths, and thus the signal (and SNR) degrade at short and long wavelengths. Solar Radiance.35 [W/m 2 nm sr)].3.25.2.15.1.5. 4 6 8 1 12 14 16 Solar Radiance in typical atmospheric conditions.

AD is the detector area in m 2. This is the area of each pixel on the camera. Large pixelarea increases your signal. Large pixel-area increases your signal, and pixel-binning effectively increases the pixel-area. Because it is very complicated and expensive to integrate new cameras, this is usually not a parameter that can be adjusted. ε(λ) is the optical system efficiency which includes optical throughput of the lenses, the diffraction grating efficiency, and the detector quantum efficiency. The grating and detector efficiencies both change significantly with wavelength and as a result the SNR of an imaging spectrometer is strongly wavelength dependent. efficiency 1..9.8.7.6 Pika L Hyperspectral Imaging Camera grating efficiency sensor efficiency total efficiency.5.4.3.2.1. Grating, sensor, and total efficiencies of the Pika L hyperspectral camera as a function of wavelength. Δλ is the optical bandwidth in nm spread out across each pixel. Δt is the integration time (also known as the shutter time and exposure time ) in seconds. This is one of the easiest parameters to adjust. The MAXIMUM integration time is 1/(frame rate). Thus, to increase the signal (and SNR), do the following: (1) Decrease the frame rate; and (2) then increase the integration time. (f/#) is the imaging lens f-number, which is a measure of the instrument s aperture. For maximum signal (and best SNR), the f/# on the objective lens should be set to the f/# of

the instrument. There is no benefit to setting the f/# lower than instrument s value. A higher f/# setting on the objective lens will provide a deeper depth of field. The smallest acceptable f/# s for the Pika imaging spectrometers are: Pika Model f/# Pika II (discontinued Jan 216) 3. Pika L 2.4 Pika XC2 2.4 Pika NIR 1.8 Once the Signal is known, the signal-to-noise ratio as a function of wavelength, SNR(λ), is calculate using the following equation: SNR(λ) = Φ(λ) λ hc [Φ(λ) λ hc ] + [B(i 2 Dark) t] + [B(e Read )] where h is Plank s constant, c is the speed of light, B is the number of binning operations performed to collect the signal, i Dark is the dark current in electrons per second, and e Read is the read noise in electrons. The nomenclature for the terms is as follows: the numerator is the signal in units of electrons. The denominator is the noise in units of electrons, whose terms, going from left to right, are shot noise, dark noise, and read noise. Shot noise is noise in the signal itself and cannot be avoided. For the short integration times of most applications with Pika imaging spectrometers, dark noise is insignificant. Read noise is dependent on temperature, the sensor, and other factors, but for Resonon s hyperspectral cameras it is fairly small, typically less than 2 electrons. The maximum possible SNR is dependent on the sensor s well depth, dark noise, read noise, and binning. These maximum possible SNR values are listed in the table below. Pika Model Maximum SNR Pika II (discontinued Jan 216) 198 Pika L 347 Pika XC2 361 Pika NIR 1936 When you combine all the factors above, one can generate a plot of the Signal-to-Noise Ratio (SNR). However, because it is dependent on ALL the factors listed above, one

must be careful to note how the results change in differing conditions. For example, halogen lighting will produce a different SNR than solar lighting; high frame rates will lead to lower SNRs than slow frame rates, and so forth. Below are shown typical SNR plots for Resonon s hyperspectral cameras in solar illumination and with an integration time such that the brightest channel has a 95% fill factor. 6 SNR, Pika L, solar illumination 5 4 3 2 1 Pika L SNR as a function of wavelength with typical solar illumination.

6 SNR, Pika XC2, solar illumination 5 4 3 2 1 Pika XC2 SNR as a function of wavelength with typical solar illumination. 2 SNR, Pika NIR, solar illumination 15 1 5 9 1 11 12 13 14 15 16 17 Pika NIR SNR as a function of wavelength with typical solar illumination.

Note that the prominent dips in the SNR plots are due to features in the solar spectrum. Optical SNR are often provided in units of decibels (db), which is given as: SNR db = 2 log 1 (SNR(λ)) SNRdB plots for the Pika L, Pika XC2, and Pika NIR for the same conditions in the SNR plots above are provided below. 6 SNR db, Pika L, solar illumination 6 SNR db, Pika XC2, solar illumination 5 5 4 4 3 3 2 2 1 1 7 SNR db, Pika NIR, solar illumination 6 5 4 3 2 1 9 1 11 12 13 14 15 16 17

Noise Equivalent Spectral Radiance (NESR) Another noise metric is the Noise Equivalent Spectral Radiance (NESR). This is the spectral radiance required to obtain a SNR of 1. As one would expect, this is dependent on the internal optical efficiency of the instrument it will be large for spectral channels where efficiency is relatively poor and small where efficiency is good. The NESR can be found by setting the equation for SNR equal to 1 and then solving for L(λ) : NESR(λ) = 1 + 1 + 4(Bi dark(δt) + Be read ) 2Q(λ) where Q(λ) = πa Dε(λ)(Δλ)(Δt) 4(f/#) 2 + 1 λ hc Graphs showing the NESR of Resonon s hyperspectral imagers are below. mw/(m 2 nm sr).6 Pika L NESR binning = 2.5.4.3.2.1.

.6.5.4 NESR, binning = 2 NESR, binning = 3 NESR, binning = 4 Pika XC2 NESR sunlight.3.2.1. W / (m 2 nm sr).12 Pika NIR NESR.1.8.6.4.2. 9 1 11 12 13 14 15 16 17