EDDYCON C FOR AIRCRAFTS TESTING. CE MARKING

Similar documents
EDDYCON C AIRCRAFT SET OF EDDY CURRENT FLAW DETECTOR FOR AIRCRAFTS TESTING. CE MARKING

PORTABLE EDDY CURRENT FLAW DETECTOR VD3-81 EDDYCON

PORTABLE EDDY CURRENT FLAW DETECTOR

PORTABLE EDDY CURRENT FLAW DETECTOR VD3-71 NK-IVU.

PORTABLE EDDY CURRENT FLAW DETECTOR VD3-71 NK-IVU.

MULTI-CHANNEL EDDY CURRENT FLAW DETECTOR VD-ОКО-01.

MULTI CHANNEL EDDY CURRENT FLAW DETECTOR EDDYCON D

New portable eddy current flaw detector and application examples

Eddy current flaw detector «Eddycon C»

VD3-71 universal eddy current flaw detector application for field inspection of aeronautical engineering

ULTRASONIC FLAW DETECTOR +TOFD VERSION. CE MARKING EN Compliant

UNIVERSAL ULTRASONIC FLAW DETECTOR UD4-76. TOFD version.

MULTI-CHANNEL ULTRASONIC FLAW DETECTOR ОКО-22М-UT THE BEST INDUSTRIAL OEM SOLUTION FOR IN-LINE AND IN-SERVICE SYSTEMS

NON-DESTRUCTIVE. Ukraine, Kiev, 8 Naberezhno-Lugova Str. tel./fax: (26) OKO ASSOCIATION

Testing Critical Medical Tubing Using High Frequency Eddy Current Coils

DETECTION OF THE SUBSURFACE CRACKS PROPAGATED FROM RIVET HOLES IN THE MULTILAYER AIRCRAFT STRUCTURES

Heat Exchanger & Boiler Tube Inspection Techniques

GE Inspection Technologies. Eddy Current Probes and Accessories Catalogue

INTRODUCTION. Strong Performance: High resolution and penetration, achieving precise flaw detection

MultiScan MS Tube Inspection System. Multi-technology System Eddy Current Magnetic Flux Leakage Remote Field IRIS Ultrasound

MultiScan MS Tube Inspection System. Multi-technology System Eddy Current Magnetic Flux Leakage Remote Field IRIS Ultrasound

Predator Probe Theory and Operation

Array Eddy Current for Fatigue Crack Detection of Aircraft Skin Structures

NDT Supply.com 7952 Nieman Road Lenexa, KS USA

Eddy Current Array for Aerospace

AA&S Conference 2018 Eddy Current Array for Aircraft

The Application of TOFD Technique on the Large Pressure Vessel

Application of Ultrasonic Guided Wave to Heat Exchanger Tubes Inspection

S. GURESH 4 JAN 2017 S. JOHNSON 4 JAN 2017

FLAW DETECTION USING ENCIRCLING COIL EDDY CURRENT SYSTEMS

ELECTROMAGNETIC ON-LINE TESTING OF ROLLED PRODUCTS AND TUBES. PROBLEMS AND SOLUTIONS.

FERROUS TUBING PROBES

Eddy Current Array Probe Catalog Aerospace Maintenance and Manufacturing Component Testing Automotive Manufacturing

AFRL-RX-WP-TP

Flexible PCB-Based Eddy Current Array Probes for the Inspection of Turbine Components

MAGNETOSCOP Measurement of magnetic field strengths in the range 0.1 nanotesla to 1 millitesla

Eddy Current Modelling for Fasteners Inspection in Aeronautic

DEEP PENETRATING EDDY CURRENT for DETECTING VOIDS in COPPER

Fastener Hole Crack Detection Using Adjustable Slide Probes

Digital Ultrasonic Flaw Detector

Basic functions of the universal flaw detector GEKKO

Digital Ultrasonic Flaw Detector

HANDHELD TESTERS FOR SUPERIOR FLAW DETECTION AND FASTER AIRCRAFT INSPECTIONS

D DAVID PUBLISHING. Eddy Current Test for Detection of Foreign Material using Rotating Probe. 2. Theory. 1. Introduction

