Technical Data Sheet. Delta 1000/300

Similar documents
Analog Digital Multimeter with Insulation Resistance Measurement

RISH MIT 30 Analog Digital Multimeter with Insulation Resistance Measurement

Technical Datasheet. Delta Power 1000A / 400A AC-DC

GAMMA 20 DIGITAL MULTIMETER

Technical Data Sheet. Gamma 12. Gamma 12

SUBJECT TO CHANGE WITHOUT NOTICE

Technical Data Sheet. Zeta 20

GAMMA 12 DIGITAL MULTIMETER

GAMMA 10 DIGITAL MULTIMETER

Data Sheet. Analog - Digital Multimeter. RISH Multi RISH Multi Analog-Digital Multimeter. Page 1 of 6. Rishabh Instruments

RISH Multi 12S...18S Analog - Digital multimeters

1587/1577. Insulation Multimeters. Technical Data. Two powerful tools in one.

Fluke 355 and 353 True-rms 2000 A Clamp Meters Versatile and rugged tools for applications with high currents

1587/1577 Insulation Multimeters

Technical Data Sheet. x1000. kwh R Y B

DIGITAL DUAL DISPLAY AC/DC CLAMP METER MODEL-860A OPERATION MANUAL

Data Sheet. RISH Max-14 Analog-Digital Multimeter. RISH Max-14 Analog-Digital Multimeter. Page 1 of 5. Rishabh Instruments 1 / 05 / IX / 1210 / B

USER MANUAL 600A AC Clamp Meter + NCV Model MA610

USER'S MANUAL ACDC-100 TRMS ACDC-100. Versatile AC/DC Clamp-on Multimeter Series

User's Guide Extech EX Amp Clamp Meter with IR Thermometer

400Amp True RMS AC/DC Clamp Meter Model EX613

Compact Autoranging Clamp Meters. Models (400 A AC), (400 A AC/DC)

Fluke 370 FC Series true-rms wireless AC/DC clamp meters

MIT415 Insulation tester

RISH Max-12 and 14 Analog-Digital Multimeter. Data Sheet. RISH Max-12 and 14 Analog-Digital Multimeter. Rishabh Instruments

CLAMP-ON METER. Models 500, 501, 502, 503, 511, 512 & 514. Call toll free (800) or visit

AC/DC Clamp Meter. Owner's Manual. Model No Safety Operation Maintenance Español

User s Guide. 400A AC/DC Clamp Meter. Model MA Washington Street Melrose, MA Phone Toll Free

USER MANUAL. Model MA A AC Mini Clamp-on Meter. Additional User Manual Translations available at

AC/DC DIGITAL CLAMP METER OPERATION MANUAL

Digital Clamp Meter. User Manual

# Digital Multimeter

Multifunction Digital

RISHABH 6012 / 6013 / 6015 / 6016

True RMS Digital Multimeter Model:

AC/DC CLAMP METER CM4371, CM4373

User's Guide. 800 Amp AC/DC True RMS Clamp Meter. Model EX Washington Street Melrose, MA Phone Toll Free

ALPHA 20 MULTIFUNCTION METER (ALPHA SERIES)

User s Guide. 400A AC/DC Clamp Meter. Model MA220

SERIE E N. The E N series clamps use Hall-effect technology for the measurement of AC and DC currents from several milliamps to over 100 A.

MIT400/2. CAT IV Insulation testers MIT430/2: CAT IV Insulation testers

79/26 Series III Multimeter

1507/1503. Insulation Testers. Technical Data. Features and benefits:

Data sheet IDM 99III Digital Multimeter

INSTRUCTION MANUAL. Model Autoranging DMM ProbeMeter TM. Measures voltage, resistance, frequency, capacitance, temperature, and duty cycle.

User's Guide. Extech 800 Series 1000 Amp Clamp Meters with IR Thermometer

Take the current. Clamp meters available for diverse applications and conductor diameters.

ENGLISH. Datasheet Stock No RS PRO IDM 99III Digital Multimeter. Feature: 6000 count digital display with 62 segment bar graph

Technical Data Sheet

MIT400 CAT IV Industrial Insulation Testers

OWNER S MANUAL HH0308C. AUTO-RANGING DC/True RMS AC DIGITAL MULTIMETER

Laboratory for Fundamentals of Electrical Engineering (Labor Grundlagen der Elektrotechnik) Equipment Manuals for use in laboratory for measurement

Data sheet IDM 98III Digital Multimeter

AC Clamp Meter + Phase Rotation Tester

User Guide. AC/DC Mini Clamp Meter. Model

DL6508 User's Guide. 1500Amp True RMS AC/DC Clamp Meter

MIT400 CAT IV Industrial Insulation Testers

ALPHA 50 MULTIFUNCTION METER (ALPHA SERIES)

EX350 Series USER GUIDE. True RMS Digital Multimeters. EX350 True RMS Digital Multimeter EX355 True RMS Digital Multimeter with Temperature

Insulation Testers and Earth Ground Testers

MIT400/2 CAT IV Insulation testers

NOTE: Fully read and understand this manual before using this Digital Multimeter.

