LANGER EMV-TECHNIK. Operating Instructions. A 100 / A 200 / A 300 Optical Fibre Probe

Similar documents
D10 Demonstration Board

NEAR FIELD MEASURING MEASURING SET-UP. LANGER E M V - T e c h n i k

P331-2 set ESD generator (IEC )

P603-1 / P750 set. RF conducted measurement IEC

Schlöder GmbH - EMC Test and Measurement Systems Model #

Electromagnetic compatibility Guidance and manufacturer s declaration DIN EN :2007 (IEC :2007)

EMC in the railway environment Hans Bängtsson

TEST REPORT... 1 CONTENT...

Voltage Transient Emission Test

EMC Seminar Series All about EMC Testing and Measurement Seminar 1

Power supply CP-D 12/2.1

Coupling- / Decoupling Network. 150 khz 300 MHz. 150 khz 230 MHz. 10 khz 230 MHz. IEC and CISPR 15 / CISPR 22 IEC

Power supply CP-D 24/1.3

2620 Modular Measurement and Control System

An Introduction to EMC Testing (what can be done with scopes) Vincent Lascoste EMC Product Manager - RSF

Power supply CP-D 24/4.2 Primary switch mode power supply

TETRIS 1000 High Impedance Active Probe. Instruction Manual

D C 01/2019 3

9 Specifications. Specifications NOMINAL CHARACTERISTICS

EN61326 EMC COMPLIANCE REPORT on the LP Series Ultrasonic Transmitter Remote Amplifier and Transducer for Hawk Measurement Systems Pty Ltd

EMC/EMI MEASURING INSTRUMENTS & ACCESSORIES SHORT-FORM CATALOG 2011

LS200 TEST DATA IEC61000 SERIES

RADIATED IMMUNITY TEST SYSTEM 6 GHz

Power supply CP-E 24/2.5

Immunity development system E 1

REK 510 Current injection device for earth-fault protection of a synchronous machine rotor. User s Manual

T22. Torque transducer. Special features. Data sheet

Group: Names: (1) In this step you will examine the effects of AC coupling of an oscilloscope.

Power supply CP-E 24/20.0

EMC/EMI MEASURING INSTRUMENTS & ACCESSORIES SHORT-FORM CATALOG 2009

Overview of EMC Regulations and Testing. Prof. Tzong-Lin Wu Department of Electrical Engineering National Taiwan University

Guidance and Declaration - Electromagnetic Compatibility (EMC) for the Delfi PTS ii Portable Tourniquet System

Vert-X 22E - 5V / PWM. Applications Wind vanes Valve control Level sensor Special purpose vehicles

IF30. User's manual. Description. Table of contents IF30

FlexRay Communications System. Physical Layer Common mode Choke EMC Evaluation Specification. Version 2.1

EMC TEST REPORT For MPP SOLAR INC Inverter/ Charger Model Number : PIP 4048HS

PD30CNB25xxPS. Photoelectrics, Background suppression reflective - PointSpot. Main features. Main functions. Description

By order of American Power Conversion Holdings Inc. at New Taipei City, Taiwan

T10FS. Data Sheet. Torque Flange. Special features. Installation example T10FS. B en

500 ma DC-DC Step Down Converter P78G-Series

Vert-X 22E - 24V / 4-20mA. Applications Wind vanes Valve control Level sensor Special purpose vehicles

MedRx Avant Polar HIT AH-I-MPHITS-5 Effective 11/07/11

Nuclear Associates

T10F. Data Sheet. Torque Flange. Special features. Installation example T10F. B en

Coupling/Decoupling Networks (CDN)

Vert-X 22E - 5V / % Ub. Applications Wind vanes Valve control Level sensor Special purpose vehicles

Vert-X 27E - 24V / SPI. Applications Harvesting machine Fork lift Hydraulic pump

NOVOHALL Rotary Sensor touchless technology transmissive. Series RFC4800 analog

BIODEX MULTI- JOINT SYSTEM

EN 55022: 2010+AC:2011 Clause 6.1 Pass. Harmonic Current EN :2006+A1:2009+A2:2009 Class A N/A

T22. Data Sheet. Torque transducer. Special features. Installation example with two bellows couplings. B en

Contents. ZT530PCI & PXI Specifications. Arbitrary Waveform Generator. 16-bit, 400 MS/s, 2 Ch

EMC test report AU01+E04

Power supply CP-E 24/2.5

Vert-X 27E - 24V / 4-20mA. Applications Harvesting machine Fork lift Hydraulic pump

