MODEL HD 300 EM PHALANX TYPE BARRICADE SYSTEM Electro-Mechanical Power System. Procurement Specification

Similar documents
RECTANGULAR RAPID FLASHING BEACON WITH LARGE LED ARRAYS TAPCO RRFB-XL : Solar Powered; Extra Large LED Arrays, Wirelessly Synchronized

Distribution/Substation Transformer

DPM - Mesta Electronics, Inc. Low Voltage Active Harmonic Filters

Operation Manual February Opticom Infrared System

CS-200. PORTABLE TRAFFIC LIGHT CONTROLLER (Software 1.05) OPERATION AND SERVICE MANUAL

M-0418 REV:0

The NOVA Recloser shall be designed and tested in accordance with the following standards as applicable:

SUGGESTED SPECIFICATION for Series 300 Automatic Transfer Switches

SPECIFICATION FOR HORIZONTAL AIRFLOW OUTDOOR RESISTIVE LOAD BANK

RCF 3.4. Portable Traffic Signal - Technical Specifications. North America Traffic Inc REV#

With Audible Detect Signal

MICHIGAN DEPARTMENT OF TRANSPORTATION SPECIAL PROVISION FOR WIRELESS INTERCONNECT FOR SIGN MOUNTED FLASHER

Keyed latch. Cover. Service Outlet 115VAC, 15A. Plastic base. Unpack. Operator. the Operator

Industrial Area Crossing Signal System

SPECIAL SPECIFICATION 8590 Emergency Vehicle Traffic Signal Priority Control System

INSTALLATION GUIDE. Version 2.0

SECTION LOW VOLTAGE ACTIVE HARMONIC FILTER SYSTEM NEMA 1 ENCLOSED

ESD Tester for Powders

1 of REV:0

UNIFIED FACILITIES GUIDE SPECIFICATIONS

MGM Transformer. Vacuum Pressure Impregnated (VPI) Dry-Type Substation Transformer Specification Guide

Specifications. S&C BankGuard Plus Controls. For Substation Capacitor Banks and Shunt Reactors. Conditions of Sale

Canoga Traffic Sensing System

5 yr. Station Level Paging Adapter. Model 300PBX-SC LINKS TELEPHONE TO SELECTONE OR PUBLIC ADDRESS SYSTEM. dedicated extension

Pioneers in Gate Design

Section 11 Electronic Position Controls & Encoders

SPECIFICATIONS FOR THE MANUFACTURE AND DESIGN OF PRECAST THREE SIDED ARCH STRUCTURES, WINGWALLS AND HEADWALLS

EMMEGI ARCHITECTURAL FENCING MASTER SPECIFICATION SECTION METAL FENCING, GATES & RAILING SYSTEM PART 1 GENERAL

DIVISION 11 EQUIPMENT SECTION PHOTO DARKROOM FUME EXHAUST VENT-HOODS

SINGLE-PHASE VSV SWITCH

Issue Date: Effective Date: Supersedes: S-E-06 (rev. 6)

SECTION SWINGING AUTOMATIC ENTRANCES IN-GROUND, AUTOMATIC SWING DOOR OPERATOR CONVERTER ADAPTED TO BROOKFIELD NB-500 EXTREME DUTY OPERATOR

SECTION SWINGING AUTOMATIC ENTRANCES

Model 935A. Dual Tone Sender INSTRUCTION MANUAL

S&C Series 2000 Circuit-Switchers Outdoor Transmission (69 kv through 230 kv)

MATERIAL COMBINATION NUMBER 2: Corrosive environment requiring harder, wear-resistant seating faces and resistance to dezincification.

Draft. Not yet Approved

Heritage MedCall. Sentry E-Call Model HM-527 Resident Host Panel

AC and DC solutions- Multiple AC and DC solutions available, please contact factory for your application.

