P2MP PMD Baseline. Prepared by Frank Effenberger Quantum Bridge Communications

Similar documents
Single Fiber, Single wavelength, GbE link

GPON OLT SFP Class C+

FTS-GPON-OLT-C+ GPON OLT SFP transceiver, 1490/1310nm, single-mode, RSSI, 60km

Marek Hajduczenia, ZTE Corp.

TS-GP2512-OLT-C+ GPON OLT Class C+ SFP Transceiver FEATURES

Single Fiber, Single wavelength, GbE / FE transceiver ODN requirements & performance measurements ODN = Optical Distribution Network

Burst Mode Technology

ITU-T G (03/2008) Gigabit-capable passive optical networks (GPON): Reach extension

50Gb/s technical feasibility analysis. Dekun Liu, Huawei Stanley Shuai, Source Sep, 2017

Part Number Operating temperature DDMI. APGPL43ASLCDSC+ Commercial Yes. APGPL43ASLIDSC+ Industrail Yes

EPON-OLT-20. OLT for IEEE 802.3ah-2004 PX Gbps Downstream and 1.25Gbps Upstream

DATASHEET 4.3. SFP+, 10GBase-LR, 1310nm, SM, DDM, 70km, RX sensitivity -22 dbm, Ind.temp.

CZGU-P3412-SB2DA Product Description Applications Features

DATASHEET 4.1. XFP, 10GBase-ZR, Multirate Gbps, DWDM 50GHz, SM, DDM, 24dB, 80km

SFP BIDI 2.5Gbps 40Km Tx1310/Rx1550nm / Tx1550/Rx1310nm

Diplexer Pigtailed Optical Subassembly. Description

Single-mode 1.25Gbps 2X10 SFF Transceiver

VCSEL Based 10 Gigabit Serial Solutions

V23870-A211x-xx00 (*) Bi-Directional Pigtail SFF Transceiver 155 Mb/s, 1310 nm Tx / 1310 nm Rx

10.3 Gb/s / 70 km / 1310 nm Digital Diagnostic SFP+ LC SINGLE-MODE TRANSCEIVER

Specification. T B S - S x C K 1 - F 1 1

IEEE July 2001 Plenary Meeting Portland, OR Robert S. Carlisle Sr. Market Development Engineer

EPON OLT 1.25Gbps 1000Base-PX20 Tx1490/Rx1310nm DDMI SLEP-1143-P

GPON ONU SFF 2X10 GNUF-3412S-B2CDA

3G Wireless Base Station SFP Transceiver Hot Pluggable, Duplex LC, 1310nm DFB, Single Mode, 15KM, DDM. Overview:

EPON-OLT-SFP-20. Features. Applications. Standard. 1.25G OLT 20km transmission

GDETP-XX21S-2CD DWDM EPON OLT SFP Transceiver

Single-mode 155Mbps 2X10 SFF Transceiver

Annex 91A Coexistence of 1 Gb/s (symmetric), 10 Gb/s (symmetric) and 10/1 Gb/s (asymmetric) Ethernet Passive Optical Networks (EPONs)

Single-mode 266Mbps Transmitter / Receiver

OC-48 LR-2/STM L-16.2 RoHS Compliant Pluggable SFP Transceiver

Single Fiber, Single wavelength, GbE / FE transceiver Foreign Ingress Issues

Product Specification OC-48 LR-2/STM L-16.2 Multirate 2x10 SFF Transceiver FTLF1621S1xCL

Product Specification. SFP OLT 1G 20km SC. 1.25Gbps Upstream/1.25Gbps Downstream GE-PON OLT Transceiver. SFP OLT 1G 20km SC

FTS-S12G-B35Y-020. SFP 1000Base-LX, BiDi, 1310/1550nm, single-mode, 20km

SFP-10G-LR-TX. Product Features. Applications. Product Selection. Cisco Compatible 10GBase-LR SFP TurboX

Gigabit Ethernet LC Bi-directional SFP Transceiver (80km) RBT12SZX

Singlemode 155Mbps Optical Transceiver SFP with MSA

Product Specification Sheet

SO-SFP-10GE-LR20-I. SFP+, 10GBase-LR, 1310nm, SM, DDM, 11.4dB, 20km ind.temp. OVERVIEW PRODUCT FEATURES APPLICATIONS ORDERING INFORMATION