ENGLISH. Datasheet Stock No RS PRO IDM 98III Digital Multimeter. Feature: 6000 count digital display with 62 segment bar graph

Fluke 1587 FC/1577 Insulation Multimeters

Operating Instructions METRA HIT 16I/L/T. Analog Digital Multimeter with Insulation Measurement /5.06

Digital Clamp Meter (TRMS) Model : 2727

10.00 (1/2) PAC series

User Guide. Digital AC/DC Clamp Meter Model 38394

METRA HIT 28C Calibrator, Multimeter and Milliohmmeter

User s Guide. Digital AC/DC Clamp Meter Model 38394

Digital Clamp Meter Model: &

Alpha 50. Technical Data Sheet. Special Features

TRMS LEAKAGE CURRENT CLAMP-ON METER 565

CL900. True RMS 1000V 2000A 60MΩ ENGLISH. INSTRUCTION MANUAL 2000A Digital Clamp Meter. Measurement Technology

METRAClip87 and 88 Clamp Multimeters

AC / DC STROOMTANG MULTIMETER NI 30 AC / DC CLAMP MULTIMETER NI 30. Handleiding / Manual

APPA 300 Series. The Most User-Friendly High Performance Multimeter

200Amp AC Clamp Meter + NCV Model MA250

Gamma 40/50/60/70. Technical Data Sheet. Special Features

2000 A AC TRUE RMS DIGITAL CLAMP METER WITH NON-CONTACT EF-DETECTION

Current Clamp. 210

BENNING. CM7 Electrical Tester. Service Information

USER MANUAL. Model MA A AC Clamp Meter DMM Model MA445 True RMS 400A AC/DC Clamp Meter DMM

Indeks: WMXXCMM60 Advanced Industrial Multimeter

2000 A DCA/ACA CLAMP + DMM,

PEN TYPE DIGITAL MULTIMETER OPERATION MANUAL T8211D

Specifications. 744 Users Manual

374/375/376 Clamp Meter. Users Manual

USER'S MANUAL. ACD-6 Pro. ACD-6 TRMS Pro. Versatile Clamp-on Multimeter Series

AC/DC CLAMP METER USER S MANUAL

770E DIGITAL MULTIMETER OPERATOR S MANUAL

MIT400/2 CAT IV Insulation testers

Fluke 370 FC Series True-rms Wireless AC/DC Clamp Meters

METRA 22 26S/M Analog-Digital Multimeters with Signal Generator

INSTRUCTION MANUAL ACD-10 PRO & TRMS PRO

Fluke 370 FC Series True-rms Wireless AC/DC Clamp Meters

USER'S MANUAL DMR-6700

ACA LEAKAGE TESTER OPERATION MANUAL. auto range, true rms. Model : DL-9954

ACD-3300 IND ACDC-3400 IND

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL: MODEL: Multimeter Service Information

Transcription:

Technical Data Sheet Delta 1000/300 Delta 1000/300 measures important electrical parameters like Current (TRMS), Current, Voltage(TRMS), and Voltage. It also features Capacitance, Ohm & Continuity, frequency, and Duty cycle and temperature. Special eatures Unique Design Delta 1000A/300A is a highly innovative design for features those increases safety and comfort of user. Rotating clamp jaws facilitate the at physically awkward positions, vertical bus bars, conductors placed at positions dif cult to access. Location and design of trigger eliminates fatigues caused by single nger operation. It allows spreading the force required to open the jaws over more than one nger to ensure comfortable operation. Clamp jaws can be opened or closed with the trigger placed at bottom side away from the jaws. This allows the user to place his/her hand at safer distance from live conductor. This greatly reduces exposure of human beings to electrical shocks

