TEST REPORT Title 47-Telecommunication

Similar documents
D. Guarnone (verifier)

TEST REPORT. Information technology equipment

TEST REPORT. EN / EN Information technology equipment Radio disturbance / Immunity characteristics Limits and methods of measurement

CENTRE OF TESTING SERVICE INTERNATIONAL

EMI T E S T R E P O R T

EMI -- T E S T R E P O R T

FCC TEST REPORT On Behalf of GZTOD.CO., LTD The Multifunctional Platooninsert Model No.: YA30WSL-6AU6U

EMI T E S T R E P O R T

CENTRE OF TESTING SERVICE INTERNATIONAL

REVISION HISTORY. The revision history for this document is shown in table. HCT-EM-1801-FC037 January 22, 2018 Initial Release

TABLE OF CONTENTS. Report No.: SH E03 1. TEST RESULT CERTIFICATION...3

FCC TEST REPORT On Behalf of. Global Tech China Limited. Solar Light(Large)/28W,16W. Model No.: Additional Model No: Please Refer To Page 15

Electromagnetic Compatibility Test Report FCC test results of an automatic dog brush, model EUT: Type 1 AC/DC adaptor: SYS W2E

Test Report: 5R Champlain Street Dieppe, New Brunswick Canada E1A 1P6. Model Number: Verification

Test Report: 4R Champlain Street Dieppe, New-Brunswick Canada E4P 8L6. Model Number: Verification

FCC TEST REPORT. SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd.

Dongguan Nore Testing Center Co., Ltd. Report No.: NTC F TABLE OF CONTENTS

Via del Carroccio, 4 I Biassono (Italy) TRFFCC

TEST REPORT CONCERNING THE COMPLIANCE OF PART 15 JBP

RF test report AU01+W02

f02 January 11, TÜV Rheinland Nederland B.V. P.O. Box AA Leek (NL) Eiberkamp VT Leek (NL)

Page 1 of 51 Report No.: T TEST REPORT FCC ID: 2AGJ5WAP-30. In Accordance with: FCC PART 15, SUBPART C : 2015 (Section 15.

FCC Part 15 Subpart B

FCC 47 CFR PART 15 SUBPART B TEST REPORT SHENZHEN EAGLE TECHNOLOGY CO., LTD Mirror photo booth Model No.: EAGMR

King Pigeon Communication Co., Limited

FCC PART 15 SUBPART C TEST REPORT

FCC Verification TEST REPORT

FCC Test Report. Report No.: AGC FE08. Attestation of Global Compliance (Shenzhen) Co., Ltd

Nemko Canada Inc., 303 River Road, R.R. 5, Ottawa, Ontario, Canada, K1V 1H2

FCC REPORT. 570 E1 Camino Real #200, Redwood City, CA 94063, United Manufacturer:

FCC PART 15 SUBPART C TEST REPORT FCC PART

FCC Part 15B TEST REPORT

TEST REPORT. For RFID READER/WRITER. In conformity with. FCC CFR 47 Part15 Subpart C

RF Emissions Test Report To Determine Compliance With: FCC, Part 15 Rules and Regulations

Chapter I - Federal Communications Commission Subchapter A - General Part 15 - Radio Frequency Devices Subpart C - Intentional Radiators

TEST REPORT FROM RFI GLOBAL SERVICES LTD

FCC 47 CFR PART 15 SUBPART B CERTIFICATION TEST REPORT FOR a/b/g/n/ac 3X3 WLAN + Bluetooth Combo PCI-E Mini Card MODEL NUMBER: BCM94360CS

FCC 15B Test Report. : BTv4.0 Dual Mode USB Dongle. Address : Thompson Ave. / Lenexa, Kansas / / USA

MARKING / FCC. Test Report n FCC Rev. 01

TEST REPORT. No.I15N01324-EMC. for. Huawei Technologies Co., Ltd. Smart Phone. Model Name: HUAWEI CUN-L03,CUN-L03. Marketing Name: HUAWEI Y5II