Singlemode 1.25Gbps Bi-Directional Single Fiber Optical Transceiver

10 Gb/s / 10 km / 1310 nm Digital Diagnostic SFP+ LC SINGLE-MODE TRANSCEIVER

SO-XFP-10GE-BX60D E

MPN Theory Predictions vs. Measurements. Meir Bartur ZONU, Inc. IEEE ah interim January 2002 Raleigh, NC

Part Number Operating temperature DDMI. APGPU34AS3CXSC+ Commercial No. APGPU34AS3CDSC+ Commercial Yes. APGPU34AS3IXSC+ Industrial No

Multi-rate Gigabit Ethernet & Fibre Channel SFP Transceivers with Digital Diagnostics

SO-SFP-10GE-BX10D-3327-E

GPON ONU Series. EOLF-GU5-25-P Series. Features. Applications. Ordering Information. Case Temperature. Part No. Input Output Burst-mode Interface

Product Specification. RoHS-6 Compliant 10Gb/s 10km Single Mode Datacom SFP+ Transceiver FTLX1475D3BNV

SFP-1020-WA/B 10Gbps SFP+ Bi-Directional Transceiver, 20km Reach 1270/1330nm TX / 1330/1270 nm RX

SO-SFP-16GFC-ER-Dxxxx

Introduction of 25 Gb/s VCSELs

SOA pre-amplified upstream signal power in 100G EPON

Wavelength (nm) (m) ( o C) SPM-2100AWG 10.3 SR / SW 300 / 82 / 33* 850 VCSEL SFP+ with DMI -40 to 85 Yes

FEU3411P-2DC-1 Optical Transceiver for E-PON ONU, 10~20km Reach

ITU-T G (09/2007) Gigabit-capable Passive Optical Networks (G-PON): Enhancement band

Comment Supporting materials: The Reuse of 10GbE SRS Test for SR4/10, 40G-LR4. Frank Chang Vitesse

Lightem LSFP+BDxxx-LM20 Series 10Gbps SFP+ Bi-Directional Transceiver, 20km Reach 1270/1330nm TX / 1330/1270 nm RX

HOLT Transceiver for EPON (HOLT-11C214L22) 2X10 SFF, Pigtailed with SC, +3.3V, 1.25Gbps, 20km 1490nmTX/1310RX, DFB-LD/APD, 0~70. Feature.

GE-PON OLT Transceiver 1.25Gbps Upstream/1.25Gbps Downstream

Singlemode 1.25Gbps Optical Transceiver SFP with MSA

Single Fiber 1.25Gbps Bi-directional Optical Transceiver SFP with Digital Diagnostics

T S D S x C B 1 K 1 1

XTBxxA-20LY 10 Gbps SFP+ Bi-Directional Transceiver, 20 km Reach

SO-SFP-1000BASE-ZXD-I

Speed (Gb/s) (dbm) SPL-94B73B-WG B DFB 5 / / / 70 SC SFP with DMI Yes

GBP-XXXX192-L2C 10Gbps SFP+ Bi-Directional Transceiver, 20km Reach 1270/1330nm TX / 1330/1270 nm RX

SOEPB D EPON OLT Optical Transceiver

Parameter Symbol Min Typ Max Unit Remarks Data Rate DR GBd IEEE 802.3ae Bit Error Rate BER Input Voltage V CC

SFP+ BIDI Series JB1270-SFP-LC.S20

FTLX1471D3BCV. Product Specification. RoHS-6 Compliant 1G/10G 10km Datacom SFP+ Transceiver FTLX1471D3BCV

XFP BIDI Series JB1330-XFP-LC.S60. Features. Applications. Ordering information. Regulatory Compliance

Hot Pluggable, Duplex LC, 1310nm DFB-LD, Single Mode, DDM Distance: 10KM. monitor. mode fiber

SNR-SFP+W73-20 SNR-SFP+W db Power Budget BIDI SFP+ 10GbE Transceiver

Product Specification

WDM SFP+ модули предназначены для создания каналов связи по одноволоконному SM кабелю на расстояние до 20км.