Spectrum Analyzers 2680 Series Features & benefits

A Novel Self Calibrating Pulsed Eddy Current Probe for Defect Detection in Pipework

FreeSpace DS 16F VA TECHNICAL DATA SHEET. loudspeaker. Key Features. Product Overview. Technical Specifications

Magnetic Eddy Current (MEC) Inspection Technique

Enhancement of Technical Parameters of Eddy-Current Flaw Detectors Designed for Lengthy Metal Products On-Line Examination

ClampOn, Inc. Ultrasonic Intelligent Sensors. Presented by Hans A. Wagner

HZJF-9007 Fully Functional Partial Discharge Inspector USER MANUAL. Huazheng Electric Manufacturing(Baoding) Co.,Ltd

FCC CLASS B COMPLIANCE REPORT (DoC)

Generation Laser Scanning Method for Visualizing Ultrasonic Waves Propagating on a 3-D Object

Modelling of Pulsed Eddy Current Testing of wall thinning of carbon steel pipes through insulation and cladding

INVESTIGATION OF IMPACT DAMAGE OF CARBON FIBER- RAINFORCED PLASTIC (CFRP) BY EDDY CURRENT NON- DESTRUCTIVE TESTING

warwick.ac.uk/lib-publications

SGD-EGC200 «SKAT II» GEOPHYSICAL MULTI-FUNCTION TRANSMITTER

EVOLUTION OF THE CRYOGENIC EDDY CURRENT MICROPROBE

A SOLUTION TO THE PERMEABILITY AND LIFT-OFF PROBLEMS IN ELECTROMAGNETIC FLAW DETECTION

General information on NKD - 019E «UltraSonic»

The Battle of Carbon Steel

Effect of fatigue crack orientation on the sensitivity of eddy current inspection in martensitic stainless steels

TRAINING MANUAL. Part INTRODUCTION TO TWIST DRILLS

Detection, identification and sizing of plane defects with time-of- flight diffraction technique (TOFD) application in manual flaw detectors.

Exposure Level Tester ELT-400

Angle Encoder Modules

Multivariate Regression Algorithm for ID Pit Sizing

DEVELOPMENT OF VERY LOW FREQUENCY SELF-NULLING PROBE FOR INSPECTION OF THICK LAYERED ALUMINUM STRUCTURES

MultiScan MS 5800 Series

SEMS SHIELDING EFFECTIVENESS MEASUREMENT SYSTEM IN MRI AND SHIELDED ENVIRONMENT. ELECTRIC AND MAGNETIC FIELD FROM 10 khz TO 300 MHz*

DEEP FLAW DETECTION WITH GIANT MAGNETORESISTIVE (GMR) BASED SELF-NULLING PROBE

Smart Electromagnetic Flowmeter Open channel Flowmeter Detector

WaveAce 1000 and 2000 Oscilloscopes

MARKING / FCC. Test Report n FCC Rev. 01

Techniques for Suppressing Adverse Lighting to Improve Vision System Success. Nelson Bridwell Senior Vision Engineer Machine Vision Engineering LLC

Surface ECA Probe Catalog. February 2017

ADVANCED COMBINATION PROBE FOR TESTING FERRITIC SEA-CURE CONDENSER TUBING

2620 Modular Measurement and Control System

MGL Avionics Autopilot. Servo. Specifications & Installation Manual. Last Update: 20 October Disclaimer:

Modelling III ABSTRACT

Maximizing the Fatigue Crack Response in Surface Eddy Current Inspections of Aircraft Structures

RFC EDDY CURRENT PROBE TESTS. Wally C. Hoppe and David A. Stubbs

Steam Generator Tubing Inspection

Smart Electromagnetic Flowmeter Open channel Flowmeter Detector

T22. Data Sheet. Torque transducer. Special features. Installation example with two bellows couplings. B en

SGD-EEM «MEDUSA» GEOELECTRICAL MULTIFUNCTION RECEIVER

Product and Measurement Solutions for the Automotive Industry

2.5D Finite Element Simulation Eddy Current Heat Exchanger Tube Inspection using FEMM

A Numerical Study of Depth of Penetration of Eddy Currents

EMC-scanner. HRE-series. See it before you CE it!