FCC PART 15, CLASS B MEASUREMENT AND TEST REPORT. NanJing JingZe Lighting Technology Co.,Ltd

APPLICATION FOR CERTIFICATION On Behalf of Futaba Corporation Radio Control Model No.:T10CG-2.4G FCC ID:AZPT10CG-24G Brand : Futaba

MEASUREMENT REPORT FCC Part 15B

EMI -- T E S T R E P O R T

CERTIFICATE. Issued Date: Apr. 20, 2006 Report No.: 064L079-IT-US-P01V01

FCC 15B Test Report. : Bluetooth 4.2 Dual Mode USB HCI Module (Refer to item for more details) (Refer to item for more details)

EMI -- T E S T R E P O R T

TEST REPORT. Table of Contents

FCC CERTIFICATION TEST REPORT

FCC & RSS-216 (Class II Permissive Change) Wireless Power Transfer Report. for A Acer Incorporated

T A B L E O F C O N T E N T S DESCRIPTION PAGE

TEST REPORT FCC PART Jacky Chen (File administrators) Allen Wang (Test Engineer) Tracy Qi (Manager)

TEST REPORT. Issued for:

TABLE OF CONTENTS 1. GENERAL INFORMATION... 4

FCC REPORT. Dongguan Hele Electronics Co.,Ltd. * In the configuration tested, the EUT complied with the standards specified above.

STC Test Report. Date: Page 2 of 25 No.: MH The Hong Kong Standards and Testing Centre Ltd.

TEST REPORT. Building 6, XinXinTian Industrial Park, XinSha Road, ShaJing, Baoan District, ShenZhen, China. Shenzhen Innokin Technology Co.

FCC Test Report. Report No.: PTCDQ FC01

T E S T - R E P O R T. Test Report No (Edition 1) for RF340-R. Inductive Tag Reader

CERTIFICATE. Issued Date: Apr. 02, 2009 Report No.: R-ITUSP01V01

C E R T I F I C A T I O N

FCC 47 CFR PART 15 SUBPART B TEST REPORT KST DIGITAL TECHNOLOGY LIMITED. Brushless Servo

TABLE OF CONTENTS. 6. PHOTOGRAPH Photo of Conducted Emission Measurement Photo of Radiation Emission Measurement...

FCC 47 CFR PART 15 SUBPART C INDUSTRY CANADA RSS-210 ISSUE 8 CERTIFICATION TEST REPORT FOR. Dolphin CT50

Nemko-CCL, Inc West Alexander Street Salt Lake City, UT

APPLICATION FOR VERIFICATION On Behalf of Carewell Electric Technology (Zhongshan) Co., Ltd. REMOTE CONTROL Model No.: AC8 FCC ID: 2AAZPAC8

Version TEST REPORT NO. DATE DESCRIPTION

STC Test Report. The Hong Kong Standards and Testing Centre Ltd.

EMC TEST REPORT RADISYS CORPORATION. Tel: Fax:

FCC Test Report FCC ID: XN6-SB3651E6

Itron, Inc. TEST REPORT FOR. RF Telemetry Device Model: CCU100. Tested To The Following Standards:

FCC Part 15C Test Report

Report No.: DREFCC CONTENTS. 1. General Remarks Test Laboratory General Information of EUT... 4

FCC PART MEASUREMENT AND TEST REPORT FOR. Guangzhou Walkera Technology CO., LTD

FCC PART 15B TEST REPORT SZ DJI TECHNOLOGY CO., LTD

TEST REPORT. Reference No... : WTS16S E FCC ID... : SJ8-UDR777HD. Applicant... : RDI Technology Shenzhen Co., Ltd.

L.S. Compliance, Inc. W66 N220 Commerce Court Cedarburg, WI

TEST REPORT. Table of Contents

FCC Test Report. Report No.: AGC FE02 CLIENT : INNOVATIVE CONCEPTS AND DESIGN LLC. Attestation of Global Compliance (Shenzhen) Co., Ltd.

EMI T E S T R E P O R T

FCC REPORT. Dongguan Hele Electronics Co.,Ltd. * In the configuration tested, the EUT complied with the standards specified above.