G-PON ONU Small Form-Factor Transceiver

Product Specification

25G TDM PON overview. Ed Harstead, member Fixed Networks CTO Dora van Veen, Vincent Houtsma, and Peter Vetter, Bell Labs

Specification. T B D - S x D B 1 - F 1 1

T S P - D x A K 6 - T 2 S

Very Long Haul Gigabit Ethernet SFP Transceivers with Digital Diagnostics

GPON SFP OLT Transceiver GNTP-4321S-B2CDA

Multiplex, Inc. 8.5Gb/s DWDM 80Km LR2 XFP Transceiver Product. Product Overview. Features

ROHS Compliant MM SFP Transceiver 1.25Gb Gigabit Ethernet

Consideration about wavelength allocation in O-band

MITSUBISHI (OPTICAL DEVICES) MF-2500STA-xxxxx MF-2500SRA-xxxxx MF-2500SRB-xxxxx SONET / SDH TRANSMITTER / RECEIVER MODULE

20 + km GE-PON OLT Optical Transceiver SFF Module WST-2LCCC3-N6SWP

ITU-T. G Amendment 2 (08/2017) 40-Gigabit-capable passive optical networks 2 (NG-PON2): Physical media dependent (PMD) layer specification

155Mbps Single-mode 1310nm, SFP Transceiver

Physical Media Dependent Prototype for 10-Gigabit-Capable PON OLT

Gigabit Ethernet 850nm Multimode SFP Transceivers With Digital Diagnostics

Product Specification SFP WDM 1G 40km SC Transceiver

BIDI SFP Series. Part No. Data Rate Wavelength Interface Temp. DDMI

DTR-xxx-3.3-SM-T. 3.3 Volt Single Mode Transceivers (1x9 pin-out) ! Single +3.3 V supply & LV-PECL data interface. ! Eye Safe (Class I Laser Safety)

LinkPower LPS SM BIDI 2612TC/2612TI & 2613RC/2613RI SC. RoHS Compliant 1.25G 1310/1550nm & 1550/1310nm 20km Transceivers

Singlemode 155Mbps Optical Transceiver SFP with Digital Diagnostic

10Gb/s 10Km CDR SFP+ 1310nm Transceivers

10Gb/s CWDM SFP+ 80km Transceiver

125Mbps~155Mbps Multimode 850nm, SFP Transceiver

Transcription:

P2MP PMD Baseline Prepared by Frank Effenberger Quantum Bridge Communications

Supporters Tony Anderson Meir Bartur Vipul Bhatt Frank Effenberger Brian Ford John George Raanan Ivry Kent McCammon Tom Murphy Lisa Peng Jerry Radcliffe Walt Soto ZONU ZONU Self Quantum Bridge BellSouth Lucent Broadlight SBC Infineon Corning Hatteras Networks Agere

Overview Definitions Type 1 PMDs Type 2 PMDs Issues under discussion

Interface Definitions The OLT fiber interface is named the S/R point The ONT fiber interface is names the R/S point All Specifications herein refer to values measured at S/R and R/S points OLT PMD S/R ODN R/S ONT PMD OLT Implementer s Responsibility Network Operator s Responsibility ONT Implementer s Responsibility

S/R Optical Definitions ORL from viewpoint of OLT Launch power, extinction ratio, and Tx wavelength and spectral width Rx power and equipment reflectance at Rx wavelength OLT PMD Launch Power, ER Tx λ & λ S/R Rx Power Reqpt@λrx ORL ODN

ODN Optical Definitions Fiber type Attenuation range Maximum length Maximum optical path penalty S/R ODN Attenuation R/S Maximum Length Optical Path Penalty. Df: The difference in apparent link budget between a link that contains only loss (back to back measurement) and a link that contains the maximum optical impairment (e.g. maximum length, worst wavelength, etc.)