EMC Test Report. Report Number: M030826

DTE Power via MDI Task Force P802.3af

50W Constant Current (700mA) Dimming LED Driver

Immunity Test System RIS 3000 / RIS 6000 acc. to IEC/EN

Radiated immunity test system 6 GHz

Radiated Immunity Test System 6 GHz

Harmonizing the ANSI-C12.1(2008) EMC Tests. Harmonizing the ANSI-C12.1(2008) EMC Tests

EN :2007+A1:2011 Electromagnetic compatibility Emission standard for residential, commercial and light-industrial environments

High precision measurement system for current and voltage IHC-A/B-RM01/03

HAL , 508, 509, HAL Hall Effect Sensor Family

V1.3. TBLC08 50mH AC-LISN TBLC08

T40FM. Data Sheet. Torque flange. Special features. Overall concept. B en

Power supply CP-E 24/0.75

No. 1. BROADBAND RF-POWER-AMPLIFIERS 10 khz - 6 GHz. For immunity tests according to IEC, EN, ISO, SAE, MIL

NOVOHALL Rotary Sensor non-contacting. Series RSC2800 digital SSI, SPI, Incremental

ASK Cards. Features Analog signal isolation Digital signal isolation. Applications

Electrical FOR:

Datasheet. messtechnik gmbh. Torque ranges from 0,5 to 1000 Nm. Features. Extra Features DRBK-A. Torque Transducer DRBK + DRBK-A

ELECTRIC FIELD PROBE ANTENNA MODEL PEF-10A. 20 Hz 1 MHz

AMPLIFIER RESEARCH... APPLICATION NOTE: 23

Vert-X 27E - 5V / % Ub. Applications Harvesting machine Fork lift Hydraulic pump

1. Electro-Static Discharge Test EN R Radiated Susceptibility Test EN R-2

Vert-X 37E - 5V / % Ub. Applications Agricultural machines Construction machines Forest machines Special purpose vehicles

Advanced Test Equipment Rentals ATEC (2832)

Ordercode Output Power Output 1 Output 2 Output 3 PCB-mounting Chassis mounting max. with solder pins with screw terminals

SGM9111 8MHz Rail-to-Rail Composite Video Driver with 6dB Gain

Accredited calibration of field strength meters

NOVOHALL Rotary Sensor non-contacting. Series RSC2800 analog

Power supply CP-E 12/10.0 Primary switch mode power supply Data sheet

NOVOHALL Rotary Sensor non-contacting. Series RSC-2800

EMC standards. Presented by: Karim Loukil & Kaïs Siala

ADC5000 SERIES. AC/DC Switch Mode Power Supplies and Rectifiers for Industrial and Telecom Applications. 60W, 125W and 250 W

Prof. dr. ir. Johan CATRYSSE

Certificate of Test AND KEEPS ALL REQUIREMENTS ACCORDING THE FOLLOWING REGULATIONS IEC :2001 IEC :2007

GTEM For emission and immunity testing according to IEC/EN Introduction

TMT Series, 10 to 50 Watt. Order Code Output Power Output 1 PCB-Mount Chassis Mount max.

Power supply CP-T 24/20.0 Primary switch mode power supply

EMC Testing Report. Dual-120CS. Yuan Hsun Electric Co., Ltd.

Torque Sensor DML 500 S080S10X

MINI-PS AC/2X15DC/1

INDEX. 1. Electrostatic discharge immunity test E-1 ~ 2 (IEC )

Bulk Current Injection instead of Radiated immunity testing, in the range from 1 MHz upto 1 GHz: Measuring results

INSTALLATION MANUAL. Model: Smart Analyzer Manufacturer: Smart Impulse. Power meter with consumption breakdown by use 03/12/13

BROADBAND LINEAR AMPLIFIER Model P150

ELEC 0017: ELECTROMAGNETIC COMPATIBILITY LABORATORY SESSIONS

Transcription:

LANGER EMV-TECHNIK Operating Instructions A 100 / A 200 / A 300 Optical Fibre Probe Contents: Page 1. Usage 2 2. Function 4 3. Operation 4 4. Safety instructions 5 5. Technical data 6 6. Scope of delivery 7 Copyright (C) Dipl.- Ing. Gunter Langer Nöthnitzer Hang 31 01728 Bannewitz 17.01.2000 Voltage measurement and oscillographic signal tracing in devices and installations under extreme electromagnetic conditions. A100-200-300_0213be

