Recommended Training Curriculum For Digital Radiography Personnel (Level II)

Similar documents
Film Replacement in Radiographic Weld Inspection The New ISO Standard

Conversion to Digital Radiography from Film Radiography

Migrating from traditional to Digital Radiography in Aerospace

Minimum Requirements for Digital Radiography Equipment and Measurement Procedures by Different Industries and Standard Organizations

Hardware for High Energy Applications 30 October 2009

Standard Practice for Qualification of Radioscopic Systems 1

ISO INTERNATIONAL STANDARD

Computed Radiography

Spokane Industries Computed Radiography Implementation Experience. David Jolin Technical Sales

Experiences of users in Digital Radiography

Engineering Policy & Procedure

ISO INTERNATIONAL STANDARD. Non-destructive testing of welds Radiographic testing Part 2: X- and gamma-ray techniques with digital detectors

Equivalent Penetrameter Sensitivity (EPS) for Performance Evaluation of Computed Radiography Systems Muzibur Khan * and Mike Brothers

Advancements In Digital Radiography: CR, DR, and DICONDE

Moving from film to digital: A study of digital x-ray benefits, challenges and best practices

Essential Parameters for the Visibility of IQIs and Small Indications in Digital Radiography

ISO INTERNATIONAL STANDARD. Non-destructive testing of welds Radiographic testing Part 1: X- and gamma-ray techniques with film

Amorphous Selenium Direct Radiography for Industrial Imaging

Digital Radiography : Flat Panel

PERFORMANCE CHARACTERIZATION OF AMORPHOUS SILICON DIGITAL DETECTOR ARRAYS FOR GAMMA RADIOGRAPHY

SYLLABUS. TITLE: Equipment Operation I. DEPARTMENT: Radiologic Technology

» There are many possible techniques for making good radiographs. » Following a defined procedure will simplify technique

NAVSEA Requirements for Computed Radiography DRAFT

SECTION I - CHAPTER 2 DIGITAL IMAGING PROCESSING CONCEPTS

Digital radiography: Practical advantages of Digital Radiography. Practical Advantages in image quality

Fig.2: Scanner VistaScan for image plates

FOCUS. Digital Radiography in Industry: Digital Detector Arrays in Radiographic Testing. Introduction. Definitions. by Brad Kraai

17th World Conference on Nondestructive Testing, Oct 2008, Shanghai, China

Acquisition, Processing and Display

Minimum Requirements for Digital Radiography Equipment and Measurement Procedures by Different Industries and Standard Organizations

Digital Radiographic Inspection replacing traditional RT and 3D RT Development

IQI-Sensitivity and Applications of Flat Panel Detectors and X-Ray Image Intensifiers A Comparison

Essential Parameters and Conditions for Optimum Image Quality in Digital Radiology

ON THE WAY TO DIGITAL RADIOGRAPHY

APPLICATION OF THE DIGITAL RADIOGRAPHY IN WELD INSPECTION OF GAS AND OIL PIPELINES

10/26/2015. Study Harder

Performance evaluation of a photon counting detector for high energy NDT applications

UNDERSTANDING THE CURRENT CAPABILITIES AND LIMITATIONS OF DIGITAL INDUSTRIAL RADIOGRAPHY

10/3/2012. Study Harder

Digital Imaging Considerations Computed Radiography

This document is a preview generated by EVS

DIGITAL IMAGING Recognise the importance of quality assurance

In-service inspections for primary coolant circuit components of light water reactors Part 6: Radiographic testing

Standard Test Method for Radiographic Examination of Metallic Castings 1

AUTOMATED AND QUANTITATIVE METHOD FOR QUALITY ASSURANCE OF DIGITAL RADIOGRAPHY IMAGING SYSTEMS

Real Time Linear Array Imaging. Brian Caccamise

A COMPARATIVE STUDY ON THE PERFORMANCE OF DIGITAL DETECTOR SYSTEMS FOR HIGH ENERGY APPLICATIONS

DIGITAL RADIOGRAPHY. Digital radiography is a film-less technology used to record radiographic images.