A Reference Guide. Continuous Hinge, Inventory and Service Worldwide Est End Play Design Engineering with Standard Continuous Hinges

Principles of Vibration Measurement and Analysis. Dr. Colin Novak, P.Eng July 29, 2015

QA-ES III Electrosurgical Analyzer

QA-ES III Electrosurgical Analyzer

RGH24 encoder system. Data sheet L C. RGH24 readhead: RGS20 scale:

FISCHER CUSTOM COMMUNICATIONS, INC.

UT Thickness Gauge DC Instruction Manual

MULTI-PARAMETER ANALYSIS IN EDDY CURRENT INSPECTION OF

Giant Magnetoresistance Based Eddy-Current Sensor for High-Speed PCB Defect Detection

Instruction Manual Veritest

Transcription:

AIRCRAFT SET OF EDDY CURRENT FLAW DETECTOR EDDYCON C FOR AIRCRAFTS TESTING Surface and sub defect detection. Assessment of defect depth. Conductivity measurement. Paint thickness measurement. EN 13860-1 Compliant EN 13860-2 Compliant CE MARKING www.ndt.com.ua

2 PURPOSE FLAW DETECTOR ADVANTAGES FLAW DETECTOR DISTINCTIVE FEATURES Set of eddy current equipment for non-destructive testing of aircraft parts on the basis of EDDYCON C flaw detector is used for detection of cracks in various parts, cracks in holes and multilayered structures, and sub corrosion. Eddy current is an acceptable method for detecting conductivity of non-ferrous materials and paint thickness. ACCORDING TO THE REGULATORY DOCUMENTATION THE EDDY CURRENT IS USED ON: Window and door frames. Aircraft wheels. Pre-buy aircraft inspections. Surface crack high-frequency inspection. Sub low frequency inspection. Multi layer of metal crack detection. Part edges. Crack progression verification. Tuning out from the influence of an clearance and inhomogeneity of electromagnetic properties of a testing object. Storage of a great number of setups and testing results in the flaw detector memory. Mode of two-way connection with PC via USB port (for inputting the information from the flaw detector memory into PC and possibility of this data printing as well as setups loading from PC into the flaw detector memory). Color high-contrast TFT display. ALARM system: 4 three-color LEDs, sound alarm. Possibility to operate in two-frequency mode. Possibility to assess the paint thickness. Simplified procedure of instrument calibration on standard calibration blocks. Possibility of encoder and eddy current rotary scanner connection. Marking the start and end of a crack to facilitate stop drilling. Cracks around fasteners. Aircraft part extent of corrosion verification and damages from mechanical peeling. Crack detection on Aluminum, Titanium, Iron, Stainless Steel, Inconel, Nickel, Magnesium. Upgrading the flaw detector software using USB Flash Card. Conditional assessment of a defect depth and length. Readily removable battery. Time of contentious battery operation 8 hours. Light and sound ALARM system. Operation simplicity due to the intuitive interface. Small mass and dimension parameters. Exceptional signal/noise ratio. Possibility to operate with eddy current probes (ECPs) and rotary scanners from different manufacturers. USB slave. Compliance with BSS7048. Allows to carry out the testing according the requirements of NON-DESTRUCTIVE TEST MANUAL (51-00 PART 6, 71-20 PART 6 and etc.) SPECIFICATIONS AND SERIVCE FUNCTIONS OF THE FLAW DETECTOR Detecting defects with the depth _from 0.05 mm and width from 0,002 mm. Setup range of frequencies _from 10 Hz to 16 MHz. Generator output voltage (double amplitude) from 0,5 V to 6 V. Adjusted gain range _100 db. Signal phase change (range of signal rotation from 0 to 360 with a step 0.1, 1, 10 ). Samples frequency up to 10 khz. Digital signal filtering (there are 4 filter types: Lowpass, Highpass, Bandpass, Averaging). Eddy current signal display: a) complex plane (XY) - allows to detect defects among interferences by analyzing the signal waveform; b) mix of two frequencies can be used for suppression of interfering factors and reduction of their influence on testing results (for mixing an operator can choose one of 4 algorithms: summation, subtraction, summation with horizontal inversion, summation with vertical inversion).