Electro-Magnetic Flowmeters COPA-XE

MEDIUM DUTY CAST IRON SLIDE GATES SERIES 20-10C

SECTION CABLE TRAYS

C-Band Redundant LNA Systems

LED Beacons

Operation Manual January Opticom Infrared System. 700 Series Emitters Detectors Phase Selectors Discriminators Accessories

Title: Southern States Type SLS Smart Sectionalizer Solid Dielectric Three Phase Sectionalizer. Product Specification Guide TABLE OF CONTENTS

PRODUCT INFORMATION Penco Wide-Span Shelving

Band-Master ATS Nano Pneumatic Banding Tool Operating Instructions

STATE OF OHIO DEPARTMENT OF TRANSPORTATION SUPPLEMENTAL SPECIFICATION 919 RAILROAD PREEMPTION INTERFACE. January 15, 2016

Architectural/Engineering Specification for a. Microwave Perimeter Intrusion Detection System

Siemens ST950 & ST900 Statement of Compliance Against TR 2513 Issue A, September 2005 Performance Specification for Wig Wag Signal Control Equipment

LBI-31564A. Mobile Communications. DELTA - SX MHz RADIO COMBINATIONS (NEGATIVE GROUND ONLY) Maintenance Manual

ASX SERIES PACIFIC OPERATION MANUAL AC POWER SOURCE POWER SOURCE

Improve asset protection and utilization

A. Product Data: For each electrical identification product indicated.

Tarheel Antennas, Inc.

NORTH AMERICAN STEEL INNOVATIVE STORAGE SOLUTIONS OUR S T R E N G T H IS OUR PEOPLE NORTH AMERICAN RACK

Michigan State University Construction Standards SWITCHBOARDS, PANELBOARDS, AND CONTROL CENTERS PAGE

Laserglow Product Datasheet

WIRELESS INSULATOR POLLUTION MONITORING SYSTEM

Power Processor - Series 700F 10KVA to 150KVA

Analog Inputs and Outputs

MH Table of Contents Standard Title/Scope Page Table of Contents SCE Public

Tarheel Antennas, Inc.

PUBLIC VERTICAL PLATFORM LIFT PLANNING GUIDE

SECTION AUTOMATIC TRANSFER SWITCH

WESTERN UNDERGROUND COMMITTEE GUIDE 2.6 (2.6/00/0868)

X-Band Redundant LNA Systems

The Torxis Linear Servo meets the following environmental conditions:

NEW. Lumenfacade Remote. Lumenfacade Stand. Alone NEW NEW. Lumenfacade Remote. LumenfacadeFX RGB. Lumenfacade. Lumenfacade Interior RGB RGB RGB NEW

Installation & Operation Manual SAGA1-K Series Industrial Radio Remote Control

EXECUTE Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

Installation Manual. UL 325 Compliant. For Pre-2016 Convenience Open Operators ONLY

SINGLE-PHASE VSV SWITCH

UBC Technical Guidelines Section Edition Medium-Voltage Transformers Page 1 of 5

UNIFIED FACILITIES GUIDE SPECIFICATIONS

WAL-MART SUPERCENTER # ; Milwaukie, OR: SPECIFICATIONS. Revisions to Specification Fence

4000 Watt - Metal Halide - Three Stage Light Tower - 30 Feet

MobileRadio. Owner'sManual

LA-5000 SERIES LINEAR VALVE ACTUATORS

SECTION STRUCTURAL STEEL. A. PART A and DIVISION 1 of PART B are hereby made a part of this SECTION.

2.14 Main Cable Type HO7RN-F4G10-15 Metres each Chiller Tank Capacity- 75 Litres Compressor- 3.5 Tons Refrigeration type

SECTION TRANSFORMERS

SECTION CHAIN LINK FENCING AND GATES AND SOFTBALL BACKSTOP

Wiring Instructions for 10, 16 & 20 Function, 92 & 93 Series, FET Receivers.

Low Voltage Power Factor Correction Equipment Specifications Automatic, Automatic Detuned, Automatic Tuned

SECTION 16322B SUBSTATION TRANSFORMERS DRY-TYPE

TOA PROFESSIONAL POWER AMP

CVC L ANTENNA GATES GATES RING. Designed for FM Stereo and Multiplex broadcasting Shunt Fed -Binary Adjustment (Pat. Pending).