COMPUTED RADIOGRAPHY CHAPTER 4 EFFECTIVE USE OF CR

HPX1-Plus. For Non-Destructive Testing. THE BENCHMARK IN COMPUTED RADIOGRAPHY.

RAD 150 RADIOLOGIC EXPOSURE TECHNIQUE II

NDT Supply.com 7952 Nieman Road Lenexa, KS USA

THE CR SPECIALISTS HD-CR CR 35 NDT

CR Basics and FAQ. Overview. Historical Perspective

A TUTORIAL FOR PERFORMING A RADIOGRAPHIC EXAMINATION

NDE SOLUTIONS RADIOGRAPHY COURSE OUTLINE

NON-DESTRUCTIVE EVALUATION UTILIZING IMAGING PLATES FOR FIELD RADIOGRAPHY APPLICATIONS

Digital Detector Array Image Quality for Various GOS Scintillators

Dürr NDT GmbH & Co. KG Höpfigheimer Straße 22 D Bietigheim-Bissingen Germany. Contract No. BAM ZBA Dürr

Small Animal Radiographic Techniques and Positioning COPYRIGHTED MATERIAL

Digital Industrial Radiography

RADIOGRAPHIC EXAMINATION PROCEDURE

A True Innovation in Non-Destructive Testing System FUJIFILM COMPUTED RADIOGRAPHY. Series 4 CR

Radiology Physics Lectures: Digital Radiography. Digital Radiography. D. J. Hall, Ph.D. x20893

ISO INTERNATIONAL STANDARD. Non-destructive testing of welds Radiographic testing of fusionwelded

REAL-TIME X-RAY IMAGE PROCESSING; TECHNIQUES FOR SENSITIVITY

SINCE2011 Singapore International NDT Conference & Exhibition, 3-4 November 2011

The HOIS recommended practice for in-service computed radiography of pipes

Seminar 8. Radiology S8 1

Dürr NDT GmbH & Co. KG Höpfigheimer Straße 22 D Bietigheim-Bissingen Germany. Contract No. BAM ZBA Dürr

Acceptance Testing of a Digital Breast Tomosynthesis Unit

Do you have any other questions? Please call us at (Toll Free) or , or

Pre Conference Workshop on Advanced Digital imaging

I. PERFORMANCE OF X-RAY PRODUCTION COMPONENTS FLUOROSCOPIC ACCEPTANCE TESTING: TEST PROCEDURES & PERFORMANCE CRITERIA

Current technology in digital image production (CR/DR and other modalities) Jaroonroj Wongnil 25 Mar 2016

5th Pan American Conference for NDT 2-6 October 2011, Cancun, Mexico

Standard Practice for Radiographic Examination 1

Any question concerning this ballot item should be addressed to Cliff Bueno at or

NDE Technology of Pressure Equipment in Line with International Standards

NEW POSSIBILITIES OF RADIATION CONTROL OF QUALITY OF WELDED JOINTS

Examination of Pipe Welds by Image Plate Based Computed Radiography System

SECTION I - CHAPTER 1 DIGITAL RADIOGRAPHY: AN OVERVIEW OF THE TEXT. Exam Content Specifications 8/22/2012 RADT 3463 COMPUTERIZED IMAGING

Digital Radiography for the Inspection of Small Defects

Introduction. Chapter 16 Diagnostic Radiology. Primary radiological image. Primary radiological image

Digital Radiography Systems Techniques and Performance Evaluation for Space Applications

3/31/2011. Objectives. Emory University. Historical Development. Historical Development. Historical Development

Preliminary Modulation Transfer Function Study on Amorphous Silicon Flat Panel System for Industrial Digital Radiography

High Energy Digital Radiography & 3D-CT for Industrial Systems

Digital Radiology with Photon Counting Detectors

SPRINGFIELD TECHNICAL COMMUNITY COLLEGE ACADEMIC AFFAIRS

Part 3: Image quality classes

HIGH SPEED, HIGH RESOLUTION AND LOW COST DIGITAL RADIOGRAPHY

DIGITAL IMAGE PROCESSING IN X-RAY IMAGING

Overview of Safety Code 35

Guidelines on Training, Examination and Certification in Digital Industrial Radiology Testing (RT-D)