а) Complex plane (XY) b) Mix of two frequencies (MIX) possibility to move the complex plane center to any visible part of the screen; two modes of instrument operation: Dark - for operation with faint outer lighting; Light - for operation with intense outer lighting; 3 b) Dark mode various types of information display on the flaw detector screen: b) Light mode а) Menu+XY+A(t) b) Menu+XY c) Menu+A(t) d) XY+A(t) e) XY f) A(t)

4 time of flaw detector operation mode setup _up to 1 minute; Persistence function (adjustable time for clearing the screen is from 0.1 s; 0.5 s; 1 s; 2 s; 3 s; 4 s); built-in clock and calendar; screen backlight and screen brightness control; overload indicator of an input circuit; battery life indicator; possibility of ECP connection of various constructions: differential ECP; differential ECP, connection by the bridge circuit; differential transformer ECP with center-point ground; differential transformer ECP; single (parametric) ECP; absolute transformer ECP. possibility of eddy current rotary scanner connection for the testing of openings and special-purpose scanners; user-friendly multi-language interface; time of continuous flaw detector operation with the fully charged storage battery at least 8 hours; total average life at least 10 years; flaw detector is powered from the built-in storage battery with rated voltage 12 V and rated capacity of 4500 ma h; temperature range _from minus 20 0 С to plus 45 0 С; weight of flaw detector with a storage battery no more than 0,9 kg; overall dimensions of the flaw detector - no more than 230 x 135 x 98 mm. BASIC DELIVERY SET OF THE FLAW DETECTOR EDDYCON C Name and reference designation Quantity Electronic unit of eddy current flaw detector EDDYCON C 1 pc. Mascot 2015/Friwo charger _1 set. Connection cable (PC/electronic unit, USB) 1 pc. Registration certificate for Eddycon C _1 copy Certificate of verification for the flaw detector EDDYCON C 1 copy Operation manual for Mascot 2015/ Friwo 1 copy Software for the PC _1 package. Soft case for the flaw detector 1 pc. Carrying Case 1 pc. ADDITIONAL EQUIPMENT Name and reference designation Rotary scanner SVR-02 Eddy current probes Connection cable (Reflection, Bridge, Lemo 12 - Lemo 04 (type 0В)), 1800 mm Connection cable (Electronic unit /SVR-02, Lemo 12 - Lemo 12), _1800 mm Connection cable (Reflection, Bridge, Lemo 12 - Lemo 03), 1800 mm Connection cable (Electronic unit / parametric ECP, Lemo 00 - Lemo 00/BNC/Microdot), _1800 mm Headphones Calibration block 2353.08 (for operation with ECPs) Calibration block 2353.12 (for operation with rotary ECPs)