Application Delta 1000/300 measures important electrical parameters like Current (TRMS), Current, Voltage(TRMS), and Voltage. It also features Capacitance, Ohm & Continuity, frequency, and Duty cycle and temperature. Product eatures Large Jaw Opening Narrow Body High Accuracy for low current True Root Mean Square (TRMS) Measurement on Variable requency Drives User selectable Backlit (Optional) Temperature AUTO POWER O or Delta 1000A - Jaw opening of 51mm for standard wire diameter of 50mm and for Delta 300A - Jaw opening of 41mm for standard wire diameter of 40mm for 300A The clamp meter can measure accurately at not only the High currents but also Low current ranges. Clamp meter measures signal s root-mean -square value accurately irrespective of the shape of input waveform. The clamp meter can measure accurately on variable frequency drives (VD) and UPS. It is possible to conduct using the clamp meter during night time in darkness with the help of Backlit. The back lit can be switched ON or O by pressing a single key. Temperatures from -200 to 800 C using Pt 100 and Pt 1000 sensors. In order to save the power of the Batteries, the clamp meter will automatically shut O if it detects no activity for utes. CONTINOUS ON MODE DATA Hold MIN,MAX NULL ZERO Correction for Resistance NULL ZERO Correction for Capacitance AUTO and MANUAL ranging modes Diode Measurement Protection from dust and water Applicable International Safety standards In this mode, AUTO POWER O is disabled. By pressing DATA HOLD button, reading on the display can be latched for Hands free operation. By pressing MIN/MAX button, the clamp meter will start recording latest Minimum and Maximum readings or Low ohm, the lead resistance can be compensated by pressing the shift key (Yellow Key) Null zero connection for capacitance. or n range, stray capacitance can be compensated by shift key (Yellow Key) In AUTO ranging mode the instrument automatically selects the range with best resolution depending on the applied input. In MANUAL ranging mode range is user selectable using MAN key. or testing diode and transistors, diode function is available. IP20 for terminals as per IEC60529 600 V CAT IV/1000V CAT III as per International Safety standard IEC 61010-1- 2010 Analog Scale Reference conditions for Accuracy Reference temperature Relative Humidity Waveform of measured quantity Input frequency Battery Voltage Weight Weight Warranty Warranty 23 C ± 2K 45%...55% RH Sinusoidal 50 or 60 ±2% 8 V ± 0.1 V 0.6 Kg 1 year Display Number of digits Maximum count Over range indication Polarity indication Environmental Operating temperature Storage temperature Relative humidity Terminal Protection 3 ¾ digits. 3100 counts. OL is displayed. sign is displayed for functions, if positive pole is at. -10 to +55 C -20 to +70 C 0... 90% non condensing IP50 for Housing and IP20 for terminals www.sifamtinsley.com Page 1 of 4

Battery Battery Voltage Battery type Battery Life Applicable Standards 9 V Manganese Dioxide Cell as per IEC622, alkaline manganese cell as per IEC 6LR 61 Minimum 220 hours on Vdc, Adc, 80 hours on Vac, Aac. EMC IEC 61326: Class B Immunity IEC 61000-4-2 8 KV atmosphere discharge, 4 KV contact discharge IEC 61000-4-3 : 3 V/m IEC 61010-1-2010 Safety IP for water & dust Pollution degree 2 Installation category High Voltage Test IEC60529 IV 6.7 kv, 50 for 1 minute between housing and input. 3.7 kv, 50 for 1 minute between housing with jaws and input. function V dc V ~ Ω range Resoluti on Input impedance Intrinsic error of digital display ± ( % of rdg + digit) at reference condition 30.00 mv 10 µv >10 GΩ //<40p 0.5 + 3 2) 300.0 mv 100 µv >10 GΩ //<40p 0.5 + 3 3.000 V 1 mv 11 MΩ // <40p 0.25 + 1 30.00 V 10 mv 10 MΩ // <40p 0.25 + 1 300.0 V 100 mv 10 MΩ // <40 p 0.25 + 1 1 V 10 MΩ // <40p 0.35 + 1 3.000 V 1 mv 11 MΩ // <40p 30.00 V 10 mv 10 MΩ // < 40p 0.75 + 2 (10.300 Digit) 300.0 V 100 mv 10 MΩ // <40p 0.75 + 1 ( > 300 Digit) 1V 10 MΩ // <40p No load voltage 30.00 Ω 10 mω Max. 3.2 V 0.5 + 3 2) 300.0 Ω 100 mω Max. 3.2 V 0.5 + 3 3.000 KΩ 1Ω Max. 1.25 V 0.4 + 1 30.00 KΩ 10 Ω Max. 1.25 V 0.4 + 1 300.0 KΩ 100 Ω Max. 1.25 V 0.4 + 1 3.000 MΩ 1 KΩ Max. 1.25 V 0.6 + 1 30.00 MΩ 10 KΩ Max. 1.25 V 2.0 + 1 Over load value Sine wave Sine wave Over load c apacity 1) Overload duration Continuously 2.000 V 1 mv Max. 3.2 V 0.25 + 1 Delta 1000A~/ Delta 300A~/Adc Adc 2 to 3 00.0 A 10 00 A 0.1 A 1 A ----- ----- 0.2 to 30.0A 0.1 A ----- 300.0 A 1 A ----- 1.5 % of range + 5 Digits 1100 A Continuously range Resolution Discharge resista nce U 0 max. Intrinsic error of digital display ± ( % of rdg + digit) at reference condition 30.00 n 10 p 250 KΩ 2.5 V 1.0 + 3 2) 300.0 n 100 p 250 KΩ 2.5 V 1.0 + 3 3.000 µ 1 n 25 KΩ 2.5 V 1.0 + 3 30.00 µ 10 n 25 KΩ 2.5 V 3.0 + 3 f min V dc f min V ~ 300.0 0.1 1 45 3.000 K 1 1 45 30.00 K 10 10 45 100.0 K 100 100 100 % 2.0...98.0% 0.1 % 2 - ºC -200.0... Pt +200.0 ºC 100 +200.0... +850.0 ºC -100.0... Pt +200.0 ºC 1000 +200.0... +850.0 ºC 0.5 + 1 3) 2 1k ± 5 Digit 1 k 10 k; ± 5 Digit / k 0.1 ºC 2 Kelvin + 5 Digit 5) - - 0.1 ºC 1.0 + 5 5) 0.1 ºC 2 Kelvin + 2 Digit 5) - - 0.1 ºC 1.0 + 2 5) Over load capacity 1) Over load value Sine 3 k 1000 v 30 k; 300 V 100 k 30 V Sine Over load duration Continuously www.sifamtinsley.com Page 2 of 4