The HOIS recommended practice for in-service computed radiography of pipes. Dr Stephen F Burch, WCNDT 2012, Durban, SA. April 2012

UNDERSTANDING THE CHALLENGES IN THE TRANSITION FROM FILM TO DIGITAL RADIOGRAPHY IN THE NUCLEAR POWER INDUSTRY

Determination of Optimum X-Ray Tube Output Parameters kv and ma for Digital Radiography Testing of Welded Tubes

digital radiography r High-energy DT Applications lior Pick, Ron Pincu and Ofra Kleinberger over film radiog- p P This advanced

The field deployable digital X-Ray solution for weld inspection in O&G

Transcription:

Paper No. 005-11 Recommended Training Curriculum For Digital Radiography Personnel (Level II) 1 December 2011 This document was created by the Federal Working Group on Industrial Digital Radiography. Reproduction is authorized.

Federal Working Group on Industrial Digital Radiography (FWGIDR) - The FWGIDR is a self-chartered organization consisting of federal and government contract employees and endorsed by the Defense Working Group on Nondestructive Testing (DWGNDT). This working group provides a platform for identifying common concerns and critical issues facing the federal industrial radiographic community as it transitions from film to digital radiography (DR). The FWGIDR, utilizing expertise from within the community, organizes and coordinates technical committees that formulate positions, guidance, and/or solutions for the community s common concerns and issues. Background Recognizing significant difficulties in addressing technical advances in the digital radiographic field, several engineers from the Department of Energy (DOE) and Department of Defense (DoD) organized the FWGIDR in 2007 to address the problems and concerns faced by the industrial radiographic community in transitioning to DR. Digital X-ray systems are revolutionizing medical radiology, as digital cameras revolutionized the photographic community, and similarly have an ever-increasing role in radiographic nondestructive testing. Medical radiology backed by significant development and funding, and digital photography, with rapid public acceptance; have demonstrated the advantages that digital systems offer in image intensive applications. The FWGIDR is focused on a vision for the future radiographic inspection facility, and that vision is digital radiography. The rapid growth in DR has created transitional issues difficult for the industrial community to assimilate while transitioning from film to digital techniques. These issues include personnel training; data formatting, storage and retrieval; technique development and qualification; equipment qualification and monitoring; process control; and development and acquisition of equipment suitable for industrial applications. Participants in the FWGIDR are organizations that employ nondestructive testing in support of government contracts. DOE, DoD, prime government contractors, along with other government and contractor personnel are actively contributing to and supporting the efforts of this working group. 1

Introduction This paper, Recommended Training Curriculum for Digital Radiography Personnel (Level II), was developed by a task team established by the FWGIDR. It addresses a major concern of the federal industrial radiographic community regarding personnel training. Original equipment manufacturers (OEMs) commonly offer Digital Radiography (DR) equipment familiarization training but provides limited, if any, basic DR training. There has been a need to establish appropriate DR training curriculums for Level I, II and III personnel. In September of 2009, the FWGIDR released a white paper, Paper No. 001-009, which provided a recommended DR training curriculum for Level III personnel. This is a continuation of the FWGIDR efforts to improve DR training. This white paper provides a recommended training curriculum for Level II DR personnel that is specifically designed to ensure compliance with NAS 410 requirements. Purpose This paper is intended as a recommended reference/guide for DR training curriculums for Level II radiographic film personnel transitioning to Level II DR functions as well as those that are already employing DR systems and techniques. Scope This curriculum covers DR principles, equipment and implementation issues that should be understood by Level II DR personnel. This training curriculum is intended for personnel that will utilize computed radiography systems (CR) and/or digital detector array (DDA) based DR systems. Prerequisite This curriculum does not cover basic radiography inspection principles. It was designed for personnel who already have training equivalent to the 80 hours recommended by the ASNT s recommended practice SNT-TC-1A, Aerospace Industries Association s NAS 410, or equivalent knowledge. 2