.. ECPs FOR AIRCRAFTS TESTING NAME SIZE OVERALL FIELD No. AND OF OPERATING DIMENSIONS, NOTE OF APPEARANCE SURFACE, ММ/INCH ММ/INCH APPLICATION ECPs for defects detection 1. SU1.8M3.2x64DSS1 - Shielded 3,2/.125 9,6 x 64/.38 x 2.5 Spherical Centre frequency - 1.8 MHz R1,6 2. SU1.8М3А3.2x12.5DSS1 - Shielded 3,2/.125 9,6 x 64/.38 x 2.5 Spherical Centre frequency - 1.8 MHz R1,6 3. SU1.8М5А3.2x12.5DSS1 - Shielded 3,2/.125 9,6 x 64/.38 x 2.5 Spherical R1,5 4. 5. SU1.5M3DS1 - Unshielded SU1.5M3DS02 - Unshielded 3/.118 3/.118 12,5 x 76/.5 x 3 12,5 x 76/.5 x 3 R1,6 Spherical Spherical R1,5 Detection of defects in aluminum, titanium and magnum alloys 6. SS1.5M05DA0 5/.197 13 x 35/.51 x 1.38 Planar 7. SS650K06DA0 6/.24 13 x 35/.51 x 1.38 Planar Centre frequency - 650 khz 8. SS400K07DA0 7/.26 13 x 35/.51 x1.38 Planar Centre frequency - 400 khz 5 ECP for sub defects detection 9. SS170K13DA0 13/.51 13 x 35/.51 x 1.38 Planar Centre frequency - 170 khz 10. SS50K15DA0 15/.59 15 x 35/.59 x 1.38 Centre frequency - 50 khz.. ECP for defects in holes detection 11. RO1.7M5A"Х 1 "DFD0 from 3.1/.12 tо 25.4/.122 1 Flexible ECP for Centre frequency - 1.7 MHz semi-automated testing 12. RO1.7M5A"Х 2 "DRD0 from 3.1/.12 to 25.4/.122 1. Rigid ECP with Centre frequency - 1.7 MHz semi-automated testing 13. RO1.2M5A"Х 3 "DFА0 from 3.1/.12 tо 25.4/.122 1 Flexible ECP for manual testing. Detection of sub defects in aluminum alloys. Testing of primary elements of structure under the cover in 2-3 layer. Detection of defects in aluminum, titanium and magnum alloys Possibility to produce other ECP types by the cuctomer request. Note - Teflon tape is used to protect the ECP. 1 ECP nominal diameter; 2 ECP nominal diameter; 3 ECP nominal diameter.

6 DESIGNATION OF EDDY CURRENT PROBE ХХ ХХХ XA XXX x YYY X X 1 2 3 4 5 6 1 - ECP configuration. 2 - ECP 3 - ECP angle. 4 - Size of ECP. 5 - ECP probe designation. 6 - ECP modification 1. ECP configuration SU - ( probe) - probes for defects detection. SS - (sub probe) probes for and /or sub defects detection (MDF - type) OD - (OD probe) outer Encircling probe. ID - (ID probe) inside Bobbin probe. RO - rotation probe. 2. ECP frequency ХХХHZ - "HZ" designation for "Hz" range; ХХХК - "К" designation for "кhz" range; ХХХМ - "М" designation for "MHz" range. 3. ECP angle ХА - incidence angle of a sensitive element to the ECP axis. Angle range: 0А - 0; 1А - 15; 2А - 25; 3А - 45; 4А - 60; 5А - 90; If the incidence angle of a sensitive element concedes with the ECP axis, than this designation is only marked for the rotary ECPs with the sensitive element located on the probe tip (0А). 4. Size of ECP ХХХD - "D" designation for the diameter of an of and bobbin ECPs; ХХХ-ХХХD - "D" designation for diameters during the testing by adjustable rotary ECPs.; ХХХDR - "DR" (R - rigid) designation for the diameter during the testing with rotary ECPs with a metallic case for the holes of a rigid diameter; ХХХDF - "DF" (F - flexible) designation for the diameter during the testing with rotary ECPs with a flexible derling material during the holes testing with the acceptance. ХХХ x YYY - designation for ECP of SU type, those sensitivity element is declined from the ECP longitudinal axis. ХХХ - diameter of, YYY - bending length from the ECP longitudinal axis. ХХХ/YYY - designation for ECT with a rectangular shape of the. 5. ECP probe designation. D - differential; А - absolute; S/SS -single, additional S is added in case of a probe shielding (single shielded); В - bridge. 6. ECP modification Designated with digits: 0-9. PROMPRYLAD LLC P.O.Box 43, Kiev 04080, Ukraine, tel./fax: +38 044 467 51 38 (39) E-mail:office@ndt.com.ua www.ndt.com.ua