R/S Optical Definitions ORL from viewpoint of ONT Rx power and equipment reflectance at Rx wavelength Launch power (on and off states), extinction ratio, Tx wavelength and spectral width, and equipment reflectance at Tx wavelength ODN R/S Rx Power Reqpt@λrx ORL Tx λ & λ Launch Power (On & Off), ER Reqpt@λtx ONT PMD

Logical Link Definitions Data Rate Coding method Bit error rate

Burst Mode Definitions Tsd is the laser shut down time Tpb is the laser pre-bias time Tdsr is the dynamic sensitivity recovery time Tlr is the level recovery time Tcr is the clock recovery time Note: diagram below depicts minimum time scenario. Tsd Tdsr Tpb Tlr Tcr

Two sets of PMDs Type 1 (short) Loss and dispersion matched to 10km, 1:16 split Allows PIN-based OLT Type 2 (long) Loss and dispersion matched to 20km, >1:16 split Requires APD-based OLT, DFB ONT Maximal interoperability maintained ONT power levels are the same for both Intermixing of PMD types allowed Given technology advances, a single ONT type might be possible

Type 1 ODN Specs Fiber type Items Attenuation range Differential optical path loss Maximum optical path penalty Maximum fiber distance between S/R and R/S points Minimum supported split ratio Bidirectional transmission Unit km Values IEC 60793-10 Type B1.1 or B1.3 5-20 15 Downstream: 1 Upstream: 3 10 1:16 1-fiber WDM

Type 1 OLT Tx Specs Nominal bit rate Line code Minimum ORL of ODN Mean launched power MIN Mean launched power MAX Extinction ratio Items Operating wavelength SLM Laser Maximum 20 width SLM Laser Minimum side mode suppression ratio Unit Mbit/s nm m m nm Values 1250 1480-1500 1500 8b10b more than 20-4 +0 more than 9 1 30

Type 1 OLT Rx Specs Items Maximum reflectance of equipment at Rx wavelength Bit error ratio Minimum sensitivity Minimum overload Maximum time for dynamic sensitivity recovery Maximum time for level recovery Unit m m Bits Bits Values less than 20 less than 10 12-26 -3 tbd tbd Maximum time for clock recovery Bits tbd

Type 1 ONT Tx Specs Nominal bit rate Operating wavelength Line code Laser Pre-bias time Laser Shut-down time Items Maximum reflectance of equipment at Tx wavelength Minimum ORL of ODN Mean launched power MIN Mean launched power MAX Launched optical power without input to the transmitter Extinction ratio MLM Laser Maximum RMS width Unit Mbit/s nm m m m Bits Bits nm Values 1250 MLM 1270~1360 8b10b less than 6 more than 32-3 +2-39 more than 9 tbd tbd 2.4

Type 1 ONT Rx Specs Bit error ratio Minimum sensitivity Minimum overload Items Maximum reflectance of equipment at Rx wavelength Unit m m Values less than 20 less than 10 12-25 -5

Type 1 Link Budgets Downstream Direction Sensitivity Tx min: -4 Splitters: -15.2 Fiber: -4 Connectors: -0.8 Opt. Penalty: -1 Rx Min: -25 Overload Tx max: 0 Min loss: -5 Rx Max: -5 Upstream Direction Sensitivity Tx min: -3 Splitters: -15.2 Fiber: -4 Connectors: -0.8 Opt. Penalty: -3 Rx Min: -26 Overload Tx max: +2 Min loss: -5 Rx Max: -3

Type 2 ODN Specs Fiber type Items Attenuation range Differential optical path loss Maximum optical path penalty Maximum fiber distance between S/R and R/S points Minimum supported split ratio Bidirectional transmission Unit km Values IEC 60793-10 Type B1.1 or B1.3 10-25 15 Downstream: 1 Upstream: 1 20 1:16 1-fiber WDM

Type 2 OLT Tx Specs Nominal bit rate Line code Minimum ORL of ODN Mean launched power MIN Mean launched power MAX Extinction ratio Items Operating wavelength SLM Laser Maximum 20 width SLM Laser Minimum side mode suppression ratio Unit Mbit/s nm m m nm Values 1250 1480-1500 1500 8b10b more than 20 +1 +5 more than 9 1 30

Type 2 OLT Rx Specs Items Maximum reflectance of equipment at Rx wavelength Bit error ratio Minimum sensitivity Minimum overload Maximum time for dynamic sensitivity recovery Maximum time for level recovery Unit m m Bits Bits Values less than 20 less than 10 12-29 -8 tbd tbd Maximum time for clock recovery Bits tbd