This training curriculum is intended for certified Level II film radiographers who are transitioning to digital radiography. The recommended training hours for this curriculum is 40 hours. Suggested hours for each section are noted in parenthesis. (If the candidate has completed formal training in Level I digital radiography, subject matter previously covered in the Level I training does not need to be repeated to the extent it was presented.) Note: Basic computer competency skills are necessary to transition from film radiography to non-film radiography. 1. Introduction (1.0 Hours) 1.1. Definition of Digital Radiography (DR) 1.2. Overview of DR Systems 1.2.1. Basic System Components 1.2.1.1. Computed Radiography (CR) systems 1.2.1.2. Digital Detector Array (DDA) based systems 1.2.1.3. Image Intensifier (II) based systems 1.2.2. DR System Capabilities 1.2.3. Advantages and Disadvantages of DR 1.2.4. Application Examples 1.3. Digital Image Terminology 1.3.1. Bits 1.3.2. Bytes 1.3.3. Pixels 1.3.4. Bit Depth 1.4. Cost and Environmental Impact Comparisons (Film vs. DR) 2. DR vs. Film Images (1.0 Hours) 2.1. Image Quality Parameters 2.1.1. Linearity 2.1.2. Latitude 2.1.3. Pixel Value (Grey Value) 2.1.4. Signal to Noise Ratio (SNR) 2.1.5. Contrast Sensitivity (CS) 2.1.6. Contrast to Noise Ratio (CNR) 2.1.7. Spatial Resolution (SR) 2.2. Image File Formats 2.2.1. Compression 2.2.2. Lossy and Lossless (jpg, tiff, etc.) 2.2.3. DICONDE 3

3. DR System Components (Detailed) (6.0 Hours) 3.1. Sources (X-Ray and Gamma Ray) 3.1.1. Energy, Current, Power 3.1.2. Curies 3.1.3. Focal Spot / Source Size 3.1.4. X-Ray Tubes 3.1.4.1. Open Tubes vs. Closed Tubes 3.1.4.2. Directional vs. Transmission Tubes 3.1.5. Gamma Sources 3.1.5.1. Iridium-192, Cobalt-60, Selenium-75, Ytterbium-169 3.2. Scatter Control Devices 3.2.1. Filters (Pre and Post Specimen) 3.2.2. Collimators and Diaphragms 3.2.3. Masks 3.2.4. Shielding 3.3. Hardware Manipulators 3.3.1. Multiple Axis 3.3.2. Precision and Repeatability 3.3.3. Weight Capacity 3.3.4. Motion Control 3.3.4.1. Manual and Automated 3.3.4.2. Crash Protection (Limits) 3.4. Detector Types 3.4.1. Digital Detector Arrays (DDA) 3.4.1.1. Flat Panel Detectors 3.4.1.1.1. Amorphous Silicon 3.4.1.1.2. Amorphous Selenium 3.4.1.1.3. CMOS 3.4.1.2. Cameras 3.4.1.2.1. CCD 3.4.1.2.2. CMOS 3.4.1.3. Linear Diode Arrays (LDA) 3.4.1.3.1. CMOS 3.4.1.3.2. Photodiode 3.4.1.4. Scintillators 3.4.2. Computed Radiography System 3.4.2.1. Photostimulable Luminescence (PSL) 3.4.2.2. Imaging Plates (IPs) and Cassettes 3.4.2.3. CR Scanner and Settings 3.4.2.3.1. Laser 3.4.2.3.2. Photomultiplier Tube 4