TEST REPORT. : Masterbuilt Manufacturing Inc. 1 Masterbuilt Court Columbus, Georgia, 31907, USA

FCC DOC TEST REPORT. According to. 47 CFR, Part 2, Part 15, CISPR PUB. 22, ICES 003 Issue 6

EMC TEST REPORT. FCC 47 CFR Part 15B Industry Canada RSS-Gen Electromagnetic compatibility - Unintentional radiators Pleasanton USA

TEST SUMMARY Seite 2 von 19. Prüfbericht - Nr.: Test Report No.:

Revision history. Revision Date of issue Test report No. Description KES-RF-14T0042 Initial

Page 1 of 20 No.: HM TEST REPORT FCC PART 15 SUBPART C CERTIFICATION REPORT FOR LOW POWER TRANSMITTER. TEST REPORT No.

Declaration of Conformity (DoC)

Electromagnetic Compatibility Test Report

FCC Part 15B Measurement and Test Report. For. GlobTek, Inc. 186 Veterans Dr. Northvale, NJ USA. FCC Part 15 Subpart B.

No. 620 HuaYuan Commercial Center, No. 347 XiXiang Road,XiXiang Town, Bao An District, ShenZhen City Tel : Fax:

ORT. MobiWire. Brand. Product. Dakota. Model. Report No. April 22, Issue. TA Technology

FCC REPORT. 2AKQO-Q740 FCC CFR Title 47 Part 15 Subpart C. * In the configuration tested, the EUT complied with the standards specified above.

C E R T I F I C A T I O N

APPLICATION FOR VERIFICATION On behalf of MATRIX LIGHTING LTD. LED spot light. Model No.: 50-45GUS 50-45EUS Serial No.: E /02 E /02

FCC Test Report. Report No.: AGC FE03. : Shenzhen Liangzi Zhineng Technology Co., Ltd. Attestation of Global Compliance (Shenzhen) Co.

FCC 15B Test Report. : ac/a/b/g/n + Bluetooth 4.2 module (please refer to section for more details.)

FCC PART 15C TEST REPORT FOR CERTIFICATION On Behalf of. Trade Name : Activision. Model Number: / FCC ID: XLU

EMI Test Report. : BTv4.0 Dual Mode USB Dongle

DATES OF TESTS: From 03/10/2014 to 20/10/2014 and 25/02/2015. Open area test site in Aunainville (28) - FRANCE. Page 2 out of 54

Transcription:

TEST REPORT Title 47-Telecommunication Chapter I - Federal Communications Commission Subchapter A - General Part 5 - Radio Frequency Devices Subpart B - Unintentional Radiators Report Reference No.... : 293659TRFFCC Tested by (name, function and signature)... : Approved by (name, function and signature)... : Date of issue... : 205-09-8 Testing Laboratory... : Nemko Spa G. Bazzi (project handler)... G. Curioni (verifier) Address... : Via del Carroccio, 4 20853 Biassono (MB) Italy Testing location Nemko Spa Address... : Via del Carroccio, 4 20853 Biassono (MB) Italy Registration number: 48407 Applicant s name... : SECO S.r.l. Address... : Via Calamandrei, 9 Arezzo (AR) Italy Test specification: Standard... : FCC CFR 47 Part 5 Subpart B 5.07 Conducted limits 5.09 Radiated emission limits Test procedure... : Nemko WM L0077, WM L077 and WM L002 Test Report Form No.... : FCCTRF TRF Originator... : Nemko Spa Master TRF... : 204-03 Nemko Spa, 20853 Biassono (MB), Italy. All rights reserved. This publication may be reproduced in whole for non-commercial purposes as long as Nemko Spa is acknowledged as copyright owner and source of the material. Nemko Spa takes no responsibility for and will not assume liability for damages resulting from the reader's interpretation of the reproduced material due to its placement and context. Test item description... : Mini PC Trade Mark... : -- Manufacturer... : SECO S.r.l. Address of manufacturer... : Via Calamandrei, 9 Arezzo (AR) Italy Model... : UDOO Neo Full (Part N. SA69-0200-00-C0) Ratings... : Input: Output: 00-240V 50/60Hz 800mA 2Vdc 2000mA This test report may not be partially reproduced, except with the prior written permission of Nemko Spa The test report merely corresponds to the tested sample. The phase of sampling / collection of equipment under test is carried out by the customer. This Test Report, when bearing the Nemko name and logo is only valid when issued by a Nemko laboratory, or by a laboratory having special agreement with Nemko.