Type 2 ONT Tx Specs Nominal bit rate Operating wavelength Line code Items Maximum reflectance of equipment at Tx λ Minimum ORL of ODN Mean launched power MIN Mean launched power MAX Maximum launched optical power when off Extinction ratio Laser Pre-bias time Laser Shut-down time SLM Laser Maximum 20 width SLM Laser Minimum side mode suppression ratio Unit Mbit/s nm m m m Bits Bits nm Values 1250 SLM 1270~1360 8b10b less than 6 more than 32-3 +2-39 more than 9 tbd tbd 1 30

Type 2 ONT Rx Specs Bit error ratio Minimum sensitivity Minimum overload Items Maximum reflectance of equipment at Rx wavelength Unit m m Values less than 20 less than 10 12-25 -5

Type 2 Link Budgets Downstream Direction Sensitivity Tx min: +1 Splitters: -15.2 Fiber: -8 Connectors: -1.8 Opt. Penalty -1 Rx Min -25 Overload Tx max: +5 Min loss: -10 Rx Max: -5 Upstream Direction Sensitivity Tx min: -3 Splitters: -15.2 Fiber: -8 Connectors: -1.8 Opt. Penalty -1 Rx Min -29 Overload Tx max: +2 Min loss: -10 Rx Max: -8

Compatibility matrix Type 1 ONT <10km away Type 1 ONT >10km away Type 2 ONT <10km away Type 2 ONT >10km away Type 1 OLT Type 1 ODN Yes N/A Yes N/A Type 2 OLT Type 2 ODN Yes No, but won t disrupt others Yes Yes

Summary of Specifications Table 1: Properties of the Passive Optical Networks Items Unit Specification Fiber type IEC 60793-10 Type B1.1 or B1.3 Type 1 Type 2 Attenuation range 5-20 10-25 Differential optical path loss 15 Maximum optical path penalty downstream 1 1 Maximum optical path penalty upstream 3 1 Maximum fiber distance between S/R and R/S points km 10 20 Minimum supported split ratio 1:16 Bidirectional transmission 1-fiber WDM Table 2: Properties of the 1250 Mb/s OLT PMDs Items Unit Values OLT Transmitter Nominal bit rate Mbit/s 1250 Operating wavelength nm 1480-1500 Line code 8b10b Minimum ORL of ODN more than 20 Type 1 Type 2 Mean launched power MIN m -4 +1 Mean launched power MAX m 0 +5 SLM Laser Maximum 20 width nm 1 SLM Laser Minimum side mode suppression ratio 30 Extinction ratio more than 9 OLT Receiver Maximum reflectance of equipment, measured at Rx wavelength less than 20 Table 3: Properties of the 1250 Mbit/s ONT PMDs Items Unit Value ONT Transmitter Nominal bit rate Mbit/s 1250 Operating wavelength nm 1270-1360 Line code 8b10b Maximum reflectance of equipment, measured at Tx wavelength less than 6 Minimum ORL of ODN more than 32 Mean launched power MIN m -3 Mean launched power MAX m +2 Launched optical power without input to the transmitter m -38 Extinction ratio more than 9 Laser Pre-bias time Bits tbd Laser Shut-down time Bits tbd Type 1 Type 2 MLM Laser Maximum RMS width (Note 1) nm 2.4 N/A SLM Laser Maximum 20 width nm N/A 1 SLM Laser Minimum side mode suppression ratio N/A 30 ONT Receiver Maximum reflectance of equipment, measured at Rx wavelength less than 20 Bit error ratio less than 10 12 Minimum sensitivity m -25 Minimum overload m -5 Bit error ratio less than 10 12 Type 1 Type 2 Minimum sensitivity m -26-29 Minimum overload m -3-8 Maximum time for dynamic sensitivity recovery Bits tbd Maximum time for level recovery Bits tbd Maximum time for clock recovery Bits tbd

Summary P2MP PMD baseline presented Two PMD sets A short set: easy to build, but strands a significant market segment A long set: more difficult, but addresses the longer distances Motion: To accept this presentation as a part of the baseline