3.4.2.3.3. Analog to Digital Converter 3.5. Computer 3.5.1. Operator Interface 3.5.2. System Controller 3.5.3. Image Processor 3.6. Image Displays 3.6.1. Display Card 3.6.2. Image Display Monitors 3.6.2.1. CRT, LCD, LED, Plasma, etc. 3.7. Image Archive and Transmission Media 3.7.1. Removable Media (CD/DVD/Blue Ray/Tape, Portable Hard Drive, etc.) 3.7.2. Redundant Array of Inexpensive Disks (RAID) 3.7.3. Central Server 4. Image Fidelity Attributes (1.0 Hours) 4.1. Signal 4.2. Noise 4.3. Contrast 4.4. Spatial Resolution 4.5. Software Tools to Measure Image Attributes 4.5.1. Histogram 4.5.2. Line Profile 4.5.3. Mean and Standard Deviation 5. Image Processing (4.0 Hours) 5.1. Intensity Transforms 5.1.1. Windowing (Width and Level) 5.1.2. Gray Scale Mapping (Look Up Tables) 5.1.3. Thresholding 5.1.4. Pseudo Color 5.2. Image Math 5.2.1. Addition (Integration) 5.2.2. Subtraction 5.2.3. Division 5.2.4. Multiplication 5.2.5. Averaging 5.3. Filtering 5.3.1. Convolution (Spatial) 5.3.1.1. Smoothing (Low Pass) 5.3.1.2. Sharpening (High Pass) 5.3.1.3. Median 5.3.1.4. Unsharp Mask 5

5.4. Advantages and Disadvantages of Image Processing 6. Detector Attributes (4.0 Hours) 6.1. DDA - Pixel Pitch and Fill Factor 6.2. CR Pixel Size vs. Laser Size, Laser Intensity, IP Grain Size and Thickness 6.3. Sampling Frequency 6.4. Frame Rates 6.5. Triggers 6.6. Bit Depth 6.7. Linear vs. Log 6.8. Dynamic Range 6.9. Low Energy X-Ray Sensitivity (Scatter) 6.10. Signal To Noise Ratio 6.11. Fabrication Anomalies (Bad Pixels, Artifacts, panel grading, etc.) 6.12. Handling and Portability 6.13. Preset and Manual Settings 6.14. Radiation Tolerance 7. Image Display Monitor Characteristics (0.5 Hours) 7.1. Resolution and Pixel Size 7.2. Bit Depth 7.3. Brightness 7.4. Contrast 7.5. Dynamic Range 8. Viewing Environment (0.5 Hours) 8.1. Ambient Lighting 8.2. Humidity and Temperature 8.3. Glare, Reflections, Fingerprints, etc. 8.4. Eye Adaptation 8.5. Ergonomics 9. DR Techniques (Part Specific) (4.0 Hours) 9.1. Basic Parameters and Settings 9.1.1. Radiation Energy (kv) / Gamma Source 9.1.2. X-Ray Tube Current (ma) / Gamma Source Strength 9.1.3. Exposure Time (Frame Rate or Integration Time for DDAs) 9.1.4. Filtering (pre or post) 9.1.5. Masking 9.1.6. IQI Selection and Placement 9.1.6.1. IQI pixel value vs. Area of Interest (plus/minus 15%) 9.2. DR Distinctive Parameters and Settings 9.2.1. Signal To Noise Ratio (SNR) 6

9.2.2. Contrast to Noise Ratio (CNR) 9.2.3. Basic Spatial Resolution (SR b ) 9.2.4. Geometric Magnification (FDD, FOD, Optimizing for focal spot and SR b ) 9.2.5. Normalized Image Unsharpness (U Im ) 9.2.6. Field of View 9.2.7. Pixel Dimension (Apparent pixel size at field of view based on known dimension ) 9.2.8. DDA Specific 9.2.8.1. Gain and Offset Corrections (Detector Calibration) 9.2.8.2. Frame Rate 9.2.8.3. Frame Integration 9.2.8.4. Frame Averaging 9.2.8.5. Binning 9.2.8.6. Triggering (Internal and External) 9.2.9. CR Specific 9.2.9.1. IP Selection 9.2.9.2. IP Erasure 9.2.9.3. Scanner Settings 9.2.10. Image Processing 9.2.10.1. Window Width and Level 9.2.10.2. Intensity Transforms Parameters 9.2.10.3. Filtering Parameters 9.2.10.4. Processing Algorithms and Parameters 9.3. Technique Documentation 9.3.1. Exposure Parameters 9.3.1.1. Radiation Source Parameters 9.3.1.1.1. kv, current, Focal Spot, Beam Filters, etc. 9.3.1.2. DDA Settings 9.3.1.2.1. Frame Rate 9.3.1.2.2. Frame Averaging 9.3.1.2.3. Binning 9.3.1.2.4. Gain/Offset 9.3.1.2.5. Post Filters 9.3.1.3. CR Scanner Settings and IPs 9.3.1.3.1. IP Type, Cassette Type, Cassette Screens/Filters 9.3.1.3.2. Laser Spot Size 9.3.1.3.3. Scanner Presets 9.3.1.3.4. Sampling Rate 9.3.1.3.5. Gain Settings (Photomultiplier Tube) 9.3.2. Set-up Geometry 9.3.2.1. Focal Spot to Detector Distance (FDD) 9.3.2.2. Focal Spot to Object Distance (FOD) 7