RLT Rainfall Transmitter Instruction Manual

Series 1600 WeatherGuard Dock Enclosure

SPECIAL SPECIFICATION 6734 RS-232 Optical Modem

Guide To Returning Your Satellite Modem and Radio Assembly Model: HN9000

WHITE PAPER BENEFITS OF OPTICOM GPS. Upgrading from Infrared to GPS Emergency Vehicle Preemption GLOB A L TRAFFIC TE CHNOLOGIE S

SPECIFICATION, CONTROLS AND ACCESSORIES

APPENDIX H PRICE WORKSHEETS, REVISED 12/26/15 1. BATTERIES, MODULAR FLOODED LEAD-ACID 2. BATTERIES, MODULAR VALVE REGULATED LEAD ACID

Yagi and Omni Antennas Installation Manual

PUBLIC VERTICAL PLATFORM LIFT PLANNING GUIDE

MC108A-2 RF MULTI-COUPLER USER S GUIDE

ZT-30 ZeroTEM TRANSMITTER MANUAL

Transcription:

MODEL HD 300 EM PHALANX TYPE BARRICADE SYSTEM Electro-Mechanical Power System Procurement Specification Copyright 2014 Delta Scientific Corporation Page 1 of 10

SYNOPSIS OF FULL SCALE CRASH CERTIFICATION FULL SCALE CRASH TEST CERTIFICATION The HD 300 Barricade System has been tested and certified to the highest United States Vehicle Barricade Standard. This barricade exceeds ASTM F 2656-07 M50 P1. Testing by an independent testing laboratory confirms that it will stop and destroy a heavily loaded truck moving at high speeds and remain standing for a second attack. 1.0 SCOPE Full Scale Crash Test Certification This specification defines the procurement of a PHALANX SYSTEM, Model HD 300 EM, consisting of (one, two, three or four) vehicle Barricade(s) operating (independently or in sets of two, three or four) Barricade(s), An independent Electromechanical actuator and proprietary counterbalance system is installed in each barricade. POWER SYSTEM, the CONTROLS AND LOGIC CIRCUITS, FEATURES and OPTIONS as defined herein. SAFETY AND ENVIRONMENTAL OPTIONS include signal lights, gate arm barriers; safety loops; IR beams, heaters and sump pumps. TOUCH SCREEN CONTROL PANELS or PUSH BUTTON CONTROL PANELS. Remotes and Masters. 2.0 SITE SPECIFIC REQUIREMENTS 2.1 The Barrier plate when installed shall provide a level or co-planar surface relative to surrounding roadways. (Ref. Std. Specifications for Construction of Roads and Bridges on Federal Highway Projects FP-96) 2.2 The Barricade plate within itself shall be continuous with no welded joints, removable sections or bolted-in place road panels with the exception of a small access portal. Copyright 2014 Delta Scientific Corporation Page 2 of 10

2.3 The Barricade shall safely handle heavy truck traffic with loads up to 66,000 lbs. per axle. 2.4 SYSTEM CONFIGURATION 2.4.1 BARRICADE(S) 2.4.2 Barricade Construction. Barricade shall be a shallow frame below grade assembly that can be cast in a foundation of 24 inches [610 mm] in depth. The assembly shall have a heavy steel ramp weldment capable of being rotated to an above grade position. The guard position shall present a formidable obstacle to approaching vehicles. Upon impact, forces shall be first absorbed by the Ramp weldment and then transmitted to the foundation of the unit. 2.4.3 Barricade Height (Deployed). Height of the Barricade shall be 39 inches [1,0 M] inches as measured from the top of the foundation frame to the top of the barrier inclusive of the top road plate. 2.4.4 Barricade Ramp Length. Barricade ramp length shall be 109 inches [2,77 M] or a minimum length of 60 inches [1,52 M].). 2.4.5 Foundation Depth. The frame of the Barrier shall be 24 inches [610 mm]. 2.4.6 Safety / Visibility Panel. Descending from the front edge of the Barrier Ramp shall be a rigid panel containing three or more red warning lights. The panel shall be continuous across the full width of the Barrier Ramp. The height of the panel shall be 22 inches (558 mm). The Safety Visibility Panel shall have red/white (alternately yellow/black) diagonal stripes. 2.4.7 Serviceability of Safety / Visibility Panel. The panel and side skirts, mounted on the ramp weldment shall be readily removable to facilitate Barrier Maintenance and Service using standard hand tools. 2.4.8 Finish. The roadway plates shall be painted white [specify optional color(s)]. Finish. Coatings shall be checked against ordering information and shall be workmanlike in appearance. Copyright 2014 Delta Scientific Corporation Page 3 of 10