Page 2 of 22 Test Report No. : 293659TRFFCC 205-09-8 Date of issue The EuT is a mini PC Short description of the EuT Copy of marking plate Not labelled Number of tested samples: Serial number: Internal operating frequency: Class: Device type: Accessories and detachable parts included: Other options included: -- Testing / (assigned by Nemko Spa) 000 MHz Date of receipt of test sample: 205-09-8 Testing commenced on: 205-09-8 Testing concluded on: 205-09-8 Possible test case verdicts: test case does not apply to the test object: test object does meet the requirement: test object does not meet the requirement: Symbols used in this test report B Table Top/Rack Mounting The E.U.T. is composed by a single unit N (Not applicable) P (Pass) F (Fail) The crossed square indicates that the listed condition or equipment is applicable for this report. The empty square indicates that the listed condition or equipment is not applicable for this report. The results contained in this report reflect the results for this particular model and serial number. It is the responsibility of the manufacturer to ensure that all production models meet the intent of the requirements detailed within this report. Verdict according to the standards listed at page 5: Pass

Page 3 of 22 PROJECT HISTORY Report number Modification to the report / comments Date 293695TRFFCC First release 205-09-8 -- -- -- -- -- -- -- -- -- REMARKS PRODUCT VARIANTS Variant model Difference against the main model Additional test performed -- -- -- -- -- -- -- -- -- -- -- -- REMARKS

Page 4 of 22 Contents T E S T S T A N D A R D S 5 2 S U M M A R Y O F T E S T R E S U L T S 5 3 E Q U I P M E N T U N D E R T E S T 6 3. POWER SUPPLY SYSTEM UTILISED 6 3.2 EUT OPERATION MODES 6 3.3 EUT CONFIGURATION MODES 6 3.4 INPUT/OUTPUT PORTS 7 3.5 EQUIPMENT USED DURING TEST 8 4 T E S T E N V I R O N M E N T 9 4. ADDRESS OF THE TEST LABORATORY 9 4.2 ENVIRONMENTAL CONDITIONS 9 4.3 TEST EQUIPMENT USED FOR THE MONITORING OF THE ENVIRONMENTAL CONDITIONS 9 4.4 STATEMENT OF THE MEASUREMENT UNCERTAINTY 0 5 T E S T C O N D I T I O N S A N D R E S U L T S 5. CLAUSE 5.07 CONDUCTED LIMITS 5.2 CLAUSE 5.09 RADIATED EMISSIONS LIMIT 5 6 E U T P H O T O S 2 2

Page 5 of 22 T E S T S T A N D A R D S The tests were performed according to following standards and procedures. NEMKO WM L077: General routines for using instruments at Nemko NEMKO WM L002: Measurement Uncertainty - Policy and Statement NEMKO WM L0077: General routines to perform EMC tests FCC CFR 47 Part 5 Subpart B (0 3 Edition) Code of Federal Regulations Title 47 Part 5 Radio Frequency Devices Subpart B Unintentional radiation The main standard above contains references to other standards, which are listed below. ANSI C63.4 (2003) Methods of Measurement of Radio-Noise Emissions from Low-Voltage Electrical and Electronic Equipment in the Range of 9 khz to 40 GHz 2 S U M M A R Y O F T E S T R E S U L T S FCC Part 5 Subpart B requirements Part Test description Frequency range Verdict 5.07 Conducted emission 50 khz to 30 MHz P 5.09 Radiated emission 30 MHz to 8000 MHz P GENERAL REMARKS