9.3.2.3. Geometric Magnification 9.3.2.4. Geometric Unsharpness (U g ) 9.3.2.5. Normalized Image Unsharpness (U Im ) 9.3.3. Image Review Requirements 9.3.3.1. Window Width and Level 9.3.3.2. Digital Zoom 9.3.4. Image Processing Requirements 9.3.5. Measurement Calibration Requirements 9.3.6. Digital Reference Images 10. Image Interpretation (3.0 Hours) 10.1. Image Qualification 10.1.1. Area of Interest (AOI) vs. Region of Interest (ROI) 10.1.2. IQI and/or RQI Feature Verification (type, material, size, position, visibility, etc.) 10.1.3. Measure SNR 10.1.4. Measure CNR 10.1.5. Pixel Value Range 10.1.6. Image Identification, Traceability 10.1.7. Part Coverage 10.2. Image Evaluation 10.2.1. Identify Artifacts (acceptable or re-image required) 10.2.2. Relevant vs. Non-Relevant Indications 10.2.3. Measurement Calibration and Accuracy 10.2.4. Accept/Reject Criteria 10.2.4.1. Discrete vs. Digital Reference Images 10.3. Examination Reports and Records 11. Process Controls (System Baseline and Degradation Monitoring) (6.0 Hours) 11.1. CR System Performance Tests (System Characterization E2445) 11.1.1. Normalized SNR (SNR N ) 11.1.2. Geometric Distortion 11.1.3. Laser Beam Function 11.1.4. Blooming/Flare 11.1.5. Jitter 11.1.6. Scanner Slippage 11.1.7. Shading 11.1.8. IP Erasure 11.1.9. IP Artifacts 11.1.10. Characterization Tools and Use 11.1.10.1. CR Phantoms 11.1.10.1.1. ASTM E2445 Phantom 11.1.10.1.2. USAF CR Process Control Standard (AFRL-RX-WP-TR-2009-4069) 8

11.1.10.2. Gages and Use 11.1.10.2.1. E2002 Duplex Wire Gage 11.1.10.2.2. Converging and Parallel Line Pair Gages 11.1.10.2.3. EPS Gages (E746 and E1735) 11.2. DDA System Performance Tests (System Characterization E2737) 11.2.1. Basic Spatial Resolution (SRb) 11.2.2. Contrast Sensitivity 11.2.3. Material Thickness Range 11.2.4. SNR 11.2.5. Signal Level 11.2.6. Image Lag 11.2.7. Burn-In 11.2.8. Offset Level 11.2.9. Bad Pixel Distribution 11.2.10. DDA Phantoms 11.2.10.1. Duplex Plate 11.2.10.1.1. E2002 Duplex Wire Gage 11.2.10.1.2. IQIs (E1025 or E1742) 11.2.10.2. Five Groove Wedge 11.3. Image Display Monitor Performance Tests 11.3.1. SEMPTE - RP 133 Test Pattern 11.3.2. Minimum Brightness 11.3.3. Minimum Contrast Ratio 11.3.4. Aliasing 11.3.5. Resolution 11.3.6. Screen Flicker 11.3.7. Distortion 11.3.8. 5% DDL Blocks 11.3.9. Background Ambient Light 11.3.10. Performance check periodicity 12. Equipment Maintenance (1.0 Hours) 12.1. Open X-Ray Tubes 12.1.1. Focal Spot Degradation 12.2. CR Scanners 12.3. IP Cleaning and Artifact Management 12.4. Manipulators 12.5. Image Display Monitor Cleaning 13. Specific Equipment Training (8.0 Hours) 13.1. Software 13.2. Hardware 9