2.5 Electrical Mechanical System (EMS) The EMS shall include an electro-mechanical actuator, internal encoder, variable frequency drive, programmable logic controller, power cables and Delta counter balance system, command and control station(s), control logic, interconnecting elements and reservoir(s). 2.5.1 Main Power. The EMS shall be fed from (specify actual site voltage, phase and frequency, i.e. 230/3/60 as an example). 2.5.2 Power Off Operation. Back up batteries and counter balance reservoir shall be sized to allow operations of the barrier (s). 2.5.3 Hourly Throughput Rate, The actuator and accessories shall be sized to maintain a through put rate of per hour of the Barrier(s). 2.5.4 Peak Operating Rate, The actuator and accessories shall be sized to maintain a through put rate of per hour of the Barrier(s) for a period of minutes. 2.5.5 Construction. The electro-mechanical actuator and cables shall be rated IP-67. The actuator controls, system components, counter balance and power off equipment shall be mounted and wired on integral steel skid(s). Dimension to be defined for site specific applications. The controls shall be installed indoors or in an optional weather resistant enclosure see 3.6. 2.5 DELTA PROPRIETARY COUNTERBALANCE 2.6.1 The Delta Proprietary Counterbalance shall serve multiple purposes; first to eliminate tension or compression springs in counter balancing the barrier plate, and second to reduce the load and wear on the electro-mechanical actuator. 2.6.2 The Delta Proprietary Counterbalance shall, during normal operation provide a constant assist to deploy and retract the barrier. 2.6.3 Delta Proprietary Counterbalance shall be a self-contained and sealed device. Copyright 2014 Delta Scientific Corporation Page 4 of 10

2.7 CONTROL AND LOGIC CIRCUITS The following circuits and control stations shall be furnished: 2.7.1 Control Circuit. A control circuit shall be provided to interface between all Barricade control stations and the electromechanical actuator(s). This circuit shall contain all relays, timers and other devices necessary for the Barricade operation. 2.7.2 Voltage. The control circuit shall operate from a 120/240 volt, 50/60 Hz supply (optionally 24 VDC). An internally mounted transformer shall reduce this to 24 VDC for all external control stations. 2.7.3 Power Consumption. The control circuit power consumption shall not exceed 30 amps. 2.7.4 Construction. The control circuit shall be mounted in a general purpose enclosure. All device interconnect lines shall be run to terminal strips. 2.8 Touch Screen Control Panels (Optional Alternative to Push Button Controls, Select Type) Touch Screen Panels. Touch Panel controls can be provided as an option. Touch Screens are available in standard sizes from 8 to 15 inches in a rack mount or table top console. 2.8.1 Configurations. The master and slave Touch Screens have all the standard functionality of the Remote Control panels in sections 2.9 and these additional features: 2.8.2 Data Logging Records and maintains a time stamped record of all command signals issued from the Touch Panel and any Auxiliary Controls. This record log can be easily exported into a spreadsheet on computers. 2.8.3 Layering Locations with multiple barriers can be presented in a layered fashion allowing control from one convenient panel opposed to multiple panels or one large pushbutton panel. 2.8.4 Customizable Each location allows the end user to change the name of the location and barrier to correspond with the site s naming. 2.8.5 Cycle Count and Alarms The Touch Screens monitor the number of cycles a barrier completes and will alert the operator when maintenance is due (based on cycles or days depending on site). Copyright 2014 Delta Scientific Corporation Page 5 of 10