Page 6 of 22 3 E Q U I P M E N T U N D E R T E S T 3. Power supply system utilised Power supply voltage: 230V/50 Hz / φ 5V/60Hz / φ 400V/50 Hz 3PE 400V/50 Hz 3NPE 2 VDC 24 VDC 3.2 EuT operation modes Mode Description EUT was tested connected to: power, HDMI cable loaded, keyboard, switch ethernet and MicroSD card 3.3 EuT configuration modes The EuT was configured to measure its highest possible radiation level. The test modes selected are according to EuT instruction manual. Mode The EuT was tested connected to the Mains. Description

Page 7 of 22 3.4 Input/Output Ports Cable Port Name Type* Max. >3m Cable Description Shielded 0 Enclosure N/E Mains AC/DC 2 Switch Ethernet I/O 3 Keyboard I/O 4 HDMI I/O Loaded *Note: AC = AC Power Port DC = DC Power Port N/E = Non-Electrical I/O = Signal/Control Input or Output Port TP = Telecommunication Ports

Page 8 of 22 3.5 Equipment Used During Test Use* Product Type Manufacturer Model Comments AE Keyboard Agilent Technologies AE Ethernet switch HP AE SD card Transcend 8 Gb Note: * Use EUT - Equipment Under Test AE - Auxiliary/Associated Equipment (Not Subjected to Test) SIM - Simulator (Not Subjected to Test)

Page 9 of 22 4 T E S T E N V I R O N M E N T 4. Address of the test laboratory Nemko Spa Via del Carroccio, 4 20853 Biassono (MB) - Italy Tests site/benches are in accordance with applicable standard/s, and have been utilized by Nemko Spa testing engineer(s). 4.2 Environmental conditions Unless different values are declared in the test case, following ambient conditions apply for the tests: Ambient temperature: 8 33 C Relative Humidity: 30 60 % Atmospheric pressure: 980 020 hpa 4.3 Test equipment used for the monitoring of the environmental conditions Equipment Manufacturer Model Serial N Thermohygrometer data loggers Testo 75-H2 2002380/305 Digital barometer Haenni ZED 50/.2 90030402/003

Page 0 of 22 4.4 Statement of the measurement uncertainty The data and results referenced in this document are true and accurate. The reader is cautioned that there may be errors within the calibration limits of the equipment and facilities. The measurement uncertainty was calculated for all measurements listed in this test report according to CISPR 6-4-2 Specification for radio disturbance and immunity measuring apparatus and methods Part 4-2: Uncertainties, statistics and limit modelling Uncertainty in EMC measurements and is documented in the Nemko Spa Technical Procedure WML002. Furthermore, component and process variability of devices similar to that tested may result in additional deviation. The manufacturer has the sole responsibility of continued compliance of the device. Hereafter the best measurement capability for Nemko Spa laboratory is reported: Test Radiated Disturbance 3m, 0m Chamber Range Antenna distance m, 3m, 0m (30 200) MHz Antenna distance m, 3m, 0m (0.2 6) GHz Antenna distance m, 3m (6 8) GHz Antenna distance m, 3m (8 40) GHz Measurement Uncertainty Notes 5.0 db () 5.2 db () 5.8 db () 7.2 db () 9 khz 50 khz with AMN 3.8 db () 50 khz 30 MHz with AMN 3.4 db () Conducted Disturbance 50 khz 30 MHz with AAN 4.6 db () 9 khz 30 MHz with voltage probe 2.9 db () 9 khz 30 MHz with current probe 2.9 db () NOTES: () The reported expanded uncertainty of measurement is stated as the standard uncertainty of measurement multiplied by the coverage factor k = 2 which has been derived from the assumed normal probability distribution with infinite degrees of freedom and for a coverage probability of 95 %;

