INDEPENDENT TEST LABORATORY REPORT No

INDEPENDENT TEST LABORATORY REPORT No

INDEPENDENT TEST LABORATORY REPORT No

INDEPENDENT TEST LABORATORY REPORT No

INDEPENDENT TEST LABORATORY REPORT No

TEST REPORT. Job No SHA Date: Apr 12,2017 REPORT NO SHA-006. TEST OF ONE LED Luminaire MODEL NO.

Revolution Lighting 4139 Guardian St. Simi Valley CA 93063

8165 E Kaiser Blvd. Anaheim, CA p f NVLAP LAB CODE

Model No Stock No Calibration Due Date Chroma Programmable AC Source PS-AC02

Revolution Lighting Technologies 4139 Guardian Street, Simi Valley, CA 93063

NVLAP LAB CODE:

TEST REPORT. Job No SHA Date: February 19, 2017 REPORT NO SHA-003

REVOLUTION LIGHTING TECHNOLOGIES INC

LM Test Report. for. Philips (China) Investment Co., Ltd. InstantFit LEDtube Model:

Report No.: HZ k/R1. (Lumens) Stabilization Time CRI (K) (Light & Power) Table 1: Executive Data Summary

LM Test Report. for Maxlite SK America Inc. 2*4 Retrofit Kits Model: RKT4514U5550DV

IESNA LM79: 2008 Photometric Test Report

NVLAP LAB CODE:

LM Test Report. for Elec-Tech International Co.,Ltd. LED CEILING LIGHT Model: XX(XX: 01-10)

LM Test Report. for Elec-Tech International Co.,Ltd. LED CEILING LIGHT Model: XX(XX: 61-70)

NVLAP LAB CODE:

LM Test Report. for Elec-Tech International Co.,Ltd. LED CEILING LIGHT Model: XX(XX: 01-10)

LM Test Report. for Elec-Tech International Co.,Ltd. LED PAR30 Spot light Model: XX(XX:41-50)

57-100W-XXK-WPH12-SG W-40K-WPH12-SG W-57K-WPH12-SG

NVLAP LAB CODE LM Test Report. For. MaxLite Inc. (Brand Name: MaxLite) 12 York Ave West Caldwell NJ 07006

Report No.: HZ f. Total Luminous Flux (Lumens) Stabilization Time (Light & Power) Table 1: Executive Data Summary CRI

Number Eight Lighting Company MPT2-HI-R-6-BK/15/DIM1-M-1000

NVLAP LAB CODE LM Test Report. For. Maxlite INC. (Brand Name: Maxlite) 12 York Ave., West Caldwell, NJ 07006

NVLAP LAB CODE LM Test Report. For. Maxlite Inc. (Brand Name: ) 12 York Avenue, West Caldwell, NJ

NVLAP LAB CODE:

IESNA LM79: 2008 Photometric Test Report

LM Test Report. for Maxlite SK America Inc. WALLPACK Model: MLSWP30LED50DS

NVLAP LAB CODE:

NVLAP LAB CODE:

IESNA LM79: 2008 Photometric Test Report

(Lumens) Stabilization Time CRI (K) (Light & Power) Table 1 Executive Data Summary

IESNA LM79: 2008 Photometric Test Report

Revolution Lighting Technologies 4139 Guardian Street, Simi Valley, CA No seasoning was performed in accordance with IESNA LM-79.

Revolution Lighting Technologies 4139 Guardian Street, Simi Valley, CA No seasoning was performed in accordance with IESNA LM-79.

71332 LED Dusk To Dawn (Area Light)

Calibration Due Date Chroma Programmable AC Source 61604

8165 E Kaiser Blvd. Anaheim, CA p f NVLAP LAB CODE MAXLITE 12 York Ave. West Caldwell, NJ.

Report No.: HZ j. Total Luminous Flux (Lumens) Stabilization Time (Light & Power) Table 1: Executive Data Summary CRI

Report No.: HZ b. Total Luminous Flux (Lumens) Stabilization Time (Light & Power) Table 1: Executive Data Summary CRI

LM Test Report. For KEYSTONE TECHNOLOGIES LLC. (Brand Name: KEYSTONE) 1390 Welsh Road North Wales, PA 19454

NVLAP LAB CODE LM Test Report. For MAXLITE INC. (Brand Name: MAXLED) 12 York Avenue West Caldwell, NJ

LM Test Report. For. Revolution Lighting Technologies, Inc. (Brand Name: ) 2280 Ward Ave. Simi Valley, CA

Diogen Lighting,Inc 14 Inverness Drive East,Ste.E-128 Englewood, CO T8L W BEST Test Service Shenzhen Co., Ltd.

Eternal Shine Technology Co.,Ltd. EST

LM Test Report. For FALKOR INDUSTRY INC. (Brand Name: Falkor Lighting) 5580 Bandini Blvd Bell,CA USA

NVLAP LAB CODE LM Test Report. For GREEN INOVA LIGHTING TECHNOLOGY (SHENZHEN) LTD. (Brand Name: GI LED LIGHTING)

Report No.: HZ c/R1. Total Luminous Flux (Lumens) Stabilization Time (Light & Power) Table 1: Executive Data Summary CRI

8165 E Kaiser Blvd. Anaheim, CA p f NVLAP LAB CODE

Model No Stock No Calibration Due Date Chroma Programmable AC Source PS-AC02

Report No.: HZ c

LM Test Report. For. GREEN LOGIC LED ELECTRICAL SUPPLY INC (Brand Name: GLLUSA) Shenfubao Industry Park, Bonded area, Futian District,Shenzhen

Report No.: HZ h/R1. Total Luminous Flux (Lumens) Stabilization Time (Light & Power) Table 1: Executive Data Summary CRI

LM Test Report. For. Builders Pack. ShenFuBao Industry Park,Bonded area,futian District,Shenzhen,China

Equipment Used Model No Stock No Calibration Due Date

ISOFOOTCANDLE LINES OF HORIZONTAL ILLUMINATION

ISOFOOTCANDLE LINES OF HORIZONTAL ILLUMINATION

(Lumens) Stabilization Time CRI (K) (Light & Power) Table 1 Executive Data Summary

LM Test Report. for Elec-Tech International Co., Ltd. BR40 LAMP Model: XX(XX:01-10), WBR40L27S2A

LM Test Report. For. Eternal Shine Technology Co.,Ltd. (Brand Name: EST) ShenFuBao Industry Park,Bonded area,futian District,Shenzhen,China

LM Test Report. for Maxlite Inc. LED Canopy Model: MLCAN20LED50

IESNA LM-79: Measurement and Test Report for Jiawei Technology (USA) Limited Lincoln Ave.Hayward, CA USA.

Client submitted the sample. Catalog number is LRH240U. Received in working and undamaged condition. No modifications were necessary.

Report No.: HZ a. 60 mins Note. 4000K, frosted lens Table 1: Executive Data Summary

NVLAP LAB CODE LM Test Report. For. LED2 Lighting Group, Inc. (Brand Name: LED2) 600 Minnesota Ave, Kansas City, KS 66101

NVLAP LAB CODE LM Test Report. For. LED2 Lighting Group, Inc. (Brand Name: LED2) 600 Minnesota Ave, Kansas City, KS 66101

NVLAP LAB CODE LM Test Report. For. LED Waves, Inc st. Ave. Brooklyn, NY USA. Linear Retrofit Kits for 2x2 Luminaires

Report No.: HZ a/R2. Total Luminous Flux (Lumens) Stabilization Time (Light & Power) Table 1: Executive Data Summary CRI

Report No.: HZ h. Total Luminous Flux (Lumens) Stabilization Time (Light & Power) Table 1: Executive Data Summary CRI

Photometric Test Report

Report No.: HZ d

LM Test Report. For. Eternal Shine Technology Co.,Ltd. (Brand Name: EST) ShenFuBao Industry Park,Bonded area,futian District,Shenzhen,China

NVLAP LAB CODE LM Test Report. For MAXLITE,INC. (Brand Name: N/A) 12 YORK AVENUE WEST CALDWELL,NJ 07006

IESNA LM-79: Measurement and Test Report for EiKO Global, LLC. Sep 09, 2013 LED8WMR16/38/830-DIM. David Zhang BTR

Report No.: HZ a/R2. Total Luminous Flux (Lumens) Stabilization Time (Light & Power) Table 1: Executive Data Summary CRI

IESNA LM-79: Measurement and Test Report for Green Creative Ltd. Room , New Victory House, Wing Lok Street, Central, HONG KONG

LM Test Report. For. Builders Pack. ShenFuBao Industry Park,Bonded area,futian District,Shenzhen,China

IESNA LM79: 2008 Photometric Test Report

8165 E Kaiser Blvd. Anaheim, CA p f NVLAP LAB CODE

Test Sample Description Catalog Number: Description:

LM Test Report. For FALKOR INDUSTRY INC. (Brand Name: Falkor Lighting) 5580 Bandini Blvd Bell,CA USA

8165 E Kaiser Blvd. Anaheim, CA p f NVLAP LAB CODE

IESNA LM79: 2008 Photometric Test Report

BARTCO Lighting 5761 Research Drive, Huntington Beach, CA 92649

8165 E Kaiser Blvd. Anaheim, CA p f NVLAP LAB CODE

LED14.5WPAR30S/FL/827-DIM

LM Test. for LED. Cabinet

NVLAP LAB CODE LM Test Report. For ATG ELECTRONICS CORP. (Brand Name: N/A) th Street Rancho Cucamonga, CA 91730

LM-79 Test Report. Electrical and Photometric tests as required by IESNA LM-79 test standard

Approved Method: Electrical and Photometric. Measurements of Solid-State Lighting Products

NVLAP LAB CODE LM Test Report. For. Hocan Group Co.,Ltd. Rm 1902, Easey Comm Bldg Hennessy Rd Wanchai, HONG KONG

IESNA LM-79: Measurement and Test Report for Halco Lighting Technologies ATL 2940-A PACIFIC DRIVE. Dec 08, 2014

USTE, dba Vista Professional Outdoor Lighting Surveyor Ave., Simi Valley CA 93063

NVLAP LAB CODE LM Test Report. Outdoor Non-Cutoff and Semi-Cutoff Wall-mounted Area Luminaires. Model name(s): WML-50W

LM Test Report. for EiKO Global, LLC. 25W Floodlight Model: FLM-2C-N-U

Transcription:

Lighting Sciences, Inc. Color and Photometric Testing, According to IESNA LM 79 Standards and Procedures, Test Report Files for: Par 30, 9W, DWF, Dimmable, 120V, Glass (SKU #180064) Seesmart 4139 Guardian Street Simi Valley, CA 93063 Tel: 877.578.2536 Fax: 888.239.0959 Web: www.seesmartled.com

Lighting Sciences www.lightingsciences.com Lighting Sciences Inc. 7826 E. Evans Road Scottsdale, Arizona 85260 USA Tel: 480-991-9260 Fax: 480-991-0375 INTENSITY(CANDLEPOWER) SUMMARY ANGLE MEAN CP LMS. ANGLE MEAN CP LMS. 0 232 90 5 5 230 22 95 4 4 10 225 100 3 15 219 61 105 2 2 20 209 110 1 25 198 91 115 1 1 30 184 120 0 35 166 103 125 0 0 40 145 130 0 45 122 94 135 0 0 50 99 140 0 55 77 69 145 0 0 60 57 150 0 65 40 40 155 0 0 70 28 160 0 75 18 20 165 0 0 80 12 170 0 85 8 9 175 0 0 90 5 180 0 ZONAL LUMENS AND PERCENTAGES ZONE LUMENS % LUMINAIRE 0-30 174 33.76 0-40 278 53.71 0-60 440 85.23 0-90 510 98.64 40-90 232 44.92 60-90 69 13.41 90-180 7 1.36 0-180 517 100.00 EFFICACY (LUMENS PER WATT): 53.8 *** THIS IS AN ABSOLUTE TEST *** S/MH: 1.2 SC: 1.2 CERTIFIED BY: PREPARED FOR: SEESMART LED SIMI VALLEY, CA DATE: SEP 30, 2010 TESTED IN ACCORDANCE WITH IES PROCEDURES.

INTENSITY(CANDLEPOWER) DATA ANGLE INTENSITY LUMENS (CANDLEPOWER) 0 232 5 230 22 10 225 15 219 61 20 209 25 198 91 30 184 35 166 103 40 145 45 122 94 50 99 55 77 69 60 57 65 40 40 70 28 75 18 20 80 12 85 8 9 90 5 95 4 4 100 3 105 2 2 110 1 115 1 1 120 0 125 0 0 130 0 135 0 0 140 0 145 0 0 150 0 155 0 0 160 0 165 0 0 170 0 175 0 0 180 0

COEFFICIENTS OF UTILIZATION ZONAL CAVITY METHOD EFFECTIVE FLOOR CAVITY REFLECTANCE =.20 CC 90 80 70 50 30 10 0 WALL 70 50 30 10 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0 RCR 0 1.221.221.221.22 1.191.191.191.19 1.161.161.161.16 1.101.101.10 1.051.051.05 1.011.011.01 0.99 1 1.131.081.051.01 1.101.061.030.99 1.071.041.010.97 0.990.970.94 0.950.930.91 0.920.900.88 0.86 2 1.040.970.910.85 1.020.950.890.84 0.990.930.880.83 0.890.850.81 0.860.820.79 0.830.800.77 0.75 3 0.970.870.790.73 0.940.850.780.73 0.920.840.770.72 0.810.750.71 0.780.730.69 0.750.710.68 0.66 4 0.890.780.700.64 0.870.770.690.63 0.850.750.690.63 0.730.670.62 0.700.650.61 0.680.640.60 0.58 5 0.830.700.620.55 0.800.690.610.55 0.780.680.600.54 0.650.590.54 0.630.580.53 0.620.570.52 0.51 6 0.770.630.550.49 0.750.620.540.48 0.730.610.540.48 0.590.530.48 0.580.520.47 0.560.510.46 0.45 7 0.700.570.490.43 0.690.560.480.43 0.670.560.480.42 0.540.470.42 0.520.460.42 0.510.460.41 0.39 8 0.650.520.430.38 0.640.510.430.37 0.620.500.430.37 0.490.420.37 0.470.410.37 0.460.410.36 0.34 9 0.600.470.380.33 0.590.460.380.33 0.570.450.380.33 0.440.370.32 0.430.370.32 0.420.360.32 0.30 10 0.560.430.340.29 0.550.420.340.29 0.530.410.340.29 0.400.330.29 0.390.330.28 0.380.320.28 0.27 THE ABOVE COEFFICIENTS HAVE BEEN CALCULATED BASED ON LUMINAIRE LUMENS BECAUSE IN AN ABSOLUTE TEST THE BARE LAMP LUMENS ARE UNKNOWN. LIGHTING DESIGN CALCULATIONS MADE USING THESE COEFFICIENTS SHOULD THEREFORE USE THE LUMINAIRE LUMENS IN THE CALCULATION FORMULA LUMINAIRE INPUT WATTS 9.6 LABORATORY RESULTS MAY NOT BE REPRESENTATIVE OF FIELD PERFORMANCE. BALLAST AND FIELD FACTORS HAVE NOT BEEN APPLIED. TEST DISTANCE EXCEEDS FIVE TIMES THE GREATEST LUMINOUS OPENING OF LUMINAIRE.

ELECTRICAL MEASUREMENTS INPUT VOLTAGE: 120.0 VOLTS AC INPUT CURRENT: 0.082 AMPS INPUT POWER: 9.6 WATTS POWER FACTOR: 97.6 PERCENT TOTAL HARMONIC DISTORTION: 15.00 PERCENT OFF STATE POWER: 0.00 WATTS LIGHT OUTPUT LUMENS: EFFICACY: 517 lm 53.8 lm/w SPECTRAL MEASUREMENTS X: 0.3050 y: 0.3145 u/u': 0.1979 v: 0.3061 v': 0.4592 Duv: 0.0003 CRI(R a ): 79.9 CRI(R 9 ): 6.1 CCT: 7108 K RADIANT FLUX: 1758 mw

SIDE VIEW BOTTOM VIEW All testing was conducted in accordance with LM-79-08, Approved Method: Electrical and Photometric Measurements of Solid-State Lighting Products as published by the Illuminating Engineering Society of North America (IESNA). The condition of the item tested was new. Stabilization time before testing exceeded 16 hours. The test results (luminous distribution and flux) were obtained by using a Lighting Sciences series 6000 Type C Moving Mirror Goniophotometer The photometric reference standard used is a set of three incandescent luminous intensity standard lamps calibrated and traceable to the U.S. National Institute of Standards and Technology. The test results (colorimetric and luminous flux) were obtained by using a Lighting Sciences model 4000 Integrating Sphere of either 1 or 2 meters diameter, having an internal reflectance exceeding 0.80. 4π geometry was used. Correction factors were applied for spectral mismatch and selfabsorption. The spectroradiometer employed was a LSC model 500E having a bandwidth of.84. The photometric reference standard used is a set of three incandescent luminous flux standard lamps calibrated and traceable to the U.S. National Institute of Standards and Technology. The colorimetric reference standard used is an incandescent spectral standard lamp calibrated and traceable to the U.S. National Institute of Standards and Technology. Power measurements were obtained with a Yokogawa WT210 power analyzer. Ambient temperature during testing was 25 C ± 1 C, measured using an Omega model DP460. Calibration certificates are on file at the laboratories of Lighting Sciences Inc.