2.8.6 Passwords The Touch Screens offer passwords that can be set up at different operating levels allowing access to differing functional configurations per user 2.8.7 Video Video Touch Screen models are available for control. This option displays the vehicle barricade directly above the control buttons which operate the barricade. Having a live feed of the barriers allows the operator to more safely monitor and control the area from a distant remote location. 2.8.8 Ethernet and Fiber Optic communications shall be specified if required. 2.9 Push Button Control Panels (Optional Alternative to Touch Screen Select Type) Push Button. Specify Remote Control Master and the number of slave control panels or EFO push buttons required. 2.9.1 Remote Control Master Panel. A remote control master panel shall be supplied to control Barrier function. This panel shall have a key lockable main switch with "main power on" and "panel on" lights. Buttons to raise and lower each Barrier (or set) shall be provided. Barrier "up" and "down" indicator lights shall be included for each Barrier (or set). The emergency fast operate circuit (EFO) feature shall be operated from a covered toggle switch (optionally a push button larger than the normal controls). The EFO shall be furnished with EFO active light and reset button. The remote control master panel shall have a key lockable switch to arm or disarm the remote slave panel(s). An indicator light shall show if the slave panel is armed. 2.9.2 Remote Control Slave Panel. A remote control slave panel shall also be supplied to control the Barrier operation. This panel shall have a "panel on" light that is lit when enabled by a switch on the remote control master panel. Buttons to raise or lower each Barrier (or set) shall be provided. Barrier "up" and "down" indicator lights shall be included for each Barrier (or set). The emergency fast operate (EFO) feature shall be operated from a push button larger than the normal controls (optionally a covered toggle switch). When the slave panel EFO is pushed, an EFO "active" lamp will light and operation of the Barrier(s) will not be possible until reset at the master panel. 2.9.3 Voltage. The remote control panel(s) shall operate on 24 VDC. 2.9.4 Construction. The remote control panel(s) shall be a standard 19 inch electronics rack type surface mount panel with all devices wired to a terminal strip on the back. Copyright 2014 Delta Scientific Corporation Page 6 of 10

2.9.5 (Option) Panel(s) shall be equipped with a timer circuit to notify the operator via an annunciator "squealer" that the Barrier has been left in the down position for too long a time period. The time interval shall be customer selectable. 3.0 ACCESSORY EQUIPMENT (Any or all of the following may be selected): 3.1 Enhanced Power Off Capability. An optional redundant pneumatic power system is available to cycle the barricade in the case of extended power outages. 3.2 Electro-Mechanical Signal Gate. An electrically operated wood arm signal gate shall be supplied to alert vehicle drivers of the Barricade position. The gate operate shall interface with the Barricade at the control circuit. The control circuit shall close the gate at the Barricade "up" command and remain closed until the Barricade is fully lowered. The wood arm shall be foot (6 to 12 foot can be specified) long and be striped with reflective yellow/black tape. The gate assembly shall be mountable directly to the roadway surface. 3.3 Stop/Go Traffic Lights. Red/Green 8 inch stand alone traffic lights shall be supplied to alert vehicle drivers of the Barricade position. The green light shall indicate that the Barricade is fully down. All other positions shall cause the light to show red. Brackets shall be supplied to allow light(s) to be located on a (3.5 inch OD post) (wall) (3.5 inch OD post - back to back). The light operating voltage shall be 120 Volt (alternately 240 Volt), power consumption 40 watts per light. 3.4 Sump Pump. A self priming sump pump shall be supplied to drain water collected in the Barricade foundation. The pump shall have the capacity to remove inches per minute of rainfall a distance of feet to customer supplied discharge drain. Pump operating voltage shall be 120/1/50-60 (alternately 240/1/50-60). 3.5 Safety Interlock Detector. A vehicle detector safety loop shall be supplied to prevent the Barricade from being accidentally raised under an authorized vehicle. The detector shall utilize digital logic have fully automatic tuning for stable and accurate long term reliability. The output of the detector shall delay any Barricade rise signal (except for EFO command) when a vehicle is over the loop. Copyright 2014 Delta Scientific Corporation Page 7 of 10