Page of 22 5 T E S T C O N D I T I O N S A N D R E S U L T S 5. Clause 5.07 Conducted limits 5.. Photo documentation of the test set-up 5..2 Test method Measurements were made on a ground plane that extends -meter minimum beyond all sides of the system under test. All power was connected to the system through Line Impedance Stabilization Networks (LISN). Conducted voltage measurements on mains lines were made at the output of the LISN. 5..3 Limits for AC mains port Except for Class A digital devices, for equipment that is designed to be connected to the public utility (AC) power line, the radio frequency voltage that is conducted back onto the AC power line on any frequency or frequencies within the band 50 khz to 30 MHz shall not exceed the limits in the following table, as measured using a 50µH/50ohms line impedance stabilization network (LISN). Compliance with the provisions of this paragraph shall be based on the measurement of the radio frequency voltage between each power line and ground at the power terminal. The lower limit applies at the band edges. Frequency of emission (MHz) Quasi-Peak Conducted limit (dbµv) Average 0.5 to 0.50 66 to 56* 59 to 46* 0.50 to 5 56 46 5 to 30 60 50 *The limits decrease linearly with the logarithm of the frequency

Page 2 of 22 For a Class A digital device that is designed to be connected to the public utility (AC) power line, the radio frequency voltage that is conducted back onto the AC power line on any frequency or frequencies within the band 50 khz to 30 MHz shall not exceed the limits in the following table, as measured using a 50 µh/50 ohms LISN. Compliance with the provisions of this paragraph shall be based on the measurement of the radio frequency voltage between each power line and ground at the power terminal. The lower limit applies at the boundary between the frequency ranges. Frequency of emission (MHz) Quasi-Peak Conducted limit (dbµv) Average 0.5 to 0.50 79 66 0.50 to 30 73 60 5..4 Test result Verdict: P F N Frequency range: 0.5MHz - 30MHz Kind of test site: Shielded room Remarks: - 5..5 Test equipment used Equipment Manufacturer Model Serial N EMI receiver 9 khz 3 GHz R&S ESCI 00888 LISN 9 khz 30 MHz R&S ESH2-Z5 872 460/04 Shielded room Siemens Conducted emission test room 862

Page 3 of 22 5..6 Test protocol Test point: Operation mode: Configuration mode: Remarks: Phase line - Verdict: Pass Frequency (MHz) Level (dbµv) Limit (dbµv) Margin (db) Detector 9.2300 36. 50.0-3.9 AV 9.3820 4.6 60.0-8.4 QP 9.6820 34.8 50.0-5.2 AV

Page 4 of 22 Test point: Operation mode: Configuration mode: Remarks: Neutral line - Verdict: Pass Frequency (MHz) Level (dbµv) Limit (dbµv) Margin (db) Detector 9.3460 4.8 60.0-8.2 QP 9.5260 35.4 50.0-4.6 AV 9.6700 34.5 50.0-5.5 AV

Page 5 of 22 5.2 Clause 5.09 Radiated emissions limit 5.2. Photo documentation of the test set-up 5.2.2 Test method Measurements were made on a semi anechoic chamber. Preliminary (peak) measurements were performed at an antenna to EUT separation distance of 3 or 0 meters with the receive antenna located at a fixed height (from to 4 meter) in both horizontal and vertical polarities. Final measurements (quasi-peak) were then performed by rotating the EUT 360 and adjusting th e receive antenna height from to 4 meters. All frequencies were investigated in both horizontal and vertical antenna polarity, where applicable.