2 1. Usage Measurement under interference conditions Measurement of analogue electrical signals under extreme electromagnetic stress such as: Coupling of radiated or conducted RF emissions Fast transients burst / ESD High potential (high voltage) EMC tests as the main field of application: Radiated RF emissions EN 61000-4-3: 80 MHz-1 GHz, 80 % AM (1 khz), anechoic chambers TEM cells stripline, Conducted RF emissions EN 61000-4-6: 40 V eff, 150 khz-230 MHz, 80 % AM (1 khz) Burst EN 61000-4-4 ESD EN 61000-4-2 Measured signals: Supply voltages (switching controllers, linear controllers), Reference voltages, Digital signals (optical couplers, optical receivers), Analogue signals (operational amplifiers, ADC, DAC). Specific measuring task Analogue electronic modules are generally influenced in EMC tests when RF modulated by 1 khz is applied to the EUT. This influence is due to the fact that the infiltrated RF disturbance is demodulated at PN junctions of the electronic circuit. Signal level fluctuations or 1 khz disturbance signals are generated. The 1 khz disturbance signal is produced through modulation of the RF disturbance by 1 khz. Relatively slow disturbance signals with a fundamental wave of 1 khz which mostly interfere with analogue circuits are characteristic for RF disturbance coupling. Figures 1 to 6 show examples of useful signals that were subjected to disturbances. The deviation of the signal form from the sine wave varies, i.e. the disturbance signal also contains a harmonic component beside the fundamental one. The measuring task is to correctly measure these relatively slow disturbance signals under extreme RF interference conditions. The A 100 / A 200/ A300 measuring systems are ideal for these conditions thanks to its high disturbance immunity. Specific measurement technology: To measure analogue signals under extreme interference conditions, measurement technology is needed that a) itself is not affected by disturbance fields and thus does not simulate any disturbance in the equipment under test (EUT). b) can be connected to the EUT in a decoupled way, i.e. connecting the probe head does not result in the development of additional disturbance current paths via which disturbances can penetrate or be discharged. The A 100 / A 200 A 300 optical fibre measurement system meets these demands.

3 Examples of disturbed useful signals Measured with the AS 100 probe. Radiated RF emissions: 250 MHz, 80 % amplitude-modulated by 1 khz EUT: operational amplifier circuit; RF coupling via an operational amplifier input; the disturbance signal was measured on the output. Figure 1: The oscillogram shows a constant useful signal with a demodulated 1 khz component. Figure 2: The demodulated 1 khz disturbance signal superimposed on the useful signal shows a large harmonic component. Figure 3: The demodulated 1 khz disturbance signal is limited by the lower rail. Figure 4: Useful signal without interference Figure 5: Useful signal with 1 khz disturbance signal Figure 6: Useful signal with 1 khz disturbance signal limited by the upper rail

4 2. Function 2.1. Method of measurement An RF-immune probe (sensor AS XXX), essentially consisting of an A/D converter (ADC) with a serial output, is autonomously operated in the EUT without interfering with the EUT's EMC conditions. The only connection between the AS XXX probe and the environment is an optical fibre that routes the measured values that are continuously generated by the ADC as a serial data flow to an optical receiver. A D/A converter (DAC) converts the digital sampling values back into an analogue signal that can be evaluated by an oscilloscope. 2.3. AE XXX DAC receiver An optical receiver converts the optical fibre signal to a serial data signal. A sequential logic systems synchronizes the receiver and controls the serial-parallel conversion of the measured values and the digital-to-analogconversion. Operational amplifiers are connected to the DAC output to filter and adjust the control ranges for the measuring ranges. 3. Operation 3.1. Connection of the probe (example AS 100) to the EUT Figure 7: Optical fibre measuring system 2.2. AS XXX ADC probe (sensor) The voltage that is applied to input E of the AS XXX probe (sensor) is converted to a serial data flow by an ananalog-to-digital-converter. The variable measurement voltage divider generates the control ranges: AS 100 50 / 10 VDC AS 110 10 / 1 VDC AS 120 1 / 0,1 VAC AS 200 50 / 10 VDC AS 300 ±10 VDC In the sensor AS 120 a capacitive coupled amplifier is integrated with a low cut-off frequency about 300 Hz. The sensor is protected against polarity reversal. Figure 8: AS100 pin assignment The connection between the optical fibre probe and the EUT has to be extremely short to ensure satisfactory measurements under radiated RF interference conditions, burst and ESD. Common prods and clips are too big. The optical-fibre probe has to be soldered directly to the module via a socket to ensure the requisite small scale set-up. Thanks to the socket the optical-fibre probe is not subjected to soldering itself. The measuring point can be quickly changed by plugging the probe into other sockets. Glue the socket to the circuit board or IC of the EUT. Connect the socket to the EUT via a CuL wire according to the sensor's pin assignment. Power supply is via the EUT or a battery.