1) At 0º. + 40 ºC 2) With zero adjustment, without zero adjustment + 35 digits 3) Range : 3 V ac/dc: Ue = 1.5 V eff/rms 100 V eff/rms 30 V ac/dc: Ue = 15 V eff/rms 300 V eff/rms 300 V ac/dc: Ue = 150 V eff/rms eff/rms On the range 3 V dc, square wave signal positive on one side 5 15 V, f = const., not 163.84 or integral multiple. 5) Without sensor Measured Quantity/ Measuring Range 30/300 mv dc 1.0 + 3 3...300 V dc 0.15 + 1 dc 0.2 + 1 V ~ 0.4 + 2 2) 30 Ω 0.15 + 2 Temperature 0 ºC 300 Ω 0.25 + 2 +21 ºC 3 KΩ 3 MΩ 0.15 + 1 and 30 MΩ 1.0 + 1 requency of the measured quantity +25 ºC +40ºC > 65...400 >400 1 K 2) 30 n 3 μ 0.5 + 2 30 μ 2.0 + 2 0.5 + 1 % ± 5 digits -200 +200 ºC 0.5 K + 2 +200 +850ºC 0.5 + 2 3 300 V ~ 30 A ~/ A 300 A ~/ A 0 300 A ~/ A 1000 A ~/ A 0 1) Variation ± (.% of rdg. +.digits) 2.0 + 3 >65 1 K ~ 3.0 + 3 15 <45 >66 400 1...3 Wave form of the Crest factor C measured quantity 3) 1...5 Delta 1000A - Delta 300A - A ~ 1.0 % of range + 1 V ~ A ~ ± 1 % of rdg ± 3 % of rdg Battery Voltage V 2 Digit V~ 4 Digit 5) < 7.9 V A/A 8 Digit > 8.1 V 10.0 V 30Ω / 300 Ω/ C 4 Digit 3 kω 30MΩ 3 Digit n, μ 10 Digit 10 Digit % 10 Digit www.sifamtinsley.com Page 3 of 4

Measured Quantity/ Measuring Range 1) Variation ± (.% of rdg. +.digits) 75% V~,V A~, A Relative humidity 3 Days Ω 1 х intrinsic error Meter off % 0 C HOLD - -- ± 1 digits MIN/MAX - V ac/dc, A ~, A ± 2 digits 1) With temperature: Error data apply per 10 K change in temperature. or Aac/Adc error data apply per K change in temperature. With frequency: Error data apply to a display from 300 digits onwards. 2) With zero adjustment. 3) With unknown waveform (crest factor C > 2), measure with manual range selection With the exception of sinusoidal waveform. 5) After the symbol is displayed Ordering Information Product Code DT 20- X X X 0000000000 Type Clamp 1000A / 1 Clamp 300A / 3 Probe Set Normal N ine Tip Backlit With Backlit Without Backlit B Z Sifam Tinsley Instrumentation Inc. 3105, Creekside Village Drive, Suite No. 801, Kennesaw, Georgia 30144 (USA) E-mail Id : psk@sifamtinsley.com Web : www.sifamtinsley.com Contact No. : +1 404 736 4903 Sifam Tinsley Instrumentation Ltd Unit 1 Warner Drive, Springwood Industrial Estate Braintree, Essex, UK, CM72YW E-mail: sales@sifamtinsley.com Web: www.sifamtinsley.com/uk Contact: +44(0)1803615139 www.sifamtinsley.com Page 4 of 4