Page 6 of 22 5.2.3 Limits for enclosure Except for Class A digital devices, the field strength of radiated emissions from unintentional radiators at a distance of 3 meters shall not exceed the following values: Frequency of emission (MHz) Field strength (µv/m) Field strength (dbµv/m) 30 88 00 40.0 88 26 50 43.5 26 960 200 46.0 Above 960 500 54.0 The field strength of radiated emissions from a Class A digital device, as determined at a distance of 0 meters, shall not exceed the following: Frequency of emission (MHz) Field strength (µv/m) Field strength (dbµv/m) 30 88 90 39.0 88 26 50 43.5 26 960 20 46.4 Above 960 300 49.5 5.2.4 Test result Verdict: P F N Frequency range: Kind of test site: 30MHz - 8000MHz Semi anechoic chamber Measurement distance: 3 m Remarks: for an unintentional radiator, including a digital device, the spectrum shall be investigated from the lowest radio frequency signal generated or used in the device, without going below the lowest frequency for which a radiated emission limit is specified, up to the frequency shown as follow: If the intentional radiator operates at frequency upper than.705 MHz and lowers than 08 MHz the upper frequency of measurement range is 000 MHz. If the intentional radiator operates at frequency upper than 08 MHz and lowers than 500 MHz the upper frequency of measurement range is 2000 MHz. If the intentional radiator operates at frequency upper than 500 MHz and lowers than 000 MHz the upper frequency of measurement range is 5000 MHz. If the intentional radiator operates at frequency above 000 MHz the upper frequency of measurement range is 5th harmonic of the highest frequency or 40 GHz, whichever is lower. If the intentional radiator operates at or above 0 GHz and below 30 GHz to the fifth harmonic of the highest fundamental frequency or to 00 GHz, whichever is lower. If the intentional radiator operates at or above 30 GHz to the fifth harmonic of the highest fundamental frequency or to 200 GHz, whichever is lower, unless specified otherwise elsewhere in the rules.

Page 7 of 22 5.2.5 Test equipment used Equipment Manufacturer Model Serial N Trilog Broadband Antenna 25 8000 MHz Schwarzbeck VULB 962 962-025 Bilog antenna 8 GHz Schwarzbeck STLP 948-23 23 Broadband preamplifier Schwarzbeck BBV 978 978-37 Spectrum Analyzer 9kHz-40GHz R&S FSEK 848255/005 EMI receiver 20 Hz 8 GHz R&S ESU8 00202 Turn-table R&S HCT 835 803/03 Antenna mast R&S HCM 836 529/05 Controller R&S HCC 836 620/7 Semi-anechoic chamber Nemko 0m semi-anechoic chamber 530 Shielded room Siemens 0m control room 947

Page 8 of 22 5.2.6 Test protocol Antenna polarization: Operation mode: Configuration mode: Remarks: Horizontal Up to GHz Verdict: Pass Frequency (MHz) Level (dbµv/m) Limit (dbµv/m) Margin (db) Detector 95.4250 26.3 43.5-7.2 QP 05.5500 24.0 43.5-9.5 QP 77.9500 3.4 43.5-2. QP 86.6250 32.2 43.5 -.4 QP 95.3000 29.8 43.5-3.7 QP 240.3500 2.9 46.0-24. QP

Page 9 of 22 Antenna polarization: Operation mode: Configuration mode: Remarks: Horizontal GHz to 8 GHz Verdict: Pass Frequency (MHz) Level (dbµv/m) Limit (dbµv/m) Margin (db) Detector 32.5000 8.7 54.0-35.3 QP 38.7500 23. 54.0-30.9 QP 442.2500 24.5 54.0-29.5 QP 502.2500 30.8 54.0-23.2 QP 562.5000 25.5 54.0-28.5 QP 62.2500 9.9 54.0-34.0 QP

Page 20 of 22 Antenna polarization: Operation mode: Configuration mode: Remarks: Vertical Up to GHz Verdict: Pass Frequency (MHz) Level (dbµv/m) Limit (dbµv/m) Margin (db) Detector 36.5500 29.3 40.0-0.7 QP 74.2750 33.4 40.0-6.6 QP 80.250 28.2 40.0 -.8 QP 25.0250 28. 43.5-5.4 QP 43.750 22. 43.5-2.4 QP 240.3000 22.7 46.0-23.4 QP

Page 2 of 22 Antenna polarization: Operation mode: Configuration mode: Remarks: Vertical GHz to 8 GHz Verdict: Pass Frequency (MHz) Level (dbµv/m) Limit (dbµv/m) Margin (db) Detector 029.7500 0.4 54.0-43.6 QP 4.2500 4. 54.0-39.9 QP 250.0000 22.5 54.0-3.5 QP 502.7500 6.3 54.0-37.6 QP 2059.7500 5.7 54.0-38.2 QP 3000.5000 9.0 54.0-35.0 QP

Page 22 of 22 6 E U T P H O T O S End of report