13.3. Total System Note: The listed 8 hours may be conducted separately from a classroom environment, and shall be conducted on specific equipment and procedures used by the employer. 14. Reference Documents Government Documents: United States Air Force Research Lab AFRL-RX-WP-TR-2009-4069, Development of USAF Computed Radiography (CR) Process Control Industry Documents: Aerospace Industries Association of America (AIA/NAS) NAS 410 NAS Certification and Qualification of Nondestructive Test Personnel ASME Boiler and Pressure Vessel Code (BPVC) Section V Nondestructive Examination, Article 2 Radiographic Examination Section V Nondestructive Examination, Article 2, Appendix VIII & IX America Society for Nondestructive Testing (ASNT) SNT-TC-1A Personnel Qualification and Certification in Nondestructive Testing ASTM International E746 Standard Practice for Determining Relative Image Quality Response Industrial Radiographic Imaging Systems E747 Standard Practice for Design, Manufacture and Material Grouping Classification of Wire Image Quality Indicators (IQI) Used for Radiology E1000 Standard Guide for Radioscopy E1025 Standard Practice for Design, Manufacture and Material Grouping Classification of Hole-Type Image Quality Indicators (IQI) Used for Radiology E1161 Standard Practice for Radiologic Examination of Semiconductors and Electronic Components E1165 Standard Test Method for Measurement of Focal Spots of Industrial X-Ray Tubes by Pinhole Imaging E1255 Standard Practice for Radioscopy E1316 Standard Terminology for Nondestructive Examinations E1411 Standard Practice for Qualification of Radioscopic Systems E1416 Radiologic Examination of Semiconductors and Electronic Components E1647 Standard Practice for Determining Contrast Sensitivity in Radiology E1734 Standard Practice for Radioscopic Examination of Castings E1742 Standard Practice for Radiographic Examination E1817 Standard Practice for Controlling Quality of Radiological Examinations by using Representative Quality Indicators (RQIs) 10

E1936 Standard Reference Radiograph for Evaluating the Performance of Radiographic Digitization Systems E2002 Standard Practice for Determining Total Image Unsharpness in Radiology E2007 Standard Guide for Computed Radiology (Photostimulable Luminescence Method) E2033 Standard Practice for Computed Radiology (Photostimulable Luminescence Method) E2104 Standard Practice for Radiological Examination of Advanced Aero and Turbine Materials and Components E2339 Standard Practice for Digital Imaging and Communication in Nondestructive Evaluation (DICONDE) E2422 Standard Digital Reference Images for Inspection of Aluminum Castings E2445 Standard Practice for Qualification and Long Term Stability of Computed Radiology Systems E2446 Standard Practice for Classification of Computed Radiology Systems E2597 Standard Practice for Manufacturing Characterization of Digital Detector Arrays E2660 Standard Digital Reference Images for Investment Steel Castings for Aerospace Applications E2662 Standard Practice for Radiological Examination of Flat Panel Composites and Sandwich Core Materials Used in Aerospace Applications E2669 Standard Digital Reference Images for Titanium Castings E2698 Standard Practice for Radiological Examination Using Digital Detector Arrays E2699 Standard Practice for Digital Imaging and Communication in Nondestructive Evaluation (DICONDE) for Digital Radiographic (DR) Test Methods E2736 Standard Guide for Digital Detector Array Radiology E2738 Standard Practice for Digital Imaging and Communication in Nondestructive Evaluation (DICONDE) for Computed Radiology (CR) Test Methods E2737 Standard Practice for Digital Detector Array Performance Evaluation and Long Term Stability European Standards EN12534-5 Characteristics of Focal Spots in Industrial X-Ray Systems for Use in Non-Destructive Testing, Part 5: Measurement of the Effective Focal Spot Size of Mini and Micro Focus X- Ray Tubes Society of Motion Picture and Television Engineers (SMPTE) SMPTE RP 133 Specification for Medical Diagnostic Imaging Test Pattern for Television Monitors and Hard Copy Recording Cameras 11