3.6 Heavy Duty Weather Resistant EMS Enclosure. A lockable weather resistant enclosure shall be provided for the EMS fabricated from not less than 0.25 inch [6,35mm] steel plate. The design shall provide for easy access to the EMS for maintenance and emergency operation of the power system. Enclosure shall be provided with a corrosion resistant coating and shall be 36 inches W x 18 inches D x 58 inches H [914 mm W x 457 mm D x 1476 mm H]. 4.0 PERFORMANCE 4.1 Experience. Barricade and auxiliaries shall be of proven design. Manufacturer shall have 17,000 Phalanx type Barricades in field operation for a minimum of 20 years with Documented field experience for all major components and design features. 4.2 Qualification Tests. Barricade design shall have successfully passed full scale crash test conducted by qualified independent agencies. 4.3 Performance Evaluation. The Barricade shall have successful performance evaluations based on full scale testing of vehicles as either defined by the agency or as set forth in the specifications noted in 4.4 4.4 ASTM F 2656-07 M50 4.5 Second Strike Capability. After the full scale test the barricade and foundation remained in place and ready for a second attack. 4.6 Barricade(s) shall be designed to destroy a non-armored or non-tracked vehicle at energy levels of up to 5,400,000 foot pounds (7,340,000 Joules), i.e. - 65,000 pounds at 50 mph (29,500 kg at 80 Kph) 50,000 pounds at 67 mph (22,680 kg at 108 Kph] 5.0 SPEED OF OPERATION. 5.1 Normal Operation. Each Barricade (or set) shall be capable of being raised or lowered in 3 to 5 seconds (adjustable) when operated at a repetition rate not greater than specified in paragraph 5.3. Barricade direction shall be instantly reversible at any point in its cycle from the control stations. Copyright 2014 Delta Scientific Corporation Page 8 of 10

5.2 Emergency Fast Operation. Barricade shall rise to the guard position from fully down in 1.5 seconds when the emergency fast operate button is pushed. Barricade shall remain in the up and locked position (normal up/down buttons inoperable) until the EFO condition is reset. 5.3 FREQUENCY OF OPERATION. Barricade shall be capable of (specify up to 120 cycles per hour) complete up/down cycles per hour. 6.0 ENVIRONMENTAL DATA (Please supply the following): Barricade shall operate satisfactorily under the following environmental conditions: 6.1 Extremes in temperature Yearly maximum drybulb temp f/c Yearly minimum drybulb temp f/c 6.2 Rainfall Yearly average inches Maximum expected hourly rate inches/hour 6.3 Snowfall Maximum expected hourly rate inches/hour Roadway will be (mechanically/manually/chemically) cleared. 7.0 QUALITY ASSURANCE PROVISIONS 7.1 Testing. Upon completion, the Barricade system will be fully tested in the manufacturer's shop. In addition to complete cycle testing to verify function and operating speeds, the following checks shall be made: 7.2 Identification. A nameplate with manufacturer's name, model number, serial number and year built shall be located on the control circuit. 7.3 Workmanship. The Barricade and subsystems shall have a neat and workmanlike appearance. 7.4 Dimensions. Shall be checked against drawings and ordering information. 7.5 Finish. Coatings shall be checked against ordering information and shall be workmanlike in appearance. Copyright 2014 Delta Scientific Corporation Page 9 of 10

8.0 PREPARATION FOR SHIPMENT 8.1 The Barricade system shall be crated or mounted on skids as necessary to prevent damage from handling. Lifting points shall be of sufficient structural integrity to enable the assembly to be lifted and transported by overhead crane or forklift without failure. 9.0 MANUFACTURER'S DATA 9.1 Drawings and installation data. The Barricade system drawings and installation, maintenance and operating manuals shall be sent to purchaser within 4 weeks of order. additional copies shall be supplied (1 copy supplied at no cost). 10.0 DISCLAIMER 10.1 Please note - careful consideration must be devoted to the selection, placement and design of a Barricade installation. Just as in the case of any Barricade system, perimeter security device or security gate that blocks a roadway or drive, care must be taken to ensure that approaching vehicle as well as pedestrians are fully aware of the Barricades and their operation. Proper illumination, clearly worded warning signs, auxiliary devices such as semaphore gates, stop-go signal lights, audible warning devices, speed bumps, flashing lights, beacons, etc. should be considered. Delta has information available on many such auxiliary safety equipment not specifically listed herein. It is strongly recommended that an architect and or a traffic and or safety engineer be consulted prior to installation of a Barricade system. Delta will offer all possible assistance in designing the operating equipment, controls and the overall system but we are not qualified nor do we purport to offer either traffic or safety engineering information. 11.0 PROCUREMENT SOURCE 11.1 The Model HD 300 EM Phalanx Barricade System shall be purchased from: DELTA SCIENTIFIC CORPORATION 40355 Delta Lane Palmdale, California, 91355, Phone (661)575-1100 FAX (661)575-1109 Email info@deltascientific.com www.deltascientific.com Phalanx is a registered trademark of Delta Scientific Corporation, Palmdale, California, Copyright 2014 Delta Scientific Corporation Page 10 of 10