5 Pay attention to the following to avoid measuring errors: Position the AS XXX close by the EUT's GND areas. Solder the socket directly to the line to be measured with short connecting wires (10...20 mm). Power should be taken from the immediate signal environment via the pins or block capacitor of the relevant IC. Connect the GND of the socket and the GND of the module via a short connection (10...20 mm) when power is supplied by a battery. Position a block capacitor (approx. 100 nf) at the connecting point. Connect the AE XXX to the oscilloscope (BNC plug). The receiver output supplies a zero-delay voltage of 10 V independent of the measuring range that is selected on the AS XXX. The vertical deflection on the oscilloscope should thus be 0.5-2 V/div. Connect the power supply to AE XXX (plugin power supply unit) lower LED "ON must be on. Connect Sensor and receiver by the optical fibre upper LED "Sync must be on. Loosen the clamped joint on receiver, insert the optical fibre up to the stop, slightly fasten the screwed joint. Basic rule: The closer the sensor with its housing and GND connection is positioned to the GND system of the EUT the higher its disturbance immunity and the fewer disturbances occur. Figure 10: AE 200 connectors and displays The oscilloscope must show an output voltage and/or signal form that corresponds to that applied to the sensor input. Figure 9: AS 100 is connected to the EUT; position the AS 100 on the IC package if there isn't enough free space above GND 3.2. Starting the AE XXX optical receiver 4. Safety instructions Do not use damaged or defective devices. Observe the operating and safety instructions for the respective disturbance source that is used (burst generator, RF power amplifier, sending aerial etc.). Only personnel who are qualified in the field of EMC may use the device under interference conditions. Only connect and disconnect a AS XXX sensor when it is not subjected to any interference..

6 5. Technical data 5.1. System System A 100 A 200 A 300 Resolution 12 Bit 12 Bit 10 Bit Conversion rate 125 ksps 3 Msps 12,5 Msps Bandwidth 25 khz 500 khz 5 MHz Transfer rate (optical fibre) 4 Mbps 48 Mbps 150 Mbps Operating range (optical fibre) 1 20 m * * The device is delivered with an optical fibre of 1.5 m 1 cannel or 6 m 2 cannels Please order other dimensions separately. 5.2. Sensors Sensor type AS 100 AS 110 AS 120 AS 200 AS 300 Measuring range, switchable 50 V / 10 VDC 10 V / 1 VDC 1 V / 0,1 VAC 300Hz 25kHz 50 V / 10 VDC ±10 VDC Input resistance 100 k 1 M 1 M 100 k 100 k Radiated immunity* >200 V/m >100 V/m >100 V/m >100 V/m 200 V/m Current consumption ca. 3 ma ca. 30 ma 70 30 ma Operating voltage 3-16 V 4,5-16 V Dimensions Operating temperature range (36x12,5x7,5) mm 0 70 C * Connectors 20 mm, on GND area, disturbances at output < 50 mv 5.3. Receivers Receiver type AE 100 AE 200 AE 300 Current consumption ca. 30 ma ca. 100 ma 90 ma Operating voltage 12-16 V 12 V Output voltage 0-10 V ±1 V Dimensions Operating temperature range (71x47x14) mm 0 70 C

7 6. Scope of delivery 6.1. A 100-1 / A 200-1 / A 300-1 (1-channel) set Pos. Designation Type Quantity --------------------------------------------------------------------------------------------------------------------------------- 01 Optical receiver (DAC) AE 100 / 200 / 300 1 02 Analogue sensor (ADC), of choice* AS XXX 1 03 Plug-in power supply unit 12 V / 300 ma 1 04 Optical fibre 1.5 m 1 05 Adapter socket 3-pole 3 06 Enamelled Cu wire 0.2 mm 34 m reel 1 07 Transport case with foam insert (240x185x50) mm 1 08 Short description Laminate 1 09 Operating instructions 1 * Further sensors are available on request and can be added to the set. ---------------------------------------------------------------------------------------------------------------------------------

8 6.2. A 100-2 / A 200-2 / A 300-2 (2-channels) set Pos. Designation Type Quantity --------------------------------------------------------------------------------------------------------------------------------- 01 Optical receiver (DAC) AE 100 / 200 / 300 2 02 Analogue sensor (ADC), of choice AS XXX 2 03 Plug-in power supply unit 12 V / 300 ma 1 04 Power split cable 20 cm 1 05 Optical fibre 6 m 2 06 Adapter socket 3-pole 6 07 Enamelled Cu wire 0.2 mm 34 m reel 1 08 Transport case with foam insert (340x260x55) mm 1 09 Short description Laminate 1 10 Operating instructions 1 * Further sensors are available on request and can be added to the set. --------------------------------------------------------------------------------------------------------------------------------- LANGER Nöthnitzer Hang 31 Tel.: +49(0)351/430093-0 EMV-Technik GmbH DE-01728 Bannewitz Fax: +49(0)351/430093-22 www.langer-emv.com mail@